Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of plutonium activities in soil - 15429

Plutonium (Pu) contamination in soils at the Nevada National Security Site (NNSS) is characterized using Am-241 activity results from gamma spectroscopy (gamma Am-241) analysis. This is done by inferring the Pu activities using Pu to Am-241 ratios developed from Pu and Am-241 results from alpha spectroscopy isotopic analyses (isotopic Pu and isotopic Am-241). Although the isotopic Pu and Am-241 methods can accurately measure isotopic activities within the sampled material, the amount of soil analyzed is small (typically 1 gram [g] of soil). If there is heterogeneity of particle distribution within the contaminated release site soil, isotopic methods may provide results that are not representative of the contaminated site. The degree of potential heterogeneity needs to be considered before using isotopic analyses to characterize a Pu-contaminated site. Results from various Pu-contaminated sites at the NNSS are presented that demonstrate significant heterogeneity. A larger sample size (∼1,600 g) within a Marinelli container is used for the gamma spectroscopy analysis. This greatly reduces the impact of heterogeneously distributed discrete particles and provides results that are more representative of true contaminant activities at the release site. However, this method cannot provide Pu activities and has the potential to provide less accurate results due to the haphazard location of contaminant particles within the Marinelli container at the time of measurement. The distance of particles from the detector would result in some differential self-absorption of the emissions from radioactive particles. As the magnitude of this problem was not previously understood, a study was conducted to evaluate the variability in Am-241 results due to self-absorption from particle position. Results from this study are shown that demonstrate that this effect provides minimal variability in replicate Am-241 measurements. The method used at the NNSS to characterize Pu activities in soil takes advantage of the accuracy of the alpha spectroscopy isotopic analyses to establish Pu to Am-241 ratios and the more representative gamma spectroscopy results for Am-241 to provide a reliable characterization of Pu activities at contaminant release sites. (authors)

54 ENVIRONMENTAL SCIENCES↗

Optimized Derivative Kernels for Gamma Ray Spectroscopy

In gamma ray spectroscopy, the photon detectors measure the number of photons with energy that lies in an interval which is called a channel. This accumulation of counts produce a measuring function that its deviation from the ideal one may produce high noise in the unfolded spectrum. In order to deal with this problem, the ideal accumulation function is interpolated with the use of special designed derivative kernels. Simulation results are presented which show that this approach is very effective even in spectra with low statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Studies On Nuclear Phenomena At The Extremes Using {gamma}-ray Spectroscopy

The {gamma}-decay of the excited nucleus provides experimental information on the nuclear structure properties at extreme conditions of temperature, angular momentum and isospin. First, the order-to-chaos transition is studied in the warm rotating {sup 163}Er nucleus, in terms of vanishing of selection rules on the K quantum number. Second, the properties of the excited superdeformed bands in {sup 151}Tb and {sup 196}Pb nuclei are investigated in connection with their decay-out into the low deformation states. Finally, the population of highly excited low-spin states in moderately neutron-rich systems is discussed in connection with deep-inelastic reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated SQUID/Sensor Metallic Magnetic Microcalorimeter for Gamma-Ray Spectroscopy

Metallic magnetic microcalorimeters (MMCs) achieve energy resolution comparable to transition-edge sensors (TESs) but rely on different measurement physics that may allow MMCs to surpass TESs in some future applications. We have recently completed fabrication of new MMC γ-ray detector arrays using several exploratory sensor designs. All designs integrate the SQUID and sensor on the same chip and use a superconducting cap layer on the paramagnet, but explore different combinations of combined/separate sensing and magnetization coils and direct/flux transformer coupling to the input SQUIDs. This report describes the design and initial testing of one of these devices, which has so far demonstrated an energy resolution of 38 eV at 60 keV near 10 mK using natural-abundance silver–erbium paramagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gamma ray spectroscopy in astrophysics: Solar gamma ray astronomy on solar maximum mission

The SMM gamma ray experiment and the important scientific capabilities of the instrument are discussed. The flare size detectable as a function of spectrum integration time was studied. A preliminary estimate indicates that a solar gamma ray line at 4.4 MeV one-fifth the intensity of that believed to have been emitted on 4 August 1972 can be detected in approximately 1000 sec with a confidence level of 99%.

Forrest, D. J.↗

First in-beam {gamma}-ray spectroscopy study of {sup 24}Al and its implications for the astrophysical {sup 23}Mg(p,{gamma}){sup 24}Al reaction rate in ONe novae

The first in-beam {gamma}-ray spectroscopy study of {sup 24}Al is presented. A complete level structure of {sup 24}Al incorporating all states below the proton-emission threshold, has been constructed. The first excited state above the proton threshold has also been identified as a 3{sup +} state at 2345.1 {+-} 1.4 keV. This state, corresponding to a resonance energy of 473 {+-} 3 keV, has been suggested to be the dominant resonance contributing to the {sup 23}Mg(p,{gamma}){sup 24}Al stellar reaction rate. The improved precision of the level energy and unambiguous assignment of the state has reduced the uncertainty of the {sup 23}Mg(p,{gamma}){sup 24}Al stellar reaction rate, which constrains the production of A>20 nuclei in ONe novae.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Method to Estimate the Atomic Number and Mass Thickness of Intervening Materials in Uranium and Plutonium Gamma-Ray Spectroscopy Measurements

To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗