Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EMIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Data and scripts associated with the manuscript "Estimating soil moisture and salinity response to simulated coastal flooding using time-lapse electrical resistivity and induced polarization monitoring”

This package contains geophysics datasets generated during the simulated ecosystem-flooding experiment – TEMPEST (Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatment). These geophysics data consist of Electrical Resistivity Imaging (ERI) and Induced Polarization (IP) datasets collected to estimate the soil moisture and salinity response to the simulated coastal flooding experiment. In addition to using geophysics datasets to estimate soil moisture and salinity response, petrophysical relationship between the measured resistivity and moisture content and salinity using the multisalinity. This package consists of two folders: “MultiSalinity Experiment” folder and “TEMPEST Experiment and petrophysical conversion” folders. The “MultiSalinity Experiment” folder contains the datasets generated from the multisalinity experiment used to develop the petrophysical reslationship. The “TEMPEST Experiment and petrophysical conversion” folder contains ERI, IP, Ground Penetrating Radar (GPR) and Electromagnetic Induction (EMI) datasets collected during the TEMPEST experiment. This study shows the ability to used geophysical datasets in estimating moisture content and salinity at scale will be useful in calibrating Earth System Models.

54 ENVIRONMENTAL SCIENCES↗

The importance of accounting for landscape position when investigating grasslands: A multidisciplinary characterisation of a Californian coastal grassland

Data from the characterisation of the Point Reyes Field Site, published in AGU Earth's Future under the title: The importance of accounting for landscape position when investigating grasslands: A multidisciplinary characterisation of a Californian coastal grassland. This paper explored the effect of landscape position on the response of a Californian grassland to seasonal changes. All files are csv files. The EMI data contains 8 csv files with a metadata csv explaining the columns. The dataset also includes soil variables including total concentrations calculated from fused samples, then dissolved and measured on ICP-AES for whole-rock elements and ICP-MS for trace elements. Mineral composition was attained using X-ray diffraction at BL 11-3 at SSRL . Data was then run through the High Score database to characterise different mineral phases. total It also includes a table with bulk soil characteristics such as soil pH, cation exchange capacity, and soil textural data. Data from Teros 12 Meter soil moisture, electrical conductivity and temperature sensors are presented in SMS Csv file. While the WL bottom and top files contain data from Piezometers measuring the ground water table. We have included a csv file that contains soil CO2 efflux data from Feb 2021-Oct 2021 in the Point Reyes Grassland Experiment We have included the spatially orientated (easting northing) remotely sensed datasets that were used in the K-means clustering analysis conducted on our site with electrical conductivity, normalised difference vegetation index, elevation, slope, solar radiation, topographic position and wetness index, and a clustering score. Finally there is a list of all the identified grassland species at the site.For more information on flux data, please contact the corresponding author.

54 ENVIRONMENTAL SCIENCES↗

Geophysical survey associated with NEON AOP survey, East River, CO 2018

The package contains data layers developed and used in Falco et al. 2024: “EcoImaging: Advanced Sensing to Investigate Plant and Abiotic Hierarchical Spatial Patterns in Mountainous Watersheds". The package is part of the DOE Watershed Function Science Focus Area (SFA) project and includes geophysical measurements collected at the East River, Colorado, in conjunction with the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) survey conducted in June 2018. This dataset provide soil geophysical information and were used to investigate soil-plant relationships. The dataset consists of: - NEON_2018_EMI_survey.zip: the electromagnetic induction (EMI) survey as shape-file; - NEON_plot_TDR.csv: plot‑level data from Time‑Domain Reflectometry (TDR) measurements, providing: * volumetric water content (VWC) in percent (%); * soil temperature in degrees Celsius (°C); - file level metadata (flmd.csv) - data dictionary (dd.csv) file This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Arroyo Mocho Habitat Suitability Assessment for Sensitive Reptiles, Amphibians, and Fish

Sequoia Ecological Consulting, Inc. (Sequoia) has prepared this habitat suitability assessment for the purpose of assessing current habitat suitability and evaluating the potential presence of special-status species at and near the Arroyo Mocho Pumping Station (Arroyo Mocho). The Study Area is located 7.5 miles southeast of the City of Livermore in Alameda County, California. Our analysis provides a description of presence and habitat suitability for special-status reptiles, amphibians, and fish within the Study Area and identifies potential conservation measures. Special-status animals are designated by the US Fish and Wildlife Service (USFWS) and the California Department of Fish and Wildlife (CDFW). This analysis focuses on California tiger salamander (Ambystoma californiense), California red-legged frog (Rana draytonii), foothill yellow-legged frog (Rana boylii), western pond turtle (Emys marmorata), Alameda whipsnake (Masticophis lateralis euryxanthus), Coast horned lizard (Phrynosoma blainvilli), and central California coast distinct population segment (DPS) steelhead (Oncorhynchus mykiss), per the request of Lawrence Livermore National Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Reliable, Cost-Effective Transformerless Medium-Voltage Inverter for Grid Integration of Combined Solar and Energy Storage

The goal of this project is to utilize an innovative holistic power electronic inverter design approach, which can leverage best-in-class silicon carbide (SiC) power modules, novel multi-level power electronic circuits, high frequency transformers, switching sequence based control and co-designed electro-thermal management methods, to realize a 300 kW transformerless medium-voltage (MV) inverter system. The system cost of the inverter is considered as a primary design objective alongside high power density, efficiency, low electromagnetic interference (EMI) and long lifespan. This design-oriented research activity, especially the proposed multi-objective optimization approach, will have broad impacts in holistic power electronic system design methods and in technologies that can be commercialized into a wide variety of wide bandgap power electronic applications.

14 SOLAR ENERGY↗

High-Precision Low-Cost Micro Birdbath Resonating Gyroscope (CRADA Final Report)

As part of the Cyclotron Road program, Enertia Microsystems Inc. (EMI) investigated a high-performance micro mechanical resonator called the micro birdbath resonator and a high-precision micro electromechanical systems (MEMS) gyroscope called the birdbath resonator gyroscope (BRG). The BRG is a novel fused-silica MEMS gyroscope. The BRG can obtain significantly greater accuracy, comparable size, and comparable cost with MEMS gyroscopes made of silicon that are currently on the market.

47 OTHER INSTRUMENTATION↗

Wholesale Electricity Markets and Resource Adequacy with High Clean Energy Generation Targets

Wholesale electricity markets are intended to incentivize system generation investments and operations outcomes that meet evolving system needs. In this work, we evaluate the effectiveness of wholesale market structures, rules and policies in achieving system resource adequacy (RA) and clean energy targets in the presence of self-interested generation investors using the Electricity Markets and Investment Suite Agent-based Simulation (EMIS-AS) model. Results highlight that both capacity markets and operating reserve demand curves (ORDCs) can help achieve a reliable system but with different RA compliance timelines and distribution of generation technologies. Structures with capacity markets tend to favor more capital-intensive peaking technologies while reducing wind and solar build-outs due to suppressed energy and clean energy market prices, particularly in the absence of strong clean energy targets. Conversely, ORDCs improve the commitment of available generation units, but this comes at the expense of higher system costs and renewable generation curtailment. We also find that well-calibrated static capacity demand curves can yield similar reliability and total cost compared to capacity market demand curves informed dynamically by resource adequacy while also yielding stable annual capacity prices. Different approaches to formulating ORDC curves can also yield key trade-offs, namely that a more efficient treatment of storage chronology results in lower ORDC curves and prices, yielding less investment and cost but at the expense of reliability. Finally, the effectiveness of wholesale electricity markets in practically achieving very high clean energy generation targets highly depends on the cost-competitiveness of clean energy technologies that can support critical balancing needs across multiple timescales.

capacity expansion↗

Wholesale Electricity Market Design to Support Resource Adequacy

Wholesale electricity markets are intended to incentivize system generation investments and operations outcomes that meet evolving system needs. In this work, we evaluate the effectiveness of wholesale market structures, rules and policies in achieving system resource adequacy (RA) and clean energy targets in the presence of self-interested generation investors using the Electricity Markets and Investment Suite Agent-based Simulation (EMIS-AS) model. Results highlight that both capacity markets and operating reserve demand curves (ORDCs) can help achieve a reliable system but with different RA compliance timelines and distribution of generation technologies. Structures with capacity markets tend to favor more capital-intensive peaking technologies while reducing wind and solar build-outs due to suppressed energy and clean energy market prices, particularly in the absence of strong clean energy targets. Conversely, ORDCs improve the commitment of available generation units, but this comes at the expense of higher system costs and renewable generation curtailment. We also find that well-calibrated static capacity demand curves can yield similar reliability and total cost compared to capacity market demand curves informed dynamically by resource adequacy while also yielding stable annual capacity prices. Different approaches to formulating ORDC curves can also yield key trade-offs, namely that a more efficient treatment of storage chronology results in lower ORDC curves and prices, yielding less investment and cost but at the expense of reliability. Finally, the effectiveness of wholesale electricity markets in practically achieving very high clean energy generation targets highly depends on the cost-competitiveness of clean energy technologies that can support critical balancing needs across multiple timescales.

agent based modeling↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

Probing molecular wavepacket evolution using multidimensional coherent spectroscopy (Final Report)

The goal of this project was to develop and demonstrate multidimensional coherent spectroscopy (MDCS) techniques to fully map wave-packet dynamics in simple molecules. MDCS correlates excitation and emis sion frequencies, enabling continuous tracking of wave-packet evolution even when multiple wave-packets evolve simultaneously. The initial experiments were to be performed using the MDCS apparatus in the PI’s laboratory to record the evolution of the wave-packet’s energy in molecular iodine. A longer-term goal was to develop a version compatible with using an X-ray Free Electron Laser (XFEL) as a probe, which would allow the evolution of the internuclear distance of the wave-packet—not just its energy—to be determined.

74 ATOMIC AND MOLECULAR PHYSICS↗

Detectability of Supermassive Dark Stars with the Roman Space Telescope

Abstract Supermassive dark stars (SMDS) are luminous stellar objects formed in the early Universe at redshift z ∼ 10–20, made primarily of hydrogen and helium, yet powered by dark matter. We examine the capabilities of the Roman Space Telescope (RST), and find it able to identify ∼10 6 M ⊙ SMDSs at redshifts up to z ≃ 14. With a gravitational lensing factor of μ ∼ 100, RST could identify SMDS as small as ∼10 4 M ⊙ at z ∼ 12 with ∼10 6 s exposure. Differentiating SMDSs from early galaxies containing zero metallicity stars at similar redshifts requires spectral, photometric, and morphological comparisons. With only RST, the differentiation of SMDS, particularly those formed via adiabatic contraction with M ≳ 10 5 M ⊙ and lensed by μ ≳ 100, is possible due to their distinct photometric signatures from the first galaxies. Those formed via dark matter capture can be differentiated only by image morphology: i.e., point object (SMDSs) versus extended object (sufficiently magnified galaxies). By additionally employing James Webb Space Telescope (JWST) spectroscopy, we can identify the He ii λ 1640 absorption line, a smoking gun for SMDS detection. Although RST does not cover the required wavelength band (for z emi ≳ 10), JWST does; hence, the two can be used in tandem to identify SMDS. The detection of SMDS would confirm a new type of star powered by dark matter and may shed light on the origins of the supermassive black holes powering bright quasars observed at z ≳ 6.

79 ASTRONOMY AND ASTROPHYSICS↗

Emerging Trends in Power System Planning Models

This presentation highlights NREL's power system modeling capabilities, both existing and the future direction of improvements. Specific enhancements to the ReEDS (Regional Energy Deployment System) model and a new electricity market design testbed called EMIS (Electricity Markets and Investment Suite) were described. This content was part of a broader discussion to help inform the National Academies of Sciences, Engineering, and Medicine Committee on the Future of Electric Power in the U.S. on existing power system models and improvements needed in these models to capture the increasing complexity and interconnectedness of the power system.

capacity expansion modeling↗

Soft-switching, high performance single-phase AC-DC converter

A soft-switching, high-performance single-phase alternating current (AC)-direct current (DC) converter is provided. The AC-DC converter described herein provides a new circuit topology for single-stage, single-phase or multi-phase AC-DC power conversion with power factor correction (PFC) and galvanic isolation using a high-frequency isolation transformer. The AC-DC converter improves power conversion efficiency and power density—two of the most important metrics for a power converter. It achieves soft switching for high frequency switches in the circuit, leading to higher efficiency and lower electromagnetic interference (EMI).

Ayyanar, Rajapandian↗

2.3.3.404 - National Lab and University Collaboration for MHK Instrumentation and Data Processing Tools

Field and laboratory validation, testing, demonstration, and operation are critical steps for increasing the technology readiness level of marine energy (ME) converters because they provide high-quality testing and performance data that are critical information used to feed all aspects of technology development. This project, in partnership with industry, enables the marine and hydrokinetic energy (MHK) community to reliably and efficiently collect, process, manage, and share quality data by facilitating access to and development of instrumentation, guidelines and data processing/QA tools. Under this project, open-source data processing code (MHKiT) and tools (ME Data Pipeline, MRE Code Hub, PRIMRE Code Catalog), instrumentation (loads measurements), data acquisition systems (miniDAQ), and measurement guidance tools (Telesto, high EMI guidance) were developed to facilitate the collection and processing of quality laboratory and field data. Overall, this project is intended to improve the quality of the data collected during laboratory and field demonstration projects by standardizing the collection and processing techniques, as well as by improving access to instrumentation, code, and measurement guidance. Quality data will, in turn, lead to improved knowledge capture following ME device testing.

data processing↗