A diagnostic for determining the quality of single-reference electron correlation methods

It was recently proposed that the Euclidian norm of the t sub 1 vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appropriate. This diagnostic, T sub 1, is defined for use with self consistent field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T sub 1 is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of nondynamical electron correlation and is far superior to C sub 0 from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T sub 1 (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.

Lee, Timothy J.↗

A diagnostic for determining the quality of single-reference electron correlation methods

It was recently proposed that the Euclidian norm of the t(sub 1) vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appopriate. This diagnostic, T(sub 1) is defined for use with self-consistent-field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T(sub 1) is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of non-dynamical electron correlation and is far superior to C(sub 0) from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T(sub 1) (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.

Lee, Timothy J.↗

A Deterministic Transport Code for Space Environment Electrons

A deterministic computational procedure has been developed to describe transport of space environment electrons in various shield media. This code is an upgrade and extension of an earlier electron code. Whereas the former code was formulated on the basis of parametric functions derived from limited laboratory data, the present code utilizes well established theoretical representations to describe the relevant interactions and transport processes. The shield material specification has been made more general, as have the pertinent cross sections. A combined mean free path and average trajectory approach has been used in the transport formalism. Comparisons with Monte Carlo calculations are presented.

Nealy, John E.↗

Technique for measuring basic characteristics of electron-optical cameras

A procedure is described for determining the basic parameters of linear-sweep electron-optical cameras. The techniques are considered for measuring the limiting temporal resolution and dynamic range of the PS-1/S1 camera using a femtosecond laser and sinusoidal-modulated laser radiation. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small Particle Response to Fluid Motion Using Tethered Particles to Simulate Microgravity

This paper reports on ground based work conducted to support the Spaceflight Definition project SHIVA (Spaceflight Holography Investigation in a Virtual Apparatus). SHIVA will advance our understanding of the movement of a particle in a fluid. Gravity usually dominates the equations of motion, but in microgravity as well as on earth other terms can become important. Through an innovative application of fractional differential equations, two members of our team produced the first analytical solution of a fundamental equation of motion, which had only been solved numerically or by approximation before. The general solution predicts that the usually neglected history term becomes important in particle response to a sinusoidal fluid movement when the characteristic viscous time is in the same order as the fluid oscillation period and peaks when the two times are equal. In this case three force terms, the Stokes drag, the added mass, and the history drag must all be included in predicting particle movement. We have developed diagnostic recording methods using holography to save all of the particle field data, allowing the experiment to essentially be transferred from space back to earth in what we call the virtual apparatus for on-earth microgravity experimentation. We can quantify precisely the three-dimensional motion of sets of particles, allowing us to test and apply the new analytical solutions. We are examining the response of particles up to 2 mm radius to fluid oscillation at frequencies up to 80 Hz with amplitudes up to 200 microns. Ground studies to support the flight development program have employed various schemes to simulate microgravity. One of the most reliable and meaningful methods uses spheres tethered to a fine hair suspended in the fluid. We have also investigated particles with nearly neutral buoyancy. Recordings are made at the peak amplitudes of vibration of the cell providing a measure of the ratio of fluid to particle amplitude. The experiment requires precise location of the particle to within microns during recording, and techniques for achieving this are one of the project challenges. Focused microscopic images and diffraction patterns are used. To make the experiment more versatile, the spaceflight system will record holograms both on film and electronically. A cross correlation procedure enables sub pixel accuracies for electronic recordings, partially accommodating the lower spatial resolution of CCDs. The electronic holograms can be down linked providing real time data. Results of the ground experiments, the flight experiment design, and data analysis procedures are reported.

Trolinger, James↗

Are Current SEE Test Procedures Adequate for Modern Devices and Electronics Technologies?

Believe it or not, this has been a simplistic look at starting a checklist for SEE testing. Given a memory that has 68 operating modes, when a SEU occurs that changes the mode, just how do you determine what's going on? Laser and microbeam tests can help, but not easily for modern packaged devices. Expanding this approach to other more complex devices such as ADCs or processors as well as analog devices should be considered. The recommendation is to use the existing text standards as the starting point. Just make your own checklist for the device/technology/issues being considered. At HEART 2007, we presented some of the burgeoning challenges associated with single event effect(SEE) testing of modern commercial memories: a) Package, device complexity, test fixture, and data analysis issues were discussed; b) "Complete" SEE Characterization would take 15 years; c) Qualification test costs have a greater than 4 times increase over the last decade. In this talk, we continue to explore the roles of technology with an emphasis on the existing SEE Test Procedures and some of the concerns related to modern devices. The primary objective of the briefing is to provide some overarching guidance concerning the many considerations involved in the formulation of a SEE test plan provided in a " Checklist" format.we note that there is no such thing as a complete check list and that the best approach is to develop a flexible test plan that takes into account the device type and functions, the device technology, circuit and package design, and, of course, test facility and beam characteristics.

LaBel, Kenneth A.↗

Vaccinia virions deficient in transcription enzymes lack a nucleocapsid

The poxvirus virion contains an inner tubular nucleocapsid structure. The nucleocapsid is apparently labile to conventional electron microscopy fixation procedures and has therefore been largely ignored for decades. Advancements in electron microscopy sample preparation, notably high pressure freezing, better preserve the nucleocapsid structure. Using high pressure freezing and electron microscopy, we have compared the virion structures of wt virus and mutant viruses known to be deficient in packaging of viral transcription enzymes. We show that the mutant viruses lack a defined nucleocapsid. These results support the hypothesis that the nucleocapsid contains the viral DNA genome complexed with viral transcription enzymes and structural proteins. The studies open the door to further investigation of the composition and ultrastructure of the poxvirus nucleocapsid.

60 APPLIED LIFE SCIENCES↗

Effect of Alignment on Transport Properties of Carbon Nanotube/Metallic Junctions

Ballistic and spin coherent transport in single walled carbon nanotubes (SWCNT) are predicted to enable high sensitivity single-nanotube devices for strain and magnetic field sensing. Based upon these phenomena, electron beam lithography procedures have been developed to study the transport properties of purified HiPCO single walled carbon nanotubes for development into sensory materials for nondestructive evaluation. Purified nanotubes are dispersed in solvent suspension and then deposited on the device substrate before metallic contacts are defined and deposited through electron beam lithography. This procedure produces randomly dispersed ropes, typically 2 - 20 nm in diameter, of single walled carbon nanotubes. Transport and scanning probe microscopy studies have shown a good correlation between the junction resistance and tube density, alignment, and contact quality. In order to improve transport properties of the junctions a technique has been developed to align and concentrate nanotubes at specific locations on the substrate surface. Lithographic techniques are used to define local areas where high frequency electric fields are to be concentrated. Application of the fields while the substrate is exposed to nanotube-containing solution results in nanotube arrays aligned with the electric field lines. A second electron beam lithography layer is then used to deposit metallic contacts across the aligned tubes. Experimental measurements are presented showing the increased tube alignment and improvement in the transport properties of the junctions.

Wincheski, Buzz↗

Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM

For commissioning a linear accelerator for clinical use, medical physicists are faced with many challenges including the need for precision, a variety of testing methods, data validation, the lack of standards, and time constraints. Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and proper tools and should be independent of the person collecting the data. To achieve this goal, Task Group 106 (TG-106) of the Therapy Physics Committee of the American Association of Physicists in Medicine was formed to review the practical aspects as well as the physics of linear accelerator commissioning. The report provides guidelines and recommendations on the proper selection of phantoms and detectors, setting up of a phantom for data acquisition (both scanning and no-scanning data), procedures for acquiring specific photon and electron beam parameters and methods to reduce measurement errors (<1%), beam data processing and detector size convolution for accurate profiles. The TG-106 also provides a brief discussion on the emerging trend in Monte Carlo simulation techniques in photon and electron beam commissioning. The procedures described in this report should assist a qualified medical physicist in either measuring a complete set of beam data, or in verifying a subset of data before initial use or for periodic quality assurance measurements. By combining practical experience with theoretical discussion, this document sets a new standard for beam data commissioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact variational wave functions for bound states in three-electron atomic systems

The variational procedure to construct compact and accurate wave functions for three-electron atoms and ions is developed. The procedure is based on the use of six-dimensional Gaussoids written in the relative four-body coordinates r{sub 12}, r{sub 13}, r{sub 23}, r{sub 14}, r{sub 24}, and r{sub 34}. The nonlinear parameters in each basis function have been carefully optimized. Using these variational wave functions, we have determined the energies and other bound state properties for the ground 1{sup 2}S-states in a number of three-electron atoms and ions. The three-electron atomic systems considered in this work include the neutral Li atom and nine positively charged lithiumlike ions: Be{sup +}, B{sup 2+}, C{sup 3+}, ..., Na{sup 8+}, and Mg{sup 9+}. Our variational wave functions are used to determine the hyperfine structure splitting and field shifts for some lithium-like ions. The explicit formulas of the Q{sup -1} expansion are derived for the total energies of these three-electron systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and simulation of a 30 kV, 60 kW electron optical column for melting applications

Electron beam offers unique advantages as a heat source for melting of refractory metals. It provides contamination free homogeneous melting with precise heat control on the melt target. This paper reports the complete electron optics design procedure for a 30 kV, 60 kW melting gun. The design objective of the electron optical column is to obtain the required power density on the target (10{sup 3}-10{sup 4} W/cm{sup 2}) using electrostatic and electromagnetic lenses. The design constrains are to minimize the high voltage discharges in the gun and beam losses in the beam transport. The challenging task of reducing the electrical discharges in the gun during high power melting with the help of twin electromagnetic lenses is presented in the paper. (author)

43 PARTICLE ACCELERATORS↗

Properties of low-energy electron precipitation in the cleft during periods of unusually high ambient electron temperatures

A recently developed automated fitting procedure for Dynamics Explorer 2 electron energy spectra represents each auroral electron spectrum as a superposition of several Maxwellian and several Gaussian components. The fitting parameters give a digital representation which uniquely describes each spectrum. It is shown that unusually high ambient electron temperatures (of the order of 10,000 K) in the cleft are strongly correlated with the intensity parameters of the lowest-temperature Maxwellian components of the precipitation. The collisional heat input into the ambient electrons by these Maxwellian components of the precipitation fluxes is shown to be more than an order of magnitude higher in the high-temperature storm time cases than it is in a control set of 'normal temperature' quiet time cases. The heating effect of the solar flux is shown to be nearly the same for both sets of cases. As a result it is concluded that electron precipitation is the chief mechanism responsible for those high ambient temperatures.

Fontheim, Ernest G.↗