Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sensor-Assisted Fault Mitigation in Quantum Computation

We propose a method for assisting fault mitigation in quantum computation through the use of sensors, co-located near physical qubits. Specifically, we consider using transition edge sensors co-located on silicon substrates hosting superconducting qubits to monitor for energy injection from ionizing radiation that has been demonstrated to increase decoherence in transmon qubits. We generalize from these two physical device concepts and explore the potential advantages of co-located sensors to assist fault mitigation in quantum computation. In the simplest scheme, co-located sensors beneficially assist rejection of calculations potentially affected by environmental disturbances. Investigating the potential computational advantage further required development of an extension to the standard formulation of quantum error correction. In a specific case the standard three-qubit, bit flip quantum correction code, we show that given a 20% overall error probability per qubit, approximately 90% of repeated calculation attempts are correctable. However, when sensor-detectable errors account for 45% of overall error probability, the use of colocated sensors uniquely associated with independent qubits, boosts the fraction of correct final-state calculations to 96% at the cost of rejecting 7% of repeated calculation attempts.

Orrell, John L.↗

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-E-9A-01: Risk Based Quality Management: TG100 In Action

One of the goals of quality management in radiation therapy is to gain high confidence that patients will receive the prescribed treatment correctly. To accomplish these goals professional societies such as the American Association of Physicists in Medicine (AAPM) has published many quality assurance (QA), quality control (QC), and quality management (QM) guidance documents. In general, the recommendations provided in these documents have emphasized on performing device-specific QA at the expense of process flow and protection of the patient against catastrophic errors. Analyses of radiation therapy incidents find that they are most often caused by flaws in the overall therapy process, from initial consult through final treatment, than by isolated hardware or computer failures detectable by traditional physics QA. This challenge is shared by many intrinsically hazardous industries. Risk assessment tools and analysis techniques have been developed to define, identify, and eliminate known and/or potential failures, problems, or errors, from a system, process and/or service before they reach the customer. These include, but are not limited to, process mapping, failure modes and effects analysis (FMEA), fault tree analysis (FTA), and establishment of a quality management program that best avoids the faults and risks that have been identified in the overall process. These tools can be easily adapted to radiation therapy practices because of their simplicity and effectiveness to provide efficient ways to enhance the safety and quality of treatment processes. Task group 100 (TG100) of AAPM has developed a risk-based quality management program that uses these tools. This session will be devoted to a discussion of these tools and how these tools can be used in a given radiotherapy clinic to develop a risk based QM program. Learning Objectives: Learn how to design a process map for a radiotherapy process. Learn how to perform a FMEA analysis for a given process. Learn what Fault tree analysis is all about. Learn how to design a quality management program based upon the information obtained from process mapping, FMEA and FTA.

60 APPLIED LIFE SCIENCES↗

Quantum computing hardware for HEP algorithms and sensing

Quantum information science harnesses the principles of quantum mechanics to realize computational algorithms with complexities vastly intractable by current computer platforms. Typical applications range from quantum chemistry to optimization problems and also include simulations for high energy physics. The recent maturing of quantum hardware has triggered preliminary explorations by several institutions (including Fermilab) of quantum hardware capable of demonstrating quantum advantage in multiple domains, from quantum computing to communications, to sensing. The Superconducting Quantum Materials and Systems (SQMS) Center, led by Fermilab, is dedicated to providing breakthroughs in quantum computing and sensing, mediating quantum engineering and HEP based material science. The main goal of the Center is to deploy quantum systems with superior performance tailored to the algorithms used in high energy physics. In this Snowmass paper, we discuss the two most promising superconducting quantum architectures for HEP algorithms, i.e. three-level systems (qutrits) supported by transmon devices coupled to planar devices and multi-level systems (qudits with arbitrary N energy levels) supported by superconducting 3D cavities. For each architecture, we demonstrate exemplary HEP algorithms and identify the current challenges, ongoing work and future opportunities. Furthermore, we discuss the prospects and complexities of interconnecting the different architectures and individual computational nodes. Finally, we review several different strategies of error protection and correction and discuss their potential to improve the performance of the two architectures. This whitepaper seeks to reach out to the HEP community and drive progress in both HEP research and QIS hardware.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

60 APPLIED LIFE SCIENCES↗

SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table

Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specific patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.

60 APPLIED LIFE SCIENCES↗

SU-E-P-54: Evaluation of the Accuracy and Precision of IGPS-O X-Ray Image-Guided Positioning System by Comparison with On-Board Imager Cone-Beam Computed Tomography

Purpose: The purpose of this study is to assess the positioning accuracy and precision of IGPS-O system which is a novel radiographic kilo-voltage x-ray image-guided positioning system developed for clinical IGRT applications. Methods: IGPS-O x-ray image-guided positioning system consists of two oblique sets of radiographic kilo-voltage x-ray projecting and imaging devices which were equiped on the ground and ceiling of treatment room. This system can determine the positioning error in the form of three translations and three rotations according to the registration of two X-ray images acquired online and the planning CT image. An anthropomorphic head phantom and an anthropomorphic thorax phantom were used for this study. The phantom was set up on the treatment table with correct position and various “planned” setup errors. Both IGPS-O x-ray image-guided positioning system and the commercial On-board Imager Cone-beam Computed Tomography (OBI CBCT) were used to obtain the setup errors of the phantom. Difference of the Result between the two image-guided positioning systems were computed and analyzed. Results: The setup errors measured by IGPS-O x-ray image-guided positioning system and the OBI CBCT system showed a general agreement, the means and standard errors of the discrepancies between the two systems in the left-right, anterior-posterior, superior-inferior directions were −0.13±0.09mm, 0.03±0.25mm, 0.04±0.31mm, respectively. The maximum difference was only 0.51mm in all the directions and the angular discrepancy was 0.3±0.5° between the two systems. Conclusion: The spatial and angular discrepancies between IGPS-O system and OBI CBCT for setup error correction was minimal. There is a general agreement between the two positioning system. IGPS-O x-ray image-guided positioning system can achieve as good accuracy as CBCT and can be used in the clinical IGRT applications.

60 APPLIED LIFE SCIENCES↗

Solovay-Kitaev Algorithm and Randomized Compilation Data Availability

This zipped folder contains simulation notebooks, simulated data, and experimental data from the QSCOUT trapped-ion device that were used in the publication "Solovay-Kitaev Algorithm and Randomized Compilation" (https://doi.org/10.1103/ll6m-dbl7). The raw data is in the form of measurement outcomes of simple tomographic quantum circuits that were executed on the QSCOUT device and simulated using JAQALPAQ. These data are used to create plots within the jupyter notebooks that were included in the publication.

Quantum benchmarking↗

ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

97 MATHEMATICS AND COMPUTING↗

Reliable voltage scaled links for compressed data

Systems, apparatuses, and methods for reliably transmitting data over voltage scaled links are disclosed. A computing system includes at least first and second devices connected via a link. In one implementation, if a data block can be compressed to less than or equal to half the original size of the data block, then the data block is compressed and sent on the link in a single clock cycle rather than two clock cycles. If the data block cannot be compressed to half the original size, but if the data block can be compressed enough to include error correction code (ECC) bits without exceeding the original size, then ECC bits are added to the compressed block which is sent on the link at a reduced voltage. The ECC bits help to correct for any errors that are generated as a result of operating the link at the reduced voltage.

42 ENGINEERING↗

Superconducting microwave cavities and qubits for quantum information systems

Superconducting microwave cavities featuring ultrahigh Q-factors, which measure the efficiency of energy storage in relation to energy loss in a system, are revolutionizing quantum computing by providing long coherence times exceeding 1 ms, crucial for the development of scalable multi-qubit quantum systems with low error rates. Here, in this work, we provide an in-depth analysis of recent advances in ultrahigh Q-factor cavities, integration of Josephson junction-based qubits, and bosonic-encoded qubits in 3D cavities. We examine the sources of quantum state dephasing caused by damping and noise mechanisms in cavities and qubits, highlighting the critical challenges that need to be addressed to achieve even higher coherence times. We critically survey the latest progress made in implementing single 3D qubits using superconducting materials, normal metals, and multi-qubit and multi-state quantum systems. Our work sheds light on the promising future of this research area, including novel materials for cavities and qubits, modes with nontrivial topological properties, error correction techniques for bosonic qubits, and new light–matter interaction effects.

3D printing↗

A new method for tracking organ motion on diagnostic ultrasound images

Purpose: Respiratory-gated irradiation is effective in reducing the margins of a target in the case of abdominal organs, such as the liver, that change their position as a result of respiratory motion. However, existing technologies are incapable of directly measuring organ motion in real-time during radiation beam delivery. Hence, the authors proposed a novel quantitative organ motion tracking method involving the use of diagnostic ultrasound images; it is noninvasive and does not entail radiation exposure. In the present study, the authors have prospectively evaluated this proposed method. Methods: The method involved real-time processing of clinical ultrasound imaging data rather than organ monitoring; it comprised a three-dimensional ultrasound device, a respiratory sensing system, and two PCs for data storage and analysis. The study was designed to evaluate the effectiveness of the proposed method by tracking the gallbladder in one subject and a liver vein in another subject. To track a moving target organ, the method involved the control of a region of interest (ROI) that delineated the target. A tracking algorithm was used to control the ROI, and a large number of feature points and an error correction algorithm were used to achieve long-term tracking of the target. Tracking accuracy was assessed in terms of how well the ROI matched the center of the target. Results: The effectiveness of using a large number of feature points and the error correction algorithm in the proposed method was verified by comparing it with two simple tracking methods. The ROI could capture the center of the target for about 5 min in a cross-sectional image with changing position. Indeed, using the proposed method, it was possible to accurately track a target with a center deviation of 1.54 ± 0.9 mm. The computing time for one frame image using our proposed method was 8 ms. It is expected that it would be possible to track any soft-tissue organ or tumor with large deformations and changing cross-sectional position using this method. Conclusions: The proposed method achieved real-time processing and continuous tracking of the target organ for about 5 min. It is expected that our method will enable more accurate radiation treatment than is the case using indirect observational methods, such as the respiratory sensor method, because of direct visualization of the tumor. Results show that this tracking system facilitates safe treatment in clinical practice.

60 APPLIED LIFE SCIENCES↗

Unified architecture for quantum lookup tables

Quantum access to arbitrary classical data encoded in unitary black-box oracles underlies interesting data-intensive quantum algorithms, such as machine learning or electronic structure simulation. The feasibility of these applications depends crucially on gate-efficient implementations of these oracles, which are commonly some reversible versions of the Boolean circuit for a classical lookup table. Here, we present a general parametrized architecture for quantum circuits implementing a lookup table that encompasses all prior work in realizing a continuum of optimal trade-offs between qubits, non-Clifford gates, and error resilience, up to logarithmic factors. Our architecture assumes only local 2D connectivity, yet recovers results, with the appropriate parameters, polylogarithmic error scaling. We also identify regimes, such as simultaneous sublinear scaling, in all parameters. These results enable tailoring implementations of the commonly used lookup table primitive to any given quantum device with constrained resources.

quantum circuits↗

SU-E-T-181: Clinical Implementation of Task Group 176

Purpose: The implementation of TG-176 with regards to immobilization devices and couch tops as they effect dosimetric treatment planning. Methods: The external devices used clinically were scanned to measure their HU values. Plans were created in the Eclipse treatment planning system (TPS) using these devices, one that accounted for the correct HU value of the each device and another that did not include the device as a structure. A dose subtraction was performed between the two plans to evaluate the dosimetric differences. The metrics used for evaluation included attenuation and surface dose. Plan parameters were varied to evaluate the impact of the devices in different clinical scenarios. Results: While the exact HU values of our results are clinic-dependent, the protocol being implemented is widely applicable. We recommend a four step process for implementing this task group. First, physics should scan each treatment device to determine accurate HU values. Second, CT therapists should include in the setup note which table top was used during patient CT simulation and are asked to make immobilization devices as uniform in thickness as possible. Therapists should also index the devices whenever possible so beam will traverse the same area of the device. Third, the dosimetrist should manually correct the HU value for any external device, including the couch. For H&N cases, the rails must be removed from the couch structure. When rails are used during treatments, it is important to make note of their exact position in the setup notes. Finally, physicians should be made aware that there could be changes in surface doses depending on whether or not immobilization devices or couch tops are in the beam path. Conclusion: The protocol outlined above was implemented to reduce the errors that arise from ignoring effects of external devices, thus ensuring safer, more accurate patient treatments.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

60 APPLIED LIFE SCIENCES↗

Mitigation of the Brighter-Fatter Effect in the LSST Camera

Thick, fully depleted charge-coupled devices (CCDs) are known to exhibit non-linear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). This particularly impacts bright calibration stars, which appear larger than their intrinsic shape, creating a flux-dependent point-spread function (PSF) that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSST Camera before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new sampling method based on a physically motivated model to account these higher-order terms in the correction, and then we test the modified correction on both datasets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars which we conclude is the result of a unmodeled curl component of the deflection field by the correction. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Photometric Recalibration of the SDSS Stripe 82 to a Few Millimagnitude Precision with the Stellar Color Regression Method and Gaia EDR3

By combining spectroscopic data from the LAMOST DR7, Sloan Digital Sky Survey (SDSS) DR12, and corrected photometric data from the Gaia EDR3, we apply the stellar color regression (SCR) method to recalibrate the SDSS Stripe 82 standard stars catalog of Ivezic' et al. With a total number of about 30,000 spectroscopically targeted stars, we have mapped out the relatively large and strongly correlated photometric zero-point errors present in the catalog, ~2.5% in the u band and ~1% in the griz bands. Our study also confirms some small but significant magnitude dependence errors in the z band for some charge-coupled devices. Various tests show that we have achieved an internal precision of about 5 mmag in the u band and about 2 mmag in the griz bands, which is about five times better than previous results. We also apply the method to the latest version of the catalog (v4.2), and find modest systematic calibration errors of up to ~1% along the R.A. direction and smaller errors along the decl. direction. The results demonstrate the power of the SCR method when combining spectroscopic data and Gaia photometry in breaking the 1% precision barrier of ground-based photometric surveys. Our work paves the way for the recalibration of the whole SDSS photometric survey and has important implications for the calibration of future surveys. Future implementations and improvements of the SCR method under different situations are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗