Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT LOSSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

A Unique Facility For Metabolic and Thermoregulatory Studies

A unique exercise facility has been developed and used to perform tipper body ergometry tests for space applications. Originally designed to simulate the muscular, cardiovascular and thermoregulatory responses to working in zero gravity, this facility may be used to conduct basic thermoregulatory investigations applicable to multiple sclerosis patients. An environmental chamber houses the tipper body ergometer and permits control of temperature, air now and humidify. The chamber is a closed system and recirculate-s air after conditioning if. A Cybex Lipper body ergometer has been mounted horizontally on the wall of the environmental chamber. In this configuration, the subject lies underneath the arm crank on a supine seat in order to turn the crank. The supine seat can be removed in order to introduce other equipment into the chamber such as a stool to allow upright arm cranking, or a treadmill to allow walk-run experiments. Physiological and environmental signals are fed into a Strawberry Tree data acquisition system while being monitored and logged using the Workbench software program. Physiological monitoring capabilities include 3-lead EKG using an H-P patient monitor, 5 site skin temperature and core temperature using YSI thermistors, and O2 consumption and CO2 production using AMFTFK Applied Electrochemistry analyzers and sensors. This comprehensive data acquisition set tip allows for calculation of various thermoregulatory indices including heat storage, evaporative heat loss, latent heat loss, and metabolic rate. The current system is capable of adding more data acquisition channels if needed. Some potential studies that could be carried out using the facility include: 1) An investigation into the efficiency of cooling various segments of the body to lower Tc 1-2 F. 2) A series of heat and mass balance studies comparing various LCG configurations.

Williamson, Rebecca C.↗

Development of the INL Thermal Energy Distribution System (TEDS) in the Modelica Eco-System for Validation and Verification

This report provides an overview on the development of the Thermal Energy Distribution System (TEDS) in the Modelica process model eco-system at Idaho National Laboratory as part of the integrated energy system initiative. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Engineering Science Laboratory (ESL) at INL. The model was then used during the pre-construction phase of the experimental effort to inform experimental design (insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit including: a 200kW Chromalox heater, a single-tank packed bed thermal energy storage system filled with 0.125 inch Alumina (Al 2 O 3 ), an ethylene-glycol to Therminol-66 heat exchanger, system piping, six control valves, and all associated temperature, pressure, and mass flow sensors. The model does not include nitrogen fill gas tanks, or associated overfill tanks, as these are not part of standard system control. Two simulation sets were run. The first is a five-hour test that operates as a shakedown test for the facility. This simulation puts the facility through all five potential operating modes and showcases the ability of valving, control sensors, and component controllers to meet the system demands. The second case imposes a typical summer day demand on the system from a region with mixed commercial and residential electrical needs where the generator alone cannot meet peak demand but instead requires the thermal storage unit to act as a peaking unit. Over the course of the fifteen-hour discharge cycle heat losses account for a heat loss of approximately 15°C in outlet temperature. Such heat losses would lead to a decrease in overall system efficiency and may lead to additional design changes for such designs in the future that may include a topping heater. Through commencement of this work, a systems level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model has been utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Once TEDS begins operation, this model will be refined, tuned, and used for validation and verification purposes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct-Steam Linear Fresnel Performance Model for NREL's System Advisor Model

This paper presents the technical formulation and demonstrated model performance results of a new direct-steam-generation (DSG) model in NREL's System Advisor Model (SAM). The model predicts the annual electricity production of a wide range of system configurations within the DSG Linear Fresnel technology by modeling hourly performance of the plant in detail. The quasi-steady-state formulationallows users to investigate energy and mass flows, operating temperatures, and pressure drops for geometries and solar field configurations of interest. The model includes tools for heat loss calculation using either empirical polynomial heat loss curves as a function of steam temperature, ambient temperature, and wind velocity, or a detailed evacuated tube receiver heat loss model. Thermallosses are evaluated using a computationally efficient nodal approach, where the solar field and headers are discretized into multiple nodes where heat losses, thermal inertia, steam conditions (including pressure, temperature, enthalpy, etc.) are individually evaluated during each time step of the simulation. This paper discusses the mathematical formulation for the solar field model anddescribes how the solar field is integrated with the other subsystem models, including the power cycle and optional auxiliary fossil system. Model results are also presented to demonstrate plant behavior in the various operating modes.

14 SOLAR ENERGY↗

Numerical and Experimental Study of an Aircraft Igniter Plasma Jet Discharge

The spark discharge of an aircraft plasma jet igniter is studied using high-fidelity numerical simulations and X-ray radiography measurements. The target problem here features the thermal expansion of hot gas introduced by the electric spark within a confined igniter cavity, which eventually evolves into a pulsed jet of a high-temperature kernel. A comprehensive set of models adapted from existing strategies for internal combustion engine spark plug discharge is extended to the target problem, including the modeling of energy deposition, plasma reactions, thermodynamic properties, and heat losses. A series of validation and parameter studies are performed and presented. The kernel size is found to be sensitive to heat losses arising from radiation and hot gas remained within the discharge cavity, rather than heat conduction to the wall in the discharge cavity. Depending on the enforced shape of the post-breakdown electric arc, the spark kernel can be off-centered, tilted, and considerably asymmetric. These features have been previously not considered when studying such igniter configurations and may have a first-order impact on the ignition process. Provided a proper setup of the heat loss models and electric arc shape, the numerical results are quantitatively comparable to the experimental results in terms of the kernel size, shape, and velocity throughout different stages after the spark discharge.

Tang, Yihao↗

The role of individual surface flux components in the passive and active ocean heat uptake

Ocean model experiments forced by different combinations of heat, freshwater, and momentum perturbations associated with CO$_2$ increase, are used to isolate the role of individual surface forcing components on the passive and active ocean heat uptake components. The forcings are derived from a fully coupled CO2-quadrupling experiment. The passive uptake is due to the passive absorption of surface heat flux anomalies directly caused by CO2 increase by ocean circulation, while the active or redistributive feedback uptake is the indirectly forced ocean heat uptake caused by ocean circulation change. The passive component is similar among the experiments, therefore, is not sensitive to the circulation anomaly variation among the experiments, but the active component shows large differences. Surface heat flux perturbation causes the passive heat uptake and most of the AMOC weakening, however, it results in a net active heat loss (14% of the passive uptake). This net active heat loss is the residual of the active heat gain, primarily in the North Atlantic and heat loss, largely in the tropical Pacific. Fresh-water perturbation weakens the AMOC a little more, but causes a large active heat gain (40% of the passive uptake), largely in the North Atlantic. Wind perturbation causes about the same amount of active heat loss as heat flux perturbation, due to the poleward shift of the subtropical cells in the Southern Hemisphere. The experiments show that active ocean heat uptake is not simply determined by the degree of AMOC weakening.

Garuba, Oluwayemi A.↗

An optimized model and test of the China's first high temperature parabolic trough solar receiver

The vacuum solar receiver is the key component of a parabolic trough solar plant, which plays a prominent role in the gross system efficiency. Recently, China's first high temperature vacuum receiver, Sanle-3 HCE, has been developed and produced by Southeast University and Sanle Electronic Group. Before being utilized in China's first parabolic trough solar plant, accurately estimating the thermal properties of this new receiver is important. This paper first establishes and optimizes a 1-D theoretical model at Matlab program to compute the receiver's major heat loss through glass envelope, and then systematically analyzes the major influence factors of heat loss. With the laboratorial steady state test stand, the heat losses of both good vacuum and non-vacuum Sanle-3 receivers were surveyed. Comparison shows the original 1-D model agrees with the ends covered test while remarkably deviating from end exposed test. For the purpose of identifying the influence of receiver's end to total heat loss, an additional 3-D model is built by CFD software to further investigate the different heat transfer processes of receiver's end components. The 3-D end model is verified by heating power and IR temperature distribution images in the test. Combining the optimized 1-D model with the new 3-D end model, the comparison with test data shows a good accordance. At the same time the heat loss curve and emittance curve of this new receiver are given and compared with those of several other existing receivers as references. (author)

14 SOLAR ENERGY↗

Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of remote thermal scanning to the NASA energy conservation program

Airborne thermal scans of all NASA centers were made during 1975 and 1976. The remotely sensed data were used to identify a variety of heat losses, including those from building roofs and central heating system distribution lines. Thermal imagery from several NASA centers is presented to demonstrate the capability of detecting these heat losses remotely. Many heat loss areas located by the scan data were verified by ground surveys. At this point, at least for such energy-intensive areas, thermal scanning is an excellent means of detecting many possible energy losses.

Bowman, R. L.↗

Venting Gases With Minimum Loss Of Heat

Design of vent reduces radiative transfer of heat. Venting system allows gases to escape while minimizing loss of heat by radiation. Prevents excessive buildup of internal pressure on thermal blanket. Polyimide box serves as modular vent. Many modules combined to suit gas-flow requirements of equipment. Indirect flow paths, external thermal control film, and thermal blankets reduce radiative loss of heat from interior. Developed to permit outgassing from thermal-blanket-covered spacecraft during passage from atmosphere of Earth to vacuum of space, venting approach adaptable to thermal insulation in laboratory vacuum systems.

Ocoin, James R.↗

Self-Propagating Frontal Polymerization in Water at Ambient Pressure

Advances in polymer chemistry have led to the development of monomers and initiation agents that enable propagating free-radical polymerization fronts to exist. These fronts are driven by the exothermicity of the polymerization reaction and the transport of heat from the polymerized product to the reactant monomer/solvent/initiator solution. The thermal energy transported to the reactant solution causes the initiator to decompose, yielding free radicals, which start the free radical polymerization process as discussed in recent reviews. The use of polymerization processes based on propagating fronts has numerous applications. Perhaps the most important of these is that it enables rapid curing of polymers without external heating since the polymerization process itself provides the high temperatures necessary to initiate and sustain polymerization. This process also enables more uniform curing of arbitrarily thick samples since it does not rely on heat transfer from an external source, which will necessarily cause the temperature history of the sample to vary with distance from the surface according to a diffusion-like process. Frontal polymerization also enables filling and sealing of structures having cavities of arbitrary shape without having to externally heat the structure. Water at atmospheric pressure is most convenient solvent to employ and the most important for practical applications (because of the cost and environmental issues associated with DMSO and other solvents). Nevertheless, to our knowledge, steady, self-propagating polymerization fronts have not been reported in water at atmospheric pressure. Currently, polymerization fronts require a high boiling point solvent (either water at high pressures or an alternative solvent such as dimethyl sulfoxide (DMSO) (boiling point 189 C at atmospheric pressure.) Early work on frontal polymerization, employed pressures up to 5000 atm in order to avoid boiling of the monomer/solvent/initiator solution. High boiling point solutions are needed because in order to produce a propagating front, a high front temperature is needed to produce sufficiently rapid decomposition of the free radical initiator and subsequent free radical polymerization and heat release at a rate faster than heat losses remove thermal energy from the system. (While the conduction heat loss rate increases linearly with temperature, the free radical initiator decomposition is a high activation energy process whose rate increases much more rapidly than linearly with temperature, thus as the temperature decreases, the ratio of heat loss to heat generation increases, eventually leading to extinction of the front if the temperature is too low.) In order to obtain atmospheric pressure frontal polymerization in water, it is necessary to identify a monomer/initiator combination that is water soluble and will not extinguish even when the peak temperature (T*) is less than 100 C. In this work acrylic acid (AA) was chosen as the monomer because is it one of the most reactive monomers and can polymerize readily at low temperatures even without initiators. Ammonium persulfate (AP) was chosen as the initiator because it decomposes readily at low temperatures, produces relatively few bubbles and is commercially available. The propagation rates and extinction conditions of the fronts are studied for a range of AA and AP concentrations. Small amounts of fumed silica powder (Cab-o-sil, Cabot Corporation) were added to the solutions to inhibit buoyancy induced convection in the solutions; future studies will investigate the effects of buoyant convection within the solutions.

Olten, Nesrin↗

Pressure losses and heat transfer in non-circular channels with hydraulically smooth walls

The influence of channel geometry on pressure losses and heat transfer in noncircular channels with hydraulically smooth walls was studied. As a basic assumption for the description of this influence, integral geometrical criteria, selected according to experimental experience, were introduced. Using these geometrical criteria, a large set of experimental data for pressure losses and heat transfer in circular and annular channels with longitudinal fins was evaluated. In this way it as empirically proved that the criteria described channel geometry fairly well.

Malak, J.↗

Thermoregulation During Deconditioning

The importance of maintaining body temperature is well understood by both clinicians and lay persons. The normal, resting body core temperature is about 37 C (98.6 F), and death often occurs when it falls below 27 C (80.6 F) or exceeds 42 C (107.6 F). Thus, for survival the degree of overheating is more critical than that for overcooling. The lower limit of body core temperature for onset of heatstroke is usually only 41 C - 42 C (105.8 F - 107.6 F), but classic heatstroke has occurred with core body temperature as low as 40.6 (105.1 F). The physical effects of weightlessness on heat loss responses have not been well investigated; however, convective heat loss is greatly compromised and evaporative heat loss may also be impaired. These effects on convection and evaporation can be minimized by increasing air flow and reducing ambient humidity. The specific environments that crew members may be expected to encounter are described in this chapter.

Schneider, Suzanne M.↗

Exercise Thermoregulation in Men after One and 24-hours of 6 Degree Head-Down Tilt

Exercise thermoregulation exercise is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise.

Ertl, A. C.↗

Exercise thermoregulation in men after 1 and 24-hours of 6 degrees head-down tilt

BACKGROUND: Exercise thermoregulation is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise. HYPOTHESIS: We hypothesized that 24 h of head down tilt (HDT24) would alter thermoregulatory responses to a submaximal exercise test and result in a higher exercise rectal temperature (Tre) when compared with exercise Tre after 1 h of head down tilt (HDT1). METHODS: Seven men (31+/-SD 6 yr, peak oxygen uptake (VpO2peak) of 44+/-6 ml x kg(-1) x min(-1)) were studied during 70 min of supine cycling at 58+/-SE 1.5% VO2peak at 22.0 degrees C Tdb and 47% rh. RESULTS: Relative to pre-tilt sitting chair rest data, HDT1 resulted in a 6.1+/-0.9% increase and HDT24 in a 4.3+/-2.3% decrease in PV (delta = 10.4% between experiments, p<0.05) while plasma osmolality remained unchanged (NS). Pre-exercise Tre was elevated after HDT24 (36.71 degrees C +/-0.06 HDT1 vs. 36.93 degrees C+/-0.11 HDT24, p<0.05). The 70 min of exercise did not alter this relationship (p<0.05) with respective end exercise increases in Tre to 38.01 degrees C and 38.26 degrees C (degrees = 1.30 degrees C (HDT1) and 1.33 degrees C (HDT24)). While there were no pre-exercise differences in mean skin temperature (Tsk), a significant (p<0.05) time x treatment interaction occurred during exercise: after min 30 in HDT24 the Tsk leveled off at 31.1 degrees C, while it continued to increase reaching 31.5 degrees C at min 70 in HDT1. A similar response (NS) occurred in skin blood velocity. Neither local sweating rates nor changes in body weight during exercise of -1.63+/-0.24 kg (HDT1) or - 1.33+/-0.09 kg (HDT24) were different (NS) between experiments. CONCLUSION: While HDT24 resulted in elevated pre-exercise Tre, reduced PV, attenuation of Tsk and skin blood velocity during exercise, the absolute increase in exercise Tre was not altered. But if sweat rate and cutaneous vascular responses were similar at different core temperatures (unchanged thermoregulation), the Tre offset could have been caused by the HDT-induced hypovolemia.

NASA Program Biomedical Research and Countermeasur↗

Remote Measurement of Heat Flux from Power Plant Cooling Lakes

Laboratory experiments have demonstrated a correlation between the rate of heat loss q" from an experimental fluid to the air above and the standard deviation σ of the thermal variability in images of the fluid surface. These experimental results imply that q" can be derived directly from thermal imagery by computing σ. This paper analyses thermal imagery collected over two power plant cooling lakes to determine if the same relationship exists. Turbulent boundary layer theory predicts a linear relationship between q" and σ when both forced (wind driven) and free (buoyancy driven) convection are present. Datasets derived from ground- and helicopter-based imagery collections had correlation coefficients between σ and q" of 0.45 and 0.76, respectively. Values of q" computed from a function of σ and friction velocity u* derived from turbulent boundary layer theory had higher correlations with measured values of q" (0.84 and 0.89). Finally, this research may be applicable to the problem of calculating losses of heat from the ocean to the atmosphere during high-latitude cold-air outbreaks because it does not require the information typically needed to compute sensible, evaporative, and thermal radiation energy losses to the atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Interpretation of Ground Temperature Anomalies in Hydrothermal Discharge Areas

Abstract Researchers have long noted the potential for shallow hydrothermal fluids to perturb near‐surface temperatures. Several investigators have made qualitative or semiquantitative use of elevated surface temperatures; for example, in snowfall calorimetry, or for tracing subsurface flow paths. However, a quantitative framework connecting surface temperature observations with conditions in the subsurface is currently lacking. Here, we model an area of shallow subsurface flow at Burgdorf Hot Springs, a rustic commercial resort in the Payette National Forest, north of McCall, ID, USA. We calibrate the model using shallow (0.2 m depth) ground temperature measurements and overburden thickness estimates from seismic refraction studies. The calibrated model predicts negligible loss of heat energy from the laterally migrating fluids at the Burgdorf site, in spite of the fact that thermal anomalies are observed in the unconsolidated near‐surface alluvium. Although elevated near‐surface ground temperatures are commonly assumed to result from locally high heat flux, this conflicts with the small apparent heat loss during lateral flow inferred at the Burgdorf site. We hypothesize an alternative explanation for near‐surface temperature anomalies that is only weakly dependent on heat flux, and more strongly controlled by the Biot number, a dimensionless parameter that compares the rate at which convection carries heat away from the land surface to the rate at which it is supplied by conduction to the interface.

Price, Adam N.↗

Chemical Reactor Network Modeling of Ammonia Rich-Quench-Lean Combustion Using a Partially Stirred Reactor Approach

Ammonia is a promising alternative to hydrogen with high energy density and favorable storage and transport characteristics. However, low flammability and a propensity for high nitrogen oxide (NO x ) emissions make direct utilization challenging. Recently, two-stage rich-quench-lean (RQL) combustion strategies have shown promise in achieving low NO x emissions with ammonia. In this approach, the rich stage serves to oxidize a portion of the fuel while thermally decomposing as much of the remaining ammonia as possible, generating hydrogen. In the second (lean) stage, air is rapidly introduced, burning out the hydrogen and residual ammonia. Two-stage RQL combustion of ammonia has been investigated in the open literature both experimentally and numerically. In general, idealized chemical reactor network (CRN) models predict NO x concentrations below those of 2D/3D computational fluid dynamics models and experiments. The primary drivers of these discrepancies may be largely attributed to finite rate mixing nonadiabatic operation. The typical CRN model is comprised of a perfectly-stirred-reactor (PSR), followed by a plug-flow-reactor (PFR), meant to represent the flame, and postflame zones, respectively. In the two-stage RQL approach two PSR-PFR networks are arranged sequentially, corresponding to the rich and lean stages, with secondary air injection in between. In the authors' past work, this arrangement has demonstrated the significant sensitivity of exit NO x to the rich stage equivalence ratio, while the amount of secondary air injection was shown to be less critical. In this paper, the CRN model is extended to (1) include the impacts of heat loss and (2) utilize a partially-stirred-reactor (PaSR) approach to study the impacts of mixing on emissions performance. Varying amounts of heat loss are applied to the rich relaxation zone to understand emissions performance and changes to optimization of equivalence ratio and residence time. Premixed and nonpremixed configurations are considered in the rich stage PaSR, with varying degrees of mixing intensity to study the interaction between mixing, transport, and kinetic timescales. Critically, the impact of mixing between hot products and secondary air injection is studied to understand practical injector needs. Results show unburnt ammonia leaving the rich stage as a primary contributor to NO x emissions – driven both by increased heat loss and reduced mixing rates. Furthermore, heat losses have been shown to create conditions that are conducive to increased N 2 O formation in the lean stage. In conclusion, the results of this study will be considered in the context of developing optimized two-stage RQL combustors for ammonia.

Combustion↗