Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GWP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Quasi-Rayleigh waves in butt-welded thick steel plate

This paper discusses theoretical and experimental analyses of weld guided surface acoustic waves (SAW) through the guided wave propagation (GWP) analyses. The GWP analyses have been carried out by utilizing piezoelectric wafer active sensors (PWAS) for in situ structural inspection of a thick steel plate with butt weld as the weld bead is ground flush. Ultrasonic techniques are commonly used for validation of welded structures in many in-situ monitoring applications, e.g. in off-shore structures, in nuclear and pressure vessel industries and in a range of naval applications. PWAS is recently employed in such ultrasonic applications as a resonator as well as a transducer. Quasi-Rayleigh waves a.k.a. SAW can be generated in relatively thick isotropic elastic plate having the same phase velocity as Rayleigh waves whereas Rayleigh waves are a high frequency approximation of the first symmetric (S0) and anti-symmetric (A0) Lamb wave modes. As the frequency becomes very high the S0 and the A0 wave speeds coalesce, and both have the same value. This value is exactly the Rayleigh wave speed and becomes constant along the frequency i.e. Rayleigh waves are non-dispersive guided surface acoustic waves. The study is followed with weld-GWP tests through the pitch-catch method along the butt weld line. The tuning curves of quasi-Rayleigh wave are determined to show the tuning and trapping effect of the weld bead that has higher thickness than the adjacent plates on producing a dominant quasi-Rayleigh wave mode. The significant usage of the weld tuned and guided quasi-Rayleigh wave mode is essentially discussed for the applications in the in-situ inspection of relatively thick structures with butt weld such as naval offshore structures. The paper ends with summary, conclusions and suggestions for future work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compare optimized performance results for packaged RTU using all alternative refrigerants FY17 1st Quarter Milestone Report

Based on the laboratory investigation in FY16, for R-22 and R-410A alternative low GWP refrigerants in two baseline rooftop air conditioners (RTU), we used the DOE/ORNL Heat Pump Design Model to model the two RTUs and calibrated the models against the experimental data. Using the calibrated equipment models, we compared the compressor efficiencies, heat exchanger performances. An efficiency-based compressor mapping method was developed, which is able to predict compressor performances of the alternative low GWP refrigerants accurately. Extensive model-based optimizations were conducted to provide a fair comparison between all the low GWP candidates by selecting their preferred configurations at the same cooling capacity and compressor efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Efficiency Solid State Heat Pump Module

The baseline heat pumping technology today is dominated by vapor compression refrigeration cycle that involves use of global warming potential fluids (e.g. hydrofluorocarbons HFC). Current regulations (e.g. 2016 Kigali agreement) and market needs are driving HVAC&R related building, automotive and aerospace industries to safe, compact and cost-effective systems with low global warming potential (GWP) footprint (i.e. direct GWP impact) and higher efficiencies (i.e. indirect GWP impact) and low life cycle cost. Among the solid-state technology options, electrocaloric heat pumping (ECHP) technology has potential to be more efficient, quiet and compact than vapor compression systems. However, electrocaloric technology is still at low maturity, as expressed by standard technology readiness level (TRL) assessments and hence was the focus of the current effort. During the current research effort, UTRC proved feasibility (TRL2/3) of the direct-air ECHP concept by demonstrating cooling of ambient air by 8.4°C (under no load conditions) in a laboratory environment. To the team’s knowledge this is the largest direct air cooling demonstration using electrocaloric technology. The technology was matured from lab-scale dime-sized materials to module-scale dimensions and further demonstrated the feasibility of integrating these electrocaloric materials into modules for providing direct-air cooling. The use of inexpensive polymer-based materials validates the economic feasibility of the proposed technology. Future effort is required to further mature this promising technology to TRL 4/5 demonstrating module and system performance at full capacity and efficiency. Maturity to beyond TRL4/5 could be done with limited potential field trials. Successful field trials can pave the way for commercialization. At full commercialization, electrocaloric based heating and cooling technologies have the potential to enable annual energy savings upwards of a quadrillion BTUs and reduction of 10s of million metric tons/yr of Green-House Gas (GHG) emissions in the US, leapfrogging emerging technologies and disrupting traditional cooling and heating systems in residential and commercial HVAC applications and enabling new applications. This would result in reduction of energy imports, greenhouse gas (GHG) emissions and help create US jobs in this new technical area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Energy Systems for Transforming CO 2 to Valuable Products (Final Report)

The objective of this project is to develop the Direct E-Beam Synthesis (DEBS) process that uses high-energy electron beams (E-Beam) to break chemical bonds. This allows the production of valuable chemicals, such as acetic acid, methanol, and carbon monoxide, at relatively low severity (pressure near one atmosphere and temperatures <150°C) from near-pure CO 2 captured from a pulverized coal-fired power plant and methane, imported as natural gas. Creating such valuable products will offset the cost of carbon capture and storage. Through this project, we have designed, constructed, and operated an E-Beam reactor to examine the feasibility of performing dry reforming reaction without a catalyst using only DEBS. We have verified the production of syngas with 1:1 H2:CO ratio and calculated that the energy cost for conversion is about 5.2 eV/molecule of product for dry reforming reaction which is similar to the energy cost for conversion using conventional thermochemical conversion but under significantly milder conditions (room temperature and atmospheric pressure). We have performed a technoeconomic analysis (TEA) to estimate the total capital requirement and the cost of production for a 99.4 MMSCFD syngas production plant via non-catalytic Direct E-Beam Synthesis (DEBS) technology utilizing a high-energy electron beam (E-Beam) accelerator. No assumption is made for syngas utilization downstream, and the incoming reactants are pure CO 2 from carbon capture (assumed to be at zero cost) and natural gas. The Total As-Spent Cost (TASC) was calculated to be $\$242.5$ million, resulting in a levelized cost of syngas (LCOS) of $\$175.84$/tonne (metric) at a natural gas price of $\$6.24$/MMBTU1. The cost of syngas is primarily determined by the price of natural gas. If the cost of the CO 2 feedstock is assumed to be non-zero, then the price of the CO 2 feed also heavily influences the levelized cost of syngas. The potential impact on the cost of electricity from syngas revenue is significant. Following DOE NETL’s guidance, a lifecycle analysis (LCA) was conducted to compare the cradle-to-gate life cycle emissions of GTI Energy’s novel Direct E-Beam Synthesis (DEBS) process that produces syngas via the reaction of methane and carbon dioxide to the emissions of a state-of-the-art Steam Methane Reforming (SMR) process that also produces syngas via the reaction of methane and steam. The DEBS process results in less GHG emissions than SMR (with CO product as the basis of comparison). openLCA was used for the LCA and the results show that the total global warming potential (GWP) of DEBS is 0.981 kg CO 2 e per kg CO product, while the SMR process has a global warming potential of 2.573 kg CO 2 e per kg CO product. The ratio of the GWP of the proposed product system to the comparison product system is 0.381. This percent change is 61.9% lower GWP than SMR.

20 FOSSIL-FUELED POWER PLANTS↗

Carbon intensity of mass timber materials: impacts of sourcing and transportation

Mass timber construction is widely considered a promising alternative construction method to reduce buildings’ total life-cycle carbon emissions because wood is a carbon sink. Cross-laminated timber (CLT) panels, manufactured by gluing lumber layers with grains at right angles, are potential low-carbon alternatives to carbon-intensive concrete and steel construction. However, most environmental impact assessment studies do not consider variation in transportation impacts within the CLT supply chain when calculating life-cycle impacts. This study investigates the embodied primary energy and the global warming potential (GWP) of CLT supply chain decisions regarding the type of timber species used, the U.S. region it is sourced from, and the location of the CLT mill. Longer transport distances in the supply chain for timber and CLT panels can contribute as much as 923 MJ/m 2 (20%) of the embodied primary energy of a CLT building, and the use of a higher-density timber species increases this contribution to 1246 MJ/m 2 (24%), with most of that energy derived from fossil energy sources. For perspective, the GWP of a building whose CLT panels and timber have been transported by truck over 6,000 km (252–270 kgCO 2 /m 2 ) is greater than the GWP of an equivalent reinforced concrete (RC) building (245 kgCO 2 /m 2 ). Thus, factors like the location of CLT processing facilities and the type of timber species can significantly impact the overall life-cycle assessment and, if chosen appropriately, can mitigate the environmental impacts of CLT construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inland Water Greenhouse Gas Budgets for RECCAP2: 2. Regionalization and Homogenization of Estimates

Inland waters are important emitters of the greenhouse gasses (GHGs) carbon dioxide (CO 2 ), methane (CH 4 ), and nitrous oxide (N 2 O) to the atmosphere. In the framework of the 2 nd phase of the REgional Carbon Cycle Assessment and Processes (RECCAP-2) initiative, we synthesize existing estimates of GHG emissions from streams, rivers, lakes and reservoirs, and homogenize them with regard to underlying global maps of water surface area distribution and the effects of seasonal ice cover. We then produce regionalized estimates of GHG emissions over 10 extensive land regions. According to our synthesis, inland water GHG emissions have a global warming potential of an equivalent emission of 13.5 (9.9-20.1) and 8.3 (5.7-12.7) Pg CO 2 -eq. yr -1 at a 20 and 100 year horizon (GWP 20 and GWP 100 ), respectively. Contributions of CO 2 dominate GWP100, with rivers being the largest emitter. For GWP 20 , lakes and rivers are equally important emitters, and the warming potential of CH4 is more important than that of CO2. Contributions from N 2 O are about two orders of magnitude lower. Normalized to the area of RECCAP-2 regions, S-America and SE-Asia show the highest emission rates, dominated by riverine CO 2 emissions.

Ronny Lauerwald↗

Options for low–global-warming-potential and natural refrigerants- Performance for heat pump application and analysis of systemic irreversibilities

There is growing interest in substituting existing refrigerants with low global warming potential (GWP) refrigerants, including naturally occurring fluids, to reduce the impact of human activities on climate change. In this study we have evaluated prospective low-GWP refrigerants in four distinct heat pump cycles using the First and Second laws of thermodynamics. The essence of the study is to establish the performance of the low-GWP refrigerants when deployed in a heat pump system. Exergy analysis provides a true measure of lost work, or systemic inefficiencies, vividly quantifying areas of improvement and identifying the preferred cycle for a refrigerant. The combined knowledge of the properties of the phase boundary on either side of the critical point (DOI:10.1.18462/iir.icr.2019.442), and exergy analysis of prospective cycles is necessary for a better perspective on discriminating among refrigerants as hydrochlorofluorocarbons are phased out and replacement refrigerants must be found.

Nawaz, Kashif↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

Options for low-global-warming-potential and natural refrigerants part I: Constrains of the shape of the P–T and T–S saturation phase boundaries

Current research focus is migrating toward low-global-warming-potential (GWP) and natural refrigerants to address the human impact on climate change. In this paper, we examine 13 refrigerants from the perspective of the characteristic shape of their respective temperature–entropy (T–S) and the logarithm of the pressure versus inverse absolute temperature (log P vs. T –1 ) saturated phase boundary. Such analyses explain why certain refrigerants possess a re-entrant characteristic while others do not. The re-entrant region is due to skewness of the saturation boundary. The cause of skewness is investigated for its importance in heat pump performance, design, and configuration. Re-entrant behavior contributes to premature mechanical wear of compressor components. Knowledge of the properties of the phase boundary on either side of the critical point, is useful for a better perspective on discriminating refrigerants, as hydrochlorofluorocarbons are phased out and replacement refrigerants must be found. Here, we conclude by identifying a candidate low-GWP refrigerant for heat pumps. In Part II, we evaluate all 13 refrigerants in thermodynamic cycles based on exergy analysis to identify sources of irreversibility, the root cause of systemic inefficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TEST REPORT #21: Compressor Calorimeter Test of R-404A Alternatives ARM-31a, D2Y-65, L-40, and R32/ R-134a (50/50)

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of four lower-GWP alternative refrigerants, ARM-31a, D2Y-65, L-40, and R-32 + R-134a mixture, to that of refrigerant R-404A (baseline) in a scroll compressor designed for medium temperature refrigeration applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-404A and having a nominal rated capacity of 23,500 Btu/hr. Tests were conducted over a suction dew point temperature range of -10°F to 35°F in 5°F increments and a discharge dew point temperature range of 70°F to 140°F in 10°F increments. All the tests were performed with 20°F superheat, 40°F superheat, and 65°F suction temperature. A liquid subcooling level of 10°F to 15°F was maintained for all the test conditions. However, the cooling capacities reported in this study are normalized for 0°F subcooling. The tests showed that the compressor energy efficiency ratio (EER) and cooling capacity with all four alternative refrigerants tested are higher at higher saturation suction and saturation discharge temperature and lower at lower saturation suction and saturation discharge temperature, compared to that of R-404A. Discharge temperatures of all the alternative refrigerants were higher than that of R-404A at all test conditions.

Alternative Refrigerants↗

Compressor Calorimeter Test of R-410A Alternative: R-32/134a Mixture Using a Scroll Compressor

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of lower-GWP alternative refrigerant R-32 + R-134a mixture, to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-410A and having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10 F to 55 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat, and 65 F suction temperature. A liquid subcooling level of 15 F was maintained for all the test conditions. The tests showed that the discharge temperature of the alternative refrigerant was higher than that of R-410A at all test conditions. Also, the energy efficiency ratio (EER) and cooling capacity of compressor using the alternative refrigerant were slightly lower in comparison to that of R-410A.

Alternative Refrigerants↗

Alternative Refrigerant Evaluation for High-Ambient Temperature Environments: R-22 and R-410A Alternatives for Mini-Split Air Conditioners

The Oak Ridge National Laboratory (ORNL) High-Ambient Temperature Testing Program for Low-GWP Refrigerants aims to develop an understanding of the performance of low-Global Warming Potential (low-GWP) alternatives to Hydrochlorofluorocarbon (HCFC) and Hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high ambient temperature conditions. This interim working paper describes the parties involved, the alternative refrigerants selection process, the test procedures, and the preliminary results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Refrigerant Evaluation for High-Ambient-Temperature Environments: R-22 and R-410A Alternatives for Rooftop Air Conditioners

The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for Low-Global Warming Potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants relative to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in packaged or Rooftop Unit (RTU) air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerants selection process, the test procedures, and the final results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Modeling-Based Flammable Risk Treatment of Refrigerant Leakage from a Commercial R-290 Refrigeration Machine

Because of serious concerns about global warming, manufacturers have started phasing out high global warming potential (GWP) refrigerants in commercial refrigeration equipment (e.g., R-134a). As a potential replacement, propane (R-290) is an environmentally friendly refrigerant for commercial refrigeration equipment because its GWP is only three. However, propane is flammable and is therefore classified as a Class A3 refrigerant per ASHRAE Standards, so safety is a very important consideration when propane-based equipment is designed and deployed in buildings. In the event of a refrigerant leak, flammability of the refrigerant depends on the refrigerant’s local concentration, which is highly affected by the indoor air environment, including temperature and air flow. In this study, a ventilation system attached to a commercial R-290 refrigeration device was designed to eliminate the flammability risk. Moreover, a computational fluid dynamics (CFD) model was developed to investigate the refrigerant leak, thereby evaluating effects of the ventilation system. The CFD model can visualize the flammable zones owing to the leak.

42 ENGINEERING↗

An Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants

Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCP of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.

LCCP↗

Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

GWP↗