Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAST NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A laser-induced repetitive fast neutron source applied for gold activation analysis

A laser-induced repetitively operated fast neutron source was developed for applications in laser-driven nuclear physics research. The developed neutron source, which has a neutron yield of approximately 4 Multiplication-Sign 10{sup 5} n/pulse and can be operated up to a pulse repetition rate of 10 Hz, was applied for a gold activation analysis. Relatively strong delayed gamma spectra of the activated gold were measured at 333 keV and 355 keV, and proved the possibility of the neutron source for activation analyses. In addition, the nuclear reactions responsible for the measured gamma spectra of gold were elucidated by the 14 MeV fast neutrons resulting from the D(t,n)He{sup 4} nuclear reaction, for which the required tritium originated from the primary fusion reaction, D(d,p)T{sup 3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of Properties of {sup 89}Y Levels with Reactor Fast Neutrons

By employing a beam of reactor fast neutrons, the spectrum of gamma rays up to an energy of 4.6MeV and their angular distributions with respect to the neutron-beamaxis aremeasured in the reaction {sup 89}Y(n, n'γ). The multipolarities and multipole-mixture parameters for 34 gamma transitions and the spin–parities J{sup π} of states excited in this reaction are determined. The lifetimes of the lowest 32 levels of 89Y were measured by the Doppler shift attenuation method, and the reduced probabilities for the respective gamma transitions were calculated. Levels of the K{sup π} = +5/2{sup +} and K{sup π} = −7/2{sup +} bands associated with, respectively, prolate and oblate deformation shapes are found in {sup 89}Y at low excitation energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of MSNDs for Fast-Neutron Detection and the TREAT Hodoscope

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. A key feature of the TREAT reactor core is an open, horizontal channel that allows line-of-sight viewing of test specimens using various instrumentation during steady-state and transient operation. This instrumentation includes the hodoscope, which consists of over 300 steel-collimated channels coupled to Hornyak buttons (and other detectors) for detection of fast neutrons emitted from fission of the test specimen. Posterior analysis can be used to reconstruct fuel motion and other properties from the collimated channel signals. A large-scale effort is underway to develop next generation instrumentation for transient testing at TREAT (and, potentially, other facilities). Work at KSU specifically aims to provide improved detection systems for hodoscope applications. It was initially proposed to adapt KSU-developed Microstructured Semiconductor Neutron Detectors (MSNDs) for use as fast-neutron detectors. The current generation of MSNDs is designed for thermal-neutron detection based on {sup 6}Li and can achieve intrinsic efficiencies nearing 30% owing to the large (n, t) cross section of {sup 6}Li and clever optimization of the geometry. In order to evaluate MSNDs for fast-neutron detection, two approaches were considered: (1) use of a hydrogenous material to thermalize neutrons to exploit the intrinsic efficiencies of current MSNDs, and (2) substitution of a fast-sensitive reactant for {sup 6}Li. The former approach is attractive because it makes use of proven, off-the-shelf technology and leads to reasonable time resolution and efficiency. Unfortunately, use of thermalization leads to prohibitive degradation of spatial resolution. The second approach will require further experimental efforts, but scoping analyses suggest {sup 235}U- or {sup 237}Th-loaded MSNDs may achieve sufficient efficiencies. The rest of this summary examines these issues in more detail. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Versatile D-T Neutron-Generation System for Fast-Neutron Research and Education

In order to stimulate new cutting-edge research and create novel educational tools at the Pennsylvania State University (PSU), the PIs of the project acquired a versatile 14-MeV D-T neutron-generation system. Relatively recent advancements at Lawrence Berkeley National Laboratory (LBNL) have led to the development of high-neutron-output D-T neutron generators. The resulting technology was subsequently licensed to Adelphi Technology, Inc. and 14-MeV D-T neutron-generation systems are currently available with neutron yields up to 10 10 n/sec. Such neutron output has been available previously; however, the existing D-T generators were traditionally million-dollar systems (an example is D711 from Thermo Scientific), thus beyond reach for many users. The Adelphi neutron generators, on the other hand, now provide access to high neutron outputs for a reasonable price. More importantly, the expected lifetime of the D-T system’s tubes is at least 2,000 hours; a factor of two better when compared to D711, with comparable generator-tube replacement cost. Adelphi Technology, the manufacturer of the dual D-T neutron generation system, delivered one 10 8 neutrons/second and one 10 10 neutrons/second D-T generator with two separate control units to PSU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive and Active Fast-Neutron Imaging in Support of Advanced Fuel Cycle Initiative Safeguards Campaign

Results from safeguards-related passive and active coded-aperture fast-neutron imaging measurements of plutonium and highly enriched uranium (HEU) material configurations performed at Idaho National Laboratory s Zero Power Physics Reactor facility are presented. The imaging measurements indicate that it is feasible to use fast neutron imaging in a variety of safeguards-related tasks, such as monitoring storage, evaluating holdup deposits in situ, or identifying individual leached hulls still containing fuel. The present work also presents the first demonstration of imaging of differential die away fast neutrons.

Blackston, Matthew A↗

Geochemistry at 4 Vesta: Observations Using Fast Neutrons

Dawn is currently in orbit around the asteroid 4 Vesta, and one of the major objectives of the mission is to probe the relationship of Vesta to the Howardite, Eucrite, and Diogenite (HED) meteorites. As Vesta is an example of a differentiated planetary embryo, Dawn will also provide fundamental information about planetary evolution in the early solar system [1]. To help accomplish this overall goal, the Dawn spacecraft carries the Gamma-Ray and Neutron Detector (GRaND). GRaND uses planetary gamma-ray and neutron spectroscopy to measure the surface elemental composition of Vesta and will provide information that is unique and complementary to that provided by the other Dawn instruments and investigations. Gamma-ray and neutron spectroscopy is a standard technique for measuring planetary compositions [2], having successfully made measurements at near-Earth asteroids, the Moon, Mars, Mercury and now Vesta. GRaND has made the first measurements of the neutron spectrum from any asteroid (previous asteroid measurements were only made with gamma-rays). Dawn has been collecting data at Vesta since July 2011. The prime data collection period for GRaND is the Low-Altitude Mapping Orbit (LAMO), which started on 12 December 2011 and will last through spring 2012. During LAMO, the Dawn spacecraft orbits at an average altitude of ~210 km above the surface of Vesta, which allows good neutron and gamma-ray signals to be detected from Vesta. A description of the overall goals of GRaND and a summary of the initial findings are given elsewhere [3,4]. The subject of this study is to present the information that will be returned from GRaND using fast neutron measurements. Here, we discuss what fast neutrons can reveal about Vesta s surface composition, how such data can address Dawn science goals, and describe fast neutron measurements made in the early portion of the Vesta LAMO phase.

Lawrence, David J.↗

Improvement in the spatial resolution for imaging with fast neutrons

In this paper, we report on the realization of an improved concept for the detection of fast neutrons using a specific setup of scintillators with the aim to overcome limitations in spatial resolution. While fast neutron imaging (FNI) is a technique to investigate very thick material layers in transmission mode, currently there is a limit in the spatial resolution at ~1 mm, which hinders the performance for the detection of features like cracks, material damage or pores in large objects ($\gg$1 cm 3 ). The improved concept presented here is based on the separation of the converter material from the scintillation layer in a suitable way, which was successfully tested and referenced to the standard devices at the NECTAR facility (FRM-2, MLZ, Garching) under realistic beamline conditions. The results imply a break-through in enabling detection of structures on the order of 0.2 to 0.5 mm (a more precise estimation is not possible due to other resolution determing factors in a realistic setup). Potential additional improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly and characterization of fast neutron detectors for TREAT fuel motion monitoring system

The TREAT fuel motion monitoring system (FMMS) currently uses a fast neutron hodoscope which allows for fast neutron imaging produced by fission in the reactor core. These neutrons are then passed unmoderated through a core slot and collimated to the 360 detector array, or hodoscope. The purpose of this project was to assemble, characterize, and qualify another 96 PMT’s to add to the current batch of 96. The assembly consists of four main components starting with a PMT, a voltage divider, a PRS button that will scintillate when struck by neutrons, and a Phenolic shroud which will house all the components to create a standard form factor. The characterization will be completed in the lab to reach the goal of having all PMT’s characterized with a determination of operability before finalized and placed inside the TREAT hodoscope.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The fast neutron fluence and the activation detector activity calculations using the effective source method and the adjoint function

This paper describes the application of effective source in forward calculations and the adjoint method to the solution of fast neutron fluence and activation detector activities in the reactor pressure vessel (RPV) and RPV cavity of a VVER-440 reactor. Its objective is the demonstration of both methods on a practical task. The effective source method applies the Boltzmann transport operator to time integrated source data in order to obtain neutron fluence and detector activities. By weighting the source data by time dependent decay of the detector activity, the result of the calculation is the detector activity. Alternatively, if the weighting is uniform with respect to time, the result is the fluence. The approach works because of the inherent linearity of radiation transport in non-multiplying time-invariant media. Integrated in this way, the source data are referred to as the effective source. The effective source in the forward calculations method thereby enables the analyst to replace numerous intensive transport calculations with a single transport calculation in which the time dependence and magnitude of the source are correctly represented. In this work, the effective source method has been expanded slightly in the following way: neutron source data were performed with few group method calculation using the active core calculation code MOBY-DICK. The follow-up neutron transport calculation was performed using the neutron transport code TORT to perform multigroup calculations. For comparison, an alternative method of calculation has been used based upon adjoint functions of the Boltzmann transport equation. Calculation of the three-dimensional (3-D) adjoint function for each required computational outcome has been obtained using the deterministic code TORT and the cross section library BGL440. Adjoint functions appropriate to the required fast neutron flux density and neutron reaction rates have been calculated for several significant points within the RPV and RPV cavity of the VVER-440 reacto rand located axially at the position of maximum power and at the position of the weld. Both of these methods (the effective source and the adjoint function) are briefly described in the present paper. The paper also describes their application to the solution of fast neutron fluence and detectors activities for the VVER-440 reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Procedure developed for reporting fast-neutron exposure

Procedure for reporting fast-neutron exposure involves determination of the spectrum shape and absolute magnitude, selection of an energy weighting for the neutrons, and definition of a unit for reporting exposure. Using this method, comparisons of irradiation data from different reactors will be free from errors resulting from differences between the spectra.

Rossin, A. D.↗

An event-triggered coincidence algorithm for fast-neutron multiplicity assay corrected for cross-talk and photon breakthrough

Here, a model quantifying detector cross-talk and the misidentification of events in fast neutron coincidence distributions is described. This is demonstrated for two experimental arrangements comprising rings of 8 and 15 organic liquid scintillation detectors. Correction terms developed as part of this model are tested with 252 Cf and a relationship is developed between the 235 U enrichment of U 3 O 8 and the order of correlated, fast neutron multiplets induced by an americium–lithium source. The model is also supported by Geant4 simulations. The results suggest that a typical assay, for experimental arrangements that are similar to the examples investigated in this research, will exhibit cross-talk for less than 1% of all detected fast neutrons but, if not accounted for, this can bias the numerical analysis by a margin of 10% and 35% in second- and third-order coincidences (i.e. couplet and triplet counts), respectively. Further, for the case of 252 Cf, it is shown that a relatively low proportion of 4% breakthrough by rays (that is, photons misidentified as neutrons by the pulse-shape discrimination process) can lead to an erroneous increase of 20% in total neutron counts in the assay of a mixed-field, in this case of 252 Cf. These findings will help direct the developments needed to enable organic scintillation detectors with pulse shape discriminators to be applied reliably to nuclear safeguards and non-proliferation verification tasks.

42 ENGINEERING↗

Reconstruction of fast neutron direction in segmented organic detectors using deep learning

A method for reconstructing the direction of a fast neutron source using a segmented organic scintillator-based detector and deep learning model is proposed and analyzed. Here, the model is based on recurrent neural network, which can be trained by a sequence of data obtained from an event recorded in the detector and suitably pre-processed. The performance of deep learning-based model is compared with the conventional double-scatter detection algorithm in reconstructing the direction of a fast neutron source. With the deep learning model, the uncertainty in source direction of 0.301 rad is achieved with 100 neutron detection events in a segmented cubic organic scintillator detector with a side length of 46 mm. To reconstruct the source direction with the same angular resolution as the double-scatter algorithm, the deep learning method requires 75% fewer events. Application of this method could augment the operation of segmented detectors operated in the neutron scatter camera configuration for applications such as special nuclear material detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Dose Evaluation Using CR39 by Coincidence Counting Process

The solid state nuclear tracks detection (SSNTD) technique is widely used in the area of radiation dosimetry. Different materials can be used applying this technique as glass and the most used in the dosimetry field that are the polycarbonates, CR39 and Makrofol-DE. Both are very rich in hydrogenous, that enables the SSNTD to detect fast neutrons through recoils of protons in the own detector material, without need of converters. The low reproducibility of its backgroundhas often been the major drawback in the assessment of low fluences of fast neutrons with SSNTDs. This problem can be effectively solved by counting coincidence of tracks in two detectors foils irradiated in close contact. After processing and counting only tracks produced by the same recoil nuclei on the surfaces of both detectors are considered as a track. This procedure enables the reduction of the background counts in the response of the detectors. In this work a preliminary study on the application of the coincidence technique for neutron dosimetry is presented. The CR39 material was investigated aiming to achieve the personal dose equivalent for fast neutrons. Using this method of analysis a significant reduction on the lower detectable dose was observed resulting even one order of magnitude smaller value. Reading, however, needs to be automated due to the large areas necessary to achieve a satisfactory number of tracks for statistical significance of results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of polyvinyl toluene scintillators for fast neutron imaging

We evaluated here polyvinyl toluene (PVT) scintillators fabricated with different emitting dopants and scintillator optical configurations for fast neutron imaging. A neutron imaging apparatus was constructed to study scintillators under MeV neutron exposure. PVT with 2% Xylyl Flrpic emitter was identified as the brightest. The addition of a black backing to the scintillator, compared with a specular reflector film backing, improved the resolution of the neutron image obtained with the PVT scintillator by about 2 ×. It is concluded that a PVT imaging screen with 2% Xylyl Flrpic, configured with a black backing, provides the best quality fast neutron image of the scintillators tested.

36 MATERIALS SCIENCE↗