At least 109 records · Page 6

Analysis of Water Extraction From Lunar Regolith

Distribution of water concentration on the Moon is currently an area of active research. Recent studies suggest the presence of ice particles, and perhaps even ice blocks and ice-cemented regolith on the Moon. Thermal extraction of the in-situ water is an attractive means of sa tisfying water requirements for a lunar mission. In this paper, a model is presented to analyze the processes occurring during the heat-up of icy regolith and extraction of the evolved water vapor. The wet regolith is assumed to be present in an initially evacuated and sealed cell which is subsequently heated. The first step of the analysis invol ves calculating the gradual increase of vapor pressure in the closed cell as the temperature is raised. Then, in the second step, the cell is evacuated to low pressure (e.g., vacuum), allowing the water vapor to leave the cell and be captured. The parameters affecting water vap or pressure build-up and evacuation for the purpose of extracting water from lunar regolith are discussed in the paper. Some comparisons wi th available experimental measurements are also made.

Hegde, U.↗

Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks

Large cryogenic liquid hydrogen tanks are composed of inner and outer shells. The outer shell is exposed to the ambient environment while the inner shell holds the liquid hydrogen. The region between these two shells is evacuated and typically filled with a powderlike insulation to minimize radiative coupling between the two shells. A technique was developed for detecting the presence of an air leak from the outside environment into this evacuated region. These tanks are roughly 70 ft (approx. equal 21 m) in diameter (outer shell) and the inner shell is roughly 62 ft (approx. equal 19 m) in diameter, so the evacuated region is about 4 ft (approx. equal 1 m) wide. A small leak's primary effect is to increase the boil-off of the tank. It was preferable to install a more accurate fill level sensor than to implement a boil-off meter. The fill level sensor would be composed of an accurate pair of pressure transducers that would essentially weigh the remaining liquid hydrogen. This upgrade, allowing boil-off data to be obtained weekly instead of over several months, is ongoing, and will then provide a relatively rapid indication of the presence of a leak.

Youngquist, Robert↗

Estimating the Risk of Renal Stone Events During Long-Duration Spaceflight

Introduction: Given the bone loss and increased urinary calcium excretion in the microgravity environment, persons participating in long-duration spaceflight may have an increased risk for renal stone formation. Renal stones are often an incidental finding of abdominal imaging studies done for other reasons. Thus, some crewmembers may have undiscovered, asymptomatic stones prior to their mission. Methods: An extensive literature search was conducted concerning the natural history of asymptomatic renal stones. For comparison, simulations were done using the Integrated Medical Model (IMM). The IMM is an evidence-based decision support tool that provides risk analysis and has the capability to optimize medical systems for missions by minimizing the occurrence of adverse mission outcomes such as evacuation and loss of crew life within specified mass and volume constraints. Results: The literature of the natural history of asymptomatic renal stones in the general medical population shows that the probability of symptomatic event is 8% to 34% at 1 to 3 years for stones < 7 mm. Extrapolated to a 6-month mission, for stones < 5 to 7 mm, the risk for any stone event is about 4 to 6%, with a 0.7% to 4% risk for intervention, respectively. IMM simulations compare favorably with risk estimates garnered from the terrestrial literature. The IMM forecasts that symptomatic renal stones may be one of the top drivers for medical evacuation of an International Space Station (ISS) mission. Discussion: Although the likelihood of a stone event is low, the consequences could be severe due to limitations of current ISS medical capabilities. Therefore, these risks need to be quantified to aid planning, limit crew morbidity and mitigate mission impacts. This will be especially critical for missions beyond earth orbit, where evacuation may not be an option.

Reyes, David↗

Estimating the Risk of Renal Stone Events during Long-Duration Spaceflight

Introduction: Given the bone loss and increased urinary calcium excretion in the microgravity environment, persons participating in long-duration spaceflight may have an increased risk for renal stone formation. Renal stones are often an incidental finding of abdominal imaging studies done for other reasons. Thus, some crewmembers may have undiscovered, asymptomatic stones prior to their mission. Methods: An extensive literature search was conducted concerning the natural history of asymptomatic renal stones. For comparison, simulations were done using the Integrated Medical Model (IMM). The IMM is an evidence-based decision support tool that provides risk analysis and has the capability to optimize medical systems for missions by minimizing the occurrence of adverse mission outcomes such as evacuation and loss of crew life within specified mass and volume constraints. Results: The literature of the natural history of asymptomatic renal stones in the general medical population shows that the probability of symptomatic event is 8% to 34% at 1 to 3 years for stones < 7 mm. Extrapolated to a 6-month mission, for stones < 5 to 7 mm, the risk for any stone event is about 4 to 6%, with a 0.7% to 4% risk for intervention, respectively. IMM simulations compare favorably with risk estimates garnered from the terrestrial literature. The IMM forecasts that symptomatic renal stones may be one of the top drivers for medical evacuation of an International Space Station (ISS) mission. Discussion: Although the likelihood of a stone event is low, the consequences could be severe due to limitations of current ISS medical capabilities. Therefore, these risks need to be quantified to aid planning, limit crew morbidity and mitigate mission impacts. This will be especially critical for missions beyond earth orbit, where evacuation may not be an option.

Reyes, David↗

Optimizing Medical Kits for Spaceflight

The Integrated Medical Model (IMM) is a probabilistic model that estimates medical event occurrences and mission outcomes for different mission profiles. IMM simulation outcomes describing the impact of medical events on the mission may be used to optimize the allocation of resources in medical kits. Efficient allocation of medical resources, subject to certain mass and volume constraints, is crucial to ensuring the best outcomes of in-flight medical events. We implement a new approach to this medical kit optimization problem. METHODS We frame medical kit optimization as a modified knapsack problem and implement an algorithm utilizing a dynamic programming technique. Using this algorithm, optimized medical kits were generated for 3 different mission scenarios with the goal of minimizing the probability of evacuation and maximizing the Crew Health Index (CHI) for each mission subject to mass and volume constraints. Simulation outcomes using these kits were also compared to outcomes using kits optimized..RESULTS The optimized medical kits generated by the algorithm described here resulted in predicted mission outcomes more closely approached the unlimited-resource scenario for Crew Health Index (CHI) than the implementation in under all optimization priorities. Furthermore, the approach described here improves upon in reducing evacuation when the optimization priority is minimizing the probability of evacuation. CONCLUSIONS This algorithm provides an efficient, effective means to objectively allocate medical resources for spaceflight missions using the Integrated Medical Model.

Optimization↗

Mass and Volume Optimization of Space Flight Medical Kits

Resource allocation is a critical aspect of space mission planning. All resources, including medical resources, are subject to a number of mission constraints such a maximum mass and volume. However, unlike many resources, there is often limited understanding in how to optimize medical resources for a mission. The Integrated Medical Model (IMM) is a probabilistic model that estimates medical event occurrences and mission outcomes for different mission profiles. IMM simulates outcomes and describes the impact of medical events in terms of lost crew time, medical resource usage, and the potential for medically required evacuation. Previously published work describes an approach that uses the IMM to generate optimized medical kits that maximize benefit to the crew subject to mass and volume constraints. We improve upon the results obtained previously and extend our approach to minimize mass and volume while meeting some benefit threshold. METHODS We frame the medical kit optimization problem as a modified knapsack problem and implement an algorithm utilizing dynamic programming. Using this algorithm, optimized medical kits were generated for 3 mission scenarios with the goal of minimizing the medical kit mass and volume for a specified likelihood of evacuation or Crew Health Index (CHI) threshold. The algorithm was expanded to generate medical kits that maximize likelihood of evacuation or CHI subject to mass and volume constraints. RESULTS AND CONCLUSIONS In maximizing benefit to crew health subject to certain constraints, our algorithm generates medical kits that more closely resemble the unlimited-resource scenario than previous approaches which leverage medical risk information generated by the IMM. Our work here demonstrates that this algorithm provides an efficient and effective means to objectively allocate medical resources for spaceflight missions and provides an effective means of addressing tradeoffs in medical resource allocations and crew mission success parameters.

Monte Carlo Method↗

Estimating Tropical Cyclone Threats to Floating Rigs in the Gulf of Mexico

Offshore drilling operations in the Gulf of Mexico are particularly vulnerable during hurricane season. When a weather threat arises, a decision to evacuate the rig and/or move to a safe location may need to be made. Depending on the activities in progress at the time of the threat, securing the well, evacuating, and/or moving to a safe location can take a considerable amount of time. This transition time is called T-time. T-time is not only rig dependent, but also depends on the activity being performed at the time of the threat. For these reasons it is important to assess tropical cyclone threats and the time it takes for them to reach the rig location. The objective of this study is to use the available 50 years of past cyclone history to estimate cyclone threats at any location in the Gulf of Mexico. The cyclone threat is estimated based on the rig location as well as the start date and duration of the offshore activity. By threat, it is meant the likelihood that a specific location with an associated offshore activity would be exposed to an upcoming cyclone whose forecasted track cone and storm size lies within that location. Three representative rig locations in the Gulf of Mexico were selected as assessment sites to evaluate the threat of incoming cyclones for different T-times. To conduct this tropical cyclone study, an Excel spreadsheet tool was developed to automate the analysis of the tropical cyclone data from the Best Track Archive for Climate Stewardship (IBTrACS) Version 4. The spreadsheet tool allows the user to input any location (i.e., longitude and latitude) in the Gulf of Mexico and displays a list of historical cyclones that have passed within 150 nautical miles of that location during the activity period selected by the user. Also, the tool allows the user to input a T-time to assess the threat of cyclones that would not provide adequate time to secure the well, evacuate, and/or move to a safe location.

Risk↗

Estimating Tropical Cyclone Threats to Floating Rigs in the Gulf of Mexico

Offshore drilling operations in the Gulf of Mexico are particularly vulnerable during hurricane season. When a weather threat arises, a decision to evacuate the rig and/or move to a safe location may need to be made. Securing the well, evacuating, and/or moving to a safe location can take a considerable amount of time. This transition time is called T-time. T-time is not only rig dependent, but also depends on the activity being performed at the time of the threat. For these reasons, it is important to assess tropical cyclone threats and the estimated time it will take the storm to reach the rig location from the time it is first detected. The objective of this study is to use 50 years of cyclone history from a National Oceanic and Atmospheric Administration’s (NOAA) database, the International Best Track Archive for Climate Stewardship (IBTrACS) to estimate cyclone threats at any location in the Gulf of Mexico. The cyclone threat is estimated based on the rig location as well as the start date and duration of the offshore activity. By threat, it is meant the likelihood that a specific location with an associated offshore activity lies within the forecasted track cone and storm size of the upcoming cyclone. Three representative rig locations in the Gulf of Mexico were selected as assessment sites to evaluate the threat of incoming cyclones for different T-times. To conduct this tropical cyclone study, an Excel spreadsheet tool was developed to automate the analysis of the tropical cyclone data. The spreadsheet tool allows the user to input any location (i.e., longitude and latitude) in the Gulf of Mexico and displays a list of historical cyclones that have passed within 150 nautical miles of that location during the activity period selected by the user. In addition, the tool allows the user to input any T-time to assess the threat of cyclones that would not provide adequate time to secure the well, evacuate, and/or move to a safe location.

Offshore Oil Drilling↗

Quantifying Risk to Improve Medical System Design for Long Duration Artemis Missions: A Demonstration of NASA's IMPACT Tradespace Analysis Tool

BACKGROUND NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. A greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the evacuation of ill or injured crew. Mass, volume, and power will be limited while higher demands will be placed on the crews to manage medical events. NASA’s Moon to Mars exploration strategy outlines increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human system risk attributable to medical conditions and use these estimates to advance medical system design. METHODS IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a probabilistic risk assessment (PRA) and tradespace analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; a large increase in the number of medical resources and the flexibility of their use; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to mimic a foundational exploration Artemis mission. The DRM profile includes outbound transit on Orion, Gateway space station rendezvous in lunar orbit, 6 months on the Lunar surface with extravehicular activity (EVA), return rendezvous with Gateway, and transit back to Earth. RESULTS/DISCUSSION: Overall, IMPACT successfully quantified medical risk and derived an optimal medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to medical risk were decompression sickness, trauma, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions and performed as expected. This demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Arian Anderson↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Emergency escape system uses self-braking mechanism on fixed cable

Slide-wire system with a twist level slide device incorporates automatic descent and braking for the safe and rapid evacuation of personnel from tall structures. This device is used on any tall structure that might require emergency evacuation. It is also used to transfer materials and equipment.

Billings, C. R.↗

New shield for gamma-ray spectrometry

Gamma-ray shield that can be evacuated, refilled with a clean gas, and pressurized for exclusion of airborne radioactive contaminants effectively lowers background noise. Under working conditions, repeated evacuation and filling procedures have not adversely affected the sensitivity and resolution of the crystal detector.

Brar, S. S.↗

Nondestructive leak testing

Method provides opportunity to effect repairs without compromising integrity of enclosed circuitry or mechanism by loss of atmosphere or by ingestion of foreign matter or gas. It is possible to detect leaks in modules which are sealed while fully evacuated, partially evacuated, or containing some form of gas.

Lusby, T. K., Jr.↗

Thermal performance of multilayer insulations

Experimental and analytical studies were conducted in order to extend previous knowledge of the thermal performance and gas evacuation characteristics of three selected multilayer insulation (MLI) composites. Flat plate calorimeter heat flux measurements were obtained for 20- and 80- shield specimens using three representative layer densities over boundary temperatures ranging from 39 K (70 R) to 389 K (700 R). Laboratory gas evacuation tests were performed on representative specimens of each MLI composite after initially purging them with helium, nitrogen, or argon gases. In these tests, the specimens were maintained at temperatures between 128 K (230 R) and 300 K (540 R). Based on the results of the laboratory-scale tests, a composite MLI system consisting of 112 unperforated, double-aluminized Mylar reflective shields and 113 water preconditioned silk net spacer pairs was fabricated and installed on a 1.22-m-(4-ft-) diameter calorimeter tank.

Keller, C. W.↗

Ultra sound absorption measurements in rock samples at low temperatures

A new technique, comparable with the reverberation method in room acoustics, is described. It allows Q-measurements at rock samples of arbitrary shape in the frequency range of 50 to 600 kHz in vacuum (.1 mtorr) and at low temperatures (+20 to -180 C). The method was developed in particular to investigate rock samples under lunar conditions. Ultrasound absorption has been measured at volcanics, breccia, gabbros, feldspar and quartz of different grain size and texture yielding the following results: evacuation raises Q mainly through lowering the humidity in the rock. In a dry compact rock, the effect of evacuation is small. With decreasing temperature, Q generally increases. Between +20 and -30 C, Q does not change much. With further decrease of temperature in many cases distinct anomalies appear, where Q becomes frequency dependent.

Herminghaus, C.↗

Soft X-ray lasers using distributed-feedback reflection: A concept

Proposed arrangement consists of large evacuated chamber containing smaller Dewar chamber into which liquid neon is introduced. Zeolite crystal is mounted in wall of chamber, with one side in contact with neon and other exposed to evacuated chamber. Electron gun is used to bombard crystal.

Grunthaner, F. J.↗

A fixed tilt solar collector employing reversible vee-trough reflectors and vacuum tube receivers for solar heating and cooling systems

The usefulness of vee-trough concentrators in improving the efficiency and reducing the cost of collectors assembled from evacuated tube receivers was studied in the vee-trough/vacuum tube collector (VTVTC) project. The VTVTC was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrator and the thermal performance of the evacuated tube receiver. A test bed was constructed to verify the mathematical analyses and compare reflectors made out of glass, Alzak and aluminized FEP Teflon. Tests were run at temperatures ranging from 95 to 180 C. Vee-trough collector efficiencies of 35 to 40% were observed at an operating temperature of about 175 C. Test results compared well with the calculated values. Predicted daily useful heat collection and efficiency values are presented for a year's duration of operation temperatures ranging from 65 to 230 C. Estimated collector costs and resulting thermal energy costs are presented. Analytical and experimental results are discussed along with a complete economic evaluation.

Selcuk, M. K.↗