Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Histogram”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Quantifying cell migration distance as a contributing factor to the development of rectal toxicity after prostate radiotherapy

Purpose: Spatial information is usually neglected in mathematical models of radiation-induced toxicity. In the presence of inhomogeneous dose distributions produced by intensity modulated radiation therapy (IMRT) and volumetric arc therapy, this may be a limitation. We present a model to quantify the spatial characteristics of the dose distribution on the rectum through the quantification of the distribution of distances between dose points on the surface of the rectum in three-dimensions. The method allows us to evaluate the hypothesis that distances between lower and higher dose regions on the rectum influence radiation damage repair due to the migration of normal cells into damaged areas, and consequently, the development of radiation-induced toxicity in patients treated with radiation for prostate cancer. Methods: We present a method to compute distances between dose points on the surface of the rectum in three dimensions (3D) and to generate distance maps representing the distances between specific dose regions on the rectum. We introduce the concept of the distance dose surface histogram (DDSH), which is computed from the distance maps. The DDSH is a 2D histogram of rectum area on a grid defined by pairwise combinations of dose and distance. Each bin in the DDSH quantifies the area of the rectum exposed to a given dose and at a given distance from other another dose region on the rectum. By summing across the columns and rows of the DDSH, we can generate the dose surface histogram (DSH) and distance surface histogram (DiSH) for a particular dose region. The DiSH is a marginal histogram showing the distribution of distances for the dose points in a specific dose region from another region. We computed the DDSH, DiSH, and DSH for 33 patients treated with IMRT for prostate cancer, nine of whom developed late Grade 2 or higher late rectal toxicity. Results: We show how even though the total area of the rectum exposed to a given dose may be the same for different patients, the distribution of distances for points receiving that dose can be different depending on the shape and contiguity of the region(s) containing those dose points. We also show that area of the rectum in the region receiving more than 75 Gy and at a distance of 16 to 22 mm from the 50 Gy isodose line was significantly correlated to the development of toxicity (p = 0.004, two sided t-test). This suggests that examining the distance distribution of points in specific dose regions could provide valuable additional information in predicting the risk of a patient developing radiation-induced rectal toxicity. Conclusions: We present a new method to quantify the spatial distribution of points in a given region relative to other regions on the rectum. The method provides a means to evaluate the hypothesis that distances between lower and higher dose regions on the rectum influence radiation damage repair due to the migration of normal cells into damaged areas, and may be a contributing factor to the development of radiation-induced toxicity in patients treated with radiation for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian Modeling Approach for Estimation of a Shape-Free Groundwater Age Distribution using Multiple Tracers

The mixing of groundwaters with different ages in aquifers, groundwater age is more appropriately represented by a distribution rather than a scalar number. To infer a groundwater age distribution from environmental tracers, a mathematical form is often assumed for the shape of the distribution and the parameters of the mathematical distribution are estimated using deterministic or stochastic inverse methods. We found that the prescription of the mathematical form limits the exploration of the age distribution to the shapes that can be described by the selected distribution. In this paper, the use of freeform histograms as groundwater age distributions is evaluated. A Bayesian Markov Chain Monte Carlo approach is used to estimate the fraction of groundwater in each histogram bin. This method was able to capture the shape of a hypothetical gamma distribution from the concentrations of four age tracers. The number of bins that can be considered in this approach is limited based on the number of tracers available. The histogram method was also tested on tracer data sets from Holten (The Netherlands; 3 H, 3 He, 85 Kr, 39 Ar) and the La Selva Biological Station (Costa-Rica; SF 6 , CFCs, 3 H, 4 He and 14 C), and compared to a number of mathematical forms. According to standard Bayesian measures of model goodness, the best mathematical distribution performs better than the histogram distributions in terms of the ability to capture the observed tracer data relative to their complexity. Among the histogram distributions, the four bin histogram performs better in most of the cases. The Monte Carlo simulations showed strong correlations in the posterior estimates of bin contributions, indicating that these bins cannot be well constrained using the available age tracers. The fact that mathematical forms overall perform better than the freeform histogram does not undermine the benefit of the freeform approach, especially for the cases where a larger amount of observed data is available and when the real groundwater distribution is more complex than can be represented by simple mathematical forms.

54 ENVIRONMENTAL SCIENCES↗

Boundary detection evaluation

Illustrative embodiments are directed to a method and apparatus for evaluating boundary detection in an image. A processed image is received, wherein a detected boundary of an image of an object is identified in the processed image. A Radon transform is applied to the processed image for a plurality of angles to form a processed image histogram corresponding to the detected boundary for each of the plurality of angles. The processed image histogram for each of the plurality of angles and a corresponding ground truth histogram for each of the plurality of angles is normalized to provide a normalized processed image histogram and a normalized ground truth histogram for each of the plurality of angles, wherein the ground truth histogram corresponds to a ground truth boundary of the object for a corresponding angle. An indication of the edges of the normalized processed image histogram for each of the plurality of angles is plotted to form a boundary detection evaluation visualization.

Wantuch, Andrew C.↗

Boundary detection evaluation

Illustrative embodiments are directed to a method and apparatus for evaluating boundary detection in an image. A processed image is received, wherein a detected boundary of an image of an object is identified in the processed image. A Radon transform is applied to the processed image for a plurality of angles to form a processed image histogram corresponding to the detected boundary for each of the plurality of angles. The processed image histogram for each of the plurality of angles and a corresponding ground truth histogram for each of the plurality of angles is normalized to provide a normalized processed image histogram and a normalized ground truth histogram for each of the plurality of angles, wherein the ground truth histogram corresponds to a ground truth boundary of the object for a corresponding angle. An indication of the edges of the normalized processed image histogram for each of the plurality of angles is plotted to form a boundary detection evaluation visualization.

Wantuch, Andrew C.↗

Efficient Levenberg-Marquardt minimization of the maximum likelihood estimator for Poisson deviates

Histograms of counted events are Poisson distributed, but are typically fitted without justification using nonlinear least squares fitting. The more appropriate maximum likelihood estimator (MLE) for Poisson distributed data is seldom used. We extend the use of the Levenberg-Marquardt algorithm commonly used for nonlinear least squares minimization for use with the MLE for Poisson distributed data. In so doing, we remove any excuse for not using this more appropriate MLE. We demonstrate the use of the algorithm and the superior performance of the MLE using simulations and experiments in the context of fluorescence lifetime imaging. Scientists commonly form histograms of counted events from their data, and extract parameters by fitting to a specified model. Assuming that the probability of occurrence for each bin is small, event counts in the histogram bins will be distributed according to the Poisson distribution. We develop here an efficient algorithm for fitting event counting histograms using the maximum likelihood estimator (MLE) for Poisson distributed data, rather than the non-linear least squares measure. This algorithm is a simple extension of the common Levenberg-Marquardt (L-M) algorithm, is simple to implement, quick and robust. Fitting using a least squares measure is most common, but it is the maximum likelihood estimator only for Gaussian-distributed data. Non-linear least squares methods may be applied to event counting histograms in cases where the number of events is very large, so that the Poisson distribution is well approximated by a Gaussian. However, it is not easy to satisfy this criterion in practice - which requires a large number of events. It has been well-known for years that least squares procedures lead to biased results when applied to Poisson-distributed data; a recent paper providing extensive characterization of these biases in exponential fitting is given. The more appropriate measure based on the maximum likelihood estimator (MLE) for the Poisson distribution is also well known, but has not become generally used. This is primarily because, in contrast to non-linear least squares fitting, there has been no quick, robust, and general fitting method. In the field of fluorescence lifetime spectroscopy and imaging, there have been some efforts to use this estimator through minimization routines such as Nelder-Mead optimization, exhaustive line searches, and Gauss-Newton minimization. Minimization based on specific one- or multi-exponential models has been used to obtain quick results, but this procedure does not allow the incorporation of the instrument response, and is not generally applicable to models found in other fields. Methods for using the MLE for Poisson-distributed data have been published by the wider spectroscopic community, including iterative minimization schemes based on Gauss-Newton minimization. The slow acceptance of these procedures for fitting event counting histograms may also be explained by the use of the ubiquitous, fast Levenberg-Marquardt (L-M) fitting procedure for fitting non-linear models using least squares fitting (simple searches obtain {approx}10000 references - this doesn't include those who use it, but don't know they are using it). The benefits of L-M include a seamless transition between Gauss-Newton minimization and downward gradient minimization through the use of a regularization parameter. This transition is desirable because Gauss-Newton methods converge quickly, but only within a limited domain of convergence; on the other hand the downward gradient methods have a much wider domain of convergence, but converge extremely slowly nearer the minimum. L-M has the advantages of both procedures: relative insensitivity to initial parameters and rapid convergence. Scientists, when wanting an answer quickly, will fit data using L-M, get an answer, and move on. Only those that are aware of the bias issues will bother to fit using the more appropriate MLE for Poisson deviates. However, since there is a simple, analytical formula for the appropriate MLE measure for Poisson deviates, it is inexcusable that least squares estimators are used almost exclusively when fitting event counting histograms. There have been ways found to use successive non-linear least squares fitting to obtain similarly unbiased results, but this procedure is justified by simulation, must be re-tested when conditions change significantly, and requires two successive fits. There is a great need for a fitting routine for the MLE estimator for Poisson deviates that has convergence domains and rates comparable to the non-linear least squares L-M fitting. We show in this report that a simple way to achieve that goal is to use the L-M fitting procedure not to minimize the least squares measure, but the MLE for Poisson deviates.

59 BASIC BIOLOGICAL SCIENCES↗

GPU Acceleration of Kernel Density Estimators in Monte Carlo Neutron Transport Simulations

Kernel Density Estimators (KDEs) have recently been explored for use in Monte Carlo radiation transport simulations as an alternative to histogram tallies for capturing spatially-resolved quantities such as neutron flux and reaction rates. Histogram tallies suffer from large uncertainties when detailed spatial resolution of the quantity of interest is required; increasing the resolution of the underlying mesh increases the uncertainty in each histogram bin. KDEs obtain estimates of underlying densities on user-defined points, with the uncertainty at those points being independent of the spatial resolution desired since collisions and particle-track segments are allowed to contribute to the score at multiple tally points. Thus, KDEs show potential for obtaining estimates of a smoother spatially-resolved with reduced variance when compared to a histogram. However, this ability that enables KDEs to obtain lower uncertainties per particle history is more computationally expensive than using a traditional histogram bins on a structured mesh. While KDEs are capable of producing lower tally uncertainties compared to histogram binning for a given number of histories, their increased computational cost may make them less efficient. Even so, it is possible to reduce this additional cost by exporting the KDE tally routines onto Graphics Processing Units (GPUs). GPUs are commonly found on high-performance computing machines as a means of increasing performance without adding additional compute nodes. While it is difficult for existing Monte Carlo radiation transport codes to take advantage of GPUs without rewriting large portions of the code, it is possible to leverage GPUs through heterogeneous computing. This work uses a modified version of OpenMC and exports the KDE tally routines onto a GPU to obtain problem-dependent speedups ranging between 1.6 and 5.0 for the problem studied in this paper. While this methodology is applied to KDEs, the same ideas can be applied to other computationally expensive vectorizable portions of Monte Carlo algorithms. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Texture analysis of small renal cell carcinomas at MDCT for predicting relevant histologic and protein biomarkers

Purpose: To assess CT texture features of small renal cell carcinomas (≤ 4cm) for association with key pathologic features including protein biomarkers. Methods: Quantitative CT texture analysis (CTTA) of small renal cancers (≤ 4cm) was performed on non-contrast and portal venous phase abdominal MDCT scans with an ROI drawn at the largest cross-sectional diameter of the tumor using commercially available software. Texture parameters including mean pixel attenuation, the standard deviation (SD) of the pixel distribution histogram, entropy, the mean of positive pixels, the skewness (i.e., asymmetry) of the pixel histogram, kurtosis (i.e., peakness) of the pixel histogram, and the percentage of positive pixels were correlated with pathologic data from surgical resection, including histology and nuclear grade, as well as microarray analysis in a subset (n = 40) including Ki67 index, CRP, and neovascularization (CD105/CD31). Results: Portal venous phase images were available in 249 patients (105 women, 144 men; mean age, 56.7 years) with tumors ≤ 4cm (mean, median, range, ± SD; 2.66, 2.60, 0.3–4.0 ± 0.85 cm). CT texture features of standard deviation, mean of the positive pixels, and entropy of the pixel histogram were significantly associated with histologic cell type (clear vs. non-clear; p < 0.001). Entropy and mean of the positive pixels also showed an association with nuclear grade, although not statistically significant. In the microarray analysis subset, kurtosis of the pixel histogram was associated with CD105/CD31 (p = 0.05). SD also showed some association with CD 105 positivity (p = 0.02) and CAIX expression (p = 0.01). Non-contrast CT images were available in 174 patients (72 women, 102 men; mean age, 57.5 years). Although the association with histology was not as strong as on the portal venous phase, in the subset of patients with microarray data, SD was found to correlate with CRP (p = 0.08), kurtosis with CRP (p = 0.004), CD105/CD31 (p = 0.002), and with Ki 67 index (p < 0.001). Conclusion: CT texture features were significantly associated with important histopathologic features in small renal cancers. These non-invasive measures can be performed retrospectively and may provide useful information when determining follow-up and treatment of small renal cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Prospective Clinical Trial of Bladder Filling and Three-Dimensional Dosimetry in High-Dose-Rate Vaginal Cuff Brachytherapy

Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladder were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Rectal Toxicity on RTOG 94-06: Analysis Using a Mixture Lyman Model

Purpose: To estimate the parameters of the Lyman normal-tissue complication probability model using censored time-to-event data for Grade {>=}2 late rectal toxicity among patients treated on Radiation Therapy Oncology Group 94-06, a dose-escalation trial designed to determine the maximum tolerated dose for three-dimensional conformal radiotherapy of prostate cancer. Methods and Materials: The Lyman normal-tissue complication probability model was fitted to data from 1,010 of the 1,084 patients accrued on Radiation Therapy Oncology Group 94-06 using an approach that accounts for censored observations. Separate fits were obtained using dose-volume histograms for whole rectum and dose-wall histograms for rectal wall. Results: With a median follow-up of 7.2 years, the crude incidence of Grade {>=}2 late rectal toxicity was 15% (n = 148). The parameters of the Lyman model fitted to dose-volume histograms data, with 95% profile-likelihood confidence intervals, were TD{sub 50} = 79.1 Gy (75.3 Gy, 84.3 Gy), m = 0.146 (0.107, 0.225), and n = 0.077 (0.041, 0.156). The fit based on dose-wall histogram data was not significantly different. Patients with cardiovascular disease had a significantly higher incidence of late rectal toxicity (p = 0.015), corresponding to a dose-modifying factor of 5.3%. No significant association with late rectal toxicity was found for diabetes, hypertension, rectal volume, rectal length, neoadjuvant hormone therapy, or prescribed dose per fraction (1.8 Gy vs. 2 Gy). Conclusions: These results, based on a large cohort of patients from a multi-institutional trial, are expected to be widely representative of the ability of the Lyman model to describe the long-term risk of Grade {>=}2 late rectal toxicity after three-dimensional conformal radiotherapy of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the dosimetry of organ-at-risk in head and neck IMRT planning: An intertechnique and interinstitutional study

Purpose: To build a statistical model to quantitatively correlate the anatomic features of structures and the corresponding dose-volume histogram (DVH) of head and neck (HN) Tomotherapy (Tomo) plans. To study if the model built upon one intensity modulated radiation therapy (IMRT) technique (such as conventional Linac) can be used to predict anticipated organs-at-risk (OAR) DVH of patients treated with a different IMRT technique (such as Tomo). To study if the model built upon the clinical experience of one institution can be used to aid IMRT planning for another institution. Methods: Forty-four Tomotherapy intensity modulate radiotherapy plans of HN cases (Tomo-IMRT) from Institution A were included in the study. A different patient group of 53 HN fixed gantry IMRT (FG-IMRT) plans was selected from Institution B. The analyzed OARs included the parotid, larynx, spinal cord, brainstem, and submandibular gland. Two major groups of anatomical features were considered: the volumetric information and the spatial information. The volume information includes the volume of target, OAR, and overlapped volume between target and OAR. The spatial information of OARs relative to PTVs was represented by the distance-to-target histogram (DTH). Important anatomical and dosimetric features were extracted from DTH and DVH by principal component analysis. Two regression models, one for Tomotherapy plan and one for IMRT plan, were built independently. The accuracy of intratreatment-modality model prediction was validated by a leave one out cross-validation method. The intertechnique and interinstitution validations were performed by using the FG-IMRT model to predict the OAR dosimetry of Tomo-IMRT plans. The dosimetry of OARs, under the same and different institutional preferences, was analyzed to examine the correlation between the model prediction and planning protocol. Results: Significant patient anatomical factors contributing to OAR dose sparing in HN Tomotherapy plans have been analyzed and identified. For all the OARs, the discrepancies of dose indices between the model predicted values and the actual plan values were within 2.1%. Similar results were obtained from the modeling of FG-IMRT plans. The parotid gland was spared in a comparable fashion during the treatment planning of two institutions. The model based on FG-IMRT plans was found to predict the median dose of the parotid of Tomotherapy plans quite well, with a mean error of 2.6%. Predictions from the FG-IMRT model suggested the median dose of the larynx, median dose of the brainstem and D2 of the brainstem could be reduced by 10.5%, 12.8%, and 20.4%, respectively, in the Tomo-IMRT plans. This was found to be correlated to the institutional differences in OAR constraint settings. Re-planning of six Tomotherapy patients confirmed the potential of optimization improvement predicted by the FG-IMRT model was correct. Conclusions: The authors established a mathematical model to correlate the anatomical features and dosimetric indexes of OARs of HN patients in Tomotherapy plans. The model can be used for the setup of patient-specific OAR dose sparing goals and quality control of planning results. The institutional clinical experience was incorporated into the model which allows the model from one institution to generate a reference plan for another institution, or another IMRT technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-BRF-09: Gaussian Mixture Model Analysis of Radiation-Induced Parotid-Gland Injury: An Ultrasound Study of Acute and Late Xerostomia in Head-And-Neck Radiotherapy

Purpose: Xerostomia (dry mouth), secondary to parotid-gland injury, is a distressing side-effect in head-and-neck radiotherapy (RT). This study's purpose is to develop a novel ultrasound technique to quantitatively evaluate post-RT parotid-gland injury. Methods: Recent ultrasound studies have shown that healthy parotid glands exhibit homogeneous echotexture, whereas post-RT parotid glands are often heterogeneous, with multiple hypoechoic (inflammation) or hyperechoic (fibrosis) regions. We propose to use a Gaussian mixture model to analyze the ultrasonic echo-histogram of the parotid glands. An IRB-approved clinical study was conducted: (1) control-group: 13 healthy-volunteers, served as the control; (2) acutetoxicity group − 20 patients (mean age: 62.5 ± 8.9 years, follow-up: 2.0±0.8 months); and (3) late-toxicity group − 18 patients (mean age: 60.7 ± 7.3 years, follow-up: 20.1±10.4 months). All patients experienced RTOG grade 1 or 2 salivary-gland toxicity. Each participant underwent an ultrasound scan (10 MHz) of the bilateral parotid glands. An echo-intensity histogram was derived for each parotid and a Gaussian mixture model was used to fit the histogram using expectation maximization (EM) algorithm. The quality of the fitting was evaluated with the R-squared value. Results: (1) Controlgroup: all parotid glands fitted well with one Gaussian component, with a mean intensity of 79.8±4.9 (R-squared>0.96). (2) Acute-toxicity group: 37 of the 40 post-RT parotid glands fitted well with two Gaussian components, with a mean intensity of 42.9±7.4, 73.3±12.2 (R-squared>0.95). (3) Latetoxicity group: 32 of the 36 post-RT parotid fitted well with 3 Gaussian components, with mean intensities of 49.7±7.6, 77.2±8.7, and 118.6±11.8 (R-squared>0.98). Conclusion: RT-associated parotid-gland injury is common in head-and-neck RT, but challenging to assess. This work has demonstrated that the Gaussian mixture model of the echo-histogram could quantify acute and late toxicity of the parotid glands. This study provides meaningful preliminary data from future observational and interventional clinical research.

60 APPLIED LIFE SCIENCES↗

Postmortem validation of breast density using dual-energy mammography

Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.

60 APPLIED LIFE SCIENCES↗

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-45: An Automated Technique to Measure Image Contrast in Clinical CT Images

Purpose: To develop and validate an automated technique for measuring image contrast in chest computed tomography (CT) exams. Methods: An automated computer algorithm was developed to measure the distribution of Hounsfield units (HUs) inside four major organs: the lungs, liver, aorta, and bones. These organs were first segmented or identified using computer vision and image processing techniques. Regions of interest (ROIs) were automatically placed inside the lungs, liver, and aorta and histograms of the HUs inside the ROIs were constructed. The mean and standard deviation of each histogram were computed for each CT dataset. Comparison of the mean and standard deviation of the HUs in the different organs provides different contrast values. The ROI for the bones is simply the segmentation mask of the bones. Since the histogram for bones does not follow a Gaussian distribution, the 25th and 75th percentile were computed instead of the mean. The sensitivity and accuracy of the algorithm was investigated by comparing the automated measurements with manual measurements. Fifteen contrast enhanced and fifteen non-contrast enhanced chest CT clinical datasets were examined in the validation procedure. Results: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast enhanced chest CT exams. The automated measurements were in agreement with manual measurements. The algorithm has sufficient sensitivity as indicated by the near unity slope of the automated versus manual measurement plots. Furthermore, the algorithm has sufficient accuracy as indicated by the high coefficient of determination, R2, values ranging from 0.879 to 0.998. Conclusion: Patient-specific image contrast can be measured from clinical datasets. The algorithm can be run on both contrast enhanced and non-enhanced clinical datasets. The method can be applied to automatically assess the contrast characteristics of clinical chest CT images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

The Poisson tensor completion non-parametric differential entropy estimator

We introduce the Poisson tensor completion (PTC) estimator, a non-parametric differential entropy estimator. The PTC estimator leverages inter-sample relationships to compute a low-rank Poisson tensor decomposition of the frequency histogram. Our crucial observation is that the histogram bins are an instance of a space partitioning of counts and thus can be identified with a spatial Poisson process. The Poisson tensor decomposition leads to a completion of the intensity measure over all bins—including those containing few to no samples—and leads to our proposed PTC differential entropy estimator. A Poisson tensor decomposition models the underlying distribution of the count data and guarantees non-negative estimated values and so can be safely used directly in entropy estimation. Our estimator is the first tensor-based estimator that exploits the underlying spatial Poisson process related to the histogram explicitly when estimating the probability density with low-rank tensor decompositions for the purpose of tensor completion. Furthermore, we demonstrate that our PTC estimator is a substantial improvement over standard histogram-based estimators for sub-Gaussian probability distributions because of the concentration of norm phenomenon.

42 ENGINEERING↗

Apple Strength Issues

Strength of the apple parts has been noticed to decrease, especially those installed by the new induction heating system since the LEP campaign started. Fig. 1 shows the ultimate tensile strength (UTS), yield strength (YS), and elongation of the installed or installation-simulated apples on various systems. One can clearly see the mean values of UTS and YS of the post-LEP parts decreased by about 8 ksi and 6 ksi respectively from those of the pre-LEP parts. The slight increase in elongation seen in Fig.1 can be understood from the weak inverse relationship between the strength and elongation in metals. Fig.2 shows the weak correlation between the YS and elongation of the parts listed in Fig. 1. Strength data listed in Figure 1 were re-plotted as histograms in Figs. 3 and 4. Figs. 3a and 4a show histograms of all UTS and YS data. Figs. 3b and 4b shows histograms of pre-LEP data and Figs. 3c and 4c of post-LEP data. Data on statistical scatter of tensile strengths have been rarely published by material suppliers. Instead, only the minimum 'guaranteed' strength data are typically presented. An example of strength distribution of aluminum 7075-T6 sheet material, listed in Fig. 5, show that its scatter width of both UTS and YS for a single sheet can be about 6 ksi and for multi-lot scatter can be as large as 11 ksi even though the sheets have been produced through well-controlled manufacturing process. By approximating the histograms shown in Figs. 3 and 4 by a Gaussian or similar type of distribution curves, one can plausibly see the strength reductions in the later or more recent apples. The pre-LEP data in Figs. 3b and 4b show wider scatter than the post-LEP data in Figs. 3c and 4c and seem to follow the binomial distribution of strength indicating that the apples might have been made from two different lots of material, either from two different vendors or from two different melts of perhaps slightly different chemical composition by a single vendor. The post-LEP apples seem to have been from a single batch of material. The pre-LEP apples of the weak strength and the post-LEP apples with even weaker strength could have been made of the same batch of material, and the small strength differential might be due to the difference in the induction heating system. If the pre-LEP apples with the lower strength and the post LEP apples are made from the same batch of material, their combined scatter of strength data would be wider and can be understood as a result of the additional processing steps of stress relief and induction heating as discussed.

36 MATERIALS SCIENCE↗