Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Efficiency as a Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Delamination-informed lifecycle decisions: A dielectric and machine learning framework for composite sorting and recycling

Composite materials are widely used in aerospace, marine, and automotive sectors due to their high strength-to-weight ratio and durability. However, their long-term reliability can be compromised by damage accumulation. Specifically, delamination initiation serves as a precursor to structural failure, which is often difficult to detect during damage inspection. Identifying and sorting delamination initiation in samples not only increases operational safety while providing critical information for end-of-life decisions, which influences both the service life extension value and the efficiency of fiber extraction during recycling. This research addresses two challenges: (1) developing a nondestructive, ex-situ framework to sort composite materials based on damage severity, particularly delamination, and (2) understanding how damage in composites influences resin removal during pyrolysis. Both experimental work and finite element analysis were performed to predict critical stress levels that are associated with delamination onset. Based on these results, three loading levels 50 %, 75 %, and 90 % of maximum stress, were selected for controlled experiments, generating composite samples with varying extents of damage for machine learning model training. Microscopic imaging of these samples confirmed the damage progression from matrix cracking to delamination, validating the computational predictions. We explored supervised machine learning using dielectric measurements to classify damage states. Preliminary results show an artificial neural network can identify early delamination which is a potential precursor to failure, with 94.44 % accuracy on our dataset. A parallel investigation into the effect of damage severity on pyrolysis recycling showed that heavily delaminated samples required significantly less energy for comparable matrix removal than undamaged samples.

dielectric variables↗

Machine learning surrogate of physics-based building-stock simulator for end-use load forecasting

Building energy models are used to simulate heat and mass transfer and estimate end-use load in buildings. With the proliferation of solar photovoltaics on residential and commercial buildings, increasingly, buildings are expected to provide grid services, for which accurate and computationally efficient building energy simulations and end-use load prediction are imperative. Existing building energy simulation tools, however, have significant computational overhead that make them less practical in real-time deployment for optimization, design, uncertainty quantification and control in building energy management systems. Here this article presents a data-driven machine learning model based on light gradient boosting method (LightGBM) as a surrogate for a physics-based simulator for residential buildings to predict end-use load. The machine learning based surrogate model accounts for time-series related variables, seasonality and trend component of end-use load, and history of end-use load. The accuracy of the surrogate model is assessed on the prediction of the load profiles of 100 different houses in Cook County, Illinois, USA. The LightGBM surrogate model is shown to reduce the root-mean-squared error by 53% relative to a reference decision tree (DT) based model reported previously in the literature. Moreover, the model predicts the load spikes and high-ramp rate events throughout the year which are often the Achilles heel of other models in the literature. The machine learning based surrogate model is demonstrated to be computationally efficient, with a ten-fold reduction in the computational time compared to a physics-based building energy simulation, and suitable for uncertainty analysis and real-time control of building characteristics in response to uncertainty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internal defect detection and characterization of samarium-cobalt sintered magnets by ultrasonic testing technique

Excessive quantities of samarium-cobalt (Sm-Co) magnet material are being scrapped needlessly due to a lack of understanding of inhomogeneity distribution and unacceptable internal defects. If there is a way to identify, locate, characterize and when needed separate the defective portions of magnet material, utilization can be increased and product quality improved. Further, the magnets’ magnetic and mechanical performance can be improved by reducing the occurrence of internal defects. This paper reports on a cost-effective and efficient nondestructive evaluation method based on an ultrasonic testing (UT) technique applied for detecting and characterizing internal defects in Sm-Co sintered magnets. Applying the UT technique will allow users to comprehensively analyze internal defects, such as inclusions, porosity, microcracks, and other structural irregularities, check for homogeneity and anomalous regions and give the locations of these internal anomalies and defects within the Sm-Co sintered magnets. The UT technique can also be applied to other rare-earth permanent magnets, such as sintered or die-upset neodymium-iron-boron (Nd-Fe-B) magnets. The UT technique can effectively guide quality control and acceptable product selection, in addition to optimizing the magnet alloy design and production processes. Therefore, it can facilitate the improvement of magnet manufacturing efficiency and machinability, reduce scrap, prolong service life, increase the use of what would be post-production waste, and enhance product reuse and recycling at end-of-life disposition.

36 MATERIALS SCIENCE↗

Determining Utility System Value of Demand Flexibility From Grid-interactive Efficient Buildings

This report focuses on ways current methods and practices that establish the value to electric utility systems of distributed energy resource (DER) investments can be enhanced to determine the value of demand flexibility in grid-interactive efficient buildings that can provide grid services. The report introduces key valuation concepts that are applicable to demand flexibility that these buildings can provide and links to other documents that describe these concepts and their implementation in more detail.The scope of this report is limited to the valuation of economic benefits to the utility system. These are the foundational values on which other benefits (and costs) can be built. Establishing the economic value to the grid of demand flexibility provides the information needed to design programs, market rules, and rates that align the economic interest of utility customers with building owners and occupants. By nature, DERs directly impact customers and provide societal benefits external to the utility system. Jurisdictions can use utility system benefits and costs as the foundation of their economic analysis but align their primary cost-effectiveness metric with all applicable policy objectives, which may include customer and societal (non-utility system) impacts.This report suggests enhancements to current methods and practices that state and local policymakers, public utility commissions, state energy offices, utilities, state utility consumer representatives, and other stakeholders might support. These enhancements can improve the consistency and robustness of economic valuation of demand flexibility for grid services. The report concludes with a discussion of considerations for prioritizing implementation of these improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Automated Mobility District Implementation Catalog: Insights from Ten Early-Stage Deployments

Major disruptive technologies are set to redefine the way in which people view travel, particularly in dense urban areas. Already, ride-hailing services have redefined mobility expectations of a new generation of urban dwellers in some places around the country. Over the next few decades, the proliferation of autonomous vehicles, which are generally referred to in the industry as “automated vehicles (AVs),” will be enhanced by the next generation of shared mobility. This combination of AV operations with on-demand service will provide convenience of mobility similar to that being exhibited in today’s transportation networking companies (TNCs). Shared, automated, public mobility resulting from the cross-hybridization of AVs with on-demand mobility service will bring economic and system efficiencies. Economic efficiencies may be realized by less vehicle ownership and more vehicle “usership.” Many companies are already exploring avenues for shared automated mobility through fleet operations as the wave of the future.

33 ADVANCED PROPULSION SYSTEMS↗

The Future Role of Hydropower in the Northeastern United States: May 2020-May 2022

This paper explores the future role of hydropower in the Northeastern US and beyond. The intent is to provide experience-based insights into how hydropower can best support the reliable and economic evolution of the New England power system and, more broadly, all US grids. Many of the challenges facing New England are driven by the potential integration of 10s of GWs of variable energy resources. Hydro can assist in remediating several issues, and the paper explores how Hydro might hit above its weight in a future low carbon New England system. Hydro can assist in handling periods of over generation, reduce the risk of curtailment of zero carbon resources, improve market efficiency, and provide valuable essential reliability services.

13 HYDRO ENERGY↗

Community Resilience Options: A Menu for Enhancing Local Energy Resilience

This document highlights areas of potential community resilience improvements, especially those that relate to clean energy deployment for communities and municipalities. The National Renewable Energy Laboratory (NREL) defines resilience as "a system's ability to anticipate, prepare for, and adapt to changing conditions and withstand, respond to, and recover rapidly from disruptions through sustainable, adaptable, and holistic planning and technical solutions." This document introduces 10 categories of resilience-enhancing projects at a high level, intended for community members and decision-makers new to the topic to build their understanding of which solutions fit their community best. These categories focus primarily on community-scale measures and different options may be available at larger scales. Full implementation of the measures described here requires in-depth, site-specific considerations that go beyond the scope of this document.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed Energy Resource (DER) Integration Framework: Regulatory Innovation for DER Compensation and Cost Allocation

Existing regulatory approaches to DER lack the precision and granularity necessary to ensure that DER can continue to scale in a cost-effective manner that is aligned with the public interest. To address this need, with the support of the U.S. Department of Energy’s Office of Electricity, Berkeley Lab and Current Energy Group developed an illustrative regulatory framework. By adopting a technology-neutral and modular approach, the framework enables flexibility and scalability for DER providers, utilities, and regulators. Clear price signals and incentives encourage the provision of valuable grid services, while equitable cost allocation promotes efficient use of distribution capacity and interconnection resources. This approach mirrors traditional ratemaking principles for importing customers and positions DERs as integral components of a dynamic and cost-effective energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Financing and Implementing Resilience Products

This fact sheet defines common resilience improvements and provides key considerations for identifying, prioritizing, and implementing these improvements across a commercial building portfolio. It also discusses common barriers to resilience improvements and reviews various third-party financing solutions that can help overcome these barriers.

CHP↗

Summer 2024 INL Intern Poster Session Submission - Brian Schumitz

This LRS submission is my poster for the INL Intern Poster Session, Summer 2024. Abstract: The Software Engineering and Cybersecurity Lab (SECL) at Montana State University has developed PIQUE, a system for evaluating software quality. PIQUE's adaptability allows for language-specific static-analysis operations, including a model for assessing cloud microservice ecosystems. These ecosystems often rely on Docker for efficient deployment and management of containerized services. Our research focuses on evaluating the network quality within these microservice ecosystems. To automate this process, we're utilizing Snort, an open-source intrusion detection system renowned for its ability to detect and log network traffic. By leveraging Snort's customizable rules, we aim to construct comprehensive testing methods for measuring and quantifying the network quality based on traffic between Docker containers. This research aims to enhance the overall security and reliability of cloud microservice ecosystems by providing automated and robust quality evaluation mechanisms, ultimately contributing to the advancement of software engineering practices in these environments

97 MATHEMATICS AND COMPUTING↗

Sustainable Public Transport: Providing Responsive, On-Demand Service with Clean Energy

The National Renewable Energy Laboratory (NREL) uses the Mobility Energy Productivity (MEP) as a metric and a lens to guide applied research into high performance public mobility. In the current initiative to abate global warming, the US needs not only zero-emission vehicles in the transit fleet (such as buses and shuttles) but also time- and cost-effective services to connect people with goods, services and employment toward a high-quality of life. Our current transportation system is overly dependent on personally-owned automobiles for high quality mobility, with public modes being less viable in many areas. Simply electrifying the drivetrains of existing public transit modes will fail to improve the quality of mobility for those that do not have access to private automobiles. The slow rebound by transit from the pandemic reveals the need to reinvent public transit service. Using the MEP lens, NREL researchers have tracked various novel developments in the public mobility space, with the confluence of shared, on-demand transit (ODT) services using light duty vehicles emerging as a key enabler of high-efficiency public mobility. Deployments such as those in Arlington, TX, Dallas, TX, Fort Erie, ON, and Innisfil, ON showcase the use of fleets of light-duty vehicles as the basis for community circulation and first/last mile to intra-regional transit. ODT services have demonstrated improvements in being more time efficient for riders, more energy efficient in operation (even before the introduction of fully electric vehicles), as well as being cost effective. It appears that aspects of the long-awaited promise of Personal Rapid Transit from the 1970s are beginning to be realized through ODT deployments, leveraging transportation network company (TNC) logistics, popularized by Uber and Lyft, but applied to public mobility. Currently, manually driven ODT operations are already cost competitive with traditional transit systems on a cost per ride basis, and full automation promises to reduce costs by 50% while providing additional safety and verified customer service. Connecting these ODT systems with efficient and effective intra-regional backbone transit service is the next step, with transit agencies like DART providing early results. This discussion will walk through the evidence for this postulated outcome and show results from a series of case-studies.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Congestion Management Solutions for Enhanced Distribution System Operations with Aggregated Distribution Grid Resources Providing Grid Services and Market Participation

Microgrids and other aggregations of distribution grid resources (DGRs) are poised to actively participate in electricity markets and provide essential grid services in the coming years. In fact, DGRs already play such a role through behind-the-meter (BTM) demand response programs and small-scale BTM dispatchable generation initiatives. At the same time, the rapid growth of artificial intelligence (AI) and cryptocurrency datacenters imposes significant, often unpredictable, demands on the power distribution system. Aggregated DGRs can serve as flexible resources that help mitigate these pressures by using available transmission and distribution capacity more efficiently, supporting resource adequacy and other reliability services, and providing bridge strategies while long-term transmission infrastructure is being developed. The impacts this activity will have on distribution networks are not fully understood and could present significant challenges for distribution utilities due to capacity constraints and the need for congestion management. Technical issues include reverse power flow, variability and possible degradation of equipment integrity, voltage violations, and customer power quality concerns. These issues will likely intensify as electricity market operators across the United States implement Federal Energy Regulatory Commission Order 2222 over the next few years.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Development of the Pooled Rideshare Acceptance Model (PRAM)

Due to the advancements in real-time information communication technologies and sharing economies, rideshare services have gained significant momentum by offering dynamic and/or on-demand services. Rideshare service companies evolved from personal rideshare, where riders traveled solo or with known individuals, into pooled rideshare (PR), where riders can travel with one to multiple unknown riders. Similar to other shared economy services, pooled rideshare is beneficial as it efficiently utilizes resources, resulting in reduced energy usage, as well as reduced costs for the riders. However, previous research has demonstrated that riders have concerns about using pooled rideshare, especially regarding personal safety. A U.S. national survey with 5385 participants was used to understand human factor-related barriers and user preferences to develop a novel Pooled Rideshare Acceptance Model (PRAM). This model used a covariance-based structural equation model (CB-SEM) to identify the relationships between willingness to consider PR factors (time/cost, privacy, safety, service experience, and traffic/environment) and optimizing one’s experience of PR factors (vehicle technology/accessibility, convenience, comfort/ease of use, and passenger safety), resulting in the higher-order factor trust service. We examined the factors’ relative contribution to one’s willingness/attitude towards PR and user acceptance of PR. Privacy, safety, trust service, and convenience were statistically significant factors in the model, as were the comfort/ease of use factor and the service experience, traffic/environment, and passenger safety factors. The only two non-significant factors in the model were time/cost and vehicle technology/accessibility; it is only when a rider feels safe that individuals then consider the additional non-significant variables of time, cost, technology, and accessibility. Privacy, safety, and service experience were factors that discouraged the use of PR, whereas the convenience factor greatly encouraged the acceptance of PR. Despite the time/cost factor’s lack of significance, individual items related to time and cost were crucial when viewed within the context of convenience. This highlights that while user perceptions of privacy and safety are paramount to their attitude towards PR, once safety concerns are addressed, and services are deemed convenient, time and cost elements significantly enhance their trust in pooled rideshare services. This study provides a comprehensive understanding of user acceptance of PR services and offers actionable insights for policymakers and rideshare companies to improve their services and increase user adoption.

dynamic rideshare system↗

A Survey of Direct Heating Equipment Market Actors in California

Direct Heating Equipment (DHE) is a category of ductless space heating appliances that provide warm air directly to the space where they are installed. We investigate, from the perspective of the DHE supply chain in California, what types of DHE are marketed in the state, how they are sold and serviced, and whether any potential barriers to adoption of high-efficiency DHE exist. We find that the market for DHE in the state is almost exclusively a replacement market, with some additional repair and maintenance services. We also find that, even though manufacturers sell high-efficiency DHE models in California, most contractors report installing baseline models most of the time. Contractors say their customers do not see any value in high-efficiency units, and they (contractors) do not believe that high-efficiency DHE is worth the additional cost to their customers. In addition, the majority of contractors purchase DHE from distributors and, therefore, distributors are a key piece of the supply chain that can constrain DHE purchase choice. Distributors do not see a demand for high-efficiency DHE and, hence, do not keep stock of these units. They argue that, since the market is driven mostly by replacements and these replacements occur typically in an unplanned way, homeowners are unwilling to pay for any additional costs associated with a high-efficiency model. Rather, homeowners usually prefer to replace the failed unit with a new unit that can fit in the same location with no- or minimal additional replacement costs. Considering that most DHE purchases are made by contractors, on behalf of their customers, informing contractors (and homeowners) of the potential cost-effectiveness of efficient DHE could help mitigate some of the barriers to the adoption of high-efficiency DHE in the state. In addition, monetary incentives and more stringent building codes that apply to DHE replacements can contribute to increasing adoption of high-efficiency DHE in California. This will not only reduce energy costs, but also increase safety and comfort to DHE users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Practical Analysis Framework for Assessment of Printed Circuit Heat Exchangers in High-Temperature Nuclear Service

Abstract Printed circuit heat exchangers (PCHEs) have high thermal efficiency because of the numerous minuscule channels. These minuscule channels result in a high thermal exchange area per unit volume, making PCHE a top contender for an intermediate heat exchanger (IHX) in high-temperature reactors. Thousands of minuscule channels make finite element analysis of the PCHE computationally infeasible. A two-dimensional analysis is usually performed for the PCHE core, which cannot simulate the local channel level responses reasonably because of the absence of global constraint influence. At present, there is no analysis technique available in the ASME Code or literature that is computationally efficient and suitable for engineers to estimate PCHE local responses. A novel but practical two-step analysis framework is proposed for performing PCHE analysis. In the first step, the channeled core is replaced by orthotropic solids with similar stiffness to simulate the global thermomechanical elastic responses of the PCHE. In the second step, local submodel analysis with detailed channel geometry and loading is performed using the elastic-perfectly plastic (EPP) material model. The proposed two-step analysis technique provides a unique capability to estimate the channel corner responses to be used for PCHE performance assessment. This study first developed a methodology for calculating the elastic orthotropic properties of the PCHE core. Next, the two-step analysis is performed for a realistic size PCHE core, and different issues observed in the results are scrutinized and resolved. Finally, a practical finite element analysis framework for PCHEs in high-temperature nuclear service is recommended.

Engineering↗

Integrated Urban Services: Regional Launch Event, 10-11 and 12-13 August 2021 [Slides]

The Integrated Urban Services (IUS) Program virtual launch event was conducted on August 10th and 12th, 2021 and provided education to the 26 cities in the ASEAN Smart Cities Network focused on integrated urban planning and the energy-food-water nexus. Experts representing academia, government, NGOs, and the private sector were invited to share knowledge and key lessons from their experience working on urban development projects in the ASEAN region and around the world. The IUS program, which is funded by the U.S. State Department and implemented by the National Renewable Energy Laboratory, aims to promote systems integration and circular economy principles for resource recovery and reuse at the city scale. This new initiative will help ASEAN cities build resilience in their energy, water, and food provision systems. The objectives of this three-year project are to: Educate stakeholders on the benefits of circular economy approaches such as resource recovery and reuse, and on opportunities to build cost-efficient and resilient models of basic urban service and food provision; Provide technical assistance to two select cities within ASEAN to aid them in implementing regenerative EWF system pilot projects; and Engage the private sector to promote market-based planning and investment to support pilot project implementation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Combined Heat and Power Deployment Program

Combined heat and power (CHP) is an efficient and clean approach to generating on-site electric power and useful thermal energy from a single fuel source. Instead of purchasing electricity from the distribution grid and burning fuel in an on-site furnace or boiler to produce thermal energy, CHP provides both energy services to a facility in one energy-efficient step.

CHP↗