Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron Beam Modeling and Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron- and light-induced stimulated Raman spectroscopy for nanoscale molecular mapping

We propose and theoretically analyze a new vibrational spectroscopy, termed electron- and light-induced stimulated Raman (ELISR) scattering, that combines the high spatial resolution of elec-tron microscopy with the molecular sensitivity of surface-enhanced Raman spectroscopy. WithELISR, electron-beam excitation of plasmonic nanoparticles is utilized as a spectrally-broadband butspatially-confined Stokes beam in the presence of a diffraction-limited pump laser. To characterizethis technique, we develop a numerical model and conduct full-field electromagnetic simulations toinvestigate two distinct nanoparticle geometries, nanorods and nanospheres, coated with a Raman-active material. Our results show the significant (10 6 -10 7 ) stimulated Raman enhancement that isachieved with dual electron and optical excitation of thesenanoparticle geometries. Importantly,the spatial resolution of this vibrational spectroscopy for electron microscopy is solely determinedby the nanoparticle geometry and the plasmon mode volume. Our results highlight the promiseof ELISR for simultaneous high-resolution electron microscopy with sub-diffraction-limited Ramanspectroscopy, complementing advances in superresolutionmicroscopy, correlated light and electronmicroscopy, and vibrational electron energy loss spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrotastic Solitary Waves (ESW) in the magnetotail: BEN wave forms observed by GEOTAIL

Wave forms of BEN (Broadband Electrostatic Noise) in the geomagnetic tail were first detected by the Wave Form Capture reciever on the GEOTAIL spacecraft. The results show that most of the BEN in the plasma sheet boundary layer (PSBL) are not continuous broadband noise but are composed of a series of solitary pulses having a special form which we term 'Electrostatic Solitary Waves (ESW)'. A nonlinear BGK potential model is proposed as the generation mechanism for the ESW based upon a simple particle simulation which considers the highly nonlinear evolution of the electron beam instability. The wave forms produced by this simulation are very similar to those observed by GEOTAIL and suggest that the nonlinear dynamics of the electron beam play an essential role in the generation of ESW.

Matsumoto, H.↗

Charge lifetime improvement of the Continuous Electron Beam Accelerator Facility photogun with a biased anode

GaAs photocathodes in dc high-voltage photoguns are highly susceptible to ion back-bombardment, which reduces the photocathode quantum efficiency and limits the useful operating lifetime for producing polarized electron beams. This paper demonstrates that applying a small positive bias to the photogun anode can significantly suppress ion back-bombardment and increase charge lifetime. This technique was studied extensively using the Continuous Electron Beam Accelerator Facility photogun, where highly polarized electron beams created using a strained-superlattice GaAs / GaAsP photocathode were used and charge lifetimes improved by almost a factor of 2. A new simulation code was developed to model ion production and tracking in order to better understand and explain the factors that led to the performance improvement. Results of the experiments and simulations are discussed in detail. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Laser Plasma Interaction in the MG Magnetic Field (Final Report)

Strong magnetic fields change properties of plasma. Employment of the magnetic fields can improve conditions for inertial confinement fusion. Compression and heating of the magnetized plasma is a base of the MagLIF pulsed power approach to the controlled fusion. Study of expansion and heating of plasma in the external magnetic fields, development of plasma instabilities, parametric and other effects are important for basic physics and applications. The main goal of the research for the grant was experimental investigation of laser produced plasma in the well characterized and controlled MG magnetic fields. We developed a platform for investigation of high intensity laser-plasma interaction (LPI) in the MG fields using a university-scale pulsed power machine. A Zebra machine at UNR generated transverse magnetic fields of 3 MG on the surface of the rod load and longitudinal fields of 1.4 MG in the coil loads. The magnetic fields were characterized with two-color Faraday rotation diagnostics. The pulsed power machine provided almost static magnetic fields for LPI compared to the much faster laser driven magnetic fields. We found that eddy currents in the rising magnetic field generate plasma on the metal targets. Eddy currents did not impact Si and CH dielectric targets. A Leopard laser with intensity in the focus up to 10 19 W/cm 2 produced plasma in the MG magnetic fields. The modified reflected Faraday diagnostics was used to study laser driven B-field at the MTW laser at Laboratory for Laser Energetics, UR. We demonstrated a slow dependence of the magnetic field in the coil on the applied laser intensity. The magnetic field increased by a factor of 2 if laser intensity increased by a factor of 30. This scaling is important for comparison of experiments at different laser facilities. Expansion of the plasma in the 2-3 MG external B-field was studied. Laser-produced plasma in the azimuthal magnetic field took the unique form of a thin disc expanding radially with a velocity of 250 km/s and confined in the vertical direction. A HYDRA MHD program at the University of Rochester was applied for simulations of LPI in the magnetic field B >3 MG. Simulations for the plasma disc parameters and the expansion dynamics were in a good agreement with experiments. Generation of narrow dense plasma jets in the longitudinal magnetic field of 0.6-0.8 MG was studied. Narrow plasma jets reached a length of 3-4 mm with the electron plasma density of (0.2-1.2)x10 20 cm -3 . A jet tip propagated with the velocity of 160-200 km/s. MHD simulations showed a good agreement of the dynamics of the formation of plasma jets with experiments. These jets are relevant to astrophysical jets. Simulations of K-shell spectra of Si plasma was performed for LPI in the B-field. The laser prepulse generated plasma near the laser target. A PrismSPECT model with a MeV electron beam produced by the laser was used. The spectral modelling showed the increased plasma density by a factor by 2-3 in the magnetic field. This was in agreement with the observed dynamics of the plasma plume confined by the axial magnetic field. The two-plasmon decay was studied in the 2.5-3 MG transversal magnetic fields. Strong 2-3.5 nm spectral widening and a 2-4 nm shifts of “red” and “blue” 3/2ω 0 spectral components were observed. The large shift and widening exceed the expected temperature and magnetic shift. PIC simulations are performing to clarify physics of this effect. The experimental research program for the grant is completed. New plasma effects in the MG fields were studied at the university-scale pulsed power generator. Two graduate and two undergraduate UNR and UR students carried experiments at the Zebra generator, supported and developed plasma diagnostics, provided data processing, and performed MHD simulations of LPI in the strong magnetic field. Research results are published in 9 referred papers and presented in 12 conferences. Program manager: Kramer U. Akli; Collaborators: R. C. Mancini and H. Sawada, University of Nevada, Reno (UNR); R. Betti and A. V. Maximov, University of Rochester (UR).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray FEL linear accelerator design via start-to-end global optimization

An X-ray Free Electron Laser (FEL) prefers using an electron beam with low emittance, small energy spread, and a high core current to generate coherent radiation through an undulator. In order to attain such a high brightness beam, the linear accelerator beam dynamics design generally involves separate photoinjector optimization and linac optimization. In this paper, we propose a new beam dynamics design strategy based on global optimization with fast start-to-end simulations from the photocathode to the end of the accelerator. The new start-to-end model significantly reduces the simulation time and makes the global optimization practical. The global optimization method avoids the need to choose a single solution based on bunch length at the injector exit for the linac optimization and helps find the solution with unfavorable bunch length at the injector exit but better phase space distribution that can result in better final electron beam phase space distribution at the entrance of the undulator. Here, using the start-to-end global optimization, we showed in an application example, with a 100 pC beam that good transverse emittance and over kilo-Ampere final core current can be attained using a photoinjector that consists of a VHF gun and boosting RF cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

A Prototype Thick-Target Bremsstrahlung Model with Angularly-Dependent Emission in the MCNP6 ® Code

This document summarizes the current thick-target bremsstrahlung (TTB) model in MCNP and provides test results for an alternative implementation to improve the accuracy with reduced cost compared to full electron transport. It has been observed that the current TTB model produces inaccurate results in problems where the medium is thick with respect to electrons, but the photon distribution in the problem has a strong directionality. An example of such a simulation is detectors surrounding a metal target irradiated with a radiographic beam of high energy photons. The primary cause of this discrepancy is the current TTB method emits all bremsstrahlung photons in the same direction as the primary electron produced from each (γ, e ± ) interaction, leading to artificially forward peaked photon distributions for intermediate to high-energy incident photons. To improve the TTB model, we have implemented an angularly-dependent TTB model in a developer version of the MCNP6 ® code; for developers, this was done on the branch prototype/angular_ttb in the mcnp6 repo on bitbucket. The angularly-dependent TTB model accounts for the energy and scattering of electrons as they slow down in the current material, but does not sample the computationally expensive energy straggling, secondary electron events, and tracking electrons; this approach is significantly less computationally expensive than full electron transport and can be comparable to the original TTB method for problems with sufficiently complex materials and geometry. To evaluate the method, we have modeled a simple problem of a beam of 5 MeV photons incident on a sphere of plutonium surrounded by detectors at different deflection angles. For this problem, the angularly-dependent TTB produces a photon flux within 8.0% for a 90 degree deflection angle and 0.8% along the beam axis, as compared to the electron transport solution. This is an improvement compared to a 43% and 81% discrepancy with the original TTB method, respectively. The rest of this work includes the following: the first section details the current TTB treatment in MCNP, which has not been well documented elsewhere. Then, the modified TTB algorithm is detailed and the approximations compared to the condensed history algorithm are compared. Results are given comparing the two TTB methods to the condensed history transport algorithm. The appendix includes details for code developers on relevant electron transport implementation details and potential code improvements for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical simulation of the generation of electrostatic turbulence in the magnetotail

A two-dimensional plasma model is used to investigate the development of electrostatic turbulence in a magnetized plasma from plasma instabilities. The simulation consists of following the motion of 100,000 ions in their self-consistent electrostatic field. The electrons are treated as a constant neutralizing background. The instabilities modeled are driven by a ring-type velocity distribution and by interpenetrating ion beams in a time-variable magnetic field. Instability growth times are of the order of an ion gyroperiod in the case of the ring distribution and of the order of an ion plasma period in the case of the beam simulation. Maximum potential differences generated are of the order of the ion kinetic energies. These simulations demonstrate the cascade of wave energy to long wavelengths, thus showing the E x B turbulence can be generated from plasma microinstabilities. After the free energy feeding, the instabilities are exhausted, and wave energy at wavelengths less than an ion gyrodiameter decays quickly to equilibrium levels, while longer wavelength modes persist for much longer times. In one model with a time dependent, but spatially uniform, magnetic field the electric field energy at long wavelengths appeared to increase as a result of the increase of the magnetic field.

Swift, D. W.↗

Center for Tokamak Transients Simulations

The major goals for the Center for Tokamak Transients Simulations (CTTS) were to develop detailed numerical simulations of disruptive transients in tokamak experiments and to use them in theoretical studies of the thermal-quench (TQ) and current-quench (CQ) phases of disruption. The University of Wisconsin-Madison component of CTTS contributed relevant development for the NIMROD code (https://nimrodteam.org) and applied it to disruptions that involve global vertical displacement. Code-development contributions include boundary conditions that represent sheath effects which occur when tokamak plasma is in contact with the surrounding vessel wall during vertical displacement events (VDEs). We also implemented a reduced model of energetic runaway electrons (REs) to simulate the effect of these energetic electrons on the CQ phase of tokamak disruptions. Our computations of VDEs include 2D and 3D verification through benchmarks with two other widely used macroscale plasma simulation codes, M3D-C1 and JOREK. Over nonlinear evolution to the final termination of plasma current, the 2D simulation results on magnetic axis location, toroidal current, and halo current track each other well. With the 3D benchmark computation, all three codes found the same qualitative behavior of the asymmetric instabilities having increasing growth rate after contact with the wall, followed by nonlinear excitation of other toroidal harmonics. Our NIMROD computations for an idealized configuration show agreement with an analytical assessment by V. D. Pustovitov [Nucl. Fusion 55, 113032 (2015)] that the plasma and non-ideal wall remain in force-balance such that net forces only result from magnetic stresses over the outer surface of the wall. Our study of the influence of boundary conditions on VDEs shows that extended-MHD simulations of VDEs are sensitive to electron energy transport to the wall and that boundary conditions on flow are only significant to the extent that they influence the electron energy transport. Resistive-MHD NIMROD simulations of the tokamak discharges in the Madison Symmetric Torus show that magnetic perturbations of poloidal wavenumber m=3 lead to chaotic magnetic topology over the edge region, which helps deconfine energetic electrons. A second area of RE study shows that the coupled resistive MHD/reduced RE model reproduces the resistive-hose particle-beam instability. With respect to educational opportunities, this effort involved and supported four graduate students at the University of Wisconsin-Madison and one postdoctoral associate. The results of this study have been disseminated through journal publications, conference presentations, technical reports, and PhD dissertations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PIC code modeling of spacecraft charging potential during electron beam injection into a background of neutral gas and plasma, part 1

Injections of nonrelativistic electron beams from an isolated equipotential conductor into a uniform background of plasma and neutral gas were simulated using a 2-D electrostatic particle code. The ionization effects on spacecraft charging are examined by including interactions of electrons with neutral gas. The simulations show that the conductor charging potential decreases with increasing neutral background density due to the production of secondary electrons near the conductor surface. In the spacecraft wake, the background electrons accelerated towards the charged spacecraft produce an enhancement of secondary electrons and ions. Simulations run for longer times indicate that the spacecraft potential is further reduced and short wavelength beam-plasma oscillations appear. The results are applied to explain the spacecraft charging potential measured during the SEPAC experiments from Spacelab 1.

Koga, J. K.↗

Vlasov Simulation of Electrostatic Solitary Structures in Multi-Component Plasmas

Electrostatic solitary structures have been observed in the Earth's magnetosheath by the Cluster spacecraft. Recent theoretical work has suggested that these solitary structures are modeled by electron acoustic solitary waves existing in a four-component plasma system consisting of core electrons, two counter-streaming electron beams, and one species of background ions. In this paper, the excitation of electron acoustic waves and the formation of solitary structures are studied by means of a one-dimensional electrostatic Vlasov simulation. The present result first shows that either electron acoustic solitary waves with negative potential or electron phase-space holes with positive potential are excited in four-component plasma systems. However, these electrostatic solitary structures have longer duration times and higher wave amplitudes than the solitary structures observed in the magnetosheath. The result indicates that a high-speed and small free energy source may be needed as a fifth component. An additional simulation of a five-component plasma consisting of a stable four-component plasma and a weak electron beam shows the generation of small and fast electron phase-space holes by the bump-on-tail instability. The physical properties of the small and fast electron phase-space holes are very similar to those obtained by the previous theoretical analysis. The amplitude and duration time of solitary structures in the simulation are also in agreement with the Cluster observation.

magnetohydrodynamics (MHD)↗

Soft X-ray emission from electron-beam-heated solar flares

Using time-dependent numerical simulations and Solar Maximum Mission observations of a solar flare on 1985 January 23, a study is conducted of the ability of an electron-beam-heating model to reproduce the rise phase of a flare as observed in soft X-ray lines of Ca XIX. The electron beam is parameterized by a peak flux, a low-energy cutoff, and a spectral index, and has a time dependence similar to the observed hard X-ray burst. For a spectral index of 6, only models with a low-energy cutoff of 20 keV reproduce the observed peak emission in the Ca XIX line complex. All models with a low-energy cutoff of 15 keV produce too much emission, while all models with a 25-keV cutoff too little emission. None of the models reproduces the temporal behavior of the soft X-ray emission. The electron-beam-heated component is theorized to only represent a small fraction of the energy released in the impulsive phase of this flare.

Mariska, John T.↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

Source record↗

Theory and Simulation of Ultrafast Multidimensional Nonlinear X-ray Spectroscopy of Molecules (Final Report)

Emerging X-ray free electron laser (XFEL) beam sources offer new types of probes of matter with unprecedented spatial and temporal resolutions. These experimental advances must be met by robust theoretical and computational tools that provide predictive modeling capacity of the underlining electronic and structural dynamics. The latter will be essential for the design of sophisticated multi-pulse experiments and for their interpretation. The proposed research effort will focus on developing cutting- edge simulation tools for nonlinear multidimensional X-ray/optical spectroscopies and aims to address key questions in Priority Research Opportunities 1 (Probing and controlling electron motion within a molecule) and 3 (Capturing rare events and intermediate states in the transformation of matter) as mentioned in the BES Roundtable Report “Opportunities for Basic Research at the Frontiers of XFEL Ultrafast Science”. XFEL multidimensional nonlinear techniques, which combine sequences of X-ray and possibly optical pulses, provide a unique experimental toolbox for probing the dynamics of core and valence electronic excitations, as well as material structure. Predictive modeling of these dynamical processes requires the combination of analytical theory for nonlinear interactions of light and matter, robust quantum-chemical methodologies for the accurate description of electronic structure of various materials, and multiscale ab initio electron and nuclear dynamics techniques operating beyond Born-Oppenheimer approximation. These challenges will be addressed with three research thrusts (i) Develop and implement theoretical apparatus for modeling a broad range of multidimensional spectroscopic techniques enabled by present and upcoming XFEL facilities. This thrust also includes the incorporation of a computational module in the DOE supported open-source NWChem computational chemistry package as well as the development of other open-source codes ready for dissemination across a broad user base; (ii) Propose and design new multi-pulse experiments that make use of the capabilities of the incoming LCLS-II facility; (iii) Perform selected applications to specific molecular systems that can be carried out at LCLS-II and demonstrate how these X-ray sources may be used to study nonadiabatic dynamics through conical interactions, electronic correlations in multi-core excitons, and charge transfer/energy transfer processes. The proposed research will be carried out by a multi-disciplinary four-institution research team which combines academia and national laboratories and spans the broad and necessary expertise in theoretical spectroscopy, nonlinear optics, quantum chemistry, molecular non-adiabatic dynamics and code development. The work will be performed in a highly interactive team environment with junior researchers shared between institutions thus cementing cross- disciplinary interactions. The developed simulation tools will be immediately deployed for XFEL facility users, both experimentalists and theorists, via freely distributed codes and databases. Altogether, this project will facilitate establishing XFEL-based multidimensional spectroscopies as a novel diagnostic tool for monitoring electronic and structural dynamics in molecular materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photon-rejection power of the Light Dark Matter eXperiment in an 8 GeV beam

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment designed to achieve comprehensive model independent sensitivity to dark matter particles in the sub-GeV mass region. An upgrade to the LCLS-II accelerator will increase the beam energy available to LDMX from 4 to 8 GeV. Using detailed GEANT4-based simulations, we investigate the effect of the increased beam energy on the capabilities to separate signal and background, and demonstrate that the veto methodology developed for 4 GeV successfully rejects photon-induced backgrounds for at least 2 × 10 14 electrons on target at 8 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially dependent modeling and simulation of runaway electron mitigation in DIII-D

New simulations with the Kinetic Orbit Runaway electron (RE) Code (KORC) show RE deconfinement losses to the wall during plasma scrape off are the primary current dissipation mechanism in DIII-D experiments with high-Z impurity injection, and not collisional slowing down. The majority of simulations also exhibit an increase in the RE beam energy due to acceleration by the induced toroidal electric field, even while the RE beam current is decreasing. In this study, KORC integrates RE orbits using the relativistic guiding center equations of motion and incorporates time-sequenced, experimental reconstructions of the magnetic and electric fields and line integrated electron density to construct spatiotemporal models of electron and partially ionized impurity transport in the companion plasma. Comparisons of experimental current evolution and KORC results demonstrate the importance of including Coulomb collisions with partially ionized impurity physics, initial RE energy, pitch angle, and spatial distributions, and spatiotemporal electron and partially ionized impurity transport. The research presented here provides an initial quantification of the efficacy of RE mitigation via injected impurities and identification of the critical role played by loss of confinement due to plasma scrape off on the inner wall as compared to the relatively slow collisional damping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗