Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Increasing the upper-limit intensity and temperature range for thermal self-focusing of a laser beam by using plasma density ramp-up

This work is devoted to improving relativistic and ponderomotive thermal self-focusing of the intense laser beam in an underdense plasma. It is shown that the ponderomotive nonlinearity induces a saturation mechanism for thermal self-focusing. Therefore, in addition to the well-known lower-limit critical intensity, there is an upper-limit intensity for thermal self-focusing above which the laser beam starts to experience ponderomotive defocusing. It is indicated that the upper-limit intensity value is dependent on plasma and laser parameters such as the plasma electron temperature, plasma density, and laser spot size. Furthermore, the effect of the upward plasma density ramp profile on the thermal self-focusing is studied. Results show that by using the plasma density ramp-up, the upper-limit intensity increases and the self-focusing temperature range expands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spontaneous focusing of plasma flow in a weak perpendicular magnetic field

Structure formation of high-beta plasma flow in a perpendicular magnetic field is investigated in the ion kinetic regime by a fully kinetic particle-in-cell simulation. We demonstrate that directional plasma flow is spontaneously focused to form a sharp density structure. The primary focusing process comes from field-aligned electron inflow associated with the whistler mode and plasma confinement due to a self-generated magnetic field. The resulting concave magnetic field lines modulate ion gyration to cause a secondary focusing process with significant plasma concentration. Required conditions for these processes are determined by a dimensionless parameter α ≡ β{sub i0}(Δ{sub W}/ρ{sub i0}), where β{sub i0}, Δ{sub W}, and ρ{sub i0} denote the plasma kinetic beta, window size, and ion gyration radius, respectively. The focusing process is apparent for small α, whereas diamagnetic expansion is dominant for large α. This condition describes a transition between diamagnetic cavity formation and the focusing process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flying focus and its application to plasma-based laser amplifiers

Combining a chirped laser pulse with a chromatic lens yields a flying focus—a laser focus that moves dynamically in time. This provides control over the propagation of the peak laser intensity within an extended focal region that can be many times larger than the system’s Rayleigh length. Any velocity is achievable, including backward relative to the laser propagation direction. Previous simulation results have shown that a laser beam with a flying focus can create a counter-propagating ionization wave and subsequently pump a frequency-downshifted laser via the stimulated Raman scattering instability. Compared to a conventional Raman amplification scheme, several advantages were highlighted, including improved temperature control, plasma uniformity, and precursor growth mitigation. Here, we extend those results to demonstrate additional benefits: (1) the flying focus makes it possible for an unseeded Raman amplifier to produce a short, high-intensity beam; and (2) the flying focus minimizes collisional absorption of the pump, facilitating amplifier operation at higher plasma densities. Preliminary experiments have laid the groundwork for a high-performance plasma-based laser amplifier. The focal spot dynamics were initially confirmed at low intensity. It was subsequently demonstrated that ionization waves of arbitrary velocity can be produced at higher intensity. Here, we show a counter-propagating ionization front moving at approximately the speed of light—the optimal result for a Raman amplifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-H-CAMPUS-TeP1-03: Magnetically Focused Proton Irradiation of Small Volume Radiosurgery Targets

Purpose: To investigate the use of magnetic focusing for small volume proton radiosurgery targets using a triplet combination of quadrupole rare earth permanent magnet Halbach cylinder assemblies Methods: Fourteen quadrupole magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into k=3 Halbach cylinders with various field gradients (100 to 250 T/m) were designed and manufactured. Triplet combinations of the magnets were placed on a positioning track on our Gantry 1 treatment table. Unmodulated 127 MeV proton beams with initial diameters of 3 to 20 mm were delivered to a water tank using single-stage scattering. Depth and transverse dose distributions were measured using a PTW PR60020 diode detector and EBT3 film, respectively. This data was compared with unfocused passively collimated beams. Monte Carlo simulations were also performed - both for comparison with experimental data and to further investigate the potential of triplet magnetic focusing. Results: Experimental results using 150 T/m gradient magnets and 15 to 20 mm initial diameter beams show peak to entrance dose ratios that are ∼ 43 to 48 % larger compared with spot size matched 8 mm collimated beams (ie, transverse profile full-widths at 90% maximum dose match within 0.5 mm of focused beams). In addition, the focusing beams were ∼ 3 to 4.4 times more efficient per MU in dose to target delivery. Additional results using different magnet combinations will also be presented. Conclusion: Our results suggest that triplet magnetic focusing could reduce entrance dose and beam number while delivering dose to small (∼≤ 10 mm diameter) radiosurgery targets in less time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however other treatment sites can be also envisioned. This project was sponsored with funding from the Department of Defense (DOD# W81XWH-BAA-10-1).

60 APPLIED LIFE SCIENCES↗

Remote Detection of Uranium Using Self-Focusing Intense Femtosecond Laser Pulses

Optical measurement techniques can address certain important challenges associated with nuclear safety and security. Detection of uranium over long distances presents one such challenge that is difficult to realize with traditional ionizing radiation detection, but may benefit from the use of techniques based on intense femtosecond laser pulses. When a high-power laser pulse propagates in air, it experiences collapse and confinement into filaments over an extended distance even without external focusing. In our experiments, we varied the initial pulse chirp to optimize the emission signal from the laser-produced uranium plasma at an extended distance. While the ablation efficiency of filaments formed by self-focusing is known to be significantly lower when compared to filaments produced by external focusing, we show that filaments formed by self-focusing can still generate luminous spectroscopic signatures of uranium detectable within seconds over a 10-m range. The intensity of uranium emission varies periodically with laser chirp, which is attributed to the interplay among self-focusing, defocusing, and multi-filament fragmentation along the beam propagation axis. Grouping of multi-filaments incident on target is found to be correlated with the uranium emission intensity. The results show promise towards long-range detection, advancing the diagnostics and analytical capabilities in ultrafast laser-based spectroscopy of high-Z elements.

42 ENGINEERING↗

HYBRID simulations of diffraction-limited focusing with Kirkpatrick-Baez mirrors for a next-generation In Situ hard X-ray nanoprobe

Next-generation hard X-ray nanoprobe beamlines such as the In Situ Nanoprobe (ISN) beamline being planned at the Advanced Photon Source aim at providing very high spatial resolution while also enabling very high focused flux, to study complex materials and devices using fast, multidimensional imaging across many length scales. The ISN will use diffractive optics to focus X-rays with a bandpass of ΔE/E = 10 –4 into a focal spot of 20 nm or below. Reflective optics in Kirkpatrick-Baez geometry will be used to focus X-rays with a bandpass as large as ΔE/E = 10 –2 into a focal spot of 50 nm. Diffraction-limited focusing with reflective optics is achieved by spatial filtering and use of a very long, vertically focusing mirror. Furthermore, to quantify the performance of the ISN beamline, we have simulated the propagation of both partially and fully coherent wavefronts from the undulator source, through the ISN beamline and into the mirror-based focal spot. Simulations were carried out using the recently developed software “HYBRID.”

43 PARTICLE ACCELERATORS↗

Treatment of Parkinson's disease in rats by Nrf2 transfection using MRI-guided focused ultrasound delivery of nanomicrobubbles

Parkinson's disease (PD) is a very common neurological disorder. However, effective therapy is lacking. Although the blood-brain-barrier (BBB) protects the brain, it prevents the delivery of about 90% of drugs and nucleotides into the brain, thereby hindering the development of gene therapy for PD. Magnetic resonance imaging (MRI)-guided focused ultrasound delivery of microbubbles enhances the delivery of gene therapy vectors across the BBB and improves transfection efficiency. In the present study, we delivered nuclear factor E2-related factor 2 (Nrf2, NFE2L2) contained in nanomicrobubbles into the substantia nigra of PD rats by MRI-guided focused ultrasound, and we examined the effect of Nrf2 over-expression in this animal model of PD. The rat model of PD was established by injecting 6-OHDA in the right substantia nigra stereotactically. Plasmids (pDC315 or pDC315/Nrf2) were loaded onto nanomicrobubbles, and then injected through the tail vein with the assistance of MRI-guided focused ultrasound. MRI-guided focused ultrasound delivery of nanomicrobubbles increased gene transfection efficiency. Furthermore, Nrf2 gene transfection reduced reactive oxygen species levels, thereby protecting neurons in the target region. - Highlights: • MRI-guided focused ultrasound enhances gene transfection into the brain of rats. • Increased Nrf2 expression protects neurons in the rat model of PD. • Nrf2 protects neurons in PD by inhibiting ROS production.

60 APPLIED LIFE SCIENCES↗

Beam focusing and consequences for Doppler backscattering measurements

The phenomenon of focusing of microwave beams in a plasma near a turning-point caustic is discussed by exploiting the analytical solution to the Gaussian beam-tracing equations in the two-dimensional (2-D) linear-layer problem. The location of maximum beam focusing and the beam width at that location are studied in terms of the beam initial conditions. This focusing must be taken into account to interpret Doppler backscattering (DBS) measurements. We find that the filter function that characterises the scattering intensity contribution along the beam path through the plasma is inversely proportional to the beam width, predicting enhanced scattering from the beam focusing region. We show that the DBS signal enhancement for decreasing incident angles between the beam path and the density gradient is due to beam focusing and not due to forward scattering, as was originally proposed by (Gusakov et al., (Plasma Phys. Contr. Fusion, vol. 56, 2014, p. 0250092014, 2017); Plasma Phys. Rep. vol. 43(6), 2017, pp. 605–613). The analytic beam model is used to predict the measurement of the k y density-fluctuation wavenumber power spectrum via DBS, showing that, in an NSTX-inspired example, the spectral exponent of the turbulent, intermediate-to-high k y density-fluctuation spectrum might be quantitatively measurable via DBS, but not the spectral peak corresponding to the driving scale of the turbulent cascade.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flying focus with arbitrary directionality for spatiotemporal control of laser intensity

Flying focus techniques produce laser pulses whose focal points travel at arbitrary, controllable velocities. While this flexibility can enhance a broad range of laser-based applications, existing techniques constrain the motion of the focal point to the propagation direction of the pulse. Here, we introduce a flying focus configuration that decouples the motion of the focus from the propagation direction. Here, a chirped laser pulse focused and diffracted by a diffractive lens and grating creates a focal point that can move both along and transverse to the propagation direction. The focal length of the lens, grating period, and chirp can be tuned to control the direction and velocity of the focus. Simulations demonstrate this control for a holographic configuration suited to high-power pulses, in which two off-axis pump beams with different focal lengths encode the equivalent phase of a chromatic lens and grating in a gas or plasma. For low-power pulses, conventional solid-state or adaptive optics can be used instead. Multi-dimensional control over the focal trajectory enables new configurations for applications, including laser wakefield acceleration of ions, nonlinear Thomson scattering, and surface-plasmon emission of THz radiation.

Classical optics↗

In-Situ Nanoscale Focusing of Extreme Ultraviolet Solid-State High Harmonics

Extreme ultraviolet light delivering radiation with a wavelength shorter than approximately 100 nm is now available from solid-state sources. However, despite exceptional progress, efficient focusing of extreme ultraviolet photons to their ultimate diffraction limit remains a formidable challenge because of the precision of the focusing by curved, optical surfaces. Here we integrate coherent short-wavelength high-order harmonics from a MgO crystal, with a high-numerical-aperture, nanostructured, focusing element etched onto the surface of the crystal itself. We focus extreme ultraviolet light, seventh harmonic of an 800-nm laser, with a zone plate of numerical aperture 0.35, down to a waist radius of 150 nm, with 18% focusing efficiency. The estimated intensity approaches 10 7 W/cm 2 . Future developments may demonstrate nanoscale laser ablation and miniaturization of extreme ultraviolet coherent sources on a chip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pink-beam focusing with a one-dimensional compound refractive lens

The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X-ray beam to spatially overlap with an 80 µm-high low-density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm –2 was calculated. A CRL is chromatic so it does not efficiently focus X-rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment. A two-chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X-ray filter. As a result, a method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cross-polarization systematics due to Mizuguchi-Dragone condition breaking by a continuously rotating half-wave plate at prime focus in the Huan Tran telescope

Polarization modulation using a continuously rotating half-wave plate (HWP) is a promising technique to reduce both low-frequency noise and instrumental systematics for Cosmic Microwave Background (CMB) polarization measurements targeting in ationary B-modes. Although a HWP is best placed sky-side of the telescope optics in order to minimize systematics, >0.5 meter aperture class telescopes must put the HWP elsewhere in the optics chain due to current fabrication limitations in the available HWP size. Polarbear is a ground-based CMB experiment installed on the 2.5m aperture off-axis Gregorian-Dragone type Huan Tran Telescope (HTT) designed to satisfy the Mizuguchi-Dragone condition. Polarbear-2 is a receiver that will be installed on a second HTT in 2018. Polarbear-2 is designed to have a larger field-of-view (FOV) and vastly increased sensitivity to the polarized CMB compared to Polarbear. From the third season of observations, Polarbear has installed a continuously rotating HWP at the spatially localized focus plane between the HTT primary and secondary re ectors which is an optimal location for minimizing the HWP diameter. The HWP's polarization angle re ection with respect to its birefringent axis will theoretically break the Mizuguchi-Dragone condition when placed between the two reflectors and increase cross-polarization systematics. In this study, we analyze how the Mizuguchi-Dragone condition is violated due to a HWP at this location. We then estimate the crosspolarization systematics of the HTT using physical optics simulations. We model an ideal HWP at various angles to estimate the effects of demodulation. We evaluate the increased cross-polarization as the Stokes Q-U mixing term using the Mueller Matrix formalism. It is calculated that this term creates a varying dipole beam pattern whose amplitude ranges from 1% at the center to 10% at the edge FOV pixels for Polarbear and potentially up to 20% for Polarbear-2. We also estimate the leakage of the E-mode into the B-mode angular power spectrum measurements due to this cross-polarization. We show that the cross-polarization systematic error leakage is sufficiently lower than the Polarbear-2 statistical uncertainty thanks to mitigations such as focal plane averaging and sky rotation. Currently for Polarbear-2 we are planning to place the HWP at Gregorian focus, but keeping the HWP at prime focus as a back-up solution in case that there are unforeseen telescope spatial and HWP material size constraints. Through this study we find that even though a HWP between the two reflectors will violate the Mizuguchi-Dragone condition, this HWP at prime focus will still have sufficiently low cross-polarization for Polarbear-2. The prime focus HWP is a potential configuration that can be applied to similar off-axis Gregorian-Dragone telescopes in order to minimize the required HWP diameter.

Takakura, Satoru↗

WE-D-17A-04: Magnetically Focused Proton Irradiation of Small Volume Targets

Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment nozzle that incorporates similar focusing magnets. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

60 APPLIED LIFE SCIENCES↗

Rapidly tunable ultrabroadband flying focus using adaptive optics and an axiparabola

A programmable ultrabroadband flying focus was produced using adaptive optics and an axiparabola with a continuous wave superluminescent diode. A deformable mirror and spatial light modulator were used to add a programmable amount of radial group delay, and an axiparabola was used to create an extended focus by imparting spherical aberration. Three different flying focus trajectories were measured using spectral interferometry, two with uniform velocity and one with an accelerating velocity. Here, the temporal response function width of the flying focus optics alone was calculated to be 52 ± 6 fs, and the focal spot size was measured to be (1.2 ± 0.1) × larger than the diffraction-limited spot size through the extended focus.

Markland, H. S. [University of Rochester, NY (Unit↗

Final Focus Solenoid Design Considerations

Radiography utilizing intense relativistic electron beams requires a final focus magnet to produce a small beam spot on the x-ray conversion target. A solenoid magnet is generally used for the final focus magnet. This note addresses design considerations of the final focus solenoid that impact the spot size. The spot size on target is a function of the beam size entering the final focus magnet, the beam emittance and energy spread and spherical aberration inherent in a solenoid magnet. The present final focus solenoid designs for both Axis 1 and Axis 2 of the DARHT facility are evaluated. A new design is proposed for both Axis 1 and Axis 2.

43 PARTICLE ACCELERATORS↗

The Dark Energy Spectrographic Instrument (DESI) Guide-Focus Assembly

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. Our CRADA with the The Institut de Física d’Altes Energies (IFAE) in Barcelona (Spain) involved both research planning for eventual observing on the DESI telescope; and in providing hardware jointly designed by LBNL and IFAE; ten guide and focus sensor systems (GFAs) that either provide feedback to the Mayall telescope tracking system or provide focus position information to the DESI corrector hexapod. The key major goals of this CRADA were achieved.For survey planning, Drs. Fernandez, Fosalba, Garcia-Bellido, and Gaztañaga were all important contributors to the working groups to which they were assigned. Their application of redshift techniques, development of simulations to support target selection, exploration of the use of alternative observables to extract cosmological information like AP and void statistics, and the use of PAU data to assist in the optimization of targeting selections have been vital in the early planning for targets during commissioning. The major role in the project involved Drs. Castander, Miquel, Padilla, and Sànchez. They were all directly involved with the development of the Guide-Focus Assembly (GFA) hardware, software and filter validation. In order to accomplish the goals of the DESI Project, the Mayall telescope must track DESI targeted galaxies for up to 15 minutes and the DESI corrector must be repositioned on its hexapod system for different telescope orientations. The guide and focus assemblies (GFA) provide in this information. There are ten GFA modules on the focal plane, six providing tracking information and four providing focus information. A common GFA design supports both functions by a simple switching of its operating mode. IFAE designed, fabricated, tested and delivered twelve GFAs. Once received at LBNL, the GFAs were integrated with the focal plane. This was an iterative process as the GFA’s were delivered as they were made. Our working relationship with the IFAE scientists and engineers was remarkable given the distance and time zone issues. The GFAs have performed extremely well during the commissioning phase of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗