Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrify”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Tutorial: Electrified Aircraft Propulsion Approaches for Modeling and Electrical Hardware-in-the-Loop Testing

This tutorial session outlines capabilities made available by the National Aeronautics and Space Administration for testing electrified aircraft propulsion (EAP) hardware and software prior to using turbomachinery. Removing these components from the experimentation process until necessary significantly reduces the development and testing costs and safety risks. Three facilities, the NASA Electric Aircraft Testbed (NEAT) and the Hybrid Propulsion Emulation Rig (HyPER) are unique facilities that provide the following capabilities: (i) the verification of megawatt-scale electrical and electromechanical system components at altitude, (ii) the verification of EAP control systems on sub-scale representative electromechanical architectures. The importance, operation, and specifications of each facility is described with detail. Provided examples of past testing showcase the abilities of each facility. Simple and complex methods for replicating the steady state and dynamical mechanical loading on the electrical power system are discussed

Electrified Aircraft Propulsion↗

Simulating competition in the US bioeconomy to produce hard‐to‐electrify transportation fuels using limited biomass resources

This study presents a novel bioeconomy optimization framework, BiOpt, designed to address critical questions regarding the strategic use of limited US biomass resources for biofuel production. By integrating detailed techno-economic analyses, life cycle assessments, and resource assessment data, BiOpt optimizes resource distributions across competing technologies to maximize economic performance and/or minimize greenhouse gas emissions. Using feedstock scenarios from the 2023 Billion Ton Study, the analysis explores optimal biomass allocations across sustainable aviation fuel, diesel, and marine biofuel conversion pathways given varying production targets and policy incentives. Results demonstrate distinct feedstock preferences and pathway utilizations when prioritizing economic returns vs. emissions reductions. For instance, fats, oils, and greases were highly favored in cost-optimized scenarios, while low-carbon feedstocks such as wet waste dominated greenhouse gas-minimized strategies. The findings underscore the pivotal role of policy incentives and technological advances in shaping biofuel supply chains and provide actionable insights for scaling sustainable biofuel production to decarbonize hard-to-electrify sectors. This framework offers a robust tool for policymakers and stakeholders to evaluate biofuel strategies that balance energy output, economic viability, and environmental impact.

09 BIOMASS FUELS↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transition from Vehicular to Structural Ionic Transport in Electrified Alkali Aqueous Solutions

A molecular understanding of the solvation and dynamics of ions under static electric fields is crucial for modelling a wide range of natural and technological processes. Yet, traditional simulation methods suffer from a trade-off that has to be made between accuracy and statistical convergence. To bridge this gap, herein we extend our recently introduced Perturbed Neural Network Potential Molecular Dynamics (PNNP MD) approach to investigate the solvation structures and ionic transport mechanisms of electrified alkali cationic solutions. We obtain ionic conductivities for Li+, Na+ and Cs+ from the field dependence of the ionic current density in good agreement with experiment. Surprisingly, the migration mechanism is found to be strikingly different for the three ions despite their similar ionic conductivities. While Li+ conducts predominantly through vehicular migration of a stable 4-fold coordinated ion at all field strengths, Cs+ conducts strictly through a structural diffusion mechanism, where 9-12 transient first shell water coordination bonds are broken and renewed. Notably, aqueous Na+ emerges as a “Goldilocks” ion: its ion-water interactions are strong enough to maintain distinct 5-6 fold coordination shells at zero field (unlike Cs+) yet labile enough to be strongly perturbed by electric fields (unlike Li+). As a consequence, we observe an electric field-induced transition from vehicular to structural ionic transport for Na+ that is accompanied by a marked increase in the ionic current density. Our results imply that the conductance mechanism of ions with moderate ion-solvent interactions can be effectively tuned by external electric fields.

Joll, Kit↗

Nano-Plasticity of an Electrified Ionic Liquid/Electrode Interface: Uncovering Hard–Soft Structuring via Controlled Metal Fill Factor

Here, ionic liquids (ILs) nanostructuring at electrified interfaces is of both fundamental and practical interest as these materials are increasingly gaining prominence in energy storage and conversion processes. However, much remains unresolved about IL potential-controlled (re)organization under highly polarized interfaces, mostly due to the difficulty of selectively probing both the distal and proximal surface layers of adsorbed ions. In this work, the structural dynamics of the innermost layer (<10 nm from the surface) were independently interrogated from that of the ionic layers in the sub-surface region (>100 nm from the surface), using an infrared (IR) spectroscopy approach. By tuning the metal fill factor of gold films deposited on conductive metal oxide-modified IR internal reflection elements, the charge-driven (re)structuring of the inner and distal layers of 1-butyl-1-methylpyrrolidinium trifluoromethanesulfonate is unveiled. Within a relatively wide potential region (~±1 V) bounding the potential of zero charges, the ionic liquid is shown to undergo a reversible (i.e., soft) reorganization whereby the innermost layer of anions (cations) is exchanged by a layer of cations (anions). Kinetically unhindered changes in the number density of constituent cations and anions largely follow electrostatic expectations in the subsurface region, whereas the innermost layer exhibits a pronounced hysteresis and very slow relaxation. Under larger negative potential bias, IL restructuring is characterized by a highly irreversible (i.e., hard) and intense interfacial densification of the BMPy + cations, consistent with the formation of nanoscale segregated liquids. The outcomes of this work reveal a plastic IL nanostructuring under a strong electric field.

36 MATERIALS SCIENCE↗

Interconnected nanoconfining pore networks enhance catalyst CO 2 interaction in electrified reactive capture

Systems that sequentially capture and upgrade CO 2 from air to fuels/fuel-intermediates, such as syngas and ethylene, rely on an energy-intensive CO 2 release process. Electrified reactive capture systems transform CO 2 obtained directly from carbonate capture liquid into products. Previous reactive capture systems show a decline in Faradaic efficiencies (FE) at current densities above 200 mA/cm 2 . Here we show the chemical origins of this problem, finding that prior electrocatalyst designs failed to arrest, activate, and reduce in situ-generated CO 2 (i-CO 2 ) before it traversed the catalyst layer and entered the tailgas stream. We develop a templated synthesis to define pore structures and the sites of Ni single atoms, and find that carbon-nitrogen-based nanopores are effective in accumulating i-CO 2 via short-range, non-electrostatic interactions between CO 2 molecules and the nanochannel walls. These interactions confine and enrich i-CO 2 within the pores, enhancing its binding and activation. We report as a result carbonate electrolysis at 300 mA/cm 2 with FE to CO of 50% ± 3%, and with <1% CO 2 in the tailgas outlet stream. This corresponds to a projected energy efficiency (EE) to 2:1 syngas of 46% at 300 mA/cm 2 when H 2 is added using a water electrolyzer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Intensified atomic utilization efficiency of single-atom catalysts for nitrate conversion via electrified nanoporous membrane

Conventional electrochemical reactors for nitrate reduction typically suffer from limited reaction efficiency when applied for real-world water treatment due to poor utilization of electrocatalytic active sites. Here, we applied nanoporous electrofiltration to intensify atomic utilization by incorporating single-atom catalysts into an electrified membrane for reducing low-concentration nitrate to ammonia under realistic water conditions. We enhance the exposure of single atoms in nanopores by coating the catalysts on a carbon nanotube–interwoven membrane framework. Electrofiltration intensifies the transport and adsorption of nitrate in confined nanopores with highly exposed single-atom active sites to enhance reduction. The membrane enables a superior ammonia turnover frequency of 15.1 grams of nitrogen per gram of metal per hour, up to four orders of magnitude higher than that reported in the literature, under both high removal efficiency and Faradaic efficiency of over 86% when treating influents with a low nitrate concentration of 100 milligrams of nitrogen per liter in a residence time on the order of seconds.

Science & Technology - Other Topics↗

Dynamics of electrified liquid surface during plasma-liquid interaction

The research goal of this Department of Energy (DOE) Office of Fusion Energy Science (OFES) project was to investigate the electrified liquid surface dynamics using a shallow water model. The project was an extension of the Princeton Collaborative Research Facility (PCRF) project to work with Dr. Mikhail Shneider at Princeton University.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HOLISTIC ENERGY EFFICIENCY ANALYSIS OF ELECTRIFIED OFF-HIGHWAY MATERIAL HANDLER: FROM DRIVE CYCLE CHARACTERIZATION TO POWERTRAIN, HYDRAULIC, AND THERMAL SYSTEM PERFORMANCE

Three complexities surrounding the operation and testing of hybrid electric, heavy-duty nonroad machines have been addressed experimentally and using 1D simulation. Their resolutions have been intertwined with the development of a prototype machine that was proven to reduce fuel consumption in excess of 20%. A real-world drive cycle that leveraged hydraulic cylinder position was developed and utilized to ensure accurate reproduction of hydraulic work between the baseline and hybrid machines, while simultaneously maintaining less than 5% RMS error in position for main load handling functions. The newly developed, machine-specific drive cycle also contributed towards making equivalent comparisons in energy consumption between machine types through composite performance metrics that were extrapolated over a typical shift duration. Lastly, this work addressed thermal management energy consumption, a topic of increasing popularity when discussing electrified vehicles, by proposing a 1.4% energy savings through special mechanization and control of cooling system components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aircraft measurements of electrified clouds at Kennedy Space Center, part 3

Flights made by the Special Purpose Test Vehicle for Atmospheric Research (SPTVAR) airplane during a second deployment to Florida during the summer of 1989 are discussed. The findings based on the data gathered are presented. The progress made during the second year of the project is discussed. The summer 1989 study was carried out with the support and guidance of Col. John Madura, Commander of Detachment 11, 2nd Weather Squadron, USAF, at Patrick Air Force Base (PAFB) and Cape Canaveral Air Force Station. The project goals were to develop and demonstrate techniques for measuring the electric field aloft and locating regions of charge during flight within and near clouds; to characterize the electric conditions that are presently identified as a threat to space launch vehicles; and to study the correlation between the electric field aloft and that at Kennedy Space Center's ground-based electric field mill array for a variety of electrified clouds.

Jones, J. J.↗

Aircraft measurements of electrified clouds at Kennedy Space Center. Part 1: 1988 flights

During the fall of 1988, a Schweizer 845 airplane equipped to measure electric field and other meteorological parameters flew over Kennedy Space Center in a program to study clouds defined in the existing launch retriction requirements. The special purpose test vehicle for atmospheric research (SPTVAR) was suitable for flights through thunderclouds and was instrumented to measure all three components of the ambient electric vector. The main goals of the project were: (1) to develop and demonstrate techniques for measuring the electric field aloft and locate regions of charge during flight; (2) to characterize the electrical conditions within and near clouds that are presently identified as a threat to space launch vehicles; and (3) to study the correlation between the electric field aloft and that at Kennedy Space Center's ground-based field mill network for a variety of electrified clouds.

Jones, J. J.↗

Aircraft measurements of electrified clouds at Kennedy Space Center. Part 2: Case study: 4 November 1988 (88309)

During the fall of 1988, a Schweizer airplane equipped to measure electric field and other meteorological parameters flew over Kennedy Space Center (KSC) in a program to study clouds defined in the existing launch restriction criteria. A case study is presented of a single flight over KSC on November 4, 1988. This flight was chosen for two reasons: (1) the clouds were weakly electrified, and no lightning was reported during the flight; and (2) electric field mills in the surface array at KSC indicated field strengths greater than 3 kV/m, yet the aircraft flying directly over them at an altitude of 3.4 km above sea level measured field strengths of less than 1.6 kV/m. A weather summary, sounding description, record of cloud types, and an account of electric field measurements are included.

Jones, J. J.↗

Electrical emissions of airplanes flying in electrified clouds and their effect on airplane measurements of cloud electric fields

The signature of the cloud electric field components deduced from measurements made with electric field meters carried on airplane penetrating electrified clouds is often complex, especially when the airplane experiences strong electrical charging. However, simple electric field variations were obtained for penetrations involving severe charging of the airplane on flights over KSC on 19 Aug. 1989. During these episodes of severe electrical charging, the airplane typically became negatively charged as it approached a region of negative cloud charge and then became positively charged as it receded from the cloud charge. The charge acquired by the airplane within the cloud was so large that the electric fields at the faces of the mills mounted on the fuselage were as large as for an ambient electric field of 60 to 80 kV/m. However, the deduced electric field components perpendicular to the direction of flight, to which these mills respond, were only about 5 to 10 kV/m. The variation of the deduced ambient field component in the direction of flight was antisymmetric about the charge region for these penetrations. Analysis of these results suggest that intense plumes of electric charge were emitted from the airplane and that the electric field associated with these plumes overcame the electric field due to the cloud charge at the tail-mounted field mill. As a consequence, the deduced component of the ambient electric field in the direction of flight was severely distorted. These findings emphasize the need for careful evaluation of airplane electric field measurements and of the need for further work on techniques for improving the measurements.

Jones, James J.↗

Total Lightning Observations within Electrified Snowfall using Polarimetric Radar, LMA, and NLDN Measurements

Four electrified snowfall cases are examined using total lightning measurements from lightning mapping arrays (LMAs), and the National Lightning Detection Network (NLDN) from Huntsville, AL and Washington D.C. In each of these events, electrical activity was in conjunction with heavy snowfall rates, sometimes exceeding 5-8 cm hr-1. A combination of LMA, and NLDN data also indicate that many of these flashes initiated from tall communications towers and traveled over large horizontal distances. During events near Huntsville, AL, the Advanced Radar for Meteorological and Operational Research (ARMOR) C-band polarimetric radar was collecting range height indicators (RHIs) through regions of heavy snowfall. The combination of ARMOR polarimetric radar and VHF LMA observations suggested contiguous layer changes in height between sloping aggregate-dominated layers and horizontally-oriented crystals. These layers may have provided ideal conditions for the development of extensive regions of charge and resultant horizontal propagation of the lightning flashes over large distances.

Schultz, Christopher J.↗