The Microbiome Project: Hospitals
Bacteria may actually be beneficial to hospitals.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Bacteria may actually be beneficial to hospitals.
This brochure details the sustainable and green aspects of the LEED Platinum-designed Kiowa County Memorial Hospital in Greensburg, Kansas.
This case study describes how NorthBay VacaValley Hospital completed lighting retrofits to its 150,000-square-foot parking lot with help from the California Lighting Technology Center at UC Davis, resulting in 65% energy savings.
MNSRs (Miniature Neutron Source Reactor) are low power research reactors designed and manufactured by China Institute of Atomic Energy (CIAE). MNSRs are mainly used for NAA, training and teaching, testing of nuclear instrumentation. The first MNSR, the prototype MNSR, was put into operation in 1984, later, eight other MNSRs had been built both at home and abroad. For MNSRs, highly enriched uranium (90%) is used as the fuel material. The In-Hospital Neutron Irradiator (IHNI) is designed for Boron Neutron Capture Therapy (BNCT) based on Miniature Neutron Source Reactor(MNSR). On both sides of the reactor core, there are two neutron beams, one is thermal neutron beam, and the other opposite to the thermal beam, is epithermal neutron beam. A small thermal neutron beam is specially designed for the measurement of blood boron concentration by the prompt gamma neutron activation analysis (PGNAA). In this paper, the experimental results of critical mass worth of the top Be reflectors worth of the control rod, neutron flux distribution and other components worth were measured, the experiment was done on the Zero Power Experiment equipment of MNSR. (author)
Purpose: To describe and review the radiotherapy (RT) treatment planning and delivery techniques used for pediatric sarcoma patients at St. Jude Children's Research Hospital. The treatment characteristics serve as a baseline for future comparison with developing treatment modalities. Patients and Methods: Since January 2003, we have prospectively treated pediatric and young-adult patients with soft-tissue and bone sarcomas on an institutional Phase II protocol evaluating local control and RT-related treatment effects from external-beam RT (conformal or intensity-modulated RT; 83.4%), low-dose-rate brachytherapy (8.3%), or both (8.3%). Here we describe the treatment dosimetry and delivery parameters of the initial 72 patients (median, 11.6 years; range, 1.4-21.6 years). Results: Cumulative doses from all RT modalities ranged from 41.4 to 70.2 Gy (median, 50.4 Gy). Median D{sub 95} and V{sub 95} of the planning target volume of external-beam RT plans were, respectively, 93.4% of the prescribed dose and 94.6% of the target volume for the primary phase and 97.8% and 99.2% for the cone-down/boost phase. The dose-volume histogram statistics for 27 critical organs varied greatly. The spinal cord in 13 of 36 patients received dose >45 Gy (up to 52 Gy in 1 cc) because of tumor proximity. Conclusions: Planning and delivery of complex multifield external beam RT is feasible in pediatric patients with sarcomas. Improvements on conformity and dose gradients are still desired in many cases with sensitive adjacent critical structures. Long-term follow-up will determine the risk of local failure and the benefit of normal tissue avoidance for this population.
The application of radioisotopes and radiation sources in medical diagnosis and therapy is an important issue. Physicians can use radioisotopes to diagnose and treat diseases. Methods of treatment, conditioning and management of low level radioactive wastes from the use of radiation sources and radioisotopes in hospitals and nuclear medicine application, are described. Solid Radioactive waste with low-level activity after accumulation, minimization, segregation and measurement, are burned or compressed in a compactor according to the international standards. Conditioned drums are transported to the interim storage site at the Egyptian Atomic Energy Authority (EAEA) represented in Hot Labs and Waste Management Center (HLWMC) for storage and monitoring. (authors)
Purpose. To identify pretreatment predictors of procedural costs in percutaneous and surgical interventions for intermittent claudication due to aortoiliac and/or femoropopliteal disease. Methods. A retrospective study was conducted in 97 consecutive patients who underwent percutaneous or surgical interventions over 15 months at a tertiary care center. Nineteen clinical predictive variables were collected at baseline. Procedural costs (outcome) were assessed from the perspective of the hospital by direct calculation, not based on ratios of costs-to-charges. A multivariable regression model was built to identify significant cost predictors. Follow-up information was obtained to provide multidimensional assessment of clinical outcome, including technical success (arteriographic score) and clinical result (changes in ankle-brachial pressure index; cumulative patency, mortality, and complication rates). Results. The linear regression model shows that procedural costs per patient are 25% lower in percutaneous patients (versus surgical), 42% lower for patients without rest pain than for those with, 28% lower if treated lesions are unilateral (versus bilateral), 12% lower if the treated lesion is stenotic rather than occlusive, 34% higher in sedentary patients, and 11% higher in patients with a history of cardiac disease. After a mean clinical follow-up >2 years, between-group differences between percutaneous and surgical patients were small and of limited significance in all dimensions of clinical outcome. Conclusion. Predictors of clinical outcome are different from predictors of costs, and one should include both types of variables in the decision-making process. The choice of percutaneous versus surgical strategy, the presence of rest pain, and the bilaterality of the culprit lesions were the main pretreatment determinants of procedural costs. When possible choices of treatment strategy overlap, percutaneous treatment should provide an acceptable result that is less expensive (although not equal to surgery)
Lack of access to reliable energy is a major concern for countries in sub-Saharan Africa. The national grids are unable to consistently satisfy demand. Therefore, users turn to distributed generation systems in the form of back-up generators. However, such systems are usually designed based on a rule of thumb. We employ a mixed-integer linear programming model that considers several options such as renewable energy, combined heat and power, and storage technologies, in addition to those on-site, to provide optimal design and dispatch decisions that minimize total cost. We apply this model to a case study for a hospital in South Africa, considering its need for reliable electricity in light of multiple outages that might occur over the course of a year, as well as its high heating and cooling loads. Our results show that optimal design and dispatch decisions for the distributed generation system address reliability challenges, regardless of the time at which they occur. And, these solutions yield millions of dollars in savings, suggesting that technologies such as the absorption chiller may be overlooked in typical designs; its integration can reduce demand charges even in the absence of combined heat and power. We show that total cost is most sensitive to changes in site electrical demand, followed by capital cost, fuel cost, photovoltaic production, and monthly demand charges; changes in fuel cost primarily affect system sizes of combined heat and power and the absorption chiller, while photovoltaic system size is more sensitive to the changes in capital and fuel costs, photovoltaic resource availability, and hourly electrical demand. Finally, an outage simulator demonstrates the ability of our optimized system to sustain with no interruptions in power five-hour outages with probability 1.0 and ten-hour outages with probability 0.65, significant improvements over 0.5 and 0.0, respectively, under a business-as-usual case.
Highlights: • None of the Legionella strains isolated showed resistance to the antibiotics tested. • Rifampicin was the most active antibiotic against all Legionella strains isolated. • All Legionella strains inhibited by low concentrations of macrolides and fluoroquinolones. Legionellosis’ treatment failures have been recently reported showing the possibility of resistance development to traditional therapy, especially in healthcare related disease cases. Environmental impact of antibiotic residues, especially in hospital waters, may act on the resistome of Legionella resulting in developing resistance mechanisms.
Highlights: • Unconventional natural gas development may be linked to pediatric asthma. • Specific air pollutants from drilling emissions may be driving these associations. • Associations remain for up to eight years after drilling begins in a community. Pediatric asthma is a common chronic condition that can be exacerbated by environmental exposures, and unconventional natural gas development (UNGD) has been associated with decreased community air quality. This study aims to quantify the association between UNGD and pediatric asthma hospitalizations.
Purpose: To present the results of uveal melanomas treated at Nice Teaching Hospital. Methods and Materials: This retrospective study included 886 consecutive patients referred to our clinic for the treatment of uveal melanomas by proton beam radiotherapy from June 1991 to December 2007. Survival rates were determined by using Kaplan-Meier estimates, and prognostic factors were evaluated using the log-rank test or Cox model. Results: The number (percent total) of subjects staged according to the TNM classification system (6th edition) of malignant tumors included 39 stage T1 (4.4%), 420 stage T2 (47.40%), 409 stage T3 (46.16%), and 18 stage T4 (2.03%) patients. The median follow-up was 63.7 months. The Kaplan-Meier overall survival rate at 5 years according to the sixth edition TNM classification was 92% for T1, 89% for T2, 67% for T3, and 62% for T4; and at 10 years, 86% for T1, 78% for T2, 43% for T3, and 41% for T4. Five factors were found to be associated with an increased death rate: advanced age, tumor thickness, largest tumor basal diameter, tumor volume, and tumor volume-to-eyeball volume ratio. The metastasis-free survival rates were 88.3 % at 5 years and 76.4 % at 10 years. The local control rates were 93.9% at 5 years and 92.1% at 10 years. The ocular conservation rates were 91.1% at 5 years and 87.3% at 10 years. Conclusions: We report the results of a large series of patients treated for uveal melanomas with a very long follow-up. Despite the large tumor volume treated, our results were similar to previously published findings relating to proton beam therapy.
Purpose: Long- and short-course radiotherapy have similar outcomes in the treatment of spinal metastases. Long-course radiotherapy is recommended for patients with good predicted survival to reduce the risk of in-field recurrence, whereas short-course radiotherapy is used for those with poor predicted survival. Therefore, prediction of prognosis and local control is required for selecting the optimal course of radiotherapy. Methods and Materials: The subjects were 603 patients with spinal metastases who received radiotherapy at the Shizuoka Cancer Center Hospital between September 2002 and February 2007. Factors associated with survival and local control were retrospectively investigated by multivariate analyses. Local recurrence was defined as regrowth within the irradiated field or exacerbation of symptoms such as pain and motor deficits. Results: Of the 603 patients, 555 (92%) were followed for 12 months or until death. The survival rates after 6, 12, and 24 months were 50%, 32%, and 19%, respectively, with a median survival of 6.2 months. The median survival periods after long- and short-course radiotherapy were 7.9 and 1.8 months, respectively. In multivariate analysis, primary tumor site, good performance status, absence of previous chemotherapy, absence of visceral metastasis, single bone metastasis, younger age, and nonhypercalcemia were associated with good survival. The local control rates after 6, 12, and 24 months were 91%, 79%, and 69%, respectively, and non-mass-type tumor, breast cancer, and absence of previous chemotherapy were predictors of good local control. Conclusions: Identification of factors associated with good local control and survival may allow selection of an optimal radiotherapy schedule for patients with spinal metastases.
Purpose: To illustrate some of the potential pitfalls of cranial stereotactic radiosurgery (SRS) and its planning based on prospectively gathered data from a 17-year experience at the Royal Adelaide Hospital. Methods and Materials: More than 250 treatments have been planned since 1993 using previously described standard SRS techniques for intracranial benign and malignant lesions. Results: Five case studies are presented (1 meningioma, 1 acoustic neuroma, 2 solitary brain metastasis, 1 arteriovenous malformation), each of which demonstrates at least one salutary lesson. Conclusions: Because SRS delivers a highly conformal dose distribution, it is unforgiving of any geographic miss due to inaccurate outlining and thus dependent on neuroradiological expertise and collaboration. There are also potentially significant implications of misdiagnosis in SRS cases without histological proof-in particular, presumed brain metastases.
Purpose: To retrospectively analyze the beam approaches used in gantry-based proton treatments, and to reassess the practical advantages of the gantry, compared with beam approaches that are achievable without a gantry, in the context of present-day technology. Methods and Materials: We reviewed the proton therapy plans of 4332 patients treated on gantries at our hospital, delivered by the double scattering technique (n=4228) and, more recently, pencil beam scanning (PBS) (n=104). Beam approaches, relative to the patient frame, were analyzed individually to identify cases that could be treated without a gantry. Three treatment configurations were considered, with the patient in lying position, sitting position, or both. The FIXED geometry includes a fixed horizontal portal. The BEND geometry enables a limited vertical inflection of the beam by up to 20°. The MOVE geometry allows for flexibility of the patient head and body setup. Results: The percentage of patients with head and neck tumors that could be treated without a gantry using double scattering was 44% in FIXED, 70% in 20° BEND, and 100% in 90° MOVE. For torso regions, 99% of patients could be treated in 20° BEND. Of 104 PBS treatments, all but 1 could be reproduced with FIXED geometry. The only exception would require a 10° BEND capability. Note here that the PBS treatments were applied to select anatomic sites, including only 2 patients with skull-base tumors. Conclusions: The majority of practical beam approaches can be realized with gantry-less delivery, aided by limited beam bending and patient movements. Practical limitations of the MOVE geometry, and treatments requiring a combination of lying and sitting positions, may lower the percentage of head and neck patients who could be treated without a gantry. Further investigation into planning, immobilization, and imaging is needed to remove the practical limitations and to facilitate proton treatment without a gantry.
Patients with gastrointestinal (GI) cancer frequently experience unplanned hospitalizations, but predictive tools to identify high-risk patients are lacking. We developed a machine learning model to identify high-risk patients.
Accurate forecasts can enable more effective public health responses during seasonal influenza epidemics. For the 2021–22 and 2022–23 influenza seasons, 26 forecasting teams provided national and jurisdiction-specific probabilistic predictions of weekly confirmed influenza hospital admissions for one-to-four weeks ahead. Forecast skill is evaluated using the Weighted Interval Score (WIS), relative WIS, and coverage. Six out of 23 models outperform the baseline model across forecast weeks and locations in 2021–22 and 12 out of 18 models in 2022–23. Averaging across all forecast targets, the FluSight ensemble is the 2nd most accurate model measured by WIS in 2021–22 and the 5th most accurate in the 2022–23 season. Forecast skill and 95% coverage for the FluSight ensemble and most component models degrade over longer forecast horizons. In this work we demonstrate that while the FluSight ensemble was a robust predictor, even ensembles face challenges during periods of rapid change.
The importance of social components of health has been emphasized both in epidemiology and public health. This paper highlights the significant impact of social components on health outcomes in a novel way. Introducing the concept of sociomarkers, which are measurable indicators of social conditions in which a patient is embedded, we employed a machine learning approach that uses both biomarkers and sociomarkers to identify asthma patients at risk of a hospital revisit after an initial visit with an accuracy of 66%. The analysis has been performed over an integrated dataset consisting of individual-level patient information such as gender, race, insurance type, and age, along with ZIP code-level sociomarkers such as poverty level, blight prevalence, and housing quality. Using this uniquely integrated database, we then compare the traditional biomarker-based risk model and the sociomarker-based risk model. A biomarker-based predictive model yields an accuracy of 65% and the sociomarkerbased model predicts with an accuracy of 61%. Without knowing specific symptom-related features, the sociomarker-based model can correctly predict two out of three patients at risk. We systematically show that sociomarkers play an important role in predicting health outcomes at the individual level in pediatric asthma cases. Additionally, by merging multiple data sources with detailed neighborhood-level data, we directly measure the importance of residential conditions for predicting individual health outcomes.
To evaluate the measured of all photon beam data of first Varian True Beam version 2.0 slim model, recently commissioned at Nordland Hospital Trust, Bodø. To compare and evaluate the possibility of beam matching with the Clinac2300, for the energies of 6MV and 15 MV. Materials/Methods: Measurements of PDD, OAR, and Output factors were realized with the IBA Blue-phantom with different detectors and evaluated between them for all photon energies: 6MV, 15MV, 6MV FFF and 10MV FFF. The ionization chambers used were Pin Point CC01, CC04, Semiflex CC13 and photon diode by Iba dosimetry. The data were processed using Beizer algorithm with a resolution of 1 mm. The measured depth dose curves, diagonals, OAR, and output factors were imported into Eclipse in order to calculate beam data for the anisotropic analytical algorithm (AAA version 10.0.28) for both the dataset measured with CC04 and CC13 and compared. The model head of 23EX was selected as the most near model to True Beam as a restriction of our version of Aria. It was seen that better results were achieved with the CC04 measured data as a result of better resolution. For the biggest field after 10 cm depth a larger difference is seen between measured and calculated for both dataset, but it is within the criteria for acceptance. Results: The Beam analysis criteria of 2 mm at 50% dose is achieved for all the fields accept for 40x40 that is within 3%. Depth difference at maximum dose is within 1 mm for all the fields and dose difference at 100 mm and 200 mm is lower than 1% for or all the fields. The PDD between two machines for all the fields differ after Dmax with less than 1%. For profiles in the field zone and outside field the difference is within 1% for all the fields. In the penumbra region the difference is from 2% up to 12% for big fields. As for diagonals they differ as a result of the head construction at the edge of the field and the penumbra region. The output factors differ for big fields within 5% and for the small fields within 3%. MU and dose distribution does not change for plans recalculated with the new modeled machine.