Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Heat Loads Due to Small Penetrations in Multilayer Insulation Blankets

Abstract: This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass.

multilayer insulation↗

Active Control of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

The operating temperature of a loop heat pipe (LHP) with multiple evaporators is a function of the total heat load, heat load distribution among evaporators, condenser temperature and ambient temperature. Because of the many variables involved, the operating temperature also showed more hystereses than an LHP with a single evaporator. Tight temperature control can be achieved by controlling its compensation chamber (CC) temperatures at the desired set point. This paper describes a test program on active control of the operating temperature in an LHP with two evaporators and two condensers. Temperature control was achieved by heating one or both CC's. Tests performed included start-up, power cycle, sink temperature cycle, CC temperature cycle, and capillary limit. Test results show that, regardless one or two CC's were heated to the set point temperature, one of CC's was always flooded with liquid. The loop could operate successfully at the desired set point temperature under most conditions, including some fast transients. At low heat loads, however, the CC temperature could suddenly increase above the set point temperature, possibly due to a sudden change of the vapor content inside the evaporator core.

Ku, Jentung↗

Summary of the IAEA technical meeting on plasma disruptions and their mitigation

Here we summarize the contributions presented at the IAEA technical meeting on plasma disruptions and their mitigation, held virtually, 20–23 July 2020. The meeting brought together more than 120 experts from nuclear fusion research sites worldwide to discuss experimental, theoretical and modelling work in the field of plasma disruptions with special emphasis on developing a solid basis for possible disruption mitigation strategies in ITER and next generation fusion devices. The main topics of the meeting were: (i) disruption consequences, including electromagnetic loads, heat loads, and runaway electrons; (ii) disruption prediction and avoidance, including machine learning and physics-based approaches, and control aspects; and (iii) disruption mitigation, including shattered pellet injection, alternative techniques and general aspects of disruption mitigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Management Tools for Propulsion System Trade Studies and Analysis

Energy-related subsystems in modern aircraft are more tightly coupled with less design margin. These subsystems include thermal management subsystems, vehicle electric power generation and distribution, aircraft engines, and flight control. Tighter coupling, lower design margins, and higher system complexity all make preliminary trade studies difficult. A suite of thermal management analysis tools has been developed to facilitate trade studies during preliminary design of air-vehicle propulsion systems. Simulink blocksets (from MathWorks) for developing quasi-steady-state and transient system models of aircraft thermal management systems and related energy systems have been developed. These blocksets extend the Simulink modeling environment in the thermal sciences and aircraft systems disciplines. The blocksets include blocks for modeling aircraft system heat loads, heat exchangers, pumps, reservoirs, fuel tanks, and other components at varying levels of model fidelity. The blocksets have been applied in a first-principles, physics-based modeling and simulation architecture for rapid prototyping of aircraft thermal management and related systems. They have been applied in representative modern aircraft thermal management system studies. The modeling and simulation architecture has also been used to conduct trade studies in a vehicle level model that incorporates coupling effects among the aircraft mission, engine cycle, fuel, and multi-phase heat-transfer materials.

McCarthy, Kevin↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Cargo systems manual: Heat Pipe Performance (HPP) STS-66

The purpose of the cargo systems manual (CSM) is to provide a payload reference document for payload and shuttle flight operations personnel during shuttle mission planning, training, and flight operations. It includes orbiter-to-payload interface information and payload system information (including operationally pertinent payload safety data) that is directly applicable to the Mission Operations Directorate (MOD) role in the payload mission. The primary objectives of the heat pipe performance (HPP) are to obtain quantitative data on the thermal performance of heat pipes in a microgravity environment. This information will increase understanding of the behavior of heat pipes in space and be useful for application to design improvements in heat pipes and associated systems. The purpose of HPP-2 is to establish a complete one-g and zero-g data base for axial groove heat pipes. This data will be used to update and correlate data generated from a heat pipe design computer program called Grooved Analysis Program (GAP). The HPP-2 objectives are to: determine heat transport capacity and conductance for open/closed grooved heat pipes and different Freon volumes (nominal, under, and overcharged) using a uniform heat load; determine heat transport capacity and conductance for single/multiple evaporators using asymmetric heat loads; obtain precise static, spin, and rewicking data points for undercharged pipes; investigate heat flux limits (asymmetric heat loads); and determine effects of positive body force on thermal performance.

Napp, Robert↗

Temperature-Time Modeling of Spent Fuel Cladding in Dry Storage Casks

This report uses thermal and decay heat modeling to investigate spent fuel performance and the potential for cladding to anneal in dry storage conditions. Annealing is an important feature to investigate in SNF cladding because it has a direct relationship to cladding response in storage, transportation and disposal conditions. Annealed cladding may have lower strength than unannealed cladding, however its increased ductility would provide better protection against rupture in high strain rate situations such as severe accidents. These consequences are the driver for this work however are outside of the scope of this report. The modeling focused on three representative storage systems, the TN-32B, MAGNASTOR with TSC-37 canister, and NUHOMS AHSM with a 32PTH2 canister. This covers the vertical dual-purpose, vertical ventilated and horizontal ventilated casks respectively. Decay heat modeling using high and low enrichment assemblies was used to bound the decay heat curves that might be expected in dry storage. To bound the temperature relationship, the storage casks were modeled starting at the design basis heat loads with heat decaying through time. Although the results are bounding there is not an attempt to maximize conservatism, rather the intent to form a reasonable upper limit on temperature that will be broadly applicable to the U.S. cask fleet. This will allow materials testing to focus on relevant conditions for annealing that may affect the U.S. spent fuel inventory. The results show a clear dependence on heat load pattern in time in Figure S-1 and Figure S-2. This dependence is due to the different assembly decay heat curves for different assemblies in preferentially loaded casks. It shows the need for careful decay heat modeling when examining in service fuel temperatures that are less than the cask design basis heat load. The body of the report shows percent cladding cutoffs of 300°C and 350 °C as well. These results can be used to inform testing and conclusions about cladding performance through time and the potential for cladding annealing during dry storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing plasma face component thermal response to rotating 3D magnetic fields for SPARC tokamak

Thermal response simulations of plasma-facing components (PFCs) in the SPARC tokamak, performed with the HEAT code, show that three-dimensional (3D) heat loads resulting from stationary n=1 perturbations require highly radiative scenarios, with up to 95% of the power crossing the separatrix (P SOL ) being radiated, to maintain PFC temperatures within acceptable operational limits, whereas the application of slowly rotating 3D fields substantially reduces the thermal loads. The HEAT module, developed to predict heat loads from non-axisymmetric plasmas, is extended to model time-dependent heat flux patterns generated by rotating 3D fields, and a comprehensive thermal analysis is performed on PFCs subjected to both the maximum and minimum power loads, as well as to rotating heat flux distributions, to evaluate the temperature evolution for varying perturbation amplitudes and rotation frequencies. The extension of this analysis to 3D fields with toroidal mode number n=2 shows that this configuration leads to weaker localized heat flux peaks relative to the n=1 case, enabling safe operation with less than 80% of the power radiated when static 3D fields of low amplitude are applied, while using slowly rotating fields at higher amplitudes. These results indicate that n=2 perturbations are generally less detrimental to divertor power exhaust, emphasizing the strong dependence of divertor power exhaust on the characteristics of the applied 3D fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulated Reentry Heating by Torching

The two first order reentry heating parameters are peak heating flux (W/cm2) and peak heat load (kJ/cm2). Peak heating flux (and deceleration, gs) is higher for a ballistic reentry and peak heat load is higher for a lifting reentry. Manned vehicle reentries are generally lifting reentries at nominal 1-5 gs so that personnel will not be crushed by high deceleration force. A few off-nominal manned reentries have experienced 8 or more gs with corresponding high heating flux (but below nominal heat load). The Shuttle Orbiter reentries provide about an order of magnitude difference in peak heating flux at mid-bottom (TPS tiles, approximately 6 W/cm2 or 5 BTU/ft2- sec) and leading edge (RCC, approximately 60 W/cm2 or 50 BTU/ft2- sec). Orion lunar return and Mars sample lander are of the same order of magnitude as orbiter leading edge peak heat loads. Flight temperature measurements are available for some orbiter TPS tile and RCC locations. Return-to-Flight on-orbit tile-repair-candidate-material-heating performance was evaluated by matching propane torch heating of candidate-materials temperatures at several depths to orbiter TPS tile flight-temperatures. Char and ash characteristics, heat expansion, and temperature histories at several depths of the cure-in-place ablator were some of the TPS repair material performance characteristics measured. The final char surface was above the initial surface for the primary candidate (silicone based) material, in contrast to a receded surface for the Apollo-type ablative heat shield material. Candidate TPS materials for Orion CEV (LEO and lunar return), and for Mars sample lander are now being evaluated. Torching of a candidate ablator material, PICA, was performed to match the ablation experienced by the STARDUST PICA heat shield. Torching showed that the carbon fiberform skeleton in a sample of PICA was inhomogeneous in that sample, and allowed measurements (of the clumps and voids) of the inhomogeneity. Additional reentry heating-performance characterizations of high temperature insulation materials were performed.

Harvey, Gale A.↗

A Thermal Model for the Performance Analysis of Large Scale Spent Fuel Cooling Pond - 19173

This paper presents a thermal model for the performance analysis of a large scale cooling pond for the long term storage of spent nuclear fuel. The model has been developed using the knowledge gained from fundamental investigation using CFD and has been validated by comparing against reliable experimental and/or numerical data. It was then applied in the context of operation of a large scale pond to ascertain the sensitivity of various operational and environmental conditions. To develop the model, the water body along with the heating elements was considered as one zone and humid air inside the building as another zone, both of which are considered as well-mixed zones. Various input conditions namely, total heat load from the heat source, environmental temperature and relative humidity, ventilation rate, efficiency of the cooling tower, recirculation and make-up water flow rates have been programmed in the model. The statistical method AVONA has been used to assess the influence of the above variables. The results reveal that the efficiency of the cooling tower is the most influential parameter on the cooling performance of cooling pond within the considered values of heat load. It has also been found that the majority of the heat is taken by the recirculating water for very high heat load while the other modes of heat transfer are small but not insignificant. The model is capable of simulating the scenario of loss of cooling water and suggests that it can be used for managing a large pond efficiently as well as recovery from an accident situation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are conducted. Tests include heat load to one evaporator only, even heat loads to both evaporators and uneven heat load to both evaporators. Results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event Because the evaporator can tolerate vapor bubbles, the loop may continue to work and reach a new steady state at a higher operating temperature. The loop may even function with a modest increase in the heat load past the capillary limit With a heat load to only one evaporator, the capillary limit can be identified by rapid increases in the operating temperature and in the temperature difference between the evaporator and the CC. However, it is more difficult to tell when the capillary limit is exceeded if heat loads are applied to both evaporators. In all cases, the loop can recover by reducing the heat load to the loop.

Ku, Jentung↗

Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead of cryogens and measurement of the heat load with a calibrated heat conduction rod. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized Mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the aluminum coating on the Mylar might not be thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature, whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

Multilayer insulation↗