Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Modulated Fourier Transform Raman Fiber-Optic Spectroscopy

A modification to a commercial Fourier Transform (FT) Raman spectrometer is presented for the elimination of thermal backgrounds in the FT Raman spectra. The modification involves the use of a mechanical optical chopper to modulate the continuous wave laser, remote collection of the signal via fiber optics, and connection of a dual-phase digital-signal-processor (DSP) lock-in amplifier between the detector and the spectrometer's collection electronics to demodulate and filter the optical signals. The resulting Modulated Fourier Transform Raman Fiber-Optic Spectrometer is capable of completely eliminating thermal backgrounds at temperatures exceeding 300 C.

Jensen, Brian J.↗

A new hybrid algorithm for computing a fast discrete Fourier transform

For certain long transform lengths, Winograd's algorithm for computing the discrete Fourier transform is extended considerably. This is accomplished by performing the cyclic convolution, required by Winograd's method, with the Mersenne-prime number theoretic transform. This new algorithm requires fewer multiplications than either the standard fast Fourier transform or Winograd's more conventional algorithm.

Reed, I. S.↗

Modified algorithms for image inpainting in Fourier transform domain

One of the aims of image inpainting is recovering an image some of which Fourier transform coefficients are lost. In this area, the algorithm of iterative coupled transform domain (ICTDI) has been given by Li and Zeng (SIAM J Imaging Sci 9:24–51, 2016). In this paper, we present some modified algorithms of ICTDI and prove their convergence. In fact, we consider the effect of spectrum and phase angle of the Fourier transform, separately. Therefore, in comparison with ICTDI, one more regularization parameter is generated, and hence, we have more degree of freedom, and therefore, in general, we expect a more appropriate solution.

97 MATHEMATICS AND COMPUTING↗

Improved ion optics for introduction of ions into a 9.4-T Fourier transform ion cyclotron resonance mass spectrometer

Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry provides unparalleled mass accuracy and resolving power.[1],[2] With electrospray ionization (ESI), ions are typically transferred into the mass spectrometer through a skimmer, which serves as a conductance-limiting orifice. However, the skimmer allows only a small fraction of incoming ions to enter the mass spectrometer. An ion funnel, originally developed by Smith and coworkers at Pacific Northwest National Laboratory (PNNL)[3-5] provides much more efficient ion focusing and transfer. The large entrance aperture of the ion funnel allows almost all ions emanating from a heated capillary to be efficiently captured and transferred, resulting in nearly lossless transmission.

42 ENGINEERING↗

Raman spectroscopy of gases with a Fourier transform spectrometer - The spectrum of D2

Fourier transform spectrometry (FTS) is presently used to record the spontaneous incoherent laser Raman spectra of gases. The high resolution, sensitivity, calibration accuracy and spectral coverage achieved demonstrate the viability of FTS for Raman spectroscopy. Attention is given to the coefficients obtained by fitting measurements obtained from the spectrum of D2, containing both v = 0-0 and 1-0 transitions, to the Dunham (1932) expansion of the vibration-rotation energy levels.

Jennings, D. E.↗

Using single buffers and data reorganization to implement a multi-megasample fast Fourier transform

Data ordering in large fast Fourier transforms (FFT's) is both conceptually and implementationally difficult. Discribed here is a method of visualizing data orderings as vectors of address bits, which enables the engineer to use more efficient data orderings and reduce double-buffer memory designs. Also detailed are the difficulties and algorithmic solutions involved in FFT lengths up to 4 megasamples (Msamples) and sample rates up to 80 MHz.

Brown, R. D.↗

Image Stability Requirements For a Geostationary Imaging Fourier Transform Spectrometer (GIFTS)

A Geostationary Imaging Fourier Transform Spectrometer (GIFTS) has been selected for the NASA New Millennium Program (NMP) Earth Observing-3 (EO-3) mission. Our paper will discuss one of the key GIFTS measurement requirements, Field of View (FOV) stability, and its impact on required system performance. The GIFTS NMP mission is designed to demonstrate new and emerging sensor and data processing technologies with the goal of making revolutionary improvements in meteorological observational capability and forecasting accuracy. The GIFTS payload is a versatile imaging FTS with programmable spectral resolution and spatial scene selection that allows radiometric accuracy and atmospheric sounding precision to be traded in near real time for area coverage. The GIFTS sensor combines high sensitivity with a massively parallel spatial data collection scheme to allow high spatial resolution measurement of the Earth's atmosphere and rapid broad area coverage. An objective of the GIFTS mission is to demonstrate the advantages of high spatial resolution (4 km ground sample distance - gsd) on temperature and water vapor retrieval by allowing sampling in broken cloud regions. This small gsd, combined with the relatively long scan time required (approximately 10 s) to collect high resolution spectra from geostationary (GEO) orbit, may require extremely good pointing control. This paper discusses the analysis of this requirement.

Bingham, G. E.↗

Laser Mode Behavior of the Cassini CIRS Fourier Transform Spectrometer at Saturn

The CIRS Fourier transform spectrometer aboard the NASA/ESA/ASI Cassini orbiter has been acquiring spectra of the Saturnian system since 2004. The CIRS reference interferometer employs a laser diode to trigger the interferogram sampling. Although the control of laser diode drive current and operating temperature are stringent enough to restrict laser wavelength variation to a small fraction of CIRS finest resolution element, the CIRS instrument does need to be restarted every year or two, at which time it may start in a new laser mode. By monitoring the Mylar absorption features in uncalibrated spectra due to the beam splitter Mylar substrate, it can be shown that these jumps are to adjacent modes and that most of the eight-year operation so far is restricted to three adjacent modes. For a given mode, the wavelength stability appears consistent with the stability of the laser diode drive curren.t and operating temperature.

Brasunas, John C.↗

A new hybrid algorithm for computing a fast discrete Fourier transform

In this paper for certain long transform lengths, Winograd's algorithm for computing the discrete Fourier transform (DFT) is extended considerably. This is accomplished by performing the cyclic convolution, required by Winograd's method, with the Mersenne prime number-theoretic transform developed originally by Rader. This new algorithm requires fewer multiplications than either the standard fast Fourier transform (FFT) or Winograd's more conventional algorithm. However, more additions are required.

Reed, I. S.↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

A boostrap algorithm for temporal signal reconstruction in the presence of noise from its fractional Fourier transformed intensity spectra

A bootstrap algorithm for reconstructing the temporal signal from four of its fractional Fourier intensity spectra in the presence of noise is described. An optical arrangement is proposed which realises the bootstrap method for the measurement of ultrashort laser pulses. The measurement of short laser pulses which are less than 1 ps is an ongoing challenge in optical physics. One reason is that no oscilloscope exists today which can directly measure the time structure of these pulses and so it becomes necessary to invent other techniques which indirectly provide the necessary information for temporal pulse reconstruction. One method called FROG (frequency resolved optical gating) has been in use since 19911 and is one of the popular methods for recovering these types of short pulses. The idea behind FROG is the use of multiple time-correlated pulse measurements in the frequency domain for the reconstruction. Multiple data sets are required because only intensity information is recorded and not phase, and thus by collecting multiple data sets, there is enough redundant measurements to yield the original time structure, but not necessarily uniquely (or even up to an arbitrary constant phase offset). The objective of this paper is to describe another method which is simpler than FROG. Instead of collecting many auto-correlated data sets, only two spectral intensity measurements of the temporal signal are needed in the absence of noise. The first can be from the intensity components of its usual Fourier transform and the second from its FrFT (fractional Fourier transform). In the presence of noise, a minimum of four measurements are required with the same FrFT order but with two different apertures. Armed with these two or four measurements, a unique solution up to a constant phase offset can be constructed.

43 PARTICLE ACCELERATORS↗

Discrete Fourier Transform Analysis in a Complex Vector Space

Alternative computational strategies for the Discrete Fourier Transform (DFT) have been developed using analysis of geometric manifolds. This approach provides a general framework for performing DFT calculations, and suggests a more efficient implementation of the DFT for applications using iterative transform methods, particularly phase retrieval. The DFT can thus be implemented using fewer operations when compared to the usual DFT counterpart. The software decreases the run time of the DFT in certain applications such as phase retrieval that iteratively call the DFT function. The algorithm exploits a special computational approach based on analysis of the DFT as a transformation in a complex vector space. As such, this approach has the potential to realize a DFT computation that approaches N operations versus Nlog(N) operations for the equivalent Fast Fourier Transform (FFT) calculation.

Dean, Bruce H.↗

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-O IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 micron (1000-4000/cm) to allow high-resolution, high-speed hyperspectral imaging applications. One application will be the remote sensing of the measurement of a large number of different atmospheric gases simultaneously in the same airmass. Due to the use of a combination of birefringent phase retarders and multiple achromatic phase switches to achieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventional Fourier transform spectrometer but without any moving parts. In this paper, the principle of operations, system architecture and recent experimental progress will be presented.

liquid crystal achromatic phase switch↗