Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FATIGUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High temperature tension-compression fatigue behavior of a tungsten copper composite

The high temperature fatigue of a (O)12 tungsten fiber reinforced copper matrix composite was investigated. Specimens having fiber volume percentages of 10 and 36 were fatigued under fully-reversed, strain-controlled conditions at both 260 and 560 C. The fatigue life was found to be independent of fiber volume fraction because fatigue damage preferentially occurred in the matrix. Also, the composite fatigue lives were shorter at 560 C as compared to 260 C due to changes in mode of matrix failure. On a total strain basis, the fatigue life of the composite at 560 C was the same as the life of unreinforced copper, indicating that the presence of the fibers did not degrade the fatigue resistance of the copper matrix in this composite system. Comparison of strain-controlled fatigue data to previously-generated load-controlled data revealed that the strain-controlled fatigue lives were longer because of mean strain and mean stress effects.

Verrilli, Michael J.↗

Fatigue Strength and Related Characteristics of Aircraft Joints I : Comparison of Spot-Weld and Rivet Patterns in 24s-t Alclad and 75s-t Alclad

Report contains detailed results of a number of fatigue tests on spot-welded joints in aluminum alloys. The tests described include: (1) fatigue tests on spot-welded lap joints in sheets of unequal thickness of alclad 24s-t. These tests indicate that the fatigue strength of a spot-welded joint in sheets of two different gages is slightly higher than that of a similar joint in two sheets of the thinner gage but definitely lower than that of a similar joint in two sheets of the thicker gage. (2) Fatigue tests on spot-welded alclad 75s-t spot-welded lap-joint specimens of alclad 75s-t were not any stronger in fatigue than similar specimens of alclad 24s-t. (3) Fatigue tests on lap-joint specimens spot -welded after various surface preparations--these included ac welding wire-brushed surfaces, dc welding wire-brushed surfaces, and dc welding chemically cleaned surfaces. While the ac welds were strongest statically, the dc welds on wire-brushed surfaces were strongest in fatigue. Specimens prepared in this way were very nearly as strong as the best riveted specimens tested for comparison. (4) Fatigue tests on specimens spot-welded with varying voltage so as to include a wide range of static spot-weld strengths. The fatigue strengths were in the same order as the static strengths but showed less range. (author)

Russell, H W↗

Isothermal fatigue mechanisms in Ti-based metal matrix composites

Stress-controlled isothermal fatigue experiments were performed at room temperature (RT) and 548 C (in argon) on (0)8 SCS6/Ti 15-3 metal matrix composites (MMC's) with 15 and 41 volume percent SCS6 (SiC) fibers. The primary objectives were to evaluate the mechanical responses, and to obtain a clear understanding of the damage mechanisms leading to failure of the MMC's. The mechanical data indicated that strain ranges attained fairly constant values in the stress-controlled experiments at both RT and 538 C, and remained so for more than 85 percent of life. The fatigue data for MMC's with different volume fraction fibers showed that MMC life was controlled by the imposed strain range rather than the stress range. At RT, and at low and intermediate strain ranges, the dominant fatigue mechanism was matrix fatigue, and this was confirmed metallurgically from fractographic evidence as well as from observations of channel type dislocation structures in the matrix of fatigued MMC specimens. Reaction-zone cracks acted as important crack initiating sites at RT, with their role being to facilitate slip band formation and consequent matrix crack initiation through classical fatigue mechanisms. MMC life agreed with matrix life at the lower strain ranges, but was smaller than matrix life at higher strain ranges. Unlike the case of monotonic deformation, debonding damage was another major damage mechanism during fatigue at RT, and it increased for higher strain ranges. At high strain ranges at RT, fractography and metallography showed an absence of matrix cracks, but long lengths of debonds in the outer layers of the SCS6 fibers. Such debonding and consequent rubbing during fatigue is believed to have caused fiber damage and their failure at high strain ranges. Thus, whereas life was matrix dominated at low and intermediate strain ranges, it was fiber dominated at high strain ranges. At 538 C, the mean stain constantly increased (ratchetting) with the number of cycles. At high strain ranges, such ratchetting led to overload failure of the fibers, and debonding of the type at RT was very small. At intermediate strain ranges, fractography showed large areas of matrix cracks. However, in spite of this matrix dominated mechanism, the MMC life at elevated temperatures was significantly less than the matrix fatigue life at all strain ranges. The reason for this difference is still unclear, although metallographic and fractographic evidences suggest that internal crack initiation sites at Mo-ribbons and reaction-zone cracks may have played a critical role, with the former tending to dominate.

Majumdar, Bhaskar S.↗

A probabilistic fatigue analysis of multiple site damage

The variability in initial crack size and fatigue crack growth is incorporated in a probabilistic model that is used to predict the fatigue lives for unstiffened aluminum alloy panels containing multiple site damage (MSD). The uncertainty of the damage in the MSD panel is represented by a distribution of fatigue crack lengths that are analytically derived from equivalent initial flaw sizes. The variability in fatigue crack growth rate is characterized by stochastic descriptions of crack growth parameters for a modified Paris crack growth law. A Monte-Carlo simulation explicitly describes the MSD panel by randomly selecting values from the stochastic variables and then grows the MSD cracks with a deterministic fatigue model until the panel fails. Different simulations investigate the influences of the fatigue variability on the distributions of remaining fatigue lives. Six cases that consider fixed and variable conditions of initial crack size and fatigue crack growth rate are examined. The crack size distribution exhibited a dominant effect on the remaining fatigue life distribution, and the variable crack growth rate exhibited a lesser effect on the distribution. In addition, the probabilistic model predicted that only a small percentage of the life remains after a lead crack develops in the MSD panel.

Rohrbaugh, S. M.↗

Transverse Tension Fatigue Life Characterization Through Flexure Testing of Composite Materials

The transverse tension fatigue life of S2/8552 glass-epoxy and IM7/8552 carbon-epoxy was characterized using flexure tests of 90-degree laminates loaded in 3-point and 4-point bending. The influence of specimen polishing and specimen configuration on transverse tension fatigue life was examined using the glass-epoxy laminates. Results showed that 90-degree bend specimens with polished machined edges and polished tension-side surfaces, where bending failures where observed, had lower fatigue lives than unpolished specimens when cyclically loaded at equal stress levels. The influence of specimen thickness and the utility of a Weibull scaling law was examined using the carbon-epoxy laminates. The influence of test frequency on fatigue results was also documented for the 4-point bending configuration. A Weibull scaling law was used to predict the 4-point bending fatigue lives from the 3-point bending curve fit and vice-versa. Scaling was performed based on maximum cyclic stress level as well as fatigue life. The scaling laws based on stress level shifted the curve fit S-N characterizations in the desired direction, however, the magnitude of the shift was not adequate to accurately predict the fatigue lives. Furthermore, the scaling law based on fatigue life shifted the curve fit S-N characterizations in the opposite direction from measured values. Therefore, these scaling laws were not adequate for obtaining accurate predictions of the transverse tension fatigue lives.

OBrien, T. Kevin↗

Case Studies of Fatigue Life Improvement Using Low Plasticity Burnishing in Gas Turbine Engine Applications

Surface enhancement technologies such as shot peening, laser shock peening (LSP), and low plasticity burnishing (LPB) can provide substantial fatigue life improvement. However, to be effective, the compressive residual stresses that increase fatigue strength must be retained in service. For successful integration into turbine design, the process must be affordable and compatible with the manufacturing environment. LPB provides thermally stable compression of comparable magnitude and even greater depth than other methods, and can be performed in conventional machine shop environments on CNC machine tools. LPB provides a means to extend the fatigue lives of both new and legacy aircraft engines and ground-based turbines. Improving fatigue performance by introducing deep stable layers of compressive residual stress avoids the generally cost prohibitive alternative of modifying either material or design. The X-ray diffraction based background studies of thermal and mechanical stability of surface enhancement techniques are briefly reviewed, demonstrating the importance of minimizing cold work. The LPB process, tooling, and control systems are described. An overview of current research programs conducted for engine OEMs and the military to apply LPB to a variety of engine and aging aircraft components are presented. Fatigue performance and residual stress data developed to date for several case studies are presented including: * The effect of LPB on the fatigue performance of the nickel based super alloy IN718, showing fatigue benefit of thermal stability at engine temperatures. * An order of magnitude improvement in damage tolerance of LPB processed Ti-6-4 fan blade leading edges. * Elimination of the fretting fatigue debit for Ti-6-4 with prior LPB. * Corrosion fatigue mitigation with LPB in Carpenter 450 steel. *Damage tolerance improvement in 17-4PH steel. Where appropriate, the performance of LPB is compared to conventional shot peening after exposure to engine operating temperatures.

Prevey, Paul S.↗

Piezoelectric Bolt Breakers and Bolt Fatigue Testers

A proposed family of devices for inducing fatigue in bolts in order to break the bolts would incorporate piezoelectric actuators into resonant fixtures as in ultrasonic/ sonic drills/corers and similar devices described in numerous prior NASA Tech Briefs articles. These devices were originally intended primarily for use as safer, more-reliable, more-versatile alternatives to explosive bolts heretofore used to fasten spacecraft structures that must subsequently be separated from each other quickly on command during flight. On Earth, these devices could be used for accelerated fatigue testing of bolts. Fatigue theory suggests that a bolt subjected to both a constant-amplitude dynamic (that is, oscillatory) stress and a static tensile stress below the ultimate strength of the bolt material will fail faster than will a bolt subjected to only the dynamic stress. This suggestion would be applied in a device of the proposed type. The device would be designed so that the device and the bolt to be fatigue-tested or broken would be integral parts of an assembly (see figure). The static tension in the tightened bolt would apply not only the clamping force to hold the joined structures (if any) together but also the compression necessary for proper operation of the piezoelectric actuators as parts of a resonant structural assembly. The constant-amplitude dynamic stress would be applied to the bolt by driving the piezoelectric actuators with a sinusoidal voltage at the resonance frequency of longitudinal vibration of the assembly. The amplitude of the excitation would be made large enough so that the vibration would induce fatigue in the bolt within an acceptably short time. In the spacecraft applications or in similar terrestrial structural-separation applications, devices of the proposed type would offer several advantages over explosive bolts: Unlike explosive bolts, the proposed devices would be reusable, could be tested before final use, and would not be subject to catastrophic misfire. In fatigue-testing applications, devices of the proposed type would offer advantages of compactness and low cost, relative to conventional fatigue- testing apparatuses. In both structural- separation and fatigue-testing applications, bolts to be broken or tested could be instrumented with additional ultrasonic transducers for monitoring of pertinent physical properties and of fatigue failure processes.

Sherrit, Stewart↗

Assessment of irradiation embrittlement effect on fatigue life of a pressurized-water reactor pressure vessel using the fracture toughness master curve approach

The reactor pressure vessel (RPV) is a critical structural component in pressurized-water reactors, and it is designed to withstand extreme conditions, such as high pressures, elevated temperatures, and prolonged radiation exposure. Ensuring RPV integrity is essential for the safe and reliable long-term operation of nuclear power plants, especially as aging mechanisms such as fatigue and irradiation embrittlement pose increased risks. Fatigue, caused by cyclic thermal and mechanical loading, can lead to crack initiation in localized high-stress regions. Simultaneously, neutron irradiation, particularly in the beltline region, progressively reduces fracture toughness, increasing susceptibility to brittle fracture. These combined effects of fatigue and irradiation embrittlement potentially impact the RPV structural integrity, necessitating fitness-for-service assessments. This study applies the fracture toughness master curve approach to evaluate the impact of irradiation embrittlement on RPV fatigue life. A coupled thermo-mechanical stress analysis identifies critical stress locations under normal service transients, pinpointing regions most vulnerable to fatigue crack initiation and growth. Stress intensity factors for postulated flaws at these locations are calculated, enabling an assessment of fatigue life under irradiated and unirradiated conditions. The results indicate that neutron irradiation embrittlement accelerates the conditions in which a critical crack can form and lead to failure, particularly at lower temperatures. The failure occurs where reduced fracture toughness limits the material’s resistance to crack growth. Axial cracks at nozzle corners are the most life limiting without irradiation, while circumferential cracks demonstrate longer fatigue lives. The findings highlight the importance of incorporating irradiation effects into fatigue life predictions to ensure the long-term structural integrity of RPVs.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Flexural Fatigue Testing and Qualification of Hybrid PAN-pitch Composite Materials with High Through-Thickness Thermal Conductivity

Carbon-fiber-reinforced polymers (CFRPs) considered for motor components within future electric vertical takeoff and landing (eVTOL) vehicles require not only a high strength-to-weight ratio but also a high through-thickness thermal conductivity (TC) to dissipate heat. Previously, CFRPs incorporating pitch CF interleaves demonstrated an increased through-thickness TC relative to the baseline composite, but the effect on flexural fatigue life was not evaluated. For this work, T700S/TC275–1 braided carbon fiber/epoxy prepreg baseline (no interleave), YSH–60A pitch interleave, and YS–80A pitch interleave configurations were tested for fatigue life. A combination of ASTM International Standards D7264 and D3479 were used to develop a reliable testing method. An Instron® (Illinois Tool Works Inc.) 8501 servohydraulic system with a fatigue test fixture was set up with a 16:1 span:thickness ratio, load ratio R set to 0.1, and frequency of 4 Hz. High-cycle fatigue testing was completed, and it was found that YSH–60A interleave performed slightly better than YS–80A below 100,000 cycles but showed no differences above 100,000 cycles. In all cases, the baseline CFRP had superior fatigue life performance both in terms of stress handled and total cycles to failure. These fatigue testing data will inform future use of hybrid CFRP materials by highlighting the tradeoff between increased through-thickness TC and fatigue life. Testing guidelines, equipment, and parameters for static and fatigue tests were successfully outlined for CFRPs.

composites↗

Fatigue failure of metal components as a factor in civil aircraft accidents

A review of records maintained by the National Transportation Safety Board showed that 16,054 civil aviation accidents occurred in the United States during the 3-year period ending December 31, 1969. Material failure was an important factor in the cause of 942 of these accidents. Fatigue was identified as the mode of the material failures associated with the cause of 155 accidents and in many other accidents the records indicated that fatigue failures might have been involved. There were 27 fatal accidents and 157 fatalities in accidents in which fatigue failures of metal components were definitely identified. Fatigue failures associated with accidents occurred most frequently in landing-gear components, followed in order by powerplant, propeller, and structural components in fixed-wing aircraft and tail-rotor and main-rotor components in rotorcraft. In a study of 230 laboratory reports on failed components associated with the cause of accidents, fatigue was identified as the mode of failure in more than 60 percent of the failed components. The most frequently identified cause of fatigue, as well as most other types of material failures, was improper maintenance (including inadequate inspection). Fabrication defects, design deficiencies, defective material, and abnormal service damage also caused many fatigue failures. Four case histories of major accidents are included in the paper as illustrations of some of the factors invovled in fatigue failures of aircraft components.

Holshouser, W. L.↗

Effect of lubricant extreme pressure additives on rolling element fatigue life

The effects of surface active additives on rolling-element fatigue life were investigated with the five-ball fatigue tester at conditions where classical subsurface initiated rolling-element fatigue is the sole mode of failure. Test balls of AISI 52100, AISI M-50, and AISI 1018 were run with an acid-treated white oil containing either 2.5 percent sulfurized terpene, 1 percent didodecyl phosphite, or 5 percent chlorinated wax. In general, it was found that the influence of surface active additives was detrimental to rolling-element fatigue life. The chlorinated-wax additive significantly reduced fatigue life by a factor of 7. The base oil with the 2.5 percent sulfurized-terpene additive can reduce fatigue life by as much as 50 percent. No statistical change in fatigue life occurred with the base oil having the 1 percent didodecyl-phosphite additive. The additives used with the base oil did not change the ranking of the bearing steels where rolling-element fatigue life was of subsurface origin.

Parker, R. J.↗

A study of fatigue and fracture in 7075-T6 aluminum alloy in vacuum and air environments

Axial load fatigue life, fatigue-crack propagation, and fracture toughness experiments were conducted on sheet specimens made of 7075-T6 aluminum alloy. These experiments were conducted at pressures ranging from atmospheric to 5 x 10 to the minus 8th torr. Analysis of the results from the fatigue life experiments indicated that for a given stress level, lower air pressures produced longer fatigue lives. At a pressure of 5 x 10 to the minus 8th torr fatigue lives were 15 or more times as long as at atmospheric pressure. Analysis of the results from the fatigue crack propagation experiments indicated that for small stress intensity factor ranges the fatigue crack propagation rates were up to twice as high at atmospheric pressure as in vacuum. The fracture toughness of 7075-T6 was unaffected by the vacuum environment. Fractographic examination showed that specimens tested in both vacuum and air developed fatigue striations. Considerably more striations developed on specimens tested at atmospheric pressure, however.

Hudson, C. M.↗

Influence of fretting on flexural fatigue of 304 stainless steel and mild steel

Fretting fatigue experiments conducted on 304 stainless steel using a flexural fatigue test arrangement with bolted on fretting pads demonstrated that fatigue life is reduced by at least a factor of 10 in the 265 to 334 MPa (38,500 - to 48,500 psi) nominal flexural fatigue stress range. In addition, experiments in which the fretting pads were removed after selected numbers of cycles, followed by continued flexural fatigue without fretting show that continued fretting beyond 50,000 cycles does not significantly further reduce fatigue life of 304 stainless steel at 317 MPa (46,000 psi). Microscopic examination of the fretted contact areas revealed fracture initiation sites as well as numerous cracks that did not propagate to failure. Flexural fretting fatigue experiments performed on mild steel showed an insensitivity of fatigue life to the incidence of fretting under flexural stress conditions of from 162 to 217 MPa (23,500 to 31,500 psi).

Bill, R. C.↗

Corrosion fatigue of high strength fastener materials in seawater

Environmental effects which significantly reduce the fatigue life of metals are discussed. Corrosion fatigue is a major concern in the engineering application of high strength fasteners in marine environments. The corrosion fatigue failure of an AISI 41L4O high strength steel blade to hub attachment bolt at the MOD-OA 200 kW wind turbine generator was investigated. The reduction of fatigue strength of AISI 41L4O in marine environments and to obtain similar corrosion fatigue data for candidate replacement materials was studied. The AISI 4140, PH 13-8Mo stainless steel, alloy 718 and alloy MP-35N were tested in axial fatigue at a frequency of 20 Hz in dry air and natural seawater. The fatigue data are fitted by regression equations to allow determination of fatigue strength for a given number of cycles to failure.

Tipton, D. G.↗

Low-cycle thermal fatigue

A state-of-the-art review is presented of the field of thermal fatigue. Following a brief historical review, the concept is developed that thermal fatigue can be viewed as processes of unbalanced deformation and cracking. The unbalances refer to dissimilar mechanisms occurring in opposing halves of thermal fatigue loading and unloading cycles. Extensive data summaries are presented and results are interpreted in terms of the unbalanced processes involved. Both crack initiation and crack propagation results are summarized. Testing techniques are reviewed, and considerable discussion is given to a technique for thermal fatigue simulation, known as the bithermal fatigue test. Attention is given to the use of isothermal life prediction methods for the prediction of thermal fatigue lives. Shortcomings of isothermally-based life prediction methods are pointed out. Several examples of analyses and thermal fatigue life predictions of high technology structural components are presented. Finally, numerous dos and don'ts relative to design against thermal fatigue are presented.

Halford, G. R.↗

Creep-fatigue interaction of titanium alloy Ti-6Al-2Cb-1Ta-0.8Mo at room temperature

The present investigation is concerned with the mutual influence of creep and fatigue in the case of Ti-6211, which represents a new weldable, stress-corrosion resistant alloy. Attention is given to the effect of creep on fatigue, the effect of fatigue on creep, and microstructural studies. It is found that prior creep in the amounts investigated, from 0.2 percent to 2.7 percent, is beneficial to low-cycle fatigue life. Hold time at peak strain is found to be beneficial to low-cycle fatigue life. Hold time at constant stress has no effect on low-cycle fatigue when specimens are cycled only once between hold times; but increasing fatigue loading for 50 or more cycles between hold times can prolong the fatigue life. There is an acceleration of creep by cyclic loading when comparison of cyclic and static creep is based on mean stress.

Chu, H. P.↗

Bithermal fatigue of a nickel-base superalloy single crystal

The thermomechanical fatigue behavior of a nickel-base superalloy single crystal was investigated using a bithermal test technique. The bithermal fatigue test was used as a simple alternative to the more complex thermomechanical fatigue test. Both in-phase and out-of-phase bithermal tests were performed on (100)-oriented coated and bare Rene N4 single crystals. In out-of-plane bithermal tests, the tensile and compressive halves of the cycle were applied isothermally at 760 and 982 C, respectively, while for the in-phase bithermal tests the temperature-loading sequence was reversed. The bithermal fatigue lives of bare specimens were shorter than the isothermal fatigue lives at either temperature extreme when compared on an inelastic strain basis. Both in-phase and out-of-phase bithermal fatigue life curves converged in the large strain regime and diverged in the small strain regime, out-of-phase resulting in the shortest lives. The coating had no effect on life for specimens cycled in-phase; however, the coating was detrimental for isothermal fatigue at 760 C and for out-of-phase fatigue under large strains.

Verrilli, Michael J.↗

Isothermal and nonisothermal fatigue behavior of a metal matrix composite

The isothermal and nonisothermal fatigue resistance of a metal matrix composite (MMC) consisting of Ti-15V-3Cr-3Al-3Sn (Ti-15-3) matrix reinforced by 33 vol pct continuous SiC fibers was investigated. The fibers were nominally oriented parallel to the specimen axis. Isothermal fatigue tests were performed in air at 300 and 550 C. The MMC had good isothermal fatigue resistance at low cyclic stress, with fatigue cracks initiating from fiber-matrix interfaces and foil laminations. At high cyclic stresses, stress relaxation in the matrix reduced isothermal composite fatigue resistance at 550 C. Nonisothermal fatigue loading substantially degraded composite fatigue resistnce. This degradation was produced by a thermomechanical fatigue damage mechanism associated with the fiber-matrix interfaces.

Gabb, T. P.↗