Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Efficiency calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Model emulation and closure tests for (3+1)D relativistic heavy-ion collisions

In nuclear and particle physics, reconciling sophisticated simulations with experimental data is vital for understanding complex systems like the Quark Gluon Plasma (QGP) generated in heavy ion collisions. However, computational demands pose challenges, motivating using Gaussian Process emulators for efficient parameter extraction via Bayesian calibration. We conduct a comparative analysis of Gaussian Process emulators in heavy-ion physics to identify the most adept emulator for parameter extraction with minimal uncertainty. Furthermore, our study contributes to advancing computational techniques in heavy-ion physics, enhancing our ability to interpret experimental data and understand QGP properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A moderate-resolution, wide-band, astronomical echelle spectrograph

An echelle spectrograph is described which is specifically designed for use on a 52-in. f/7.6 telescope as an instrument optimally suited for studying spectra of the faint optical counterparts to X-ray stars at moderate spectral resolution. The spectrograph is also able to accomodate a two-dimensional photon-tagging panoramic image detector so that high-time-resolution studies of the spectra of variable stars can be carried out. The equations for echelle spectrographs are summarized, and some features of the present instrument are discussed. These include its prism cross-disperser, small elliptical flat mirror, and unusually high efficiency. An iron-argon calibration spectrum obtained by pressing the film against the output fiber optics of a three-stage electrostatically focused image intensifier, a spectrum of P Cygni taken by placing the film directly in the image plane of the spectrograph, and a photon-counted image of a small section of an echellogram produced during an observation of the Ring nebula in Lyra are provided to illustrate the performance of the instrument.

Bardas, D.↗

Measurements of antenna polar diagrams and efficiencies using a phase-switched interferometer

It is desirable to know antenna polar patterns and efficiencies accurately. In the past, calibration measurements have been made using balloons and aircraft and more recently satellites. These techniques are usually very expensive. It is shown that under certain circumstances it is possible to use a simpler and inexpensive technique by connecting together the antenna under test with another antenna to form a phase switched interferometer as first described by Ryle (1952). The technique does require a suitable radio source which gives measurable powers when using small antennas and since dipoles have broad patterns, radio sources with similar right ascensions but different declinations to the primary source can be a problem. These problems can partly be overcome by filtering the interference pattern.

Vincent, R. A.↗

Calibration of the Rosat High Resolution Imager (HRI)

The microchannel plate-based High Resolution Imager (HRI) is one of the focal plane instruments of the Rosat X-ray telescope that was launched on 1 June 1990. The calibration of the HRI is reported and preliminary results from the in-orbit calibration are presented. The quantum efficiency of the detector has been determined as a function of energy, the spatial variation of quantum efficiency, geometric nonlinearities, background, imaging performance, and UV sensitivity. Results of periodic tests of the temporal stability of the instrument are also reported.

Zombeck, M. V.↗

ATIC Flight Data Processing

The first flight of the Advanced Thin Ionization Calorimeter (ATIC) experiment from McMurdo, Antarctica lasted for 16 days, starting in December, 2000. The ATIC instrument consists of a fully active 320-crystal, 960-channel Bismuth Germanate (BGO) calorimeter, 202 scintillator strips in 3 hodoscopes interleaved with a graphite target, and a 4480-pixel silicon matrix charge detector. We have developed an Object Oriented data processing package based on ROOT. In this paper, we will describe the data processing scheme used in handling the accumulated 45 GB of flight data. We will also discuss trigger issues by comparing the measured energy-dependent trigger efficiency with its simulation and calibration issues by considering the time-dependence of housekeeping information, etc.

Ahn, H. S.↗

Background Acoustics Levels in the 9x15 Wind Tunnel and Linear Array Testing

The background noise level in the 9x15 foot wind tunnel at NASA Glenn has been documented, and the results compare favorably with historical measurements. A study of recessed microphone mounting techniques was also conducted, and a recessed cavity with a micronic wire mesh screen reduces hydrodynamic noise by around 10 dB. A three-microphone signal processing technique can provide additional benefit, rejecting up to 15 dB of noise contamination at some frequencies. The screen and cavity system offers considerable benefit to test efficiency, although there are additional calibration requirements.

Stephens, David↗

Study of Nuclear Structure Functions at Jefferson Lab

This thesis presents a study of nuclear modification of quark distributions (the EMC effect) using inclusive electron-scattering data from Jefferson Lab Hall C, with emphasis on experiment E12-10-008 (XEM2). The analysis spans nuclei from light to heavy targets and combines measurements at multiple spectrometer settings to constrain EMC ratios over a broad range in Bjorken-x and Q2. A complete analysis framework was developed to extract charge-normalized and efficiency-corrected yields, including detector calibrations, beam-current calibration, density-loss corrections for cryogenic targets, background subtraction, radiative and Coulomb corrections, and systematic studies. Instrumental cross-checks, including HMS–SHMS comparisons and reconstruction studies, show that residual spectrometer differences are predominantly multiplicative in the kinematic region relevant to the EMC analysis. The extracted EMC ratios are broadly consistent with previous measurements while extending coverage across many nuclei. The EMC slope increases from light to heavy nuclei and shows signs of saturation at large A. After accounting for the dominant A dependence, the results are consistent with no isospin dependence, but also consistent with the predicted modification from the isovector model.

Sharda, Abhyuday [Univ. of Tennessee, Knoxville, T↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Calibration of Axisymmetric and Quasi-1D Solvers for High Enthalpy Nozzles

The proposed paper will present a numerical investigation of the flow characteristics and boundary layer development in the nozzles of high enthalpy shock tunnel facilities used for hypersonic propulsion testing. The computed flow will be validated against existing experimental data. Pitot pressure data obtained at the entrance of the test cabin will be used to validate the numerical simulations. It is necessary to accurately model the facility nozzles in order to characterize the test article flow conditions. Initially the axisymmetric nozzle flow will be computed using a Navier Stokes solver for a range of reservoir conditions. The calculated solutions will be compared and calibrated against available experimental data from the DLR HEG piston-driven shock tunnel and the 16-inch shock tunnel at NASA Ames Research Center. The Reynolds number is assumed to be high enough at the throat that the boundary layer flow is assumed turbulent at this point downstream. The real gas affects will be examined. In high Mach number facilities the boundary layer is thick. Attempts will be made to correlate the boundary layer displacement thickness. The displacement thickness correlation will be used to calibrate the quasi-1D codes NENZF and LSENS in order to provide fast and efficient tools of characterizing the facility nozzles. The calibrated quasi-1D codes will be implemented to study the effects of chemistry and the flow condition variations at the test section due to small variations in the driver gas conditions.

Papadopoulos, P. E.↗

Performance of multilayer coated diffraction gratings in the EUV

The effect of multilayer coating application on the performance of a diffraction grating in the EUV spectral region was evaluated by examining the performance of a 3600-line/mm and a 1200-line/mm replica blazed gratings, designed for operation in the 300-A spectral region in first order. A ten-layer IrSi multilayer optimized for 304 A was deposited using electron-beam evaporation. The grating efficiency was measured on the SURF II calibration beamline in a chamber designed for calibrating the solar EUV rocket telescope and spectrograph multilayer coatings. A significant (by a factor of about 7) enhancement in grating efficiency in the 300-A region was demonstrated.

Keski-Kuha, Ritva A. M.↗

High Accuracy In-Flight Wavelength Calibration of Imaging Spectrometry Data

Accurate wavelength calibration of imaging spectrometer data is essential if proper atmospheric transmission corrections are to be made to obtain apparent surface reflectance. Accuracies of 0.1 nm are necessary for a 10 nm-sampling instrument in order to match the slopes of the deep atmospheric water vapor features that dominate the 0.7-2.3 micrometer regions. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is calibrated in the laboratory to determine the wavelength position and full-width-half-maximum (FWHM) response for each of the 224 channels. The accuracies are limited by the quality of the monochromator used as a source. The accuracies vary from plus or minus to plus or minus 1.5 nm depending on the wavelength region, in general decreasing with increasing wavelength. Green et al. make corrections to the wavelength calibrations by using the known positions of 14 atmospheric absorption features throughout the 0.4-2.5 micrometer wavelength region. These features, having varying width and intensity, were matched to the MODTRAN model with a non-linear least squares fitting algorithm. A complete calibration was developed for all 224 channels by interpolation. Instrument calibration cannot be assumed to be stable to 0.1 nm over a flight season given the rigors of thermal cycling and launch and landing loads. The upcoming sensor HYDICE will require a means for in-flight spectral calibration of each scene because the calibration is both temperature and pressure sensitive. In addition, any sensor using a two-dimensional array has the potential for systematic wavelength shifts as a function of cross-track position, commonly called 'smile'. Therefore, a rapid means for calibrating complete images will be required. The following describes a method for determining instrument wavelength calibration using atmospheric absorption features that is efficient enough to be used for entire images on workstations. This study shows the effect of the surface reflectance on the calibration accuracy and the calibration history for the AVIRIS B spectrometer over the 1992 flight season.

Goetz, Alexander F. H.↗

Antenna Calibration and Measurement Equipment

A document describes the Antenna Calibration & Measurement Equipment (ACME) system that will provide the Deep Space Network (DSN) with instrumentation enabling a trained RF engineer at each complex to perform antenna calibration measurements and to generate antenna calibration data. This data includes continuous-scan auto-bore-based data acquisition with all-sky data gathering in support of 4th order pointing model generation requirements. Other data includes antenna subreflector focus, system noise temperature and tipping curves, antenna efficiency, reports system linearity, and instrument calibration. The ACME system design is based on the on-the-fly (OTF) mapping technique and architecture. ACME has contributed to the improved RF performance of the DSN by approximately a factor of two. It improved the pointing performances of the DSN antennas and productivity of its personnel and calibration engineers.

Rochblatt, David J.↗

Experimental Evaluation of Stagnation Point Collection Efficiency of the NACA 0012 Swept Wing Tip

This paper presents the experimental work of a number of icing tests conducted in the Icing Research Tunnel at NASA Glenn Research Center to develop a test method for measuring the local collection efficiency of an impinging cloud at the leading edge of a NACA 0012 swept wing and with the data obtained to further calibrate a proposed correlation for such impingement efficiency calculation as a function of the modified inertia parameter and the sweep angle. The preliminary results showed that there could be some limitation of the test method due to the ice erosion problem when encountered, and also found that, for conditions free of such problem, the stagnation point collection efficiency measurement for sweep angles up to 45 could be well approximated by the proposed correlation. Further evaluation of this correlation is recommended in order to assess its applicability for swept-wing icing scaling analysis.

Tsao, Jen-Ching↗

Optimal Calibration of the Spitzer Space Telescope

A document discusses the focal-plane calibration of the Spitzer Space Telescope by use of the instrument pointing frame (IPF) Kalman filter, which was described in Kalman Filter for Calibrating a Telescope Focal Plane (NPO-40798), NASA Tech Briefs, Vol. 30, No. 9 (September 2006), page 62. To recapitulate: In the IPF Kalman filter, optimal estimates of both engineering and scientific focal-plane parameters are obtained simultaneously, using data taken in each focalplane survey activity. The IPF Kalman filter offers greater efficiency and economy, relative to prior calibration practice in which scientific and engineering parameters were estimated by separate teams of scientists and engineers and iterated upon each other. In the Spitzer Space Telescope application, the IPF Kalman filter was used to calibrate 56 frames for precise telescope pointing, estimate >1,500 parameters associated with focal-plane mapping, and process calibration runs involving as many as 1,338 scientific image centroids. The final typical survey calibration accuracy was found to be 0.09 arc second. The use of the IPF Kalman filter enabled a team of only four analysts to complete the calibration processing in three months. An unanticipated benefit afforded by the IPF Kalman filter was the ability to monitor health and diagnose performance of the entire end-to-end telescope-pointing system.

Bayard, David↗

Fission foil detector calibrations with high energy protons

Fission foil detectors (FFD's) are passive devices composed of heavy metal foils in contact with muscovite mica films. The heavy metal nuclei have significant cross sections for fission when irradiated with neutrons and protons. Each isotope is characterized by threshold energies for the fission reactions and particular energy-dependent cross sections. In the FFD's, fission fragments produced by the reactions are emitted from the foils and create latent particle tracks in the adjacent mica films. When the films are processed surface tracks are formed which can be optically counted. The track densities are indications of the fluences and spectra of neutrons and/or protons. In the past, detection efficiencies have been calculated using the low energy neutron calibrated dosimeters and published fission cross sections for neutrons and protons. The problem is that the addition of a large kinetic energy to the (n,nucleus) or (p,nucleus) reaction could increase the energies and ranges of emitted fission fragments and increase the detector sensitivity as compared with lower energy neutron calibrations. High energy calibrations are the only method of resolving the uncertainties in detector efficiencies. At high energies, either proton or neutron calibrations are sufficient since the cross section data show that the proton and neutron fission cross sections are approximately equal. High energy proton beams have been utilized (1.8 and 4.9 GeV, 80 and 140 MeV) for measuring the tracks of fission fragments emitted backward and forward.

Benton, E. V.↗

Synchrotron radiation calibration of the EUVE variable line-spaced diffraction gratings at the NBS SURF II facility

The Extreme Ultraviolet Explorer (EUVE) has a spectrometer which utilizes variable line-spaced, plane diffraction gratings in the converging beam of a Wolter-Schwarzschild type II mirror. The gratings, microchannel plate detector, and thin film filters have been calibrated with continuum radiation provided by the NBS SURF II facility. These were calibrated in a continuum beam to find edges or other sharp spectral features in the transmission of the filters, quantum efficiency of the microchannel plate detector, and efficiency of the gratings. The details of the calibration procedure and the results of the calibration are presented.

Jelinsky, P.↗

Space Infrared Telescope Facility (SIRTF) - Operations concept

The development and operations costs of the Space IR Telescope Facility (SIRTF) are discussed in the light of minimizing total outlays and optimizing efficiency. The development phase cannot extend into the post-launch segment which is planned to only support system verification and calibration followed by operations with a 70-percent efficiency goal. The importance of reducing the ground-support staff is demonstrated, and the value of the highly sensitive observations to the general astronomical community is described. The Failure Protection Algorithm for the SIRTF is designed for the 5-yr lifetime and the continuous venting of cryogen, and a science driven ground/operations system is described. Attention is given to balancing cost and performance, prototyping during the development phase, incremental development, the utilization of standards, and the integration of ground system/operations with flight system integration and test.

Miller, Richard B.↗