Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluating the accuracy of common γ-Al 2 O 3 structure models by selected area electron diffraction from high-quality crystalline γ-Al 2 O 3

Single crystal and textured polycrystalline γ-Al 2 O 3 thin films were synthesized by oxidation of NiAl(110) in air at 850 °C for 1 and 2 hours, respectively, and used to evaluate the accuracy of two spinel-based and two nonspinel models by comparison of selected-area electron diffraction (SAED). The lattice interplanar distances derived from the polycrystalline SAED pattern most closely matched the cubic spinel γ-Al 2 O 3 model. The single-crystal SAED spot pattern reflected symmetry consistent with both the cubic spinel and tetragonal nonspinel models, yet, the Al cation distribution better matched the cubic spinel model based on the relative intensities of diffraction spots. Our work indicates that the traditional cubic spinel model is a more accurate model of γ-Al 2 O 3 than the other models considered. Furthermore, the spinel-based monoclinic model is more accurate than the monoclinic nonspinel model. The understanding of the relative accuracy of the different models is key for simulating γ-Al 2 O 3 containing systems and is of general interest for the metal oxide and ceramic communities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Laser-assisted electron diffraction for femtosecond molecular imaging

We report the observation of laser-assisted electron diffraction (LAED) through the collision of 1 keV electrons with gas-phase CCl{sub 4} molecules in a femtosecond near-infrared laser field. In the angular distribution of the scattered electrons with the energy shifts of ±ℏω, we observed clear diffraction patterns which reflect the geometrical structure of the molecules at the moment of laser irradiation. Our results demonstrate that ultrafast nuclear dynamics of molecules can be probed by LAED with the high temporal (<10 fs) and spatial (∼0.01 Å) resolutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ nanobeam electron diffraction strain mapping of planar slip in stainless steel

Nanobeam electron diffraction strain mapping has been used to measure the strain evolution in stainless steel under in situ deformation. As the amount of deformation increases, the leading dislocation of a planar slip band leaves behind a residual strain in the form of a small lattice expansion. Dislocation analysis confirmed that the dislocations involved were <011> type. Even though, the characteristic residual strain of planar slip has often been observed, it has never before been directly measured. Our conclusions provide a view into the dynamic mechanisms of planar slip, and showcase the possibilities of multidimensional in situ imaging.

36 MATERIALS SCIENCE↗

Extracting conformational structure information of benzene molecules via laser-induced electron diffraction

Here, we have measured the angular distributions of high energy photoelectrons of benzene molecules generated by intense infrared femtosecond laser pulses. These electrons arise from the elastic collisions between the benzene ions with the previously tunnel-ionized electrons that have been driven back by the laser field. Theory shows that laser-free elastic differential cross sections (DCSs) can be extracted from these photoelectrons, and the DCS can be used to retrieve the bond lengths of gas-phase molecules similar to the conventional electron diffraction method. From our experimental results, we have obtained the C-C and C-H bond lengths of benzene with a spatial resolution of about 10 pm. Our results demonstrate that laser induced electron diffraction (LIED) experiments can be carried out with the present-day ultrafast intense lasers already. Looking ahead, with aligned or oriented molecules, more complete spatial information of the molecule can be obtained from LIED, and applying LIED to probe photo-excited molecules, a “molecular movie” of the dynamic system may be created with sub-A°ngstrom spatial and few-ten femtosecond temporal resolutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiple origins of extra electron diffractions in fcc metals

Diffuse intensities in the electron diffraction patterns of concentrated face-centered cubic solid solutions have been widely attributed to chemical short-range order, although this connection has been recently questioned. This article explores the many nonordering origins of commonly reported features using a combination of experimental electron microscopy and multislice diffraction simulations, which suggest that diffuse intensities largely represent thermal and static displacement scattering. A number of observations may reflect additional contributions from planar defects, surface terminations incommensurate with bulk periodicity, or weaker dynamical effects.

36 MATERIALS SCIENCE↗

Random forest prediction of crystal structure from electron diffraction patterns incorporating multiple scattering

Diffraction is the most common method to solve for unknown or partially known crystal structures. However, it remains a challenge to determine the crystal structure of a new material that may have nanoscale size or heterogeneities. Here, in this study, we train an architecture of hierarchical random forest models capable of predicting the crystal system, space group, and lattice parameters from one or more unknown two-dimensional electron diffraction patterns. Our initial model correctly identifies the crystal system of a simulated electron diffraction pattern from a 20-nm-thick specimen of arbitrary orientation 67% of the time. We achieve a topline accuracy of 79% when aggregating predictions from ten patterns of the same material but different zone axes. The space group and lattice predictions range from 70% to 90% accuracy and median errors of 0.01-0.5Å, respectively, for cubic, hexagonal, trigonal, and tetragonal crystal systems while being less reliable on orthorhombic and monoclinic systems. We apply this architecture to a four-dimensional scanning transmission electron microscopy scan of gold nanoparticles, where it accurately predicts the crystal structure and lattice constants. These random forest models can be used to significantly accelerate the analysis of electron diffraction patterns, particularly in the case of unknown crystal structures. Additionally, due to the speed of inference, these models could be integrated into live transmission electron microscopy experiments, allowing real-Time labeling of a specimen.

36 MATERIALS SCIENCE↗

High quality single shot ultrafast MeV electron diffraction from a photocathode radio-frequency gun

A compact ultrafast electron diffractometer, consisting of an s-band 1.6 cell photocathode radio-frequency gun, a multi-function changeable sample chamber, and a sensitive relativistic electron detector, was built at Shanghai Jiao Tong University. High-quality single-shot transmission electron diffraction patterns have been recorded by scattering 2.5 MeV electrons off single crystalline gold and polycrystalline aluminum samples. The high quality diffraction pattern indicates an excellent spatial resolution, with the ratio of the diffraction ring radius over the ring rms width beyond 10. The electron pulse width is estimated to be about 300 fs. The high temporal and spatial resolution may open new opportunities in various areas of sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-scale time-resolved electron diffraction: A case study in moiré materials

Ultrafast-optical-pump — structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying matter out of equilibrium. High-performance detectors are needed in scattering experiments to obtain maximum scientific value from every probe particle. Here we deploy a hybrid pixel array direct electron detector to perform ultrafast electron diffraction experiments on a WSe 2 /MoSe 2 2D heterobilayer, resolving the weak features of diffuse scattering and moiré superlattice structure without saturating the zero order peak. Enabled by the detector’s high frame rate, we show that a chopping technique provides diffraction difference images with signal-to-noise at the shot noise limit. Finally, we demonstrate that a fast detector frame rate coupled with a high repetition rate probe can provide continuous time resolution from femtoseconds to seconds, enabling us to perform a scanning ultrafast electron diffraction experiment that maps thermal transport in WSe 2 /MoSe 2 and resolves distinct diffusion mechanisms in space and time.

36 MATERIALS SCIENCE↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-angle Precession Electron Diffraction (MAPED): A Versatile Approach to 4D-STEM Precession

Precession of a converged beam during acquisition of a 4D-STEM dataset improves strain, orientation, and phase mapping accuracy by averaging over continuous angles of illumination. Precession experiments usually rely on integrated systems, where automatic alignments lead to fast, high-quality results. The dependence of these experiments on specific hardware and software is evident even when switching to nonintegrated detectors on a precession tool, as experimental set-up becomes challenging and time-consuming. Here, we introduce multi-angle precession electron diffraction (MAPED): a method to perform electron diffraction by collecting sequential 4D-STEM scans at different incident beam tilts. The multiple diffraction datasets are averaged together postacquisition, resulting in a single dataset that minimizes the impact of the curvature and orientation of the Ewald sphere relative to the crystal under study. Our results demonstrate that even four additional tilts improved measurement of material properties, namely strain and orientation, as compared to single-tilt 4D-STEM experiments. We show the versatility and flexibility of our MAPED approach with data collected on a number of microscopes with different hardware configurations and a variety of detectors.

4D-STEM↗

A compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction

We have developed a compact streak camera suitable for measuring the duration of highly charged subrelativistic femtosecond electron bunches with an energy bandwidth in the order of 0.1%, as frequently used in ultrafast electron diffraction (UED) experiments for the investigation of ultrafast structural dynamics. The device operates in accumulation mode with 50 fs shot-to-shot timing jitter, and at a 30 keV electron energy, the full width at half maximum temporal resolution is 150 fs. Measured durations of pulses from our UED gun agree well with the predictions from the detailed charged particle trajectory simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photodissociation of aqueous I3− observed with liquid-phase ultrafast mega-electron-volt electron diffraction

Developing femtosecond resolution methods for directly observing structural dynamics is critical to understanding complex photochemical reaction mechanisms in solution. We have used two recent developments, ultrafast mega-electron-volt electron sources and vacuum compatible sub-micron thick liquid sheet jets, to enable liquid-phase ultrafast electron diffraction (LUED). We have demonstrated the viability of LUED by investigating the photodissociation of tri-iodide initiated with a 400 nm laser pulse. This has enabled the average speed of the bond expansion to be measured during the first 750 fs of dissociation and the geminate recombination to be directly captured on the picosecond time scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precession electron diffraction for SiC grain boundary characterization in unirradiated TRISO fuel

Precession electron diffraction (PED), a transmission electron microscopy-based technique, has been evaluated for the suitability for evaluating grain boundary character in the SiC layer of tristructural isotropic (TRISO) fuel. Although the ultimate goal is to determine the grain boundary characteristics of fission product containing grain boundaries of neutron irradiated SiC, our work reports the effect of transmission electron microscope (TEM) lamella thickness on quality of data and establishes a baseline comparison on grain boundary characteristics determined previously using a conventional EBSD scanning electron microscope (SEM) based technique. In general, it was determined that the lamella thickness produced using the standard FIB fabrication process, is sufficient to provide reliable PED measurements with thicker lamellae (~120 nm) produce higher quality orientation data. Analysis of grain boundary character from the TEM-based PED data showed a much lower fraction of low angle grain boundaries compared to SEM-based EBSD data from the SiC layer of the same TRISO-coated particle as well as a SiC layer deposited at a slightly lower temperature. The fractions of high angle and CSL-related grain boundaries determined by PED are similar to those found using SEM-based EBSD. Since the grain size of the SiC layer of TRSIO fuel can be as small as 250 nm [12], depending on the fabrication parameters, and grain boundary fission product precipitates can be nano-sized, the TEM-based PED orientation data collection method is preferred to determine an accurate representation of the relative fractions of low angle, high angle and CSL-related grain boundaries. It was concluded that although the resolution of the PED data is better by more than an order of magnitude, data acquisition times may be significantly longer or the number of areas analyzed significantly larger than the SEM-based method to obtain a statistically relevant distribution. Also, grain size could be accurately determined but significantly larger analysis areas than those used in this study would be required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The UV Photoinduced Ring-Closing Reaction of Cyclopentadiene Probed with Ultrafast Electron Diffraction

Conjugated cyclic organic molecules are common across many fields such as pharmaceuticals, are naturally occurring in biological systems, and are used in synthetic materials. One particular area of interest from a photochemical point of view is the formation of highly strained cyclic organics. We investigate the photoinduced reaction of cyclopentadiene, a five-membered organic ring molecule which can form strained three and four carbon rings after photoexcitation with UV light, with the gas-phase ultrafast electron diffraction instrument at the SLAC MeV-UED facility. Electron diffraction offers a direct probe sensitive to the nuclear geometry during the reaction, allowing for the determination of the distribution of products formed following photoexcitation. We observe the simultaneous formation of the highly strained ring- closed bicyclo[2.1.0]pentene and vibrationally hot cyclopentadiene within the temporal resolution of the experiment, and determine the relative yield of all reaction products. Furthermore, the experimental results are in good agreement with the predictions of trajectory simulations.

Computational Chemistry↗

Improved temporal resolution in ultrafast electron diffraction measurements through THz compression and time-stamping

We present an experimental demonstration of ultrafast electron diffraction (UED) with THz-driven electron bunch compression and time-stamping that enables UED probes with improved temporal resolution. Through THz-driven longitudinal bunch compression, a compression factor of approximately four is achieved. Moreover, the time-of-arrival jitter between the compressed electron bunch and a pump laser pulse is suppressed by a factor of three. Simultaneously, the THz interaction imparts a transverse spatiotemporal correlation on the electron distribution, which we utilize to further enhance the precision of time-resolved UED measurements. We use this technique to probe single-crystal gold nanofilms and reveal transient oscillations in the THz near fields with a temporal resolution down to 50 fs. These oscillations were previously beyond reach in the absence of THz compression and time-stamping.

43 PARTICLE ACCELERATORS↗

Calculation of rf-induced temporal jitter in ultrafast electron diffraction

A significant contribution to the temporal resolution of an ultrafast electron diffraction (UED) instrument is arrival time jitter caused by amplitude and phase variation of radio-frequency (rf) cavities. In this paper, we present a semianalytical approach for calculating rf-induced temporal jitter from klystron and rf cavity parameters. Our approach allows fast estimation of temporal jitter for MeV-UED beamlines and can serve as a virtual timing tool when shot-to-shot measurements of rf amplitude and phase jitters are available. A simulation study for the SLAC MeV-UED instrument is presented, and the temporal resolution of several beamline configurations is compared.

47 OTHER INSTRUMENTATION↗

Mechanistic Insights into Superlattice Transformation at a Single Nanocrystal Level Using Nanobeam Electron Diffraction

Understanding the mechanism and ultimately directing nanocrystal (NC) superlattice assembly and attachment have important implications on future advances in this emerging field. Here, we use 4D-STEM to investigate a monolayer of PbS NCs at various stages of the transformation from a hexatic assembly to a nonconnected square-like superlattice over large fields of view. Maps of nanobeam electron diffraction patterns acquired with an electron microscope pixel array detector (EMPAD) offer unprecedented detail into the 3D crystallographic alignment of the polyhedral NCs. Our analysis reveals that superlattice transformation is dominated by translation of prealigned NCs strongly coupled along the <11n>AL direction and occurs stochastically and gradually throughout single grains. We validate the generality of the proposed mechanism by examining the structure of analogous PbSe NC assemblies using conventional transmission electron microscopy and selected area electron diffraction. Here, the experimental results presented here provide new mechanistic insights into NC self-assembly and oriented attachment.

36 MATERIALS SCIENCE↗

Non-destructive assessment of the polarity of GaN nanowire ensembles using low-energy electron diffraction and x-ray photoelectron diffraction

We investigate GaN nanowire ensembles spontaneously formed in plasma-assisted molecular beam epitaxy by non-destructive low-energy electron diffraction (LEED) and x-ray photoelectron diffraction (XPD). We show that GaN nanowire ensembles prepared on AlN-buffered 6H-SiC(0001{sup ¯}) substrates with well-defined N polarity exhibit similar LEED intensity-voltage curves and angular distribution of photo-emitted electrons as N-polar free-standing GaN layers. Therefore, as in the case of GaN layers, LEED and XPD are found to be suitable techniques to assess the polarity of GaN nanowire ensembles on a macroscopic scale. The analysis of GaN nanowire ensembles prepared on bare Si(111) allows us to conclude that, on this non-polar substrate, the majority of nanowires is also N-polar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗