An Innovative Very Low Thermal Power Waste Heat Recovery System for Thermal Control of Deep Space Missions: A Thermal Flask in Space

Future missions to deep space, such as those to the outer planets (Jupiter, Saturn, etc.), which would rely on solar photovoltaic power, would need extremely large solar arrays to produce sufficient power for their operations because solar intensity is so low at those locations. Hence any additional power that would be needed for thermal control is extremely limited. Previous deep space missions like Juno (to Jupiter) required almost 200 W of electrical power for thermal control. This is prohibitively large for many future mission concepts, and leads to them needing very large solar arrays. For Saturn, where the solar flux is 1/4th the flux at Jupiter, this would entail an extremely large increase in the solar array size to accommodate the need for thermal survival power, which would be prohibitively large in size and mass, and very expensive. Hence there is a need to come up with a thermal architecture and design options that would not need such prohibitively large thermal power levels. One solution relies on harvesting the pre-existing waste heat from all the heat dissipation that would be present from operation of electronics, instruments, etc. for their own functionality. For example, for a generic Saturn mission, the various electronics would already dissipate about 200 Watts of heat that is simply "thrown away" to space from the spacecraft surfaces. The amount of thermal power that would be required for the safe thermal control of components within the spacecraft in deep space would be roughly of this magnitude for this class of spacecraft. So it makes good sense to try to harvest the waste heat and employ it to maintain the temperatures of all the components within their allowable limits. In particular, propulsion systems typically need to be kept above their freezing limits, around room temperature (15 C). Electronics needs to be kept typically above -40 C and batteries above -20 C. The next question becomes how to harvest this waste heat and direct it to the components that would need it for their survival. The proposed system utilizes a mechanically pumped, single phase fluid loop to pick up the waste heat from components attached to this loop's tubing and then directed to a thermal flask that has tubing attached to it. The thermal flask is cylindrically shaped and contains essentially all systems and components in the spacecraft within it, with the exception of the solar array, antennae, thrusters and various apertures of instruments, etc. to allow them an unobstructed view of space. Waste heat from the heat-dissipating components warms up the fluid and is carried to the flask surface and deposited on it via the fluid loop's flow. The entire flask is covered with Multi-Layered Insulation (MLI) to minimize the heat loss from the flask and allow it to remain warm. Hence the flask essentially creates a thermal environment within which the spacecraft components reside. The temperature of the components within the flask is then essentially the same as the temperature of the flask. This approach could be a very enabling feature for deep space missions. This paper describes the approach utilized for this thermal architecture, along with its mechanical and implementation aspects. Additionally it will compare and contrast this approach with the more conventional solutions utilized earlier.

Bhandari, Pradeep↗

Thermal Design Challenges Posed by the Four Bed CO2 Scrubber COTS Air-Save Pump

The Four Bed Carbon Dioxide (4BCO2) scrubber Air-Save Pump (ASP) operates as part of the adsorbent bed regeneration cycle. The ASP removes residual air from the bed for return to the cabin prior to heat and vacuum exposure which drives out the CO2 regenerating the bed. 4BCO2 employs a Commercial Off-the-Shelf (COTS) scroll type air pump, repackaged in an acoustically insulated enclosure to reduce noise and mounted to a cold plate. The International Space Station (ISS) Low Temperature Loop (LTL) flow (operating between 38°F and 50°F) first cools the process air, and then flows through the cold plate, cooling the pump. This results in competing ASP thermal design goals: (1) to keep the pump and motor sufficiently cool and (2) to avoid forming condensation due to over-cooling. Surfaces below 60°F typically warrant careful consideration of condensation. A test-calibrated thermal model demonstrates such a balanced design is feasible with temperatures above 60°F. A separate, coupled fluid model predicts the potential for condensation formation, allowing risk assessment of flying with the unmodified design.

Daniel P Popok↗

Maxar Electric Propulsion Development for Deep Space

Maxar has completed development activity for its deep-space electric propulsion system in support of NASA’s Psyche mission. Psyche’s electric propulsion system relies heavily on Maxar’s heritage EP-140 subsystem centered on the SPT-140. The evolution to the EP-140DS demonstrates an expanded thruster discharge capability from 0.9kW through 4.5kW and includes the addition of a constant keeper current function. This system, with development support from industry experts at JPL, will serve as the primary propulsion on board the Psyche spacecraft through the 3.6 year cruise to the Psyche asteroid. Subsystem level testing to validate the first EP-140DS design is complete. Major findings from system testing including xenon flow control loop timing, noise hardening, and constant keeper current and test activities are now being implemented in hardware and the status and plans are discussed.

Chaplin, Vernon↗

Determination of Heritage SSME Pogo Suppressor Resistance and Inertance from Waterflow Pulse Testing

Waterflow tests of a heritage Space Shuttle Main Engine pogo suppressor were performed to experimentally quantify the resistance and inertance provided by the suppressor. Measurements of dynamic pressure and flow rate in response to pulsing flow were made throughout the test loop. A unique system identification methodology combined all sensor measurements with a one-dimensional perturbational flow model of the complete water flow loop to spatially translate physical measurements to the device under test. Multiple techniques were then employed to extract the effective resistance and inertance for the pogo suppressor. Parameters such as steady flow rate, perturbational flow rate magnitude, and pulse frequency were investigated to assess their influence on the behavior of the pogo suppressor dynamic response. These results support validation of the RS-25 pogo suppressor performance for use on the Space Launch System Core Stage.

McDougal, Chris↗

MHD Modelling of Coronal Loops: Injection of High-Speed Chromospheric Flows

Context. Observations reveal a correspondence between chromospheric type II spicules and bright upward-moving fronts in the corona observed in the extreme-ultraviolet (EUV) band. However, theoretical considerations suggest that these flows are probably not the main source of heating in coronal magnetic loops. Aims. We investigate the propagation of high-speed chromospheric flows into coronal magnetic flux tubes and the possible production of emission in the EUV band. Methods. We simulated the propagation of a dense 104 K chromospheric jet upward along a coronal loop by means of a 2D cylindrical MHD model that includes gravity, radiative losses, thermal conduction, and magnetic induction. The jet propagates in a complete atmosphere including the chromosphere and a tenuous cool (approximately 0.8 MK) corona, linked through a steep transition region. In our reference model, the jet initial speed is 70 km per second, its initial density is 10(exp 11) per cubic centimeter, and the ambient uniform magnetic field is 10 G. We also explored other values of jet speed and density in 1D and different magnetic field values in 2D, as well as the jet propagation in a hotter (approximately 1.5 MK) background loop. Results. While the initial speed of the jet does not allow it to reach the loop apex, a hot shock-front develops ahead of it and travels to the other extreme of the loop. The shock front compresses the coronal plasma and heats it to about 10(exp 6) K. As a result, a bright moving front becomes visible in the 171 Angstrom channel of the SDO/AIA mission. This result generally applies to all the other explored cases, except for the propagation in the hotter loop. Conclusions. For a cool, low-density initial coronal loop, the post-shock plasma ahead of upward chromospheric flows might explain at least part of the observed correspondence between type II spicules and EUV emission excess.

Sun: chromosphere↗

Closed-Loop Control of Vortex Formation in Separated Flows

In order to phase lock the flow at the desired shedding cycle, particularly at Phi,best, We designed a feedback compensator. (Even though the open-loop forcing at Wf below Wn can lead to phase-locked limit cycles with a high average lift,) This feedback controller resulted in the phase-locked limit cycles that the open-loop control could not achieve for alpha=30 and 40 Particularly for alpha=40, the feedback was able to stabilize the limit cycle that was not stable with any of the open-loop periodic forcing. This results in stable phase-locked limit cycles for a larger range of forcing frequencies than the open-loop control. Also, it was shown that the feedback achieved the high-lift unsteady flow states that open-loop control could not sustain even after the states have been achieved for a long period of time.

Colonius, Tim↗

Condition of the Ross Ice Shelf derived from AVHRR imagery

Advanced Very High Resolution Radiometer (AVHRR) satellite imagery is combined with the Ross Ice Shelf Geophysical and Glaciological Survey (RIGGS) data to study recent changes on the Ross Ice Shelf. Flow stripes that appear on the AVHRR imagery agree with significant changes in ice flow that have occurred over the past 1,100 years on the ice shelf sector fed by East Antarctica. A large looping pattern of flow stripes that disagrees with RIGGS flow lines appears west of Crary Ice Rise, on the eastern part of the ice shelf. This looped pattern is interpreted as relict flow stripes related to past activity of a major ice stream of West Antarctica, which occurred about 800 years ago.

Casassa, Gino↗

Heat exchanger with oscillating flow

Various heat exchange apparatuses are described in which an oscillating flow of primary coolant is used to dissipate an incident heat flux. The oscillating flow may be imparted by a reciprocating piston, a double action twin reciprocating piston, fluidic oscillators, or electromagnetic pumps. The oscillating fluid flows through at least one conduit in either an open loop or a closed loop. A secondary flow of coolant may be used to flow over the outer walls of at least one conduit to remove heat transferred from the primary coolant to the walls of the conduit.

Scotti, Stephen J.↗

Heat exchanger with oscillating flow

Various heat exchange apparatuses are described in which an oscillating flow of primary coolant is used to dissipate an incident heat flux. The oscillating flow may be imparted by a reciprocating piston, a double action twin reciprocating piston, fluidic oscillators or electromagnetic pumps. The oscillating fluid flows through at least one conduit in either an open loop or a closed loop. A secondary flow of coolant may be used to flow over the outer walls of at least one conduit to remove heat transferred from the primary coolant to the walls of the conduit.

Scotti, Stephen J.↗

Fuel control for gas turbine with continuous pilot flame

An improved fuel control for a gas turbine engine having a continuous pilot flame and a fuel distribution system including a pump drawing fuel from a source and supplying a line to the main fuel nozzle of the engine, the improvement being a control loop between the pump outlet and the pump inlet to bypass fuel, an electronically controlled throttle valve to restrict flow in the control loop when main nozzle demand exists and to permit substantially unrestricted flow without main nozzle demand, a minimum flow valve in the control loop downstream of the throttle valve to maintain a minimum pressure in the loop ahead of the flow valve, a branch tube from the pilot flame nozzle to the control loop between the throttle valve and the minimum flow valve, an orifice in the branch tube, and a feedback tube from the branch tube downstream of the orifice to the minimum flow valve, the minimum flow valve being operative to maintain a substantially constant pressure differential across the orifice to maintain constant fuel flow to the pilot flame nozzle.

Swick, Robert M.↗

A siphon mechanism for supplying prominence mass

A siphonlike mechanism for moving mass from the chromosphere to a gravitational well at the top of a magnetic loop to form a prominence is examined. The calculations assume no a priori flow velocity at the loop base. Instead, heating in the loop legs drives the flow. The prominence formation process requires two steps. First, the background heating rate must be reduced to on the order of 1 percent of the initial heating rate required to maintain the coronal loop. This forms an initial condensation at the top of the loop. Second, the heating must take place only in the loop legs in order to produce a pressure differential which drives mass up into the well at the top of the loop. The heating rate in the loop must be increased once the prominence has begun to form, or full prominence densities cannot be achieved in a reasonable time. It is concluded that this heating driven siphonlike mechanism is feasible for producing and maintaining prominences.

Poland, A. I.↗

An Overview of the XRT Observations for the September 10 2017 X Flare

The September 10 2017 X8 flare was one of the biggest of the current solar cycle, and it was also incredibly well observed. This presentation will review the available XRT data for this flare. XRT observed the initial flux rope eruption, which was also well observed by AIA and SUVI. XRT data is missing for some of the impulsive phase of the flare, but the late phase shows some very interesting features. There is some nice XRT imaging of a plasma sheet above cusp-shaped loops between 16:47 and 18:39 UT. After 18:40 UT, a double loop structure becomes apparent, with a more rounded loop nested within a larger, cusp-shaped structure. The flare loops continue to grow, and at around 1 UT on September 11, supra-arcade down flows and shrinking loops become visible. There is also interesting data in the late phase of this flare from RHESSI and the Expanded Owens Valley Solar Array (EOVSA).

Reeves, Kathy↗

The effects of nonequilibrium ionization on the radiative losses of the solar corona

The emissivity of the ions of carbon and oxygen has been recalculated for a set of solar coronal loop models with a steady state siphon flow. The ion densities were calculated from the plasma velocities, temperatures, and densities of the models, and large departures from equilibrium were found. For purposes of comparison, the emissivity was calculated with and without the approximation of ionization equilibrium. Considerable differences in the radiative loss function Lambda(T) curve between equilibrium and nonequilibrium conditions were found. The nonequilibrium Lambda(T) function was then used to solve again the steady state flow equations of the loop models. The differences in the structure of these models with respect to the models calculated adopting the Lambda(T) curve in equilibrium are discussed.

Spadaro, D.↗

Low Flow Vortex Shedding Flow Meter for Hypergolics/all Media

A family of vortex shedding flow meters, for measurement of hypergol flows, was designed and fabricated. The test loops to evaluate the flow meters for water flow, as well as Freon -113 flow which simulates the hypergolic fluids, were modified and constructed to utilize a pump system which has an output capacity of 200 gpm. Test runs were conducted on the small 1/2 inch model with Freon 113 and on the larger models with water. Results showed that the linearity between the frequency of the vortices and the flow rate of the fluids was very close to that of the turbine flow meter. It is suggested that the vortex shedding flow meter is a possible replacement for the existing turbine type.

Thinh, Ngo Dinh↗

A study of two-phase flow in a reduced gravity environment

A test loop was designed and fabricated for observing and measuring pressure drops of two-phase flow in reduced gravity. The portable flow test loop was then tested aboard the NASA-JSC KC135 reduced gravity aircraft. The test loop employed the Sundstrand Two-Phase Thermal Management System (TPTMS) concept which was specially fitted with a clear two-phase return line and condenser cover for flow observation. A two-phase (liquid/vapor) mixture was produced by pumping nearly saturated liquid through an evaporator and adding heat via electric heaters. The quality of the two-phase flow was varied by changing the evaporator heat load. The test loop was operated on the ground before and after the KC135 flight tests to create a one-gravity data base. The ground testing included all the test points run during the reduced gravity testing. Two days of reduced gravity tests aboard the KC135 were performed. During the flight tests, reduced-gravity, one-gravity, and nearly two-gravity accelerations were experienced. Data was taken during the entire flight which provided flow regime and pressure drop data for the three operating conditions. The test results show that two-phase pressure drops and flow regimes can be accurately predicted in zero-gravity.

Hill, D.↗

NaK Plugging Meter Design for the Feasibility Test Loops

The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

Pearson, J. Boise↗

Impact of Fluid Flow Pressure drop on Temperature of Components Controlled by Mechanically Pumped Fluid Loop Thermal Control System

In a typical thermal control system that employs a mechanically pumped fluid loop to control component temperatures, fluid flow pressure drop is minimized to ensure that adequate fluid flow can be provided by the pump. Engineers often are overly concerned about violating a maximum pressure drop, almost treating it as a “wall” that should not be crossed. The true “wall” is the control of the temperatures of the components served by the loop to ensure that their temperatures do not violate their allowed limits. As a case study, for assessing this “constraint,” sensitivity analyses were undertaken to understand if this is truly a major constraint, and to assess the impact of pressure drop exceedance on the controlled components’ temperatures. The flow impedance is varied as a parameter to understand how it affects the controlled components’ temperatures. One key finding was that the temperatures of the controlled components is relatively insensitive to the flow impedance increases. This finding is obviously most relevant to this particular case study; however, this also provides the process and guidance for assessing the performance of other pump/loop combinations in terms of their sensitivity to pressure drop impedances.

Mastropietro, Arthur J.↗

ATLAS LTCS Vertically Challenged System Lessons Learned

Re-planning of LTCS TVAC testing and supporting RTA (Receiver Telescope Assembly) Test Plan and Procedure document preparation. The Laser Thermal Control System (LTCS) is designed to maintain the lasers onboard Advanced Topographic Laser Altimeter System (ATLAS) at their operational temperatures. In order to verify the functionality of the LTCS, a thermal balance test of the thermal hardware was performed. During the first cold start of the LTCS, the Loop Heat Pipe (LHP) was unable to control the laser mass simulators temperature. The control heaters were fully on and the loop temperature remained well below the desired setpoint. Thermal analysis of the loop did not show these results. This unpredicted behavior of the LTCS was brought up to a panel of LHP experts. Based on the testing and a review of all the data, there were multiple diagnostic performed in order to narrow down the cause. The prevailing theory is that gravity is causing oscillating flow within the loop, which artificially increased the control power needs. This resulted in a replan of the LTCS test flow and the addition of a GSE heater to allow vertical operation.

Loop Heat Pipe↗