Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Empirical Validation of Building Energy Modeling using Flexible Research Platform

Recently, efforts have been made to provide reliable empirical data for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, to enable improved accuracy of building energy model (BEM) engines and improved characterization of their accuracy. The motivation for this effort is that the use of reliable empirical validation data sets in the evaluation of building energy modeling tools will lead to more consistent and validated simulation engines across all software vendors. This would expedite the use of building energy modeling in designing new buildings and retrofitting existing buildings, which delivers more energy efficient buildings.As part of a three-year multi-lab empirical validation project sponsored by U.S. DOE, this research project generated cooling season test plans by reviewing ASHRAE Standard 140, and the tests were performed based on the test plan. Finally, the experimental data sets were compared with the EnergyPlus model to demonstrate the validation procedure.

Im, Piljae↗

Observational constraints to Ricci dark energy model by using: SN, BAO, OHD, fgas data sets

We perform a global constraint on the Ricci dark energy model with both the flat case and the non-flat case, using the Markov Chain Monte Carlo (MCMC) method and the combined observational data from the cluster X-ray gas mass fraction, Supernovae of type Ia (397), baryon acoustic oscillations, current Cosmic Microwave Background, and the observational Hubble function. In the flat model, we obtain the best fit values of the parameters in 1σ,2σ regions: Ω{sub m0} = 0.2927{sup +0.0420+0.0542}{sub −0.0323−0.0388}, α = 0.3823{sup +0.0331+0.0415}{sub −0.0418−0.0541}, Age/Gyr = 13.48{sup +0.13+0.17}{sub −0.16−0.21}, H{sub 0} = 69.09{sup +2.56+3.09}{sub −2.37−3.39}. In the non-flat model, the best fit parameters are found in 1σ,2σ regions:Ω{sub m0} = 0.3003{sup +0.0367+0.0429}{sub −0.0371−0.0423}, α = 0.3845{sup +0.0386+0.0521}{sub −0.0474−0.0523}, Ω{sub k} = 0.0240{sup +0.0109+0.0133}{sub −0.0130−0.0153}, Age/Gyr = 12.54{sup +0.51+0.65}{sub −0.37−0.49}, H{sub 0} = 72.89{sup +3.31+3.88}{sub −3.05−3.72}. Compared to the constraint results in the ΛCDM model by using the same datasets, it is shown that the current combined datasets prefer the ΛCDM model to the Ricci dark energy model.

79 ASTRONOMY AND ASTROPHYSICS↗

Observational constraints on the interacting Ricci dark energy model

We consider an extension of the holographic Ricci dark energy model by introducing an interaction between dark energy and matter. In this model, the dark energy density is given by {rho}{sub {Lambda}=}-(1/2){alpha}M{sub p}{sup 2}R, where R is the Ricci scalar curvature, M{sub p} is the reduced Planck mass, and {alpha} is a dimensionless parameter. The interaction rate is given by Q={gamma}H{rho}{sub {Lambda},} where H is the Hubble expansion rate, and {gamma} is a dimensionless parameter. We investigate current observational constraints on this model by applying the type Ia supernovae, the baryon acoustic oscillation and the cosmic microwave background anisotropy data. It is shown that a nonvanishing interaction rate is favored by the observations. The best fit values are {alpha}=0.45{+-}0.03 and {gamma}=0.15{+-}0.03 for the present dark energy density parameter {Omega}{sub {Lambda}0}=0.73{+-}0.03.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilgrim Hot Springs Building Dimensions and Energy Modeling

This dataset was created to model the anticipated heating load of a geothermal project in development for the historical site of Pilgrim Hot Springs, and adds to the history of geothermal studies at the site. Models include an historical building (Nun's Quarters), existing modern buildings (Caretaker's Cabin, Igloo, Visitor's Cabin, Staff Shower Hut), and planned building projects (Changing Room, Greenhouse). Modeling results were used to determine feasible geothermal system typologies. The previous study linked below ("Village of Solomon Development of Energy Efficiency Building Standards for New Construction") feeds in to this project. The dataset includes DWG drawings and AKwarm energy models (.hm2) of a subset of existing buildings at the site of Pilgrim Hot Springs. All buildings were modeled in their current state, and some were additionally modeled with improvements to the building envelope. Energy modeling results exported from AKwarm include .htm and .png images.

AKwarm↗

Energy Modeling for the Artisan Food Center

The Artisan Food Center is a 6912 sq.ft food processing plant located in Dayton, Washington. PNNL was contacted by Strecker Engineering to assist with the building’s energy analysis as a part of the project’s U.S. Green Building Council’s Leadership in Energy and Environmental Design (LEED) submittal requirements. The project is aiming for LEED Silver certification, one of the prerequisites to which is a whole building energy model to demonstrate compliance with American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE) 90.1 2007 Appendix G, Performance Rating Method. The building incorporates a number of energy efficiency measures as part of its design and the energy analysis aimed at providing Strecker Engineering with the know-how of developing an energy model for the project as well as an estimate of energy savings of the proposed design over the baseline design, which could be used to document points in the LEED documentation. This report documents the ASHRAE 90.1 2007 baseline model design, the proposed model design, the modeling assumptions and procedures as well as the energy savings results in order to inform the Strecker Engineering team on a possible whole building energy model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On dark energy models of single scalar field

In this paper we revisit the dynamical dark energy model building based on single scalar field involving higher derivative terms. By imposing a degenerate condition on the higher derivatives in curved spacetime, one can select the models which are free from the ghost mode and the equation of state is able to cross the cosmological constant boundary smoothly, dynamically violate the null energy condition. Generally the Lagrangian of this type of dark energy models depends on the second derivatives linearly. It behaves like an imperfect fluid, thus its cosmological perturbation theory needs to be generalized. We also study such a model with explicit form of degenerate Lagrangian and show that its equation of state may cross -1 without any instability.

79 ASTRONOMY AND ASTROPHYSICS↗

ReVision Home: Energy Modeling

This fact sheet provides information about specifications and energy modeling results of the ReVision Home in Las Vegas, NV.

CARB↗

Evaluation of an Incremental Ventilation Energy Model for Estimating Impacts of Air Sealing and Mechanical Ventilation

Changing the rate of airflow through a home affects the annual thermal conditioning energy. Large-scale changes to airflow rates of the housing stock can significantly alter the energy consumption of the residential energy sector. However, the complexity of existing residential energy models hampers the ability to estimate the impact of policy changes on a state or nationwide level. The Incremental Ventilation Energy (IVE) model developed in this study was designed to combine the output of simple airflow models and a limited set of home characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modelers to use existing databases of home characteristics to determine the impact of policy on ventilation at a population scale. In this report, we describe the IVE model and demonstrate that its estimates of energy change are comparable to the estimates of a wellvalidated, complex residential energy model when applied to homes with limited parameterization. Homes with extensive parameterization would be more accurately characterized by complex residential energy models. The demonstration included a range of home types, climates, and ventilation systems that cover a large fraction of the residential housing sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Revisiting dark energy models using differential ages of galaxies

In this work, we use a test based on the differential ages of galaxies for distinguishing the dark energy models. As proposed by Jimenez and Loeb in [1], relative ages of galaxies can be used to put constraints on various cosmological parameters. In the same vein, we reconstruct H {sub 0} {sub dt} / dz and its derivative ( H {sub 0} {sub d} {sup 2} {sup t} / dz {sup 2}) using a model independent technique called non-parametric smoothing . Basically, dt / dz is the change in the age of the object as a function of redshift which is directly linked with the Hubble parameter. Hence for reconstruction of this quantity, we use the most recent H ( z ) data. Further, we calculate H {sub 0} {sub dt} / dz and its derivative for several models like Phantom, Einstein de Sitter (EdS), ΛCDM, Chevallier-Polarski-Linder (CPL) parametrization, Jassal-Bagla-Padmanabhan (JBP) parametrization and Feng-Shen-Li-Li (FSLL) parametrization. We check the consistency of these models with the results of reconstruction obtained in a model independent way from the data. It is observed that H {sub 0} {sub dt} / dz as a tool is not able to distinguish between the ΛCDM, CPL, JBP and FSLL parametrizations but, as expected, EdS and Phantom models show noticeable deviation from the reconstructed results. Further, the derivative of H {sub 0} {sub dt} / dz for various dark energy models is more sensitive at low redshift. It is found that the FSLL model is not consistent with the reconstructed results, however, the ΛCDM model is in concordance with the 3σ region of the reconstruction at redshift z ≥ 0.3.

79 ASTRONOMY AND ASTROPHYSICS↗

Revisit of the interacting holographic dark energy model after Planck 2015

We investigate the observational constraints on the interacting holographic dark energy model. We consider five typical interacting models with the interaction terms Q = 3β H ρ{sub de}, Q = 3β H ρ{sub c}, Q = 3β H (ρ{sub de}+ρ{sub c}), Q = 3β H √ρ{sub de}ρ{sub c}, and Q = 3β H ρ{sub de}ρ {sub c} /ρ{sub de}+ρ{sub c}, respectively, where β is a dimensionless coupling constant. The observational data we use in this paper include the JLA compilation of type Ia supernovae data, the Planck 2015 distance priors data of cosmic microwave background observation, the baryon acoustic oscillations measurements, and the Hubble constant direct measurement. We make a comparison for these five interacting holographic dark energy models by employing the information criteria, and we find that, within the framework of holographic dark energy, the Q = 3β H ρ{sub de}ρ{sub c}/ρ{sub de}+ρ{sub c} model is most favored by current data, and the Q = 3β H ρ{sub c} model is relatively not favored by current data. For the Q = 3β H ρ{sub de} and Q = 3β H ρ{sub de}ρ{sub c}/ρ{sub de}+ρ{sub c} models, a positive coupling β can be detected at more than 2σ significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Computing Nonlinear Power Spectra Across Dynamical Dark Energy Model Space with Neural ODEs

I show how to compute the nonlinear power spectrum across the entire $w(z)$ dynamical dark energy model space. Using synthetic ΛCDM data, I train a neural ordinary differential equation (ODE) to infer the evolution of the nonlinear matter power spectrum as a function of the background expansion and mean matter density across ∼9 Gyr of cosmic evolution. After training, the model generalises to any dynamical dark energy model parameterised by $w(z)$. With little optimisation, the neural ODE is accurate to within 4% up to $k = 5\, h\, {\mathrm Mpc}^{−1}$. Unlike simulation rescaling methods, neural ODEs naturally extend to summary statistics beyond the power spectrum that are sensitive to the growth history.

cosmology↗

A Data-Driven Approach to Nation-Scale Building Energy Modeling

In 2019, 125 million U.S. residential and commercial buildings consumed $412 billion in energy bills. These buildings currently consume 40% of the nation's primary energy, 73% of electricity, 80% of energy during peak electric grid use, and responsible for 39% of greenhouse gas emissions [14]. Urban-scale building energy modeling has grown significantly in the past decade, allowing individual campuses or communities of buildings to be modeled, simulated, and cost-effective solutions for intelligent management to be identified and implemented. While traditionally limited to individual counties and usually less than 2,000 buildings, the Automatic Building Energy Modeling (AutoBEM) soft-ware suite has been developed to process unconventional, nation-scale data sources to generate unique OpenStudio and EnergyPlus models of each building. Through the use of High Performance Computing (HPC) resources, every U.S. building has been simulated. This paper showcases the data layout, node partitioning, algorithmic approaches, and analytic results that were used to create, share, and analyze 124.4 million U.S. building models.

Berres, Andy↗

Comparing projections of industrial energy demand and greenhouse gas emissions in long-term energy models

The industry sector consumes more energy and emits more greenhouse gas (GHG) emissions than any other end-use sector. Integrated assessment models (IAMs) and energy system models have been widely used to evaluate climate policy at a global level, and include a representation of industrial energy use. In this study, the projected industrial energy use and accompanying GHG emissions, as well as the model structure of multiple long-term energy models are compared. The models show varying degrees to which energy consumption is decoupled from GDP growth in the future. In all models, the sector remains mostly (>50%) reliant on fossil energy through 2100 in a reference scenario (i.e., absent emissions mitigation policies), though there is significant divergence in the projected ability to switch to alternative fuels to mitigate GHG emissions. Among the set analyzed here, the more technologically detailed models tend to have less capacity for switching from fossil fuels to electricity. This highlights the importance of understanding of economy-wide mitigation responses and costs as an area for future improvement. Analyzing industry subsector material and energy use details can improve the ability to interpret results, and provide insight in feasibility of how emissions reduction can be achieved.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Community Geothermal: Soil Conductivity, Borehole Design, Energy Models, and Load Data for a Residential System Development - Hinesburg, VT

This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.

15 GEOTHERMAL ENERGY↗

Predicting the performance of radiant technologies in attics: Reducing the discrepancies between attic specific and whole-building energy models

The use of radiant technology in attics aims to reduce the radiation component of heat transfer between the attic floor and roof decks, gables, and eaves. Recently, it has been shown that EnergyPlus underestimates the savings using radiant technologies in attic spaces. The aim of this study is to understand why EnergyPlus underestimates the performance of radiant technologies and provide a solution strategy that works within the current capabilities of EnergyPlus. The analysis uses three attic energy models as a baseline for comparison for EnergyPlus. Potential reasons for the discrepancies between the attic specific energy models and EnergyPlus are isolated and individually tested. A solution strategy is proposed using the Energy Management System (EMS) capabilities within EnergyPlus. This solution strategy produces similar results to the other attic specific energy models. This paper shows that the current capabilities of EnergyPlus are sufficient to simulate radiant technologies in attics. The methodology showcased in this paper serves as a guide for engineers and researchers who would like to predict the performance radiant technology in attics using the whole building energy software, EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D Reality Energy Modeling Software

The team will combine Bentley Systems’ ContextCapture and extend Oak Ridge National Laboratory’s building energy modeling capabilities in order to create digital twins of buildings that allow simulation-informed improvement for energy efficiency and demand response in the design and operation of the built environment. Bentley Systems’ ContextCapture software processes data from 3D laser scanning and photographs (through photogrammetry) to create a photorealistic, 3D mesh with a scale of individual objects to building to city-sized. This capability easily provides city-level visualization models and platforms where sustainable design alternatives are readily evaluated. Oak Ridge National Laboratory (ORNL) serves the U.S. Dept. of Energy (DOE) as one of three core laboratories developing building energy modeling tools EnergyPlus and OpenStudio. ORNL’s AutoBEM software (bit.ly/AutoBEM) can process imagery (satellite, aerial, and street level), LiDAR, cartographic layers, tax assessor’s data, and other data sources to extract building footprints, height, window-to-wall ratio, building type, vintage, and other building properties. AutoBEM has created 178,368 building energy models that were empirically validated with 15-minute whole-building electrical data from a utility.

97 MATHEMATICS AND COMPUTING↗

Bifacial PV Module Energy Modeling Validation Study

The cost delta between monofacial and bifacial photovoltaic (PV) modules was decreasing in 2018 when this study was initially proposed, making bifacial modules an attractive offering. However, there were limited field studies available that could be considered utility-scale representative, and PV module manufacturers were stating large ranges for the expected energy yield improvements of bifacial technology. This generated uncertainties regarding bifacial performance gains and the actual LCOE (levelized cost of energy). There was also relatively low confidence in the industry’s energy modeling tools’ ability to accurately predict bifacial energy yield, meaning that early adopters of bifacial modules were not able to fully account for the increased energy yield in their energy and financial models. The intent of this project was to provide the solar industry with greater certainty on the energy yield gains of bifacial modules and provide higher confidence in the ability for different energy modeling software to model bifacial PV site performance. Achieving this would allow for bifacial technology to become bankable (i.e. accepted by Independent Engineers, site financiers and other PV site stakeholders), offering a step change in PV site performance that had not been seen since the widespread adoption of the single-axis tracker. Over the course of this study other economic factors including a significant tariff exemption for bifacial modules resulted in accelerated adoption of bifacial technology throughout the US utility scale solar segment. The number of early adopters increased rapidly, and with many investors accepting this module choice the question of bifacial bankability was seemingly answered faster than expected. However, PVEL’s study has still achieved significant accomplishments in demonstrating the accuracy of bifacial modeling across three different software platforms. The results of this study have shown that the mean biased error (MBE) between the field data and the predicted values from all three software platforms were aligned with a maximum MBE of 1.3% and a minimum MBE of -1.8%.

14 SOLAR ENERGY↗