Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “H- source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Negative ions from alkali hydrides as a source for H(-) beams

The production of H(-) ions by heating LiH powder in a high-temperature crucible was investigated experimentally and theoretically. It is found that the efficiency of H(-) ion production by this method is high. However, the theory for the negative surface ionization indicates that such high efficiency is not possible at crucible temperatures of about 750 C. The need for a further study of LiH ionization is emphasized.

Srivastava, S. K.↗

Linac4 H{sup −} ion sources

CERN’s 160 MeV H{sup −} linear accelerator (Linac4) is a key constituent of the injector chain upgrade of the Large Hadron Collider that is being installed and commissioned. A cesiated surface ion source prototype is being tested and has delivered a beam intensity of 45 mA within an emittance of 0.3 π ⋅ mm ⋅ mrad. The optimum ratio of the co-extracted electron- to ion-current is below 1 and the best production efficiency, defined as the ratio of the beam current to the 2 MHz RF-power transmitted to the plasma, reached 1.1 mA/kW. The H{sup −} source prototype and the first tests of the new ion source optics, electron-dump, and front end developed to minimize the beam emittance are presented. A temperature regulated magnetron H{sup −} source developed by the Brookhaven National Laboratory was built at CERN. The first tests of the magnetron operated at 0.8 Hz repetition rate are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical modeling of the SNS H{sup −} ion source

Ion source rf antennas that produce H- ions can fail when plasma heating causes ablation of the insulating coating due to small structural defects such as cracks. Reducing antenna failures that reduce the operating capabilities of the Spallation Neutron Source (SNS) accelerator is one of the top priorities of the SNS H- Source Program at ORNL. Numerical modeling of ion sources can provide techniques for optimizing design in order to reduce antenna failures. There are a number of difficulties in developing accurate models of rf inductive plasmas. First, a large range of spatial and temporal scales must be resolved in order to accurately capture the physics of plasma motion, including the Debye length, rf frequencies on the order of tens of MHz, simulation time scales of many hundreds of rf periods, large device sizes on tens of cm, and ion motions that are thousands of times slower than electrons. This results in large simulation domains with many computational cells for solving plasma and electromagnetic equations, short time steps, and long-duration simulations. In order to reduce the computational requirements, one can develop implicit models for both fields and particle motions (e.g. divergence-preserving ADI methods), various electrostatic models, or magnetohydrodynamic models. We have performed simulations using all three of these methods and have found that fluid models have the greatest potential for giving accurate solutions while still being fast enough to perform long timescale simulations in a reasonable amount of time. We have implemented a number of fluid models with electromagnetics using the simulation tool USim and applied them to modeling the SNS H- ion source. We found that a reduced, single-fluid MHD model with an imposed magnetic field due to the rf antenna current and the confining multi-cusp field generated increased bulk plasma velocities of > 200 m/s in the region of the antenna where ablation is often observed in the SNS source. We report here on comparisons of simulated plasma parameters and code performance using more accurate physical models, such as two-temperature extended MHD models, for both a related benchmark system describing a inductively coupled plasma reactor, and for the SNS ion source. We also present results from scaling studies for mesh generation and solvers in the USim simulation code.

07 ISOTOPE AND RADIATION SOURCES↗

Dinitrogen Binding and Functionalization

This chapter presents fundamental aspects of the coordination chemistry of N 2 , including structure, spectroscopy, reactivity, and catalysis. We start by comparing and contrasting the binding of N 2 with the isoelectronic CO ligand that is familiar to organometallic chemists, and show that though they are isolobal, there are significant differences. We also describe the numerous practical considerations to bear in mind when preparing, studying, and interpreting the properties and reactions of N 2 complexes, and include pitfalls from the perspective of practitioners. The different binding modes and reactions of N 2 complexes are tabulated, giving representative examples of various complexes and reactions. Formation of new bonds between N 2 and H sources such as protons and H 2 , as well as multiatomic groups containing Si, C, and B, give insight into the status of the field and opportunities for the future.

ammonia↗

The effect of the H{sub 2} density on the electron energy distribution in H{sup −} ion sources

The electron energy distribution in H{sup −} ion sources is studied. By three-dimensional Monte Carlo simulations (3D-MCC) and cross sections of collisions, the crucial collisions in the JAEA 10A are chosen to develop theoretical models for the low electron temperature and the high electron temperature, respectively. The effects of the H{sub 2} density on the low electron temperature and the high electron temperature in H{sup −} ion sources are predicted with analytic expressions and verified by 3D-MCC. The results show that both the low and high electron temperatures become lower while n{sub H2} increases.

43 PARTICLE ACCELERATORS↗

Dependence of beam emittance on plasma electrode temperature and rf-power, and filter-field tuning with center-gapped rod-filter magnets in J-PARC rf-driven H{sup −} ion source

The prototype rf-driven H{sup −} ion-source with a nickel plated oxygen-free-copper (OFC) plasma chamber, which satisfies the Japan Proton Accelerator Research Complex (J-PARC) 2nd stage requirements of a H{sup −} ion beam current of 60 mA within normalized emittances of 1.5 π mm mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500 μs × 25 Hz) and a life-time of more than 50 days, was reported at the 3rd international symposium on negative ions, beams, and sources (NIBS2012). The experimental results of the J-PARC ion source with a plasma chamber made of stainless-steel, instead of nickel plated OFC used in the prototype source, are presented in this paper. By comparing these two sources, the following two important results were acquired. One was that the about 20% lower emittance was produced by the rather low plasma electrode (PE) temperature (T{sub PE}) of about 120 °C compared with the typically used T{sub PE} of about 200 °C to maximize the beam current for the plasma with the abundant cesium (Cs). The other was that by using the rod-filter magnets with a gap at each center and tuning the gap-lengths, the filter-field was optimized and the rf-power necessary to produce the J-PARC required H{sup −} ion beam current was reduced typically 18%. The lower rf-power also decreases the emittances.

43 PARTICLE ACCELERATORS↗

Progress in the development of an H{sup −} ion source for cyclotrons

A multi-cusp DC H{sup −} ion source has been developed for cyclotrons in medical use. Beam optics of the H{sup −} ion beam is studied using a 2D beam trajectory code. The simulation results are compared with the experimental results obtained in the Mark I source, which has produced up to 16 mA H{sup −} ion beams. The optimum extraction voltages show good agreement between the calculation and the experimental results. A new ion source, Mark II source, is designed to achieve the next goal of producing an H{sup −} beam of 20 mA. The magnetic field configurations and the plasma electrode design are optimized for Cs-seeded operation. Primary electron trajectory simulation shows that primary electrons are confined well and the magnetic filter prevents the primary electrons from entering into the extraction region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The FNAL injector upgrade

The present FNAL H{sup -} injector has been operational since the 1970s and consists of two magnetron H{sup -} sources and two 750 keV Cockcroft-Walton Accelerators. In the upgrade, both slit-type magnetron sources will be replaced with circular aperture sources, and the Cockcroft-Waltons with a 200 MHz RFQ (radio frequency quadrupole). Operational experience at BNL (Brookhaven National Laboratory) has shown that the upgraded source and RFQ will be more reliable, improve beam quality and require less manpower than the present system. The present FNAL (Fermi National Accelerator Laboratory) injector has been operational since 1978 and has been a reliable source of H{sup -} beams for the Fermilab program. At present there are two Cockcroft-Walton injectors, each with a magnetron H{sup -} source with a slit aperture. With these two sources in operation, the injector has a reliability of better than 97%. However, issues with maintenance, equipment obsolescence, increased beam quality demands and retirement of critical personnel, have made it more difficult for the continued reliable running of the H{sup -} injector. The recent past has also seen an increase in both downtime and source output issues. With these problems coming to the forefront, a new 750 keV injector is being built to replace the present system. The new system will be similar to the one at BNL (Brookhaven National Laboratory) that has a similar magnetron source with a round aperture and a 200MHz RFQ. This combination has been shown to operate extremely reliably.

43 PARTICLE ACCELERATORS↗

Power efficiency improvements with the radio frequency H{sup −} ion source

CW 13.56 MHz radio frequency-driven H{sup −} ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H{sup −} beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation of the main plasma from the plasma electrode. While the original system provided better control over the e{sup −}/H{sup −} ratio, the new configuration has led to a higher production efficiency of 1 mA H{sup −} at 1.75 kW RF power. The latest results and upgrade plans are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗