Improving Building Energy Simulation Programs Through Diagnostic Testing (Fact Sheet)
New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market.
The study examines the impact of variable air volume (VAV) damper stuck faults on the system operation, building indoor conditions, and reheating energy consumption. This study includes both experimental and simulation studies for five test scenarios, including a fault-free scenario. We implemented VAV damper stuck fault through the building automation system (BAS). Results show that a damper stuck in a high opening position (60% damper opening) results in supplying an excessive amount of cold air from the rooftop unit (RTU) to the conditioned zone, increasing reheating energy consumption. The results of this research can serve as a foundational resource for developing fault detection algorithms.
Semiconductor manufacturing is a highly complex. Fabrication plants must deal with re-entrant flows to support multiple types of wafers being produced simultaneously, each with their own deadlines and specifications. The manufacturing process itself depends upon the ability to control and programmatically adjust a variety of environmental conditions including temperature, humidity, and air quality. In addition, wafer fabrication consumes large amounts of electricity. Emerging technologies may help reduce the energy footprint of such facilities but can introduce cybersecurity risks. Therefore, this paper presents a modeling and simulation framework to quantify tradeoffs between operational measures of performance, energy consumption, and cybersecurity controls. We augment the Intel Minifab model, with the Purdue Enterprise Reference Architecture (PERA) for cybersecurity as well as tool-level energy consumption data from a real-world semiconductor manufacturing testbed. In this manner, we intend to provide stakeholders with a systematic, data-driven approach to evaluate emerging risks within the manufacturing process.
Within the confines of the Maritime Prescreening Assessment of Conservation Technologies program, the U.S. Department of Energy's National Renewable Energy Laboratory, in collaboration with the Naval Surface Warfare Center Carderock and Philadelphia Divisions, the U.S. Department of Transportation's Maritime Administration, and the Massachusetts Maritime Academy, recently developed a physics-based modeling engine to evaluate non-propulsive ship energy consumption under different operational scenarios and technology applications, in order to enhance the Navy's ability to optimize ship operational reach and tactical performance. To accomplish this, a mature thermophysical modeling software, EnergyPlus TM , was modified for ship-related applications. This software, originally developed for use in whole-building energy consumption studies, is a free and open-source simulation program that has been used for more than two decades. The team evaluated the accuracy of the modified version of EnergyPlus by comparing results to direct measurements taken over a 6-week underway period onboard the Maritime Administration's Training Ship Kennedy. The team developed an energy model of a prescribed area of the ship and compared its performance to measured results obtained from 235 sensor points. EnergyPlus behaved well with respect to solar loading and convective heat transfer to seawater while the ship was underway. However, results suggest that additional work remains to accurately simulate seawater heat transfer while the ship is stationary.
We examine large-eddy-simulation modeling approaches and computational performance of two open-source computational fluid dynamics codes for the simulation of atmospheric boundary layer flows that are of direct relevance to wind energy production. The first code, NekRS, is a high-order, unstructured-grid, spectral element code. The second code, AMR-Wind, is a second-order, block-structured, finite-volume code with adaptive mesh refinement capabilities. The objective of this study is to co-develop these codes in order to improve model fidelity and performance for each. These features will be critical for running ABL-based applications such as wind farm analysis on advanced computing architectures. To this end, we investigate the performance of NekRS and AMR-Wind on the Oak Ridge Leadership Facility supercomputers Summit, using 4 to 800 nodes (24 to 4,800 NVIDIA V100 GPUs), and Crusher, the testbed for the Frontier exascale system, using 18 to 384 Graphics Compute Dies on AMD MI250X GPUs. We compare strong- and weak-scaling capabilities, linear solver performance, and time to solution. We also identify leading inhibitors to parallel scaling.
In order to study grid-interactive efficient buildings, Pacific Northwest National Laboratories (PNNL) needs an infrastructure for urban-scale building energy modeling. Such an infrastructure should be fast, scalable, and easy-to-use. Given a set of data from the Energy Information Administration’s Commercial Building Energy Consumption Survey (CBECS) and tool to translate survey data into simulation inputs, this project aimed to conduct the simulation of the entire dataset in parallel. Before running the simulations, the necessary software was bundled into a container for use on the PNNL supercomputing network. Then, the parallel simulation workflow was designed using GNU Make, a file creation software, and submitted to a supercomputing partition which could run hundreds of simulations simultaneously. The EnergyPlus simulations output hourly electric meter data for each CBECS sample, which represents the electricity consumption of similar commercial buildings across the United States. Analyzing and visualizing the meter data is important to the future of the work, and this project wrote code to make common analysis methods simple, fast, and accessible. Moving forwards, the model will need to be expanded to include data from other sources and its accuracy will need to be improved and eventually validated.
This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.
Classical molecular dynamics simulations coupled with umbrella sampling reveal the atomistic processes and free-energy profiles of the displacement of carbonate groups in the Ca 2 UO 2 (CO 3 ) 3 complex by amidoxime-based ligands in a 0.5 M NaCl solution.
Explore the source record for details and available documents.
Accurate predictions on non-linear power spectra, at various redshift z, will be a basic tool to interpret cosmological data from next generation mass probes, so obtaining key information on Dark Energy nature. This calls for high precision simulations, covering the whole functional space of w(z) state equations and taking also into account the admitted ranges of other cosmological parameters; surely a difficult task. A procedure was however suggested, able to match the spectra at z = 0, up to k {approx} 3 hMpc{sup -1}, in cosmologies with an (almost) arbitrary w(z), by making recourse to the results of N-body simulations with w = const. In this paper we extend such procedure to high redshift and test our approach through a series of N-body gravitational simulations of various models, including a model closely fitting WMAP5 and complementary data. Our approach detects w = const. models, whose spectra meet the requirement within 1% at z = 0 and perform even better at higher redshift, where they are close to a permil precision. Available Halofit expressions, extended to (constant) w{ne}-1 are unfortunately unsuitable to fit the spectra of the physical models considered here. Their extension to cover the desired range should be however feasible, and this will enable us to match spectra from any DE state equation.
S -Adenosyl-l-methionine (SAM) dependent xanthosine methyltransferase (XMT) is the key enzyme that catalyzes the first methyl transfer in the caffeine biosynthesis pathway to produce the intermediate 7-methylxanthosine (7mXR). Although XMT has been a subject of extensive discussions, the catalytic mechanism and nature of the substrate involved in the catalysis are still unclear. Here in this paper, quantum mechanical/molecular mechanical (QM/MM) molecular dynamics (MD) and free energy (potential of mean force or PMF) simulations are undertaken to determine the catalytic mechanism of the XMT-catalyzed reaction. Both xanthosine and its monoanionic form with N3 deprotonated are used as the substrates for the methylation. It is found that while the methyl group can be transferred to the monoanionic form of xanthosine with a reasonable free energy barrier (about 17 kcal/mol), that is not the case for the neutral xanthosine. The results suggest that the substrate for the first methylation step in the caffeine biosynthesis pathway is likely to be the monoanionic form of xanthosine rather than the neutral form as widely adopted. This conclusion is supported by the p K a value on N3 of xanthosine both measured in aqueous phase and calculated in the enzymatic environment. As a result, the structural and dynamics information from both the X-ray structure and MD simulations is also consistent with the monoanionic xanthosine scenario. Finally, we discuss the implications of this conclusion for caffeine biosynthesis.
Abstract not provided
This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define 'explicit' input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.
This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define "explicit" input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.
Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.
Abstract not provided
EnergyPlus{sup TM} is a new generation computer software analysis tool that has been developed, tested, and commercialized to support DOE's Building Technologies (BT) Program in terms of whole-building, component, and systems R&D (http://www.energyplus.gov). It is also being used to support evaluation and decision making of zero energy building (ZEB) energy efficiency and supply technologies during new building design and existing building retrofits. The 5-year project was managed by the National Energy Technology Laboratory and was divided into 5 budget period between 2006 and 2011. During the project period, 11 versions of EnergyPlus were released. This report summarizes work performed by an EnergyPlus development team led by the University of Central Florida's Florida Solar Energy Center (UCF/FSEC). The team members consist of DHL Consulting, C. O. Pedersen Associates, University of Illinois at Urbana-Champaign, Oklahoma State University, GARD Analytics, Inc., and WrightSoft Corporation. The project tasks involved new feature development, testing and validation, user support and training, and general EnergyPlus support. The team developed 146 new features during the 5-year period to advance the EnergyPlus capabilities. Annual contributions of new features are 7 in budget period 1, 19 in period 2, 36 in period 3, 41 in period 4, and 43 in period 5, respectively. The testing and validation task focused on running test suite and publishing report, developing new IEA test suite cases, testing and validating new source code, addressing change requests, and creating and testing installation package. The user support and training task provided support for users and interface developers, and organized and taught workshops. The general support task involved upgrading StarTeam (team sharing) software and updating existing utility software. The project met the DOE objectives and completed all tasks successfully. Although the EnergyPlus software was enhanced significantly under this project, more enhancements are needed for further improvement to ensure that EnergyPlus is able to simulate the latest technologies and perform desired HAVC system operations for the development of next generation HVAC systems. Additional development will be performed under a new 5-year project managed by the National Renewable Energy Laboratory.
Vertical-axis wind turbines (VAWTs) have been the subject of research and development for nearly a century. However, this turbine architecture has fallen in and out of favor on multiple occasions. Beginning in the late 1970s, the U.S. Department of Energy sponsored an extensive experimental program through Sandia National Laboratories which produced a mass of experimental data from several highly instrumented turbines. Turbines designed, built, and tested include the 2 meter, 5 meter, 17 meter, and 34 meter and their respective configurations. This program kicked off a commercial collaboration and resulted in the FloWind turbines. The FloWind turbines had several notable design changes from the experimental turbines that, in conjunction with a general lack of understanding regarding predicting fatigue at the time, led to the majority of the turbines failing prematurely during the late 80s.