Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flowmeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electrodynamic induction flowmeter

Device determines velocity and electrical conductivity of a moving fluid of high electrical resistance by imposing a transverse electro-quasistatic field on the fluid. Position changes of charge accumulations induced within the fluid by the field are sensed by relative movement between fluid and sensor.

Melcher, J. A.↗

Particle-fluid interaction corrections for flow measurements with a laser Doppler flowmeter

A discussion is given of particle lags in mean flows, acoustic oscillations at single frequencies and in turbulent flows. Some simplified cases lead to exact solutions. For turbulent flows linearization of the equation of motion after assuming the fluid and particle streamlines coincide also leads to a solution. The results show that particle lags are a function of particle size and frequency of oscillation. Additional studies are necessary to evaluate the effect of turbulence when a major portion of the energy is concentrated in small eddies.

Berman, N. S.↗

A multichannel electromagnetic flowmeter telemetry system.

An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.

Fryer, T. B.↗

Evaluation of a pulsed ultrasonic Doppler flowmeter

The in vivo application of the pulsed ultrasound Doppler velocity meter (PUDVM) for measuring arterial velocity waveforms is reported. In particular, the performance of the PUDVM is compared with a hot film anemometer of proven accuracy.

Wells, M. K.↗

Discharge coefficient correlations for circular-arc venturi flowmeters at critical /sonic/ flow

Experimental data are analyzed to support theoretical predictions for discharge coefficients in circular-arc venturi flow meters operating in the critical sonic flow regime at throat Reynolds numbers above 150 thousand. The data tend to verify the predicted 0.25% decrease in the discharge coefficient during transition from a laminar to turbulent boundary layer. Four different test gases and three flow measurement facilities were used in the experiments with 17 venturis with throat sizes from 0.15 to 1.37 in. and Beta ratios ranging from 0.014 to 0.25. Recommendations are given as to how the effectiveness of future studies in the field could be improved.

Arnberg, B. T.↗

Inexpensive mass flowmeter

Device measures drag of body with known drag coefficient to determine flow rate. Drag on target is transferred by cantilevered arm to fully active strain-gage bridge. Given target will be useful with many types of fluids and flow rates.

Harman, H. S.↗

Nonintrusive Flowmeter

The results of analytical and experimental work performed in the design, fabrication, and test of a prototype nonintrusive gaging system for use in monitoring the consumption of earth-storable fuels and oxidants in either a one-g or a zero-g environment are explained. The design specifications were those applicable to the reaction control system and to the orbital maneuvering system (OMS) fuel and oxidant on the space shuttle while in orbit. The major requirement was for the measurement of flow pulses with sufficient accuracy to provide a continuous knowledge of the fuel and oxidant remaining in the OMS system to within 1% or better. An ultrasonic frequency chirp technique was used having a high inherent rejection for signals traversing stray paths, and for random noise generated by the flowing liquid. A detailed analysis of the frequency chirp approach for two modes of operation (period and phase changes), including an error analysis are reported.

Greene, M. W.↗

Obtaining an electrical output from a mechanical flowmeter

Circuit using optical sensor, low power counting electronics, oneclip digital-to-analog converter and operational amplifier converts mechanical readout of water, gas, fuel-oil or power meter to analog signal suitable for online processings.

Powers, W. T.↗

An intercomparison of NEL and DHL water flow facilities using a twin orifice plate flowmeter assembly

A 205 mm transfer standard orifice plate meter assembly, consisting of two orifice plates in series separated by a length of pipe containing a flow straightener, was calibrated in two water flow facilities. Results show that the agreement in the characteristics of such a differential pressure transfer standard package is within 0.17% over a 10:1 range from flow rates of approximately 8 to 80 l/sec. When the range over which the comparison was made was limited to that for which the calibration graphs gave straight lines, the agreement is 0.1% in 3 of the 4 calibrations (0.17% in the fourth).

Dejong, J.↗

Flowmeter for Clear and Translucent Fluids

Transducer with only three moving parts senses flow of clear or translucent fluid. Displacement of diaphragm by force of flow detected electrooptically and displayed by panel meter or other device. Transducer used to measure flow of gasoline to automobile engine.

White, P. R.↗

Behavior of turbine and Venturi flowmeters in superfluid helium

An apparatus which forces liquid helium from a calibrated bellows through a flow meter is used to calibrate turbine and Venturi flow meters in both normal and superfluid helium. The bellows are driven by an ambient temperature stepping motor. Flow rates range up to 0.35 L/s, and helium temperatures range from 1.25-4.0 K. For the case of a 9.3-mm bore turbine meter, identical meter factors are found for normal and superfluid helium. For the Venturi meter, discharge coefficients between 0.98 and 1.0 are found with normal and superfluid helium.

Daney, D. E.↗

STS-51 pad abort. OV103-engine 2033 (ME-2) fuel flowmeter sensor open circuit

The STS-51 initial launch attempt of Discovery (OV-103) was terminated on KSC launch pad 39B on 12 Aug. 1993 at 9:12 AM E.S.T. due to a sensor redundancy failure in the liquid hydrogen system of ME-2 (Engine 2033). The event description and time line are summarized. Propellant loading was initiated on 12 Aug. 1993 at 12:00 AM EST. All space shuttle main engine (SSME) chill parameters and Launch Commit Criteria (LCC) were nominal. At engine start plus 1.34 seconds a Failure Identification (FID) was posted against Engine 2033 for exceeding the 1800 spin intra-channel (A1-A2) Fuel Flowrate sensor channel qualification limit. The engine was shut down at 1.50 seconds followed by Engines 2032 and 2030. All shut down sequences were nominal and the mission was safely aborted. SSME Avionics hardware and software performed nominally during the incident. A review of vehicle data table (VDT) data and controller software logic revealed no failure indications other than the single FID 111-101, Fuel Flowrate Intra-Channel Test Channel A disqualification. Software logic was executed according to requirements and there was no anomalous controller software operation. Immediately following the abort, a Rocketdyne/NASA failure investigation team was assembled. The team successfully isolated the failure cause to an open circuit in a Fuel Flowrate Sensor. This type of failure has occurred eight previous times in ground testing. The sensor had performed acceptably on three previous flights of the engine and SSME flight history shows 684 combined fuel flow rate sensor channel flights without failure. The disqualification of an Engine 2 (SSME No. 2033) Fuel Flowrate sensor channel was a result of an instrumentation failure and not engine performance. All other engine operations were nominal. This disqualification resulted in an engine shutdown and safe sequential shutdown of all three engines prior to ignition of the solid boosters.

Source record↗