Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GELATIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-F-J-176: Development of a Patient-Specific 3D Couplant Pad for Ultrasound IGRT

Purpose: to overcome the several issues of ultrasound image-guided radiation therapy (US IGRT) such as probe pressure and optical tracking disability by using a patient-specific three-dimensional couplant pad (CP) fabricated by a patient’s skin mold using a 3D printing technique. Methods: A CP was then fabricated by pouring gelatin solution into a fixed-shape container accommodating the patient skin mold fabricated by a 3D printer. A breast phantom was fabricated with the compound of gelatin and agarose and a phantom study was carried out. From four patients who underwent US IGRT, total 486 ultrasound images with and without a CP were acquired before treatment. Effectiveness of the use of the CP was evaluated. Results: The positioning accuracies in the phantom study were 0.9 ± 0.3 mm and 1.3 ± 0.4 mm with and without the CP in 3D vector amplitude, respectively. In the patient study, the use of CP reduced the mean target shift from 4.7 mm to 3.7 mm in 3D vector amplitude and the one standard deviation from 2.2 mm to 1.7 mm. It also improved the image contrast around the treatment target by 10 %. The centroid offset of the target volume affected from the US scanning coverage and the target deformation due to the excessive probe pressure was decreased from 4.4 mm to 2.9 mm due to the use of CP. Its difference among three different users was statistically significant (p=0.020) without the use of CP but not significantly different (p=0.133) with the use of CP. Conclusion: Our patient-specific 3D CP using a mold by 3D printing technique is a promising strategy for improving tracking accuracy, image quality, and inter-observer variation for ultrasound-based image guided radiotherapy. In addition to its conventional advantage of non-invasiveness, US can be more facilitated in radiotherapy by the developed CP.

60 APPLIED LIFE SCIENCES↗

The Structure of Radiative Tunnel Recombination Sites in Emulsion Microcrystals of AgBr(I)

To identify the structure of emissive tunnel recombination sites in the emulsion microcrystals of silver bromide AgBr(I) with iodine contaminations and to determine the role of an emulsion medium in their formation, the temperature dependence of the luminescence spectra in the range from 77 to 120 K, the kinetics of the growth of the maximum luminescence intensity value at λ ≈ 560 nm, and the luminescence flash spectrum stimulated by the infrared light are investigated. Two types of the AgBr{sub 1–} {sub x}(I{sub x}) (x = 0.03) microcrystals—namely, obtained in an aqueous solution and on a gelatin substrate—are used in the studies. It is established that the emissive tunnel recombination sites with a luminescence maximum at λ ≈ 560 nm in AgBr{sub 1–} {sub x}(I{sub x}) (x = 0.03) are the {(I_a"-I_a"-)Ag_i"+} donor–acceptor complexes with the I{sub a}{sup -} iodine ions located in neighbor anionic sites of the AgBr(I) crystal lattice, next to which the Ag{sub i}{sup +} interstitial silver ion is positioned. With an increase in the temperature, the {(I_a"-I_a"-)Ag_i"+} sites undergo structural transformation into the {(I_a"-I_a"-)Ag_i_n"+} sites, where n = 2, 3, …. Moreover, the {(I_a"-I_a"-)Ag_i_n"+} sites (n = 2) after the capture of an electron and hole also provide the tunnel recombination with a luminescence maximum at λ ≈ 720 nm. The influence of an emulsion medium consists in that gelatin interacts with the surface electron-localization sites, i.e., the interstitial silver ions Ag{sub in}{sup +}, n = 1, 2, and forms the complexes {Ag_i_n"0 G"+} (n = 1, 2) with them. The latter are deeper electron traps with a small capture cross section as compared to the Ag{sub in}{sup +} sites (n = 1, 2) and that manifest themselves in that the kinetics of the luminescence growth in AgBr(I) to a stationary level at λ ≈ 560 nm is characterized by the presence of “flash firing.” At the same time, the luminescence flash stimulated by IR light, for which the Ag{sub in}{sup +}(n = 1, 2) electron-localization sites are responsible, is absent. It is supposed that the electrons localized on the {Ag_i_n"+G"+} complexes (n = 2) retain the capability for emissive tunnel recombination with holes localized on paired iodine sites with a luminescence maximum at λ ≈ 750 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Complete genome sequence of Weeksella virosa type strain (9751 T )

Weeksella virosa Holmes et al. 1987 is the sole member and type species of the genus Weeksella which belongs to the family Flavobacteriaceae of the phylum Bacteroidetes. Twenty-nine isolates, collected from clinical specimens provided the basis for the taxon description. While the species seems to be a saprophyte of the mucous membranes of healthy man and warm-blooded animals a causal relationship with disease has been reported in a few instances. Except for the ability to produce indole and to hydrolyze Tween and proteins such as casein and gelatin, this aerobic, non-motile, non-pigmented bacterial species is metabolically inert in most traditional biochemical tests. The 2,272,954 bp long genome with its 2,105 protein-coding and 76 RNA genes consists of one circular chromosome and is a part of the Genomic Encyclopedia of Bacteria and Archaea project.

59 BASIC BIOLOGICAL SCIENCES↗

Ophthalmic Artery Embolization as Pretreatment of Orbital Exenteration for Conjunctival Squamous Cell Carcinoma

The aim of this study is to describe the effect of transarterial embolization from the ophthalmic artery as a pretreatment for orbital exenteration. A 75-year-old Chinese man with a 7-year history of gradual increase of the left eye swelling showed a massive conjunctival tumor growing outwardly from the interpalpebral fissure and had no light perception in the left eye. Magnetic resonance imaging showed orbital invasion of the tumor around the left eyeglobe. The initial surgery for the planned orbital exenteration was discontinued after skin incision around the orbital margin due to massive hemorrhage. The patient underwent transarterial embolization with gelatin sponge (Spongel) of the feeding arteries from the left ophthalmic artery and, the next day, had orbital exenteration with well-controllable bleeding and reconstruction with free vascularized anterolateral thigh cutaneous flap transfer. Pathologically, well-differentiated squamous cell carcinoma proliferated in exophytic, papillary, and nested fashions, arising from the bulbar conjunctiva. Tumor cells were also found in the conjunctival stroma around the vessels. The sclera at the equator had a perforated site with tumor cell invasion, but no intraocular invasion was found. Hematoxylin-positive gelatin sponges were found inside the orbital vessels and large choroidal vessels. In conclusion, transarterial embolization of feeding arteries arising from the ophthalmic artery is a useful pretreatment to control bleeding at orbital exenteration for malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cisplatin Pharmacokinetics in Nontumoral Pig Liver Treated With Intravenous or Transarterial Hepatic Chemoembolization

Purpose: To evaluate cisplatin (CDDP) pharmacokinetics after its intravenous (IV) or intrahepatic arterial administration (IHA) in healthy pigs with or without embolization by absorbable gelatine. Material and Methods: We analysed plasmatic and hepatic drug concentration in four groups of six mini-pigs each according to the modality of administration of CDDP (1 mg/kg): IV, IHA, IHA with partial embolization using absorbable gelatine (IHA-Pe), and IHA with complete embolization (IHA-Te). Unbounded plasmatic and hepatic platinum concentrations were measured. Concentration and pharmacokinetics parameters were compared using analysis of variance. Results: For all groups, there was a rapid and biexponential decrease in free platinum concentration. Plasmatic terminal half-life (T{sub 1/2}) was significantly decreased after embolization at 191, 178, 42, and 41 min after IV, IHA, IHA-Pe, and IHA-Te administration, respectively. Maximal plasmatic concentration and systemic exposure to CDDP (AUC{sub 24}) values were significantly decreased after embolization (C{sub max}p = 0.0075; AUC{sub 24}p = 0.0053). Hepatic CDDP concentration rapidly peaked and then decreased progressively. After 24 h, the residual concentration represented 45, 47, 60, and 63 % of C{sub max}, respectively, after IV, IHA, IHA-Pe, and IHA-Te. Hepatic T{sub 1/2} and AUC{sub {infinity}} values were increased after embolization, but the differences were not statistically significant. Conclusion: This preliminary study confirms the feasibility of a pig model to study systemic and hepatic CDDP pharmacokinetics. Systemic exposure is lower after embolization, which could minimize systemic toxicity. Hepatic T{sub 1/2} elimination and hepatic exposition values are increased with IHA compared with IV administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stimulation of Hepatoma Cell Invasiveness and Metastatic Potential by Proteins Secreted From Irradiated Nonparenchymal Cells

Purpose: To determine whether factors secreted by irradiated liver nonparenchymal cells (NPCs) may influence invasiveness and/or metastatic potential of hepatocellular carcinoma (HCC) cells and to elucidate a possible mechanism for such effect. Methods and Materials: Primary rat NPCs were cultured and divided into irradiated (10-Gy X-ray) and nonirradiated groups. Forty-eight hours after irradiation, conditioned medium from irradiated (SR) or nonirradiated (SnonR) cultures were collected and added to sublethally irradiated cultures of the hepatoma McA-RH7777 cell line. Then, hepatoma cells were continuously passaged for eight generations (RH10Gy-SR and RH10Gy-SnonR). The invasiveness and metastatic potential of McA-RH7777, RH10Gy-SnonR, and RH10Gy-SR cells were evaluated using an in vitro gelatinous protein (Matrigel) invasion and an in vivo metastasis assay. In addition, SR and SnonR were tested using rat cytokine antibody arrays and enzyme-linked immunosorbent assay (ELISA). Results: In vitro gelatinous protein invasion assay indicated that the numbers of invading cells was significantly higher in RH10Gy-SR (40 {+-} 4.74) than in RH10Gy-SnonR (30.6 {+-} 3.85) cells, and lowest in McA-RH7777 (11.4 {+-} 3.56) cells. The same pattern was observed in vivo in a lung metastasis assay, as evaluated by number of metastatic lung nodules seen with RH10Gy-SR (28.83 {+-} 5.38), RH10Gy-SnonR (22.17 {+-} 4.26), and McA-RH7777 (8.3 {+-} 3.8) cells. Rat cytokine antibody arrays and ELISA demonstrated that metastasis-promoting cytokines (tumor necrosis factor-{alpha} and interleukin-6), circulating growth factors (vascular endothelial growth factor and epidermal growth factor), and metalloproteinases (MMP-2 and MMP-9) were upregulated in SR compared with SnonR. Conclusions: Radiation can increase invasiveness and metastatic potential of sublethally irradiated hepatoma cells, and soluble mediators released from irradiated NPCs promote this potential. Increased secretion of metastasis-related cytokines and factors from NPCs after irradiation may be a possible mechanism for the radiation-induced invasiveness and metastatic potential of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron X-ray Scattering Analysis of the Interaction Between Corn Starch and an Exogenous Lipid During Hydrothermal Treatment

Lipids have an important effect on starch physicochemical properties. There exist few reports about the effect of exogenous lipids on native corn starch structural properties. In this work, a study of the morphological, structural and thermal properties of native corn starch with L-alpha-lysophosphatidylcholine (LPC, the main phospholipid in corn) was performed under an excess of water. Synchrotron radiation, in the form of real-time small and wide-angle X-ray scattering (SAXS/WAXS), was used in order to track structural changes in corn starch, in the presence of LPC during a heating process from 30 to 85 C. When adding LCP, water absorption decreased within starch granule amorphous regions during gelatinization. This is explained by crystallization of the amylose-LPC inclusion complex during gelatinization, which promotes starch granule thermal stability at up to 95 C. Finally, a conceptual model is proposed for explaining the formation mechanism of the starch-LPC complex.

60 APPLIED LIFE SCIENCES↗

Development of highly porous scaffolds based on bioactive silicates for dental tissue engineering

Graphical abstract: - Highlights: • Synthesis of an Mg-based glass-ceramic via the sol–gel technique. • The heat treatment of the glass-ceramic promoted the crystallization of akermanite. • Akermanite scaffolds coated with gelatin were successfully fabricated. • An HCAp layer was developed on the surface of all scaffolds after 9 days in SBF. - Abstract: Various scaffolding materials, ceramics and especially Mg-based ceramic materials, including akermanite (Ca{sub 2}MgSi{sub 2}O{sub 7}) and diopside (CaMgSi{sub 2}O{sub 6}), have attracted interest for dental tissue regeneration because of their improved mechanical properties and controllable biodegradation. The aim of the present work was the synthesis of an Mg-based glass-ceramic, which would be used for the construction of workable akermanite scaffolds. The characterization of the synthesized material was performed by Fourier Transform Infrared Spectroscopy (FTIR) X-Ray Diffractometry (XRD) and Scanning Electron Microscopy (SEM). Finally, the apatite forming ability of the scaffolds was assessed by immersion in simulated body fluid. The scaffolds were fabricated by the foam replica technique and were subsequently coated with gelatin to provide a functional surface for increased cell attachment. Finally, SEM microphotographs and FTIR spectra of the scaffolds after immersion in SBF solution indicated the inorganic bioactive character of the scaffolds suitable for the intended applications in dental tissue engineering.

36 MATERIALS SCIENCE↗

Surface-Initiated Atom Transfer Radical Polymerization Using Hydrogel Reactors

Atom transfer radical polymerization (ATRP) is a controlled radical polymerization method that enables the synthesis of tailored polymeric materials with low dispersity, highlighting its immense potential for green fabrication of advanced materials. However, its broader implementation is limited by challenges in product isolation, maintaining catalyst activity, and mitigating atmospheric sensitivity arising from oxygen-sensitive metal catalysts. Here, gelatin hydrogels (GHs) are introduced as a soft “reactor” matrix for interfacial ATRP, operating with minimal metal-catalyst loading while exhibiting possibly an organoreductive behavior. This strategy leverages activator regeneration via electron transfer through a ligand–metal charge-transfer (LMCT) mechanism to reduce oxidized metal catalysts within the GH network. Polymerization is evaluated by growing polymer brushes at an active interface formed between GHs swollen in monomer solution and an initiating surface, and sequential growth experiments confirmed that GH-mediated ATRP preserves living character. Under UV illumination, LMCT is activated, producing polymers both at the desired interface and within the GH bulk. UV–Vis spectroscopy revealed active reduction of Cu(II) to Cu(I) along with concentration-dependent complex formation, indicating dynamic coordination chemistry within the hydrogel. The redox-active arginine- and glutamic acid-rich gelatin backbone coordinates and reduces the metal center, enabling ATRP at ppm-level catalyst concentrations. While polymerization proceeds in GH-Cu(II) reactors, adding external mobile ligands to the GH results in longer polymer brushes. Here, the results reported here are exploratory. More experiments are needed to characterize polymer brush growth in GHs and compare it to conventional surface-initiated polymerization in solution.

Absorption↗

An elastography method based on the scanning contact resonance of a piezoelectric cantilever

Purpose: Most tissues may become significantly stiffer than their normal states when there are lesions inside. The tissue's modulus can then act as an identification parameter for clinic diagnosis of tumors or fibrosis, which leads to elastography. This study introduces a novel elastography method that can be used for modulus imaging of superficial organs. Methods: This method is based on the scanning contact-resonance of a unimorph piezoelectric cantilever. The cantilever vibrates in its bending mode with the tip pressed tightly on the sample. The contact resonance frequency of the cantilever-sample system is tracked at each scanning point, from which the sample's modulus can be derived based on a beam dynamic model and a contact mechanics model. Scanning is performed by a three-dimensional motorized stage and the whole system is controlled by a homemade software program based on LabVIEW. Results: Testing onin vitro beef tissues indicates that the fat and the muscle can be easily distinguished using this system, and the accuracy of the modulus measurement can be comparable with that of nanoindentation. Imaging on homemade gelatin phantoms shows that the depth information of the abnormalities can be qualitatively obtained by varying the pressing force. The detection limit of this elastography method is specially examined both experimentally and numerically. Results show that it can detect the typical lesions in superficial organs with the depth of several centimeters. The lateral resolution of this elastography method/system is better than 0.5 mm, and could be further enhanced by using more scanning points. Conclusions: The proposed elastography system can be regarded as a sensitive palpation robot, which may be very promising in early diagnosis of tumors in superficial organs such as breast and thyroid.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-410: Investigation of Treatment Planning Accuracy with the Presence of Magnetic Injection Port (breast Tissue Expander)

Purpose: Mastectomy patients with breast reconstruction usually have a magnetic injection port inside the breast during radiation treatments. The magnet has a very high CT number and produces severe streaking artifact across the entire breast in CT images. Our routine strategy is to replace the artifact volumes with uniform water, and it is necessary to validate that the planned dose, with such an artifact correction, is sufficiently accurate. Methods: A phantom was made with a gelatine-filled container sitting on a Matrixx detector, and the magnetic port was inserted into gelatine with specific depths and orientations. The phantom was scanned on a CT simulator and imported into Eclipse for treatment planning. The dose distribution at the Matrixx detector plane was calculated for raw CT images and artifact-corrected images. The treatment beams were then delivered to the phantom and the dose distributions were acquired by the Matrixx detector. Gamma index was calculated to compare the planned dose and the measurement. Results: Three field sizes (10×10, 15×15 and 20×20) and two depths (50mm and 20mm) were investigated. With the 2%/2mm or 3%/3mm criteria, several points (6–10) failed in the plan for raw CT images, and the number of failure was reduced close to zero for the corrected CT images. An assignment of 10,000 HU to the magnet further reduced the dose error directly under the magnet. Conclusion: It is validated that our routine strategy of artifact correction can effectively reduce the number of failures in the detector plane. It is also recommended to set the magnet with a CT number of 10,000HU, which could potentially improve the dose calculation at the points right behind the magnet.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-09: Thermoacoustic Range Verification with Perfect Co-Registered Overlay of Bragg Peak onto Ultrasound Image

Purpose: The potential of particle therapy has not yet been fully realized due to inaccuracies in range verification. The purpose of this work was to correlate the Bragg peak location with target structure, by overlaying thermoacoustic localization of the Bragg peak onto an ultrasound image. Methods: Pulsed delivery of 50 MeV protons was accomplished by a fast chopper installed between the ion source and the inflector of the 88″ cyclotron at Lawrence Berkeley National Lab. 2 Gy were delivered in 2 µs by a beam with peak current of 2 µA. Thermoacoustic emissions were detected by a cardiac array and Verasonics V1 ultrasound system, which also generated a grayscale ultrasound image. 1024 thermoacoustic pulses were averaged before filtering and one-way beamforming focused signal onto the Bragg peak location with perfect co-registration to the ultrasound images. Data was collected in a room temperature water bath and gelatin phantom with a cavity designed to mimic the intestine, in which gas pockets can displace the Bragg peak. Experiments were performed with the cavity both empty and filled with olive oil. Results: In the waterbath overlays of the Bragg peak agreed with Monte Carlo simulations to within 800±170 µm. Agreement within 1.3 ± 0.2 mm was achieved in the gelatin phantom, although relative stopping powers were estimated only to first order from CT scans. Protoacoustic signals were detected after travel from the Bragg peak through 29 mm and 65 mm of phantom material when the cavity was empty and full of olive oil, respectively. Conclusion: Protoacoustic range verification is feasible with a commercial clinical ultrasound array, but at doses exceeding the clinical realm. Further optimization of both transducer array and injection line chopper is required to enable range verification within a 2 Gy dose limit, which would enable online adaptive treatment. This work was supported in part by a UWM Intramural Instrumentation Grant and by the Director, Office of Science, Office of Nuclear Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. YMQ was supported by a UWM-OUR summer fellowship.

60 APPLIED LIFE SCIENCES↗

Complete genome sequence of Leadbetterella byssophila type strain (4M15 T )

Leadbetterella byssophila Weon et al. 2005 is the type species of the genus Leadbetterella of the family Cytophagaceae in the phylum Bacteroidetes. Members of the phylum Bacteroidetes are widely distributed in nature, especially in aquatic environments. They are of special interest for their ability to degrade complex biopolymers. L. byssophila occupies a rather isolated position in the tree of life and is characterized by its ability to hydrolyze starch and gelatine, but not agar, cellulose or chitin. Here we describe the features of this organism, together with the complete genome sequence, and annotation. L. byssophila is already the 16th member of the family Cytophagaceae whose genome has been sequenced. The 4,059,653 bp long single replicon genome with its 3,613 protein-coding and 53 RNA genes is part of the Genomic Encyclopedia of Bacteria and Archaea project.

59 BASIC BIOLOGICAL SCIENCES↗

Halogenation of microcapsule walls

Procedure for halogenation of confining walls of both gelatin and gelatin-phenolic resin capsules is similar to that used for microencapsulation. Ten percent halogen content renders capsule wall nonburning; any higher content enhances flame-retardant properties of selected internal phase material. Halogenation decreases permeability of wall material to encapsulated materials.

Davis, T. R.↗

Impact resistance of hybrid composite fan blade materials

Improved resistance to foreign object damage was demonstrated for hybrid composite simulated blade specimens. Transply metallic reinforcement offered additional improvement in resistance to gelatin projectile impacts. Metallic leading edge protection permitted equivalent-to-titanium performance of the hybrid composite simulated blade specimen for impacts with 1.27 cm and 2.54 cm (0.50 and 1.00 inch) diameter gelatin spheres.

Friedrich, L. A.↗

Impact response of graphite-epoxy flat laminates using projectiles that simulate aircraft engine encounters

An investigation of the response of a graphite-epoxy material to foreign object impact was made by impacting spherical projectiles of gelatin, ice, and steel normally on flat panels. The observed damage was classified as transverse (stress wave delamination and cracking), penetrative, or structural (gross failure): the minimum, or threshold, velocity to cause each class of damage was established as a function of projectile characteristics. Steel projectiles had the lowest transverse damage threshold, followed by gelatin and ice. Making use of the threshold velocities and assuming that the normal component of velocity produces the damage in nonnormal impacts, a set of impact angles and velocities was established for each projectile material which would result in damage to composite fan blades. Analysis of the operating parameters of a typical turbine fan blade shows that small steel projectiles are most likely to cause delamination and penetration damage to unprotected graphite-epoxy composite fan blades.

Preston, J. L., Jr.↗

Nuclear emulsion measurements of the dose contribution from tissue disintegration stars on the Apollo-Soyuz mission

A total of 996 disintegration stars were prong-counted in two 100 micron llford K.2 emulsions from the dosimeter of the Docking Pilot on Apollo-Soyuz. The change of slope of the distribution at a prong number of about 6 or 7 indicates 219 stars as originating in gelatin. Applying the QF values set forth in official regulations to the energy spectra of the proton and a alpha prongs of the gelatin stars leads to a tissue star dose of 7.8 millirad or 45 millirem. The quoted values do not include the dose contribution from star-produced neutrons since neutrons do not leave visible prongs in emulsion. Nuclear theory, in good agreement with measurements of galactic radiation in the earth's atmosphere, indicates that the dose equivalent from neutrons is about equal to the one from all ionizing secondaries of stars. Application of this proposition to the star prong spectrum found on Apollo-Soyuz would set the total tissue star dose for the mission at approximately 90 millirem.

Schaefer, H. J.↗

Impact behavior of graphite-epoxy simulated fan blades

The response of a graphite-epoxy material, Modmor II/PR-286, to foreign object impact was investigated by impacting spherical projectiles of three different materials - gelatin, ice, and steel - on simulated blade specimens. Visual and metallographic inspection revealed three damage mechanisms: penetration, leading edge bending failure, and stress wave delamination and cracking. The steel projectiles caused penetration damage regardless of the impact location and angle. For the ice and gelatin particles impacting the leading edge, failure was due to large local bending strains, resulting in significant material removal and delamination damage.

Cook, T. S.↗