Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electromagnetic calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Neutral Pion Electroproduction and development of a Neutral Particle Spectrometer

Protons and neutrons, i.e. nucleons, are the basic building blocks of the matter in the visible universe. The strong force binds the nucleons to form nuclei. The electromagnetic force forms the atoms by binding the electrons with the nuclei. The electromagnetic interaction is well understood by Quantum Electrodynamics (QED), which shows the most precise predictability amongst all the theories in physics. In QED, charges interact with each other by exchanging photons. The Quantum Chromodynamics (QCD) describes the strong interaction. Its degrees of freedom are quarks and gluons, the fundamental constituents of the nucleons. The quarks interact with each other by exchanging gluons. However, unlike QED, the gluons interact amongst themselves. This feature of self bindings of the gluons confines the quarks and gluons in the nucleons/hadrons, never to be seen as free. In order to study some of the features of QCD, such as confinement or the structure of the nucleon, one usually needs to rely on experiments. Electromagnetic probes, governed by the well-understood QED, are excellent tools to probe the nucleon. In general, different scales, e.g. electron beam energies, probe different regions of the nucleon. At low energy, of the order of a few GeV, the electron probes the nucleon in the valence quark region. As its energy increases, the electron probes the sea quark and gluon regions. The study of the nucleon structure in all these regions is needed to fully understand QCD. Form factors and parton distribution functions measured from elastic scattering and deep inelastic scattering of leptons off nucleons have provided a partial view of the internal structure of the nucleon. In the mid-1990s, Generalized Parton Distributions (GPDs) were developed. These new objects are a generalization of the form factors and parton distribution functions, but contain richer information on the nucleon internal structure. GPDs are accessible experimentally by deep exclusive reactions. Deeply virtual Compton scattering (DVCS) and deeply virtual meson production (DVMP) are some examples. The first dedicated DVCS/DVMP experiment took place in 2004 in Hall A at The Thomas Jefferson National Accelerator Facility, i.e. Jefferson Lab, in Virginia, U.S.A. A new DVCS/DVMP experiment, after the beam energy upgrade of Jefferson Lab, was carried out in Hall A in a wider kinematic range. Its data were taken from 2014 to 2016. In Hall C at Jefferson Lab, the next DVCS/DVMP experiment will take place. The Hall C experiment will further exploit the kinematic range with higher precision. A Neutral Particle Spectrometer (NPS) is in development to measure DVCS/DVMP events under high background conditions. Jefferson Lab will provide the highest precision data in the valence quark region for various exclusive reactions. The Electron-Ion Collider (EIC) is a future experimental facility currently planned to start operations around 2030 in the U.S.A. Its high energy and high luminosity will probe the sea quark and gluon regions providing answers to the outstanding questions of QCD, in particular in the region where matter is dominated by gluons. First of all, this document describes the data analysis and results of the Hall A neutral pion electroproduction off the proton, from the data taken in 2014-2016. Later, some of the developments towards the construction of the electromagnetic calorimeter of the NPS for the upcoming DVCS/DVMP experiment in Hall C are presented. Finally, one of the candidate materials for the EIC calorimeter, a glass scintillator, will be briefly introduced. I have participated to all these projects, in collaboration with many colleagues. I present in this thesis my contributions to each of these projects. My contributions to the neutral pion data analysis were focused on background subtractions on the calorimeter, acceptance calculations, and the estimation of the systematic uncertainty associated to the event selection cuts. Some necessary information on calibrations of the detectors and data analysis methods are also described. In the NPS project, I performed background dose calculations and energy and position resolution studies of the calorimeter, all using Monte Carlo simulations, with realistic geometries of the experimental apparatus. Characterization of the crystals of the calorimeter was also done. Additionally, I measured the radiation hardness of some glass scintillator in its early stage of development. In order to have a future reference when the glass calorimeter prototype will be tested, I simulated the energy resolution of the prototype.

Ko, Ho-San↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Studying the hadron structure with PANDA and CLAS using machine learning techniques

The hadron spectroscopy and structure are currently very active fields of research to study the non-perturbative regime of quantum chronodynamics. The first one studies the complex structure of excited hadrons by looking at their decay products, while the latter uses lepton scattering on nucleons. Both methods require reconstruction algorithms with great efficiency and good particle identification and background rejection rates. This work aims to provide these by either improving the existing methods or developing new ones. The first part of this document presents a feasibility study of a predicted hybrid charmonium state for the PANDA experiment. Lattice QCD calculations predict the ground state hybrid charmonium to be a spin exotic with quantum numbers of JP C = 1?+ at a mass of around 4.3 GeV with a width to be around 20 MeV. A machine learning based data analysis scheme is proposed to further improve the signal efficiency and the background reduction, alongside with improvements of the analysis software (PandaRoot), that are vital for this study. These improvements include a reworked clustering algorithm for the electromagnetic calorimeter (EMC) and an optimized monte carlo matching for neutral particles. The second part of this document is about studying the proton structure. A multidimensional study of the structure function ratio Fsin(?)LU /FUU has been performed for K±, based on the measurement of beam-spin asymmetries. It uses the high statistics data recorded with the CLAS12 spectrometer at Jefferson Laboratory. Fsin(?)LU is a twist-3 quantity that provides information about the quark gluon correlations in the proton. This document will present for the first time a simultaneous analysis of two kaon channels over a large kinematic range of z, xB , PT and Q2 with virtualities Q2 ranging from 1 GeV2 up to 8 GeV2 using machine learning techniques for improved particle identification.

Kripko, Aron↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nucleon Structure Studies at Jefferson Lab and the Electron Ion Collider

The research programs of Thomas Jefferson Laboratory (JLab) and the future Electron- Ion Collider (EIC) focus on one of the main goals of strong interaction studies : understanding the structure of nucleons in terms of the quarks and gluons composing them. Their structure is encoded in functions such as Generalized Parton Distributions (GPDs), which describe how quarks and gluons’ transverse position and longitudinal momentum are distributed inside nucleons. GPDs allow to obtain three-dimensional pictures of nucleons and to understand some of their fundamental properties, such as their internal pressure or the emergence of their spin from the dynamics of the partons composing them. At JLab and the EIC, electron beams are used to probe nucleons. Measurement of reactions such as Deeply Virtual Compton Scattering (DVCS) allows access to GPDs. The first longitudinally polarized-target experiment of the CLAS12 program at Jlab took place in 2022-2023. Combining polarized electron beams and nucleon targets, this experiment offers unique access to observables that allow the measurement of different types of GPDs. In particular, the DVCS beam- and target-spin asymmetries for protons and neutrons in deuterium will be measured for the first time. They give access to kinds of GPDs that are still poorly known, and the comparison between proton and neutron data will allow the extraction of the flavor dependence of the structure of nucleons. Specific analysis methods have been implemented to work with a polarized nuclear target and are presented in this thesis. These methods allow to obtain preliminary results for the asymmetries, waiting for the complete statistics to be available. In the long term, the experimental program for the EIC has been established with a strong emphasis on the measurement of the structure of nucleons at high energy. Measurements of reactions such as DVCS impose strict requirements on the electromagnetic calorimeter that will allow to measure the energy of the scattered electrons and photons. This calorimeter, which is under development, will be based on scintillating crystals read by Silicon Photomultipliers (SiPMs). A new type of glass-based scintillating material was tested, evaluating the possibilities to meet the technical requirements concerning their light yield and resistance to radiation damage in particular. Several models of SiPMs have been characterized, demonstrating they can operate over the vast energy range necessary to address the physics case at the EIC and providing guidelines for developing their readout electronics.

Pilleux, Noemie↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the anomalous precession frequency in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low energy observable that can be both measured and computed with high precision, therefore it can provide an important test of the Standard Model and it is a sensitive probe for new physics. In particular, any discrepancy between the experimental value and the theoretical prediction can be due to Beyond Standard Model physics contribution. The E989 Muon $g-2$ Experiment at Fermilab aims to measure $a_\mu$ with a precision of 140 parts per billion, four time more precisely than the previous experiment at Brookhaven National Laboratory (BNL). E989 seeks to either resolve or confirm the observed discrepancy of $3.7\sigma$ between the Standard Model value and the experimental one. The $a_\mu$ measurement requires a precise determination of both the muon spin anomalous precession frequency and the average magnetic field seen by the muons as they circulate in a storage ring. The anomalous precession frequency measurement is b ased on the time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters placed around the inner circumference of the ring, while the magnetic field is constantly monitored by NMR probes. Last spring, E989 has published a new measurement of $a_\mu$ from the 2018 data-taking campaign, confirming the previous BNL value with comparable precision, bringing the discrepancy with the theoretical value to $4.2\sigma$. The candidate worked on the measurement of the anomalous precession frequency and on the estimate of the related systematic uncertainties of the 2018 data, giving an important contribution to the data analysis. The result presented in chapters 4 and 5 of this dissertation was included, among three other analyses, to determine the estimate of the anomalous magnetic moment by the Muon g-2 experiment. This work will present the anomalous precession frequency analysis technique and its result, the related systematics and finally the latest $a_\mu$ result.

Sorbara, Matteo↗

Melting LHC detectors: a novel search for stopped long-lived particles

Particles at the TeV scale with lifetimes of a year or longer could have been abundantly produced at the LHC yet escaped detection because of backgrounds, and could still be trapped within detector materials. With gluinos in split-supersymmetry as a working example, we show that these trapped particles can be recovered from detector materials once prepared in liquid form, for example, by melting silicon detectors, extracting liquid argon from the electromagnetic calorimeter, or constructing a large water pool near ATLAS or CMS. These liquid samples can then be processed using iterative centrifugation followed by mass spectrometry, enabling single-particle sensitivity in macroscopic samples. This method can potentially discover gluinos up to 3 TeV in mass at the HL-LHC. It can also improve upon existing limits for other long-lived particles. For example, it can discover the stop up to 2 TeV, and will also be sensitive to integer-charged particles in the TeV range.

Gonski, Julia L. [SLAC]↗

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Measurement of the muon anomalous precession frequency in Runs 4, 5, and 6 of the Muon g-2 experiment at Fermilab

The Fermilab E989 Muon g − 2 experiment measures the muon’s anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon’s cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the g − 2 storage ring. Spin precession frequency is extracted from the time distribution of the muon’s decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon’s anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world’s most precise measurement of the muon’s anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

Development of an MCP-Based Timing Layer for the LHCb ECAL Upgrade-2

The increase in instantaneous luminosity during the high-luminosity phase of the LHC represents a significant challenge for future detectors. A strategy to cope with high-pileup conditions is to add a fourth dimension to the measurements of the hits, by exploiting the time separation of the various proton–proton primary collisions. According to LHCb simulation studies, resolutions of about 10–20 picoseconds, at least an order of magnitude shorter than the average time span between primary interactions, would be greatly beneficial for the physics reach of the experiment. Microchannel plate (MCP) photomultipliers are compact devices capable of measuring the arrival time of charged particles with the required resolution. The technology of large-area picosecond photodetectors (LAPPDs) is under investigation to implement a timing layer that can be placed within a sampling calorimeter module with the purpose of measuring the arrival time of electromagnetic showers. LAPPD performances, using a Gen-I tile with a delay-line anode and a Gen-II with a capacitively coupled anode, have been measured thoroughly both with laser (wavelength of 405 nm and pulse width of 27.5 ps FWHM) and high-energy electron (1–5.8 GeV) beams. Time resolutions of the order of 30 ps for single photoelectrons and 15 ps for electromagnetic showers initiated by 5-GeV electrons, as measured at the shower maximum, are obtained.

47 OTHER INSTRUMENTATION↗

Denoising diffusion models with geometry adaptation for high fidelity calorimeter simulation

Simulation is crucial for all aspects of collider data analysis, but the available computing budget in the High Luminosity LHC era will be severely constrained. Generative machine learning models may act as surrogates to replace physics-based full simulation of particle detectors, and diffusion models have recently emerged as the state of the art for other generative tasks. Here, we introduce CaloDiffusion, a denoising diffusion model trained on the public CaloChallenge datasets to generate calorimeter showers. Our algorithm employs 3D cylindrical convolutions, which take advantage of symmetries of the underlying data representation. To handle irregular detector geometries, we augment the diffusion model with a new geometry latent mapping (GLaM) layer to learn forward and reverse transformations to a regular geometry that is suitable for cylindrical convolutions. The showers generated by our approach are nearly indistinguishable from the full simulation, as measured by several different metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating accurate simulations of calorimeter showers with normalizing flows and probability density distillation

Recently, we introduced caloflow, a high-fidelity generative model for GEANT4 calorimeter shower emulation based on normalizing flows. Here, we present caloflow v2, an improvement on our original framework that speeds up shower generation by a further factor of 500 relative to the original. The improvement is based on a technique called probability density distillation, originally developed for speech synthesis in the machine learning literature, and which we develop further by introducing a set of powerful new loss terms. We demonstrate that caloflow v2 preserves the same high fidelity as the original using qualitative (average images, histograms of high-level features) and quantitative (classifier metric between geant4 and generated samples) measures. The result is a generative model for calorimeter showers that matches the state of the art in speed (a factor of 10 4 faster than GEANT4) and greatly surpasses the previous state of the art in fidelity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, construction and commissioning of a technological prototype of a highly granular SiPM-on-tile scintillator-steel hadronic calorimeter

The CALICE collaboration is developing highly granular electromagnetic and hadronic calorimeters for detectors at future energy frontier electron-positron colliders. After successful tests of a physics prototype, a technological prototype of the Analog Hadron Calorimeter has been built, based on a design and construction techniques scalable to a collider detector. The prototype consists of a steel absorber structure and active layers of small scintillator tiles that are individually read out by directly coupled SiPMs. Each layer has an active area of 72 × 72 cm^2 and a tile size of 3 × 3 cm^2. With 38 active layers, the prototype has nearly 22,000 readout channels, and its total thickness amounts to 4.4 nuclear interaction lengths. The dedicated readout electronics provide time stamping of each hit with an expected resolution of about 1 ns. The prototype was constructed in 2017 and commissioned in beam tests at DESY. It recorded muons, hadron showers and electron showers at different energies in test beams at CERN in 2018. In this paper, the design of the prototype, its construction and commissioning are described. The methods used to calibrate the detector are detailed, and the performance achieved in terms of uniformity and stability is presented.

47 OTHER INSTRUMENTATION↗

Fast and accurate simulations of calorimeter showers with normalizing flows

In this study, we introduce caloflow, a fast detector simulation framework based on normalizing flows. For the first time, we demonstrate that normalizing flows can reproduce many-channel calorimeter showers with extremely high fidelity, providing a fresh alternative to computationally expensive geant4 simulations, as well as other state-of-the-art fast simulation frameworks based on generative adversarial networks (GANs) or variational autoencoders (VAEs). In addition to the usual histograms of physical features and images of calorimeter showers, we introduce a new metric for judging the quality of generative modeling: the performance of a classifier trained to differentiate real from generated images. We show that GAN-generated images can be identified by the classifier with nearly 100% accuracy, while images generated from caloflow are better able to fool the classifier. More broadly, normalizing flows offer several advantages compared to other state-of-the-art approaches (GANs and VAEs), including tractable likelihoods, stable and convergent training, and principled model selection. Normalizing flows also provide a bijective mapping between data and the latent space, which could have other applications beyond simulation, for example, to detector unfolding.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large-area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-β decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work, we showcase light detectors based on an alternative Ir-Pt bilayer transition-edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of < 100 eV rms. Our detectors have risetimes of approximately 180μs and measured timing jitter of < 20μs for the expected signal to noise at the Q value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-β decay pile-up events. In conclusion, the current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗