Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Head Movements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Laser-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

The invention relates generally to systems for determining the range of an object from a reference point and, in one embodiment, to laser-directed ranging systems useful in telerobotics applications. Digital processing techniques are employed which minimize the complexity and cost of the hardware and software for processing range calculations, thereby enhancing the commercial attractiveness of the system for use in relatively low-cost robotic systems. The system includes a video camera for generating images of the target, image digitizing circuitry, and an associated frame grabber circuit. The circuit first captures one of the pairs of stereo video images of the target, and then captures a second video image of the target as it is partly illuminated by the light beam, suitably generated by a laser. The two video images, taken sufficiently close together in time to minimize camera and scene motion, are converted to digital images and then compared. Common pixels are eliminated, leaving only a digital image of the laser-illuminated spot on the target. Mw centroid of the laser illuminated spot is dm obtained and compared with a predetermined reference point, predetermined by design or calibration, which represents the coordinate at the focal plane of the laser illumination at infinite range. Preferably, the laser and camera are mounted on a servo-driven platform which can be oriented to direct the camera and the laser toward the target. In one embodiment the platform is positioned in response to movement of the operator's head. Position and orientation sensors are used to monitor head movement. The disparity between the digital image of the laser spot and the reference point is calculated for determining range to the target. Commercial applications for the system relate to active range-determination systems, such as those used with robotic systems in which it is necessary to determine the, range to a workpiece or object to be grasped or acted upon by a robot arm end-effector in response to commands generated by an operator. In one embodiment, the system provides a real-time image of the target for the operator as the robot approaches the object. The system is also adapted for use in virtual reality systems in which a remote object or workpiece is to be acted upon by a remote robot arm or other mechanism controlled by an operator.

Wells, Dennis L.↗

Antimotion sickness drugs for aerospace

Slow rotation rooms used to simulate artificial gravity for testing head movements of humans previously administered antimotion sickness drugs

MOTION SICKNESS↗

The perception of heading during eye movements

Warren and Hannon (1988, 1990), while studying the perception of heading during eye movements, concluded that people do not require extraretinal information to judge heading with eye/head movements present. Here, heading judgments are examined at higher, more typical eye movement velocities than the extremely slow tracking eye movements used by Warren and Hannon. It is found that people require extraretinal information about eye position to perceive heading accurately under many viewing conditions.

Royden, Constance S.↗

Laboratory and in-flight experiments to evaluate 3-D audio display technology

Laboratory and in-flight experiments were conducted to evaluate 3-D audio display technology for cockpit applications. A 3-D audio display generator was developed which digitally encodes naturally occurring direction information onto any audio signal and presents the binaural sound over headphones. The acoustic image is stabilized for head movement by use of an electromagnetic head-tracking device. In the laboratory, a 3-D audio display generator was used to spatially separate competing speech messages to improve the intelligibility of each message. Up to a 25 percent improvement in intelligibility was measured for spatially separated speech at high ambient noise levels (115 dB SPL). During the in-flight experiments, pilots reported that spatial separation of speech communications provided a noticeable improvement in intelligibility. The use of 3-D audio for target acquisition was also investigated. In the laboratory, 3-D audio enabled the acquisition of visual targets in about two seconds average response time at 17 degrees accuracy. During the in-flight experiments, pilots correctly identified ground targets 50, 75, and 100 percent of the time at separation angles of 12, 20, and 35 degrees, respectively. In general, pilot performance in the field with the 3-D audio display generator was as expected, based on data from laboratory experiments.

Ericson, Mark↗

Enhanced Video-Oculography System

A previously developed video-oculography system has been enhanced for use in measuring vestibulo-ocular reflexes of a human subject in a centrifuge, motor vehicle, or other setting. The system as previously developed included a lightweight digital video camera mounted on goggles. The left eye was illuminated by an infrared light-emitting diode via a dichroic mirror, and the camera captured images of the left eye in infrared light. To extract eye-movement data, the digitized video images were processed by software running in a laptop computer. Eye movements were calibrated by having the subject view a target pattern, fixed with respect to the subject s head, generated by a goggle-mounted laser with a diffraction grating. The system as enhanced includes a second camera for imaging the scene from the subject s perspective, and two inertial measurement units (IMUs) for measuring linear accelerations and rates of rotation for computing head movements. One IMU is mounted on the goggles, the other on the centrifuge or vehicle frame. All eye-movement and head-motion data are time-stamped. In addition, the subject s point of regard is superimposed on each scene image to enable analysis of patterns of gaze in real time.

Moore, Steven T.↗

Cross-axis adaptation of torsional components in the yaw-axis vestibulo-ocular reflex

The three pairs of semicircular canals within the labyrinth are not perfectly aligned with the pulling directions of the six extraocular muscles. Therefore, for a given head movement, the vestibulo-ocular reflex (VOR) depends upon central neural mechanisms that couple the canals to the muscles with the appropriate functional gains in order to generate a response that rotates the eye the correct amount and around the correct axis. A consequence of these neural connections is a cross-axis adaptive capability, which can be stimulated experimentally when head rotation is around one axis and visual motion about another. From this visual-vestibular conflict the brain infers that the slow-phase eye movement is rotating around the wrong axis. We explored the capability of human cross-axis adaptation, using a short-term training paradigm, to determine if torsional eye movements could be elicited by yaw (horizontal) head rotation (where torsion is normally inappropriate). We applied yaw sinusoidal head rotation (+/-10 degrees, 0.33 Hz) and measured eye movement responses in the dark, and before and after adaptation. The adaptation paradigm lasted 45-60 min, and consisted of the identical head motion, coupled with a moving visual scene that required one of several types of eye movements: (1) torsion alone (-Roll); (2) horizontal/torsional, head right/CW torsion (Yaw-Roll); (3) horizontal/torsional, head right/CCW torsion (Yaw+Roll); (4) horizontal, vertical, torsional combined (Yaw+Pitch-Roll); and (5) horizontal and vertical together (Yaw+Pitch). The largest and most significant changes in torsional amplitude occurred in the Yaw-Roll and Yaw+Roll conditions. We conclude that short-term, cross-axis adaptation of torsion is possible but constrained by the complexity of the adaptation task: smaller torsional components are produced if more than one cross-coupling component is required. In contrast, vertical cross-axis components can be easily trained to occur with yaw head movements.

Non-NASA Center↗

Oculomotor Behavior Metrics Change According to Circadian Phase and Time Awake

There is a need for non-invasive, objective measures to forecast performance impairment arising from sleep loss and circadian misalignment, particularly in safety-sensitive occupations. Eye-tracking devices have been used in some operational scenarios, but such devices typically focus on eyelid closures and slow rolling eye movements and are susceptible to the intrusion of head movement artifacts. We hypothesized that an expanded suite of oculomotor behavior metrics, collected during a visual tracking task, would change according to circadian phase and time awake, and could be used as a marker of performance impairment.

sleep deprivation↗

Vestibular convergence patterns in vestibular nuclei neurons of alert primates

Sensory signal convergence is a fundamental and important aspect of brain function. Such convergence may often involve complex multidimensional interactions as those proposed for the processing of otolith and semicircular canal (SCC) information for the detection of translational head movements and the effective discrimination from physically congruent gravity signals. In the present study, we have examined the responses of primate rostral vestibular nuclei (VN) neurons that do not exhibit any eye movement-related activity using 0.5-Hz translational and three-dimensional (3D) rotational motion. Three distinct neural populations were identified. Approximately one-fourth of the cells exclusively encoded rotational movements (canal-only neurons) and were unresponsive to translation. The canal-only central neurons encoded head rotation in SCC coordinates, exhibited little orthogonal canal convergence, and were characterized with significantly higher sensitivities to rotation as compared to primary SCC afferents. Another fourth of the neurons modulated their firing rates during translation (otolith-only cells). During rotations, these neurons only responded when the axis of rotation was earth-horizontal and the head was changing orientation relative to gravity. The remaining one-half of VN neurons were sensitive to both rotations and translations (otolith + canal neurons). Unlike primary otolith afferents, however, central neurons often exhibited significant spatiotemporal (noncosine) tuning properties and a wide variety of response dynamics to translation. To characterize the pattern of SCC inputs to otolith + canal neurons, their rotational maximum sensitivity vectors were computed using exclusively responses during earth-vertical axis rotations (EVA). Maximum sensitivity vectors were distributed throughout the 3D space, suggesting strong convergence from multiple SCCs. These neurons were also tested with earth-horizontal axis rotations (EHA), which would activate both vertical canals and otolith organs. However, the recorded responses could not be predicted from a linear combination of EVA rotational and translational responses. In contrast, one-third of the neurons responded similarly during EVA and EHA rotations, although a significant response modulation was present during translation. Thus this subpopulation of otolith + canal cells, which included neurons with either high- or low-pass dynamics to translation, appear to selectively ignore the component of otolith-selective activation that is due to changes in the orientation of the head relative to gravity. Thus contrary to primary otolith afferents and otolith-only central neurons that respond equivalently to tilts relative to gravity and translational movements, approximately one-third of the otolith + canal cells seem to encode a true estimate of the translational component of the imposed passive head and body movement.

Non-NASA Center↗

Self-motion perception: assessment by real-time computer-generated animations

We report a new procedure for assessing complex self-motion perception. In three experiments, subjects manipulated a 6 degree-of-freedom magnetic-field tracker which controlled the motion of a virtual avatar so that its motion corresponded to the subjects' perceived self-motion. The real-time animation created by this procedure was stored using a virtual video recorder for subsequent analysis. Combined real and illusory self-motion and vestibulo-ocular reflex eye movements were evoked by cross-coupled angular accelerations produced by roll and pitch head movements during passive yaw rotation in a chair. Contrary to previous reports, illusory self-motion did not correspond to expectations based on semicircular canal stimulation. Illusory pitch head-motion directions were as predicted for only 37% of trials; whereas, slow-phase eye movements were in the predicted direction for 98% of the trials. The real-time computer-generated animations procedure permits use of naive, untrained subjects who lack a vocabulary for reporting motion perception and is applicable to basic self-motion perception studies, evaluation of motion simulators, assessment of balance disorders and so on.

Non-NASA Center↗

The role of reafference in recalibration of limb movement control and locomotion

The reafference model has frequently been used to explain spatial constancy during eye and head movements. We have found that its basic concepts also form part of the information processing necessary for the control and recalibration of reaching movements. Reaching was studied in a novel force environment--a rotating room that creates centripetal forces of the type that could someday substitute for gravity in space flight, and Coriolis forces which are side effects of rotation. We found that inertial, noncontacting Coriolis forces deviate the path and endpoint of reaching movements, a finding that shows the inadequacy of equilibrium position models of movement control. Repeated movements in the rotating room quickly lead to normal movement patterns and to a failure to perceive the perturbing forces. The first movements made after rotation stops, without Coriolis forces present, show mirror-image deviations and evoke perception of a perturbing force even though none is present. These patterns of sensorimotor control and adaptation can largely be explained on the basis of comparisons of efference copy, reafferent muscle spindle, and cutaneous mechanoreceptor signals. We also describe experiments on human locomotion using an apparatus similar to that which Mittelstaedt used to study the optomotor response of the Eristalis fly. These results show that the reafference principle relates as well to the perception of the forces acting on and exerted by the body during voluntary locomotion.

NASA Discipline Neuroscience↗

On the externalization of auditory images

An acoustic image is said to be 'externalized' if the sound source appears to the listener to lie outside the head. The purpose of the note is to put the phenomenon of externalization of auditory images in proper perspective. It points out that the listener's pinnae (the so-called 'pinna factor') is only one of many factors that determine the extent to which a sound image is externalized and that the relative importance of these factors is not yet clear. The note begins with some general comments on externalization. It then considers the effect of reverberation. It examines head movements, visual effects, and other factors. It concludes with remarks on externalization's relation to head-related transfer functions (HRTFs), the pinna factor, and improved experimental instrumentation.

Durlach, N. I.↗

Altered sensory-motor control of the head as an etiological factor in space-motion sickness

Mechanical unloading during head movements in weightlessness may be an etiological factor in space-motion sickness. We simulated altered head loading on Earth without affecting vestibular stimulation by having subjects wear a weighted helmet. Eight subjects were exposed to constant velocity rotation about a vertical axis with direction reversals every 60 sec. for eight reversals with the head loaded and eight with the head unloaded. The severity of motion sickness elicited was significantly higher when the head was loaded. This suggests that altered sensory-motor control of the head is also an etiological factor in space-motion sickness.

NASA Discipline Neuroscience↗

Head and Trunk Movement Control During Locomotion After Long-Duration Spaceflight

Exposure to the microgravity environment encountered during spaceflight induces adaptive alteration in sensorimotor function that leads to postflight disturbances in locomotor control. Head and trunk movement control plays a central role in maintaining gaze stability and in providing a stable reference system to permit spatial navigation in a complex and constantly varying environment. The goal of the present study was to investigate the effects of long-duration spaceflight (3-6 months) on head and trunk movement control during postflight terrestrial locomotion. Before and after spaceflight, subjects walked on a motorized treadmill while performing a challenging gaze stabilization task requiring number recognition. Head and trunk kinematic data were collected with a video-based motion analysis system. Analysis of roll, pitch and yaw head and trunk movements during treadmill walking revealed postflight alterations in head and trunk movement control in all three planes of motion. Subjects also experienced oscillopsia during postflight walking which led to impairment in performance of the number recognition task. These data indicate that exposure to long-duration space flight causes alteration in head and trunk movement control during postflight locomotion. These changes have implications for the control of gaze and maintenance of dynamic stability during walking after long-duration spaceflight.

Bloomberg, Jacob J.↗

Recommendations for Refinement and Validation of Intermittent Artificial Gravity

The IMAG Pilot Study, recently completed at the University of Texas Medical Branch, filled in the second major gap in knowledge standing in the way of development of a practical Short Radius Centrifuge (SRC) and the use of Artificial Gravity (AG) as a multi-system countermeasure to combat the deconditioning associated with extended weightlessness. (The first challenge, to adapt rapidly rotating subjects to permit unlimited head movements without excessive motion sickness, was achieved in a series of studies at MIT involving incremental increases in head and centrifuge velocity.) It remained to be demonstrated that intermittent exposure to AG, at only one hour per day for 21 days, would have any positive effect on slowing or eliminating of deconditioning. Bed-rested normal subjects were used as a ground analog for astronauts in weightlessness. The results are clearly positive for the key physiological systems of interest: cardiovascular, muscle, and bone. No functionally relevant changes were observed in immune, cognitive, or sensory-motor function. Furthermore, we found that our initial concerns about the inability of deconditioned subjects to withstand daily centrifugation without syncope were misplaced. These encouraging initial results clearly support the further development of AG protocols. We recommend, as the next steps, the integration of a controlled exercise device on the SRC to determine the synergy between AG and exercise. Coupled with appropriate exercise device(s) the AG protocol will be tuned to-ward an optimal prescription for minimum exposure duration and frequency, maximum AG level and SRC speed.. Performance of these next steps will require extensive use of bed-rest/centrifuge facilities and eventually validation using an SRC in space. A space SRC could be placed in the ISS or on a planetary surface.

Young, Lauren R.↗

STS-78 Flight Day 10

On this tenth day of the STS-78 mission, the flight crew, Cmdr. Terence T. Henricks, Pilot Kevin R. Kregel, Payload Cmdr. Susan J. Helms, Mission Specialists Richard M. Linnehan, Charles E. Brady, Jr., and Payload Specialists Jean-Jacques Favier, Ph.D. and Robert B. Thirsk, M.D., continue to perform in a nearly flawless fashion. The crew is shown completing another of four tests focusing on the effects of microgravity on the vestibular system in the inner ear. In space, the vestibular system sometimes becomes confused as to which way is up and down, leading to nausea and disorientation. Using specially designed head gear to monitor head movement and eye coordination, Linnehan, Brady, Favier, Thirsk and Helms performed tests throughout their shifts to determine how the head and eyes track visual and motion targets in microgravity. The study is providing scientists with important information about the crews' ability to adapt to microgravity.

Source record↗