Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid disturbance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Communication-Constrained Expansion Planning for Resilient Distribution Systems

Distributed generation and remotely controlled switches have emerged as important technologies to improve the resiliency of distribution grids against extreme weather-related disturbances. Therefore it becomes important to study how best to place them on the grid in order to meet a resiliency criteria, while minimizing costs and capturing their dependencies on the associated communication systems that sustain their distributed operations. This paper introduces the Optimal Resilient Design Problem for Distribution and Communication Systems (ORDPDC) to address this need. The ORDPDC is formulated as a two-stage stochastic mixed-integer program that captures the physical laws of distribution systems, the communication connectivity of the smart grid components, and a set of scenarios that specifies which components are affected by potential disasters. The paper proposes an exact branch-and-price algorithm for the ORDPDC that features a strong lower bound and a variety of acceleration schemes to address degeneracy. The ORDPDC model and branch-and-price algorithm were evaluated on a variety of test cases with varying disaster intensities and network topologies. The results demonstrate the significant impact of the network topologies on the expansion plans and costs, as well as the computational benefits of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

Enhancing the Survivability of Power Systems With Grid-Edge DERs Against DoS Attacks

Power system survivability, defined as the ability of a system to maintain steady-state functionality under varying operational conditions, reflects its resilience against disturbances. While existing research primarily focuses on physical-layer disturbances, the increasing prevalence of grid-edge DERs, which are primarily used for integrating renewable energy, has significantly expanded the cyber attack surface. As a result, operational disruptions caused by cyber threats are posing significant challenges to system survivability and cannot be overlooked. To fill this gap, we redefine system survivability to incorporate the cyber layer’s status and propose a Distributionally Robust Optimization (DRO) approach to enhance power system survivability against potential cyber-physical threats. In this paper, we first analyze the operational guidelines of systems with a high penetration of DERs under various cyber network conditions and redefine survivability in this context. Next, we focus on the most common cyber threat, Denial-of-Service (DoS) attacks, and develop a corresponding attack model. This model allows for the creation of a kernel-based ambiguity set that captures attack uncertainties using historical data. Finally, we transform the proposed DRO model as a tractable optimization problem, with its solution providing an optimal cyber redundancy plan to enhance system survivability in DoS attack scenarios. Simulation results on the IEEE 13-node and 123-node test feeders demonstrate the effectiveness of our proposed model in improving system survivability. This model can also be expanded to include other types of common attacks and serve as a comprehensive planning tool to improve overall cyber physical survival of the system.

cybersecurity↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operationalizing Synchrophasors for Enhanced Grid Reliability and Asset Utilization

The report discusses the development of production-grade synchrophasor software applications. The objective is to improve system reliability and asset utilization for offline as well as real-time considerations, as per the Department of Energy (DOE) guidelines specified by Funding Opportunity Announcement (FOA) DE-FOA-0001492. On the one hand, we have developed grid management applications on how to transform synchrophasor-based monitoring into operator guidance, and commercial grade tools addressing industry needs such as NERC Reliability Standards (MOD 26, MOD 27 and MOD 33). On the other hand, with the wide industrial adoption in mind, the developed applications have been fully discussed with utility partners and installed in the utility partners site including 6 field tests. The Model Validation and Calibration software module has been integrated into GE’s PhasorAnalyticsTM. The first commercial contract has been signed even before the close date of this project. The Angle-based Grid Management (AGM), Fast Voltage Security Assessment (FastVSA), Enhanced Islanding Monitoring(EIM) and Enhanced Disturbance Management (EDM) have been integrated into GE’s Grid Stability Assessment line of applications in e-terra Suite of EMS product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators: Preprint

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

DeepONet-grid-UQ: A trustworthy deep operator framework for predicting the power grid’s post-fault trajectories

This paper proposes a novel data-driven method for the reliable prediction of the power grid’s post-fault trajectories, i.e., the power grid’s dynamic response after a disturbance or fault. Here, the proposed method is based on the recently proposed concept of Deep Operator Networks (DeepONets). Unlike traditional neural networks that learn to approximate functions, DeepONets are designed to approximate nonlinear operators, i.e., mappings between infinite-dimensional spaces. Under this operator framework, we design a novel and efficient DeepONet that (i) takes as inputs the trajectories collected before and during the fault and (ii) outputs the predicted post-fault trajectories. In addition, we endow our method with the much-needed ability to balance efficiency with reliable/trustworthy predictions via uncertainty quantification. To this end, we propose and compare two novel methods that enable quantifying the predictive uncertainty. First, we propose a Bayesian DeepONet (B-DeepONet) that uses stochastic gradient Hamiltonian Monte-Carlo to sample from the posterior distribution of the DeepONet trainable parameters. Then, we design a Probabilistic DeepONet (Prob-DeepONet) that uses a probabilistic training strategy to enable quantifying uncertainty at virtually no extra computational cost. Finally, we validate the proposed methods’ predictive power and uncertainty quantification capability using the New York-New England power grid model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Step Towards Machine Learning-based Coherent Generator Grouping for Emergency Control Applications in Modern Power Grid

A dynamic neural network (NN) based multi-class classifier is proposed for improving online prediction of coherent generator groups (CGGs), following the occurrences of various contingencies in the power grid. This is motivated by the increasing availability of the measurements from phasor measurement units (PMUs) and the number of grouping schemes is limited. The proposed method consists of three steps. First, by performing offline simulations, a library of system dynamic responses characterized by post-contingency rotor angles and speeds of individual generators is obtained. To generate sufficient data, up to N-2 contingencies and the uncertain parameters associated with the power grid including type and location of disturbance and fault clearing times are modeled. Secondly, the training data-set is produced by generating labels for individual contingencies using a hierarchical clustering method based on rotor angle and speed data. Lastly, the dynamic NN models are trained for online applications such as emergency controls and controlled islanding. The proposed method is tested on the standard 16-generator 68-bus system to demonstrate its performance. Furthermore, the impact of the sample data lengths on the CGG numbers is evaluated. It is interesting to observe that the time domain stability behaviors can be determined by examining the changes in the CGG numbers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Frequency Response and Congestion Management using Multi-Terminal HVDC Overlay

Continental level power system interconnections using a High Voltage direct current (HVDC) transmission lines have been considered to bring economic benefits such as interregional power exchange. This paper describes the modeling process and studies the technical benefits of having multiple HVDC lines, including a grid of HVDC lines (macrogrid) configuration, connecting the North American Eastern and Western electric power interconnections. The models developed provide steady state and stability analysis for multiple HVDC overlay topologies and provide technical benefit analysis in terms of frequency response and congestions management. The paper also provides a comparison of different HVDC topologies performance and their grid support in case of major disturbances

Tbaileh, Ahmad↗

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Single-Stage Multilevel AC-DC Bidirectional Converter With Natural Grid Harmonic Elimination

Generally, AC-DC converters have an AC-DC stage followed by a DC-DC stage. In these two stage approaches, the AC-DC stage is hard-switched, whereas the DC-DC stage is soft-switched. Therefore, the devices in the AC-DC stage can be switched only at tens of kHz to avoid excessive switching losses, thus limiting the bandwidth of the current control loop. Hence, the control of these converters with distorted grid voltages requires multiple harmonic compensation loops or other complex control algorithms in order for the grid currents to comply with IEEE standards. By integrating both the stages, the devices in the AC-DC stage can also be soft-switched, thus facilitating higher switching frequency, and thereby higher current control bandwidth. This paper proposes an integrated multilevel bidirectional AC-DC converter with improved control bandwidth and disturbance rejection. It is shown experimentally that the high bandwidth current control loop of the converter can reject grid harmonic current disturbances, without the need for any compensation loops or complex control techniques, and comply with IEEE standards.

30 DIRECT ENERGY CONVERSION↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Integrated Assessment of a G3 GMD Event on Large-Scale Power Grids: From Magnetometer Data to Geomagnetically Induced Current Analysis

Solar activities can cause geomagnetic disturbances (GMDs) that give rise to geomagnetically induced currents (GICs) which may compromise the reliability of the power system. In order to build more reliable models representing GMD interactions with the power grid, the power system’s detailed electrical model must be considered along with fluctuations in the earth’s magnetic and induced surface electric fields. Here, this study investigates the impact of incorporating spatially varying magnetic fields into surface electric field models on GMD risk metrics. A spatially independent magnetic field model and a spatially varying model are compared through simulations. To perform this analysis, the earth’s magnetic field disturbances are transformed into surface electric fields using respective one-dimensional earth conductivity models. Then, the modeling impact of these electric fields is studied using a 2,000-bus grid for Texas and a 25,000-bus grid for the northeast and mid- Atlantic regions of the United States. Simulation results reveal that the inclusion of spatially varying magnetic fields results in considerable differences in GMD risk metrics, highlighting the importance of accounting for spatial variability when assessing GMD risks in the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Distributional Deep Reinforcement Learning-Based Emergency Frequency Control

Emergency frequency control is one of the most critical approaches to maintain power system stability after major disturbances. With the increasing number of grid-connected renewable energy sources, existing model-based methods of frequency control are facing up with challenges of computational speed and scalability for large-scale systems. In this paper, the emergency frequency control problem is formulated as a Markov Decision Process (MDP) and solved through a novel Distributional Deep Reinforcement Learning (DDRL) method, namely the distributional soft actor critic (DSAC) method. Compared with other RL methods that only estimate the mean value, the proposed DSAC model estimates the distribution of value function over returns. This advancement can lead to more insights and knowledge for the agent, with the benefit of a much faster and more stable learning process, and the improved frequency control performance. Here, the simulation results on IEEE 39-bus and IEEE 118-bus systems demonstrate the effectiveness and robustness of proposed models, as well as the advantage compared to other state-of-the-art DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗