Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gasket”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Elastic properties of the W 0.75 R e 0.25 alloy at high pressure up to 183 GPa

The high pressure equation of state for the W 0.75 R e 0.25 alloy is experimentally determined up to 183 GPa with synchrotron angle-dispersive powder x-ray diffraction in the diamond-anvil cell and to ∼925 GPa with density-functional theory. W-Re alloys are used in many industrial high-temperature applications and as a confining gasket material in high-pressure diamond-anvil cell research. The inclusion of 25 wt. % Re achieves the highest performance in terms of strength and ductility while also maintaining the body-centered-cubic (bcc) crystal structure, yet to date there has been no investigation into its elastic behavior at high pressure. We present the experimentally and theoretically determined volumetric and elastic pressure response and systematically compare these results to other W-Re alloys, finding that the bulk modulus of W-Re alloys varies nonlinearly with Re content and W 0.75 Re 0.25 becomes less incompressible than W at 85 GPa. Published by the American Physical Society 2025

Alloys↗

Montel mirror based collimating analyzer system for high-pressure resonant inelastic X-ray scattering experiments

Resonant inelastic X-ray scattering (RIXS) is increasingly playing a significant role in studying highly correlated systems, especially since it was proven capable of measuring low-energy magnetic excitations. However, despite high expectations for experimental evidence of novel magnetic phases at high pressure, unequivocal low-energy spectral signatures remain obscured by extrinsic scattering from material surrounding the sample in a diamond anvil cell (DAC): pressure media, Be gasket and the diamond anvils themselves. A scattered X-ray collimation based medium-energy resolution (~100 meV) analyzer system for a RIXS spectrometer at the Ir L 3 -absorption edge has been designed and built to remediate these difficulties. Due to the confocal nature of the analyzer system, the majority of extrinsic scattering is rejected, yielding a clean low-energy excitation spectrum of an iridate Sr 2 IrO 4 sample in a DAC cell. Finally, the energy resolution of different configurations of the collimating and analyzing optics are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

STUDIES ON PIPELINE POLYETHYLENES IN HYDROGEN GAS ENVIRONMENTS USING IN-SITU AND EX-SITU CHARACTERIZATION METHODS

Polymeric materials are commonplace in the natural gas infrastructure as distribution pipes, coatings, seals, and gaskets. Under the auspices of the U.S. Department of Energy HyBlend program, one of the means to reduce greenhouse gas emissions is with replacing natural gas, either partially or completely, with hydrogen. This approach makes it imperative that we conduct near-term and long-term materials compatibility research in these relevant environments. Insights into the effects of hydrogen and hydrogen gas blends on polymer integrity can be gained through both ex-situ and in-situ analytical methods. Our work represented here highlights a study of the behavior of pipeline polyethylene (PE) materials, including HDPE (Dow 2490 and GDB50) and MDPE (Ineos and legacy Dupont Aldyl A), when exposed to hydrogen by means of in-situ X-ray scattering and ex-situ Raman spectroscopy techniques. Samples were tested in ex-situ hydrogen and argon gas environments and in-situ hydrogen environments to identify differences due to permeation and solubility of these gases. These methods complemented each other because Raman spectroscopy could capture permanent effects after materials were removed from gaseous environments, and in-situ X-ray scattering analysis collected real-time data to elucidate the impact of the gas environment on polymer microstructure. Data collected revealed that the aforementioned polymers did not show significant changes in crystallinity and microstructure under the exposure conditions tested. Our findings from these studies will help establish real-time effects caused by hydrogen gas transport through pipeline polyethylenes by way of its influence on polymer structure and chemistry, which is directly related to pipeline mechanical strength and longevity of service.

Hydrogen materials compatibility, Natural gas pipe↗

Ice-slurry production for solar-ice systems using supercooling with an in-stream crystallizer

Using ice slurry produced from supercooled water with an in-stream crystallizer opens a new path for solarice systems, increasing efficiency and reducing investment cost compared to ice-on-coil systems. Power needs are decoupled from the stored energy since the heat exchangers are not evenly distributed in the ice storage vessel but directly placed as the heat pump evaporator, which depends on the heat pump capacity and not on the ice storage volume. The novel ice storage design can serve as a heat source for a heat pump, where its evaporator is used to supercool water below 0 °C, or for refrigeration. The supercooled water at a temperature around −2 °C, maintained in a meta-stable liquid state, is triggered to nucleate in an in-stream crystallizer. The current design of the ice crystallizer allows for continuous operation of the system and scalability. Experimental results obtained with a gasketed plate heat exchanger used to supercool water and an in-stream crystallizer operated at a power of up to 6.5 kW are presented.

Thamm, Ann-Katrin↗

Evaluation of an Additively Manufactured Respirator for Personnel Protection from Particulates

Additively manufactured respirators (AMRs) made using rigid plastic can be fitted with repurposed filter media to yield a wearable mask capable of passing a quantitative fit test with criteria set for commercial, N95 health care particulate respirators. This has been verified through an evaluation study assessing AMR masks fabricated using open-source design files and a commercial fused-filament fabrication machine, using N95 filter cloth and a P100 respirator cartridge. A few examples of filter media not designed for human respiratory protection were also evaluated in an AMR mask but did not demonstrate filtering sufficient to pass the N95 test criteria. All attributes of an AMR mask system must be considered during design and when testing performance, including the mask frame, gasket, and the cord used to secure the mask to the face. AMR masks are not the same as commercially available respiratory masks. If AMR masks are used as personal protective equipment (PPE) during a crisis when there is a shortage of regular PPE it is important that wearers are fully informed of the differences, tradeoffs, and risks associated with their use. Quantitative fit testing and proper training on how to don and doff the AMR mask are important to help achieve the best possible outcome when they are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Narrow Slot Algorithm

We summarize the narrow slot algorithms, including the thick electrically small depth case, conductive gaskets, the deep general depth case, multiple fasteners along the length, and finally varying slot width.

97 MATHEMATICS AND COMPUTING↗

Collective Summary of sCO2 Materials Development (Supercritical Transformational Electric Power Generation (STEP) Level 2 Milestone Report) (Parts I - II)

Polymers such as PTFE (polytetrafluorethylene or Teflon), EPDM (ethylene propylene diene monomer) rubber, FKM fluoroelastomer (Viton), Nylon 11, Nitrile butadiene (NBR) rubber, hydrogenated nitrile rubber (HNBR) and perfluoroelastomers (FF_202) are commonly employed in super critical CO 2 (sCO2) energy conversion systems. O-rings and gaskets made from these polymers face stringent performance conditions such as elevated temperatures, high pressures, pollutants, and corrosive humid environments. In FY 2019, we conducted experiments at high temperatures (100°C and 120°C) under isobaric conditions (20 MPa). Findings showed that elevated temperatures accelerated degradation of polymers in sCO2, and that certain polymer microstructures are more susceptible to degradation over others. In FY 2020, the focus was to understand the effect of sCO2 on polymers at low (10 MPa) and high pressures (40 MPa) under isothermal conditions (100°C). It was clear that the same selectivity was observed in these experiments wherein certain polymeric functionalities showed more propensity to failure over others. Fast diffusion, supported by higher pressures and long exposure times (1000 hours) at the test temperature, caused increased damage in sCO2 environments to even the most robust polymers. We also looked at polymers under compression in sCO2 at 100°C and 20 MPa pressure to imitate actual sealing performance required of these materials in sCO2 systems. Compression worsened the physical damage that resulted from chemical attack of the polymers under these test conditions. In FY 2021, the effect of cycling temperature (from 50°C to 150°C to 50°C) for polymers under a steady sCO2 pressure of 20 MPa was studied. The aim was to understand the influence of cycling temperatures of sCO2 for typical polymers under isobaric (20 MPa) conditions. Thermoplastic polymers (Nylon, and PTFE) and elastomers (EPDM, Viton, Buna N, Neoprene, FF202, and HNBR) were subjected to 20 MPa sCO2 pressure for 50 cycles and 100 cycles in separate experiments. Samples were extracted for ex-situ characterization at 50 cycles and upon the completion of 100 cycles. Each cycle constituted of 175 minutes of cycling from 50°C to 150°C. The polymer samples were examined for physical and chemical changes by Dynamic Mechanical and Thermal Analysis (DMTA), Fourier Transform Infrared (FTIR) spectroscopy, and compression set. Density and mass changes immediately after removal from test were measured for degree of swell comparisons. Optical microscopy techniques and micro computer tomography (micro CT) images were collected on select specimens. Evaluations conducted showed that exposures to super-critical CO2 environments resulted in combinations of physical and/or chemical changes. For each polymer, the dominance of cycling temperatures under sCO2 pressures, were evaluated. Attempts were made to qualitatively link the permanent sCO2 effects to polymer micro- structure, free volume, backbone substitutions, presence of polar groups, and degree of crystallinity differences. This study has established that soft polymeric materials are conducive to failure in sCO2 through mechanisms of failure that are dependent on polymer microstructure and chemistry. Polar pendant groups, large atom substitutions on the backbone are some of the factors that are influential structural factors.

36 MATERIALS SCIENCE↗

Water-Resistant Container Testing: A846-500 Container Design

The purpose of this report is to detail the results of water ingress testing conducted on the A846-500 container design and discuss these results against the water-resistant container requirements of TA55-AP-522 and PA-RD-01009. The A846-500 is a proposed commercially off the shelf inner container option for material storage inside of a glovebox and/or as an approved non-hermetically sealed inner of an approved packaging configuration inside of an approved outer container as listed in PA-RD-01022. The A845-500 is shaped similar to a soda bottle (wide cylindrical base with a narrow, tapered neck at the top), made of 316L stainless steel, and utilizes a knurled, threaded lid with a silicone gasket for closure and containment.

42 ENGINEERING↗

Progress Report of Alloy 709 Performance in Liquid Sodium

With improved high-temperature properties, Alloy 709 shows great potential for advanced reactor applications. To understand the effects of sodium on A709, small tensile specimens were machined from two commercial heats and subject to sodium exposure in two forced convection loops operated by Argonne. Thermal aging experiments were also conducted in parallel to isolate any sodium-specific effects. An increasing trend in yield strength and a decrease trend in ultimate tensile strength can be seen with the increasing exposure time, suggesting microstructural changes at these temperatures. Nonetheless, the thermally aged and sodium exposed samples behaved similarly, implying no sodium-specific effect at these temperatures. In contrast, 316H SS exposed to sodium at 650°C showed a strong sodium effect. The different responses of A709 and 316H SS to sodium exposure is of interest and requires additional effort to understand. The cold traps of the sodium loop were replaced early in FY23. During a maintenance operation, an unexpected sodium leak incident occurred at one of the sodium loops, triggering an emergency response. An investigation into the incident revealed that the leak happened at a VCR fitting on the recently replaced cold trap. The metal gasket of the leaked VCR fitting was not compressed sufficiently. A dimensional mismatch between the new component and old piping configuration was responsible for a significant misalignment. A new cold trap with improved design is in production. The new design provides additional flexibility and an access point for post-installation helium leak check and for venting of trapped gas. These design features will make the system more error-tolerant and the installation quality verifiable. A thermodynamic analysis was performed to understand the carburization-decarburization behavior of A709 in sodium environment. The equilibrium carbon activity in the alloy was evaluated with M 23 C 6 , TiC, and NbC. The carburization-decarburization boundary was calculated with different methods developed previously. The results suggests that A709 will be carburized in SMT-1 and SMT-2, and can be decarburized in low-carbon-activity environments such as EBR-II at temperatures above 620-650°C. Nonetheless, A709 should be less likely to be decarburized than 316H SS when exposed to the same low-carbon-activity environment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Water-Resistant Container Testing: 48 oz Bruntmor Container Design

The purpose of this report is to detail the results of water ingress testing conducted on the 48 oz Bruntmor container design and discuss these results against the water-resistant container requirements of TA55-AP 522 and PA-RD-01009. The 48 oz Bruntmor is a proposed commercially off the shelf inner container option for material storage inside of a glovebox and/or as an approved non-hermetically sealed inner of an approved packaging configuration inside of an approved outer container as listed in PA-RD-01022. The 48 oz Bruntmor is shaped like a slip lid container, made of 18-8 stainless steel, and utilizes a smooth, threaded lid with a silicone gasket for closure and containment. This container both lid and body is hot rolled out of 18-8 stainless steel with one seam weld on the body.

42 ENGINEERING↗

IER-479/547: Low-Temperature TEX Surrogate Testing and Reflector Design [Slides]

This lecture includes a look into progress in surrogate testing. This includes a new chiller that has been fabricated and testing that has resumed. Additional tests are being conducted, including: using formed aluminum gaskets, extended testing with natural uranium, testing with pseudo-spindle, testing with no vacuum. This lecture includes a look into the Reflector Design. Results for detailed model are consistent with results presented in CED-2. Calculations provide flexibility in the physical design of the reflectors (e.g. reflector segment widths and heights). Provided initial CAD models of reflector components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only SMR technologies, but also Advanced Reactors design. An Electrical Penetration Assembly (EPA) is a component used to allow electrical power and signal conductors as well as optical fiber through the nuclear reactor’s containment structure while maintaining a pressure barrier. The EPA ensures the containment's integrity both during the normal operation and also accident conditions by providing a sealed passage for power and signals. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and also more severe normal operating conditions.This document describes cost effective approaches to qualify a unique EPA for Small Modular Reactor (SMR) technologies as legacy LWR EPA technologies will likely have inherent material performance insufficiencies. The DBA profiles for SMRs (and some Advanced Reactor Technologies) are more severe than the legacy qualification requirements making the design of the qualification testing system challenging as the temperatures and pressures can approach the limits permitted by ASME Pressure Vessel Code, as well as accident temperatures exceeding the capability of polymeric gaskets and dielectrics. Small Modular Reactors are designed to have, as the name suggests, modularity which implies sized for factory fabrication and subsequent assembly at the power plant site. SMR containment is much smaller than a legacy Light Water Reactor containment. The containment walls are likely to be comprised of stainless steel. Qualifying Electrical Penetration Assemblies (EPAs) through these steel vessels are of interest in this work. Methods are presented here that discuss critical safety and cost effectiveness for these SMR EPA’s test systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Detection of Monoclinic Zirconia and Non-Uniform 3D Crystallographic Strain in a Re-Oxidized Ni-YSZ Solid Oxide Fuel Cell Anode

The solid oxide fuel cell (SOFC) anode is often composed of nickel (Ni) and yttria-stabilized zirconia (YSZ). The yttria is added in small quantities (e.g., 8 mol %) to maintain the crystallographic structure throughout the operating temperatures (e.g., room-temperature to >800 °C). The YSZ skeleton provides a constraining structural support that inhibits degradation mechanisms such as Ni agglomeration and thermal expansion miss-match between the anode and electrolyte layers. Within this structure, the Ni is deposited in the oxide form and then reduced during start-up; however, exposure to oxygen (e.g., during gasket failure) readily re-oxidizes the Ni back to NiO, impeding electrochemical performance and introducing complex structural stresses. In this work, we correlate lab-based X-ray computed tomography using zone plate focusing optics, with X-ray synchrotron diffraction computed tomography to explore the crystal structure of a partially re-oxidized Ni/NiO-YSZ electrode. These state-of-the-art techniques expose several novel findings: non-isotropic YSZ lattice distributions; the presence of monoclinic zirconia around the oxidation boundary; and metallic strain complications in the presence of variable yttria content. This work provides evidence that the reduction–oxidation processes may destabilize the YSZ structure, producing monoclinic zirconia and microscopic YSZ strain, which has implications upon the electrode’s mechanical integrity and thus lifetime of the SOFC.

25 ENERGY STORAGE↗

Measuring Very Low Radiation Doses in PTFE for Nuclear Forensic Enrichment Reconstruction

Every country that has made nuclear weapons has used uranium enrichment. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment that can be used to perform forensic verification of historically produced weapons. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon's quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing a detection of tampering and a method for analyzing field samples useful for treaty verification. This work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

Connick, Rachel↗

Pressure seal ring may be effective over wide temperature range

Positive pressure seal rings seal bolted flange joints in pressure vessels containing fluids whose temperatures can vary over a wide range. The seal rings mate with grooves in the flanges and compensate for the excessive thermal expansion or contraction of a gasketed joint.

Source record↗

Thin plastic sheet eliminates need for expensive plating

Gasket of a commercially available plastic material is interposed between the mating surfaces in axial joints where a hard and a soft metal are in intimate contact under stress conditions. This eliminates the fretting problem and is quicker and less expensive than the plating process.

Stremel, R. L.↗