Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High pressure instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Controlled experiments from the Space Shuttle

A study has been carried out to identify the controlled space physics and plasma physics experiments that can be performed from the Space Shuttle on sortie missions of 7 to 30-day duration. An experiment facility of this type appears to be well-matched to the sortie missions capability, and a technically feasible laboratory can provide a base for an extensive and significant research program to be carried out during the 1980-1990 time period. The laboratory, known as PPEPL, consists of a 33-ft pallet of instruments connected to a 25-ft pressurized control module. Two deployable 50-m booms, two subsatellites, a high power transmitter, a multipurpose high-power accelerator array, a set of deployable canisters for releases, and a gimbaled platform for pointing instruments are the primary systems mounted on the pallet.

Scarf, F. L.↗

High-temperature, high-pressure optical port for rocket engine applications

This paper discusses the design, fabrication, and test of a window assembly for instrumentation of liquid-fueled rocket engine hot gas systems. The window was designed to allow optical measurements of hot gas in the SSME fuel preburner and appears to be the first window designed for application in a rocket engine hot gas system. Such a window could allow the use of a number of remote optical measurement technologies including: Raman temperature and species concentration measurement, Raleigh temperature measurements, flame emission monitoring, flow mapping, laser-induced florescence, and hardware imaging during engine operation. The window assembly has been successfully tested to 8,000 psi at 1000 F and over 11,000 psi at room temperature. A computer stress analysis shows the window will withstand high temperature and cryogenic thermal shock.

Delcher, Ray↗

High temperature UF6 RF plasma experiments applicable to uranium plasma core reactors

An investigation was conducted using a 1.2 MW RF induction heater facility to aid in developing the technology necessary for designing a self critical fissioning uranium plasma core reactor. Pure, high temperature uranium hexafluoride (UF6) was injected into an argon fluid mechanically confined, steady state, RF heated plasma while employing different exhaust systems and diagnostic techniques to simulate and investigate some potential characteristics of uranium plasma core nuclear reactors. The development of techniques and equipment for fluid mechanical confinement of RF heated uranium plasmas with a high density of uranium vapor within the plasma, while simultaneously minimizing deposition of uranium and uranium compounds on the test chamber peripheral wall, endwall surfaces, and primary exhaust ducts, is discussed. The material tests and handling techniques suitable for use with high temperature, high pressure, gaseous UF6 are described and the development of complementary diagnostic instrumentation and measurement techniques to characterize the uranium plasma, effluent exhaust gases, and residue deposited on the test chamber and exhaust system components is reported.

Roman, W. C.↗

The structural dynamics analysis of the main injector LOX inlet tee and its redesign

A ground test of a specially instrumented Space Shuttle Main Engine (SSME) revealed excessively high strains in the high pressure Liquid Oxygen (LOX) inlet line which carries LOX to the Main Injector. The inlet tee acts as a manifold which utilizes two splitter vanes to direct the flow of LOX into the main injector. When the high strains were discovered, it was thought that these splitter vanes, coupled with high energy flow was the source. This resulted not only in high strains in the LOX inlet tee, but excessive vibration at a frequency of 4000 Hz located at the gimbal bearing, and at the main injector. This was later to be known as The 4kHz Phenomenon. The dynamic analysis which was used to predict the response due to the 4kHz phenomenon and the analysis used to aid in the design modification required to the hardware to reduce or eliminate the phenomenon is examined.

Romano, E.↗

Development of Particulates and Aerosols Research

During the past year several accomplishments were made for both the Particulate Matter Characterization and Measurement System, (PMCMS) and PAGEMS projects. The PAGEMS focus is to measure particulate emissions as a function of combustor parameters such as inlet temperature, inlet pressure and fuel air ratio. These measurements are used to evaluate combustor performance in hopes of correlating particulate emissions with engine conditions. These measurements have taken place at in-house NASA combustor facilities and off-site facilities. Ths work is unique because particulate measurements at high- pressure conditions are not commonly made. Some calibration of the PAGEMS instrumentation was done as well as minor modifications to the PAGEMS plumbing setup. These led to measurement improvements. The instrumentation and measurement process for PAGEMS was assessed and new instruments such as a thermodenuder, thermal mass flow meters and a cyclone separator were purchased to improve the PAGEMS instrumentation and measurement process. A worksheet was created to simulate varying inlet conditions to the DMA. This worksheet allows the user to assess the error in the measurements when certain conditions exist. Two technical papers were written with the PAGEMS team for the EXCAVATE field project. A paper was also reviewed for an in house publication. Also data was processed and analyzed for another field project (PAX) and will be part of a third PAGEMS paper. Accomplishments were also made with the PMCMS project. The calibration of the radial differential mobility analyzer, (RDMA) in the particle sizing system in the PMCMS was completed and provided satisfactory results. The voltages used for the RDMA depending on the particle of interest were corrected. The measurement capability of the PMCMS was increased by replacing the MetOne CPC with a TSI CPC. Lastly, assistance was provided to three college summer students with calibration of their particulate equipment and Monica Rivera shared her understanding of the aerosol technology with them. She also provided input for their end of the summer presentations. And attended the Aviation and Particle Emissions workshop. This workshop brought together experts in the aircraft particulate emissions field. As a result Ms. Rivera made two significant contacts with academia (UMR) and government (WPAFB) which could lead to future collaboration. She also attended the Aerosol and Particle Measurement Class held at the University of Minnesota. This class refreshed her particulate knowledge and introduced her to new aerosol applications and technology. Furthermore at the class contacts were made with private industry (TSI) and government (WPAFB). Ms. Rivera also enhanced her education by taking an in-house class on aircraft design and operation.

DeWitt, Kenneth↗

Automated Blood Pressure Measurement

The Vital-2 unit pictured is a semi-automatic device that permits highly accurate blood pressure measurement, even by untrained personnel. Developed by Meditron Instrument Corporation, Milford, New Hampshire, it is based in part on NASA technology found in a similar system designed for automatic monitoring of astronauts' blood pressure. Vital-2 is an advancement over the familiar arm cuff, dial and bulb apparatus customarily used for blood pressure checks. In that method, the physician squeezes the bulb to inflate the arm cuff, which restricts the flow of blood through the arteries. As he eases the pressure on the arm, he listens, through a stethoscope, to the sounds of resumed blood flow as the arteries expand and contract. Taking dial readings related to sound changes, he gets the systolic (contracting) and diastolic (expanding) blood pressure measurements. The accuracy of the method depends on the physician's skill in interpreting the sounds. Hospitals sometimes employ a more accurate procedure, but it is "invasive," involving insertion of a catheter in the artery.

Source record↗

Plume diagnostics of SRM static firings for pressure perturbation studies

During the shuttle launches, the solid rocket motors (SRM) occasionally experience pressure perturbations (8-13 psi) between 65 and 75 seconds into the motor burn time. The magnitudes of these perturbations are very small in comparison with the operating motor chamber pressure, which is over 600 psi during this time frame. These SRM pressure perturbations are believed to be caused primarily by the expulsion of slag (aluminum oxide). Two SRM static tests, TEM-11 and FSM-4, were instrumented extensive]y for the study of the phenomenon associated with pressure perturbations. The test instrumentation used included nonintrusive optical and infrared diagnostics of the plume, such as high-speed photography, radiometers, and thermal image cameras. Results from all these nonintrusive observations strongly support the scenario that the pressure perturbation event in the shuttle SRM is caused primarily by the expulsion of molten slag. The slag was also expelled preferentially near the bottom of the nozzle due to slag accumulation at the bottom of the aft end of the horizontally oriented motor.

Sambamurthi, J. K.↗

The relationship between the magnetic field in the Martian magnetotail and upstream solar wind parameters

Magnetic field data measured by the MAGMA instrument in the Martian magnetotail lobes are compared with the ram pressure of the upstream solar wind observed by the TAUS instrument in the circular orbits of the Phobos 2 spacecraft. High correlation was found between the magnetic field intensity in the Martian magnetotail lobes and the solar wind ram pressure. From this relationship the average flaring angle of the Martian magnetotail was determined as approximately 13 deg, and the average magnetosonic Mach number was estimated as approximately 5. The observed relationship between the Martian magnetotail magnetic field intensity and the solar wind magnetic field reflects the correlation of the solar wind magnetic field to the ram pressure providing a value of approximately 7 for the average Alfvenic Mach number. The flaring angle obtained for the Martian magnetotail was found to be an intermediate value between the flaring angle of the magnetotail of the Earth and that of Venus at comparable distances.

Rosenbauer, H.↗

A Unique, Optically Accessible Flame Tube Facility for Lean Combustor Studies

A facility that allows interrogation of combusting flows by advanced diagnostic methods and instrumentation has been developed at the NASA Lewis Research Center. An optically accessible flame tube combustor is described which has high temperature, pressure, and air flow capabilities. The windows in the combustor measure 3.8 cm axially by 5.1 cm radially, providing 67% optical access to the 7.6 cm x 7.6 cm cross section flow chamber. Advanced gas analysis instrumentation is available through a gas chromatography/mass spectrometer system (GC/MS), which has on-line capability for heavy hydrocarbon measurement with resolution to the parts per billion level. The instrumentation allows one to study combusting flows and combustor subcomponents, such as fuel injectors and air swirlers. Planar Laser Induced Fluorescence (PLIF) can measure unstable combustion species, which cannot be obtained with traditional gas sampling. This type of data is especially useful to combustion modellers. The optical access allows measurements to have high spatial and temporal resolution. GC/MS data and PLIF images of OH- are presented from experiments using a lean direct injection (LDI) combustor burning Jet-A fuel at inlet temperatures ranging from 810 K to 866 K, combustor pressures up to 1380 kPa, and equivalence ratios from 0.41 to 0.59.

Hicks, Yolanda R.↗

Subsonic and transonic pressure measurements on a high-aspect-ratio supercritical-wing model with oscillating control surfaces

A high aspect ratio supercritical wing with oscillating control surfaces is described. The semispan wing model was instrumented with 252 static orifices and 164 in situ dynamic pressure gases for studying the effects of control surface position and sinusoidal motion on steady and unsteady pressures. Data from the present test (this is the second in a series of tests on this model) were obtained in the Langley Transonic Dynamics Tunnel at Mach numbers of 0.60 and 0.78 and are presented in tabular form.

Sandford, M. C.↗

Phase A conceptual design study of the Atmospheric, Magnetospheric and Plasmas in Space (AMPS) payload

The 12 month Phase A Conceptual Design Study of the Atmospheric, Magnetospheric and Plasmas in Space (AMPS) payload performed within the Program Development Directorate of the Marshall Space Flight Center is presented. The AMPS payload makes use of the Spacelab pressurized module and pallet, is launched by the space shuttle, and will have initial flight durations of 7 days. Scientific instruments including particle accelerators, high power transmitters, optical instruments, and chemical release devices are mounted externally on the Spacelab pallet and are controlled by the experimenters from within the pressurized module. The capability of real-time scientist interaction on-orbit with the experiment is a major characteristic of AMPS.

Source record↗

Correlation of Slag Expulsion with Ballistic Anomalies in Shuttle Solid Rocket Motors

During the Shuttle launches, the solid rocket motors (SRM) occasionally experience pressure perturbations (8-13 psi) between 65-75 s into the motor burn time. The magnitudes of these perturbations are very small in comparison with the operating motor chamber pressure, which is over 600 psi during this time frame. These SRM pressure perturbations are believed to he caused primarily by the expulsion of slag (aluminum oxide). Two SRM static tests, TEM-11 and FSM-4, were instrumented extensively for the study of the phenomena associated with pressure perturbations. The test instrumentation used included nonintrusive optical and infrared diagnostics of the plume, such as high-speed photography, radiometers, and thermal image cameras. Results from all of these nonintrusive observations provide substantial circumstantial evidence to support the scenario that the pressure perturbation event in the Shuttle SRM is caused primarily by the expulsion of molten slag. In the static motor tests, the slag was also expelled preferentially near the bottom of the nozzle because of slag accumulation at the bottom of the aft end of the horizontally oriented motor.

Sambamurthi, Jay K.↗

White Papers for the Next Decadal Survey: Thermal Protection Systems and Instrumentation

NASA is anticipated to commission the next Planetary Science Decadal Survey (PSDS) with preparation expected in early calendar year 2020. The new PSDS will outline the priorities of science missions for the decade spanning 2023-2032. For the previous PSDS, the science and technology communities have been invited to submit white papers to the PSDS sub-panels as background information to guide the PSDS recommendations. The National Research Council has previously stated that white papers that represent the opinion of many authors from different institutions carried more significant and weight, and the recommendations from the previous PSDS attempted to reflect more of a consensus opinion.In 2009, a total of 4 white papers were submitted to the PSDS panels regarding thermal protection system (TPS) readiness for missions, as well as one on TPS instrumentation. The TPS readiness papers were co-authored by 90 individuals from many institutions. These white papers surveyed the TPS materials for both forebody and afterbody of a probe and analyzed the suitability of materials for missions to each destination. In addition, each paper outlined the ground testing required and ongoing technology development. Recommendations were provided for further technology development and ground test capability in order to fulfill future missions. Planning for the next PSDS: Many improvements and changes have occurred in the past 10 years with regard to TPS materials and instrumentation. New materials have been developed and tested, such as the high density material Heatshield for Extreme Entry Environment Technology (HEEET), and new capabilities for ground testing for high heating and high pressures have been added such as the 3” nozzle at the Ames arc jet. NASA has also flown several TPS instrumentation suites, such as MEDLI and EFT-1.In order to provide the PSDS sub-panels with the most current information about the state-of-the-art suit-ability for TPS materials for entry missions, we are be-ginning to update and draft new white papers. We will present the outline for material to be covered in the white papers, and we invite all IPPW attendees to parti-ciate in co-authoring these papers.

Hwang, H. H.↗

Study and evaluation of impulse mass spectrometers for ion analysis in the D and E regions of the ionosphere

Theoretical and numerical analyses were made of planar, cylindrical and spherical electrode time-of-flight mass spectrometers in order to optimize their operating conditions. A numerical analysis of potential barrier gating in time-of-flight spectrometers was also made. The results were used in the design of several small mass spectrometers. These were constructed and tested in a laboratory space simulator. Detailed experimental studies of a miniature cylindrical electrode time of flight mass spectrometer and of a miniature hemispherical electrode time of flight mass spectrometer were made. The extremely high sensitivity of these instruments and their ability to operate at D region pressures with an open source make them ideal instruments for D region ion composition measurements.

Kendall, B. R.↗

Whistle Gauge Measures Flow And Temperature

Simple, rugged gauge used to measure speed of flow and temperature of steam or other gas flowing through pipes of arbitrary diameter, from 1 to 28 in. or larger. Specially designed, instrumented whistle - has no moving parts, small, nonobstruction, operates at high temperature and pressure, and cleans itself. Does not operate at zero flow, but at moderate flows (tens of meters per second) generates intense sound for use in measurements. Consists of slanted ring groove of depth D and pressure taps in wall of pipe carrying flow to be measured. Resonant wavelength of sound generated by ring groove depends primarily on size and shape of groove and approximately equal to 4D.

Shakkottai, Parthasarathy↗

NASA Tech Briefs, May 2012

Topics covered include: An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently; On-Wafer Measurement of a Multi-Stage MMIC Amplifier with 10 dB of Gain at 475 GHz; Software to Control and Monitor Gas Streams; Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column; Anomaly Detection in Test Equipment via Sliding Mode Observers; Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems; Goldstone Solar System Radar Waveform Generator; Fast and Adaptive Lossless Onboard Hyperspectral Data Compression System; Iridium Interfacial Stack - IrIS; Downsampling Photodetector Array with Windowing; Optical Phase Recovery and Locking in a PPM Laser Communication Link; High-Speed Edge-Detecting Line Scan Smart Camera; Optical Communications Channel Combiner; Development of Thermal Infrared Sensor to Supplement Operational Land Imager; Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Histogrammatic Method for Determining Relative Abundance of Input Gas Pulse; Predictive Sea State Estimation for Automated Ride Control and Handling - PSSEARCH; LEGION: Lightweight Expandable Group of Independently Operating Nodes; Real-Time Projection to Verify Plan Success During Execution; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Web-Based Customizable Viewer for Mars Network Overflight Opportunities; Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations; Fabrication of an Absorber-Coupled MKID Detector; Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays; Method of Bonding Optical Elements with Near-Zero Displacement; Free-Mass and Interface Configurations of Hammering Mechanisms; Wavefront Compensation Segmented Mirror Sensing and Control; Long-Life, Lightweight, Multi-Roller Traction Drives for Planetary Vehicle Surface Exploration; Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications; Electrochemical Ultracapacitors Using Graphitic Nanostacks; Improved Whole-Blood-Staining Device; Monitoring Location and Angular Orientation of a Pill; Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity; Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars; High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle; PRTs and Their Bonding for Long-Duration, Extreme-Temperature Environments; Mid- and Long-IR Broadband Quantum Well Photodetector; 3D Display Using Conjugated Multiband Bandpass Filters; Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow; Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators; Dual-Compartment Inflatable Suitlock; Large-Strain Transparent Magnetoactive Polymer Nanocomposites; Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine; Time Distribution Using SpaceWire in the SCaN Testbed on ISS; and Techniques for Solution- Assisted Optical Contacting.

Source record↗

Unsteady design-point flow phenomena in transonic compressors

High-frequency response probes which had previously been used exclusively in the MIT Blowndown Facility were successfully employed in two conventional steady state axial flow compressor facilities to investigate the unsteady flowfields of highly loaded transonic compressors at design point operation. Laser anemometry measurements taken simultaneously with the high response data were also analyzed. The time averaged high response data of static and total pressure agreed quite well with the conventional steady state instrumentation except for flow angle which showed a large spread in values at all radii regardless of the type of instrumentation used. In addition, the time resolved measurements confirmed earlier test results obtained in the MIT Blowdown Facility for the same compressor. The results of these tests have further revealed that the flowfields of highly loaded transonic compressors are heavily influenced by unsteady flow phenomena. The high response measurements exhibited large variations in the blade to blade flow and in the blade passage flow. The observed unsteadiness in the blade wakes is explained in terms of the rotor blades' shed vorticity in periodic vortex streets. The wakes were modeled as two-dimensional vortex streets with finite size cores. The model fit the data quite well as it was able to reproduce the average wake shape and bi-modal probability density distributions seen in the laser anemometry data. The presence of vortex streets in the blade wakes also explains the large blade to blade fluctuations seen by the high response probes which is simply due to the intermittent sampling of the vortex street as it is swept past a stationary probe.

Gertz, J. B.↗