Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Renewable Penetration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Transient Physical Modelling for the Coupling of a High Temperature Gas Reactor with Thermal Energy Storage

Improving the flexibility of nuclear reactors to meet fluctuating demand on grids with high renewable energy generation penetration is key to improving reactor economics. Economic optimization using the code HERON gives maximum profit of coupling high temperature gas reactors (HTGRs) to thermal energy storage (TES) systems in the configuration shown in Figure 1 when following the demand in Figure 3. We look to model the physics of operation for a HTGR-TES using the HYBRID library in the code Modelica.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fundamental benchmarking of the discharge properties of negative electrodes in lead acid batteries

The unprecedented scale of energy storage deployment needed to allow high penetration of intermittent renewable energy sources into the electrical grid places significant economic cost and performance targets on battery technologies. Lead batteries, owing to their highly abundant and inexpensive raw materials, can be considered an important solution to grid storage as long as they achieve high material utilization, fast recharge rates, and long cycle life. To address the limitations in material utilization, we need to revisit the electrochemical processes during the discharge step and answer the following question: what are the fundamental limits of the discharge reaction? In this work we discuss how well-defined lead metal surfaces with nanometer scale roughness allow us to resolve the accessible discharge capacity for both faradaic and non-faradaic processes as a function of electrolyte concentration and in the presence of traditional additives. The direct connection between PbSO 4 layer morphology and discharge rates gives us important insights on the mechanism of discharge as related to the dissolution and passivation events. In conclusion, this work sets the stage for reimagining the design of lead batteries with implications to grid storage applications.

25 ENERGY STORAGE↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

The value of hydropower flexibility for electricity system decarbonization

Hydropower is an abundant, dispatchable, clean energy resource that will play an important role in supporting the clean energy transition. In particular, dispatchable hydropower can provide the operational flexibility that will be required in future systems with high variable renewable energy penetrations. However, the theoretical operational flexibility of hydropower can be restricted in practice by various non-power constraints. In this paper, we quantify how increasing the operational flexibility of dispatchable hydropower resources with reservoirs impacts least-cost generation portfolios and supports power system decarbonization. Specifically, we conduct a capacity expansion analysis of a two-zone system: a hydro-dominated region and a neighboring region with aggressive decarbonization targets that are represented by the United States Pacific Northwest and California respectively. We then introduce a quantifiable index for characterizing the operational flexibility of reservoir hydropower and assess how changes in this metric impact the system-optimal generation portfolio. We find that increasing hydropower flexibility leads to more investment in wind generation, less investment in natural gas generation, lower system costs, and lower system emissions. We further demonstrate a substitution effect between the grid services provided by flexible hydropower operation, increased transmission capacity on a congested line, and energy storage resources. Finally, we show that increasing the operational flexibility of hydropower increases the effective load carrying capability of both hydropower and wind resources. This research supports a more nuanced understanding of how hydropower can support electricity system decarbonization and may motivate reassessing the cost-benefit tradeoffs of non-power constraints that restrict operational flexibility.

Capacity expansion modeling↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Machine Learning-Assisted Distribution System Network Reconfiguration Problem

High penetration from volatile renewable energy resources in the grid and the varying nature of loads raise the need for frequent line switching to ensure the efficient operation of electrical distribution networks. Operators must ensure maximum load delivery, reduced losses, and the operation between voltage limits. However, computations to decide the optimal feeder configuration are often computationally expensive and intractable, making it unfavorable for real-time operations. This is mainly due to the existence of binary variables in the network reconfiguration optimization problem. To tackle this issue, we have devised an approach that leverages machine learning techniques to reshape distribution networks featuring multiple substations. This involves predicting the substation responsible for serving each part of the network. Hence, it leaves simple and more tractable Optimal Power Flow problems to be solved. This method can produce accurate results in a significantly faster time, as demonstrated using the IEEE 37-bus distribution feeder. Compared to the traditional optimization-based approaches, a feasible solution is achieved approximately ten times faster for all the tested scenarios.

deep neural networks↗

Electric Vehicles Charging Time Constrained Deliverable Provision of Secondary Frequency Regulation

Aggregation of electric vehicles (EVs) is a promising technique for providing secondary frequency regulation (SFR) in highly renewable energy-penetrated power systems. Equipped with energy storage devices, EV aggregation can provide reliable SFR. However, the main challenge is to guarantee reliable intra-interval SFR capacities and inter-interval delivery following the automatic generation control (AGC) signal. Furthermore, aggregated EV SFR provision will be further complicated by the EV charging time anxiety because SFR provision might extend EV's charging time. This paper proposes a deliverable EV SFR provision with a charging-time-constrained control strategy. First, a charging-time-constrained EV aggregation is proposed to address the uncertainty of EV capacity based on the state-space model considering the charging-time restriction of EV owners. Second, a real-time economic dispatch and time domain simulation (RTED-TDS) cosimulation framework is proposed to verify financial results and the dynamic performance of the EV SFR provision. Last, the proposed charging time-constrained EV aggregation is validated on the IEEE 39-bus system. In conclusion, the results demonstrate that with charging time-constrained EV aggregation, the dynamic performance of the system can be improved with a marginal increase in total cost. More importantly, the charging time constraint can be respected in the proposed SFR provision of the EV aggregation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Grid Vision: A U.S. Perspective - Chapter 1. Clean Grid Scenarios

Chapter 1: Clean Grid Scenarios serves as a broad introduction to the type of future power systems envisioned in the Clean Grid Vision: one with high penetrations of variable renewable energy generation (for example, more than 53% nationally and up to 73% in the Eastern Interconnection) and significant share of natural gas. Our study shows that the conterminous United States has adequate resources to support such systems with current technologies, and these systems can be operated cost-effectively to meet all sub-hourly demand and reserve requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development Support for NREL's System Advisor Model (SAM): Cooperative Research and Development, CRADA Number CRD-20-16998 (Final Report)

The variable nature of renewable generation, which depends on the sun shining and wind blowing for example, presents challenges for adequate and least-cost resource planning. The deployment of renewable generation assets is anticipated to increase due to various drivers, such as declining costs, favorable government policies, and increasing procurement by corporations and consumers. High levels of renewable penetration are anticipated to pose flexibility, reliability, and cost challenges to the electrical system. The development and implementation of new features into performance modeling software, such as the National Renewable Energy Laboratory's (NREL) System Advisor Model (SAM), is one way to help think through these challenges and develop appropriate strategies.

14 SOLAR ENERGY↗

Techno-Economic Studies for Pumped Storage Hydropower (Final CRADA Report)

The research focused on estimating the value of various services and contributions that pumped storage hydropower (PSH) provides to the grid, especially in locations characterized by high penetration of variable renewable energy resources. Under this CRADA, the Participant provided the Contractors with non-proprietary data and information on the proposed Banner Mountain PSH project that describe project’s technoeconomic and environmental characteristics, planned market and business models, and other relevant information necessary to describe the proposed project and its planned operations. The Contractors analyzed this information and performed various technoeconomic studies to estimate the value of different services and contributions that PSH project could provide to the grid. The outcome of this CRADA was a detailed technoeconomic analysis conducted in a comprehensive cost–benefit and decision analysis framework.

13 HYDRO ENERGY↗

Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗

Tri-Sectional Approximation of the Shortest Path to Long-Term Voltage Stability Boundary with Distributed Energy Resources

Ensuring long-term voltage stability is critical for reliable operations of power grids. High share of distributed energy resources (DERs) can create complicated system operation modes that may invalidate the traditional long-term voltage stability analysis based on typical operation modes. To address this challenge, this paper investigates how to compute the shortest path to the voltage stability boundary in the DER aggregated load space with large dispersion. Instead of working in the Euclidean space, we establish the analysis and computations on the algebraic power flow manifold to better capture the curvature change of the shortest path along the direction of losing stability. A modified optimal control framework is presented for obtaining the ground-truth of the smooth shortest path on the manifold. To efficiently and accurately solve for the shortest path, we further leverage the geometric features of the power flow manifold and propose a tri-sectional approximation model that is scalable for large-scale systems. Several numerical examples, up to the 1354-bus system, with different DER penetration levels and high dimensional renewable power injection variations are evaluated. The simulation results demonstrate that the tri-sectional approximation achieves high accuracy and efficiency to approximate the shortest path to the voltage stability boundary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Industrial Energy Storage Review

As the United States moves to net-zero carbon emission by 2050, a transition to renewable energy generation is required. However, the variable nature of renewable energy generation at high penetrations can cause imbalances in generation and transmission of electricity. These imbalances can be circumvented by the deployment of energy storage. Global industrial energy storage is projected to grow 2.6 times in the coming decades, from just over 60 GWh to 167 GWh in 2030. The challenge is to balance energy storage capabilities with the power and energy needs for particular industrial applications. Energy storage technologies can be classified by the form of the stored energy. The most common forms include thermal, chemical, electrochemical, and mechanical storage technologies. The most appropriate storage technology will depend on the unique energy needs of the industrial application. The purpose of this report is to provide a review of energy storage technologies relevant to the U.S. industrial sector, highlighting the applications in industry that will benefit from increased integration of energy storage, as well as the respective challenges and opportunities unique to integrating different storage technologies.

25 ENERGY STORAGE↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Availability Estimates of Low-Cost, Dispatch-Constrained Electricity (LDE)

This dataset accompanies the report "Potential Availability of and Supply Curves for Low-Cost, Dispatch-Constrained Electricity", which provides initial estimates of the quantity and availability of the potential low-cost, dispatch-constrained electricity (LDE) resource in the United States under scenarios with high variable renewable energy (VRE) penetrations. The analysis also estimates supply curves that can be used in subsequent analysis of the opportunity to use the LDE. The estimated LDE resource could be used for various applications that value low-cost electricity and can operate at reduced capacity factors, including electrolytic hydrogen production and carbon capture. The analysis accompanying this dataset was performed in 2018-2019 to support an analysis of "The Technical and Economic Potential of the H2@Scale Concept within the United States" ( https://www.nlr.gov/docs/fy21osti/77610.pdf ). This dataset includes the quantity of estimated LDE resource for each hour of the year in 2050, aggregated to both the national level and the ReEDS balancing area level. As described in the accompanying report, the ReEDS model was used to project the evolution of the power sector over time. Links to the mapping of ReEDS balancing areas to states and ReEDS balancing area shape files are provided. This dataset also includes the report figure data.

08 HYDROGEN↗

Robust VAR Capability Curve of DER with Uncertain Renewable Generation

Active distribution system with high penetration of inverter based distributed energy resources(DER), can be utilized for var-related ancillary services at the transmission side interface. In order to utilize the DER flexibility, transmission system operator must be presented the aggregated DER flexibility of distribution system. However, the uncertainty in renewable generation, questions the credibility of aggregated capability curve in practice. In this paper, we incorporate the uncertainty into aggregation process to develop capability curve while preserving the real physics (unbalance and lossy nature) of distribution system. The Resulting capability curve with the associated probability can be harnessed by the TSO for decision making for both planning and operation.

Kar, Aditya Shankar↗

Inertia Estimation Under High Penetration of Inverter-based Resources

Many types of renewable energy sources, especially solar and wind generation, are connected to the electric grid through power-electronic-based interfaces (inverters). These inverter-based resources (IBRs) are mechanically decoupled from the grid, which reduces system inertia and thus may compromise its stability and reliability. In this study, we examine the impact of high penetration of IBRs on the power grid’s inertia. To achieve this, we intentionally introduce disturbances into a simulation case study, such as a step load change, to observe and record the system’s frequency responses. This study offers a nuanced understanding of how the integration of IBRs affects grid stability, and it provides essential guidance for future grid management and resilience strategies.

Yadav, Ajay↗