Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Coulomb Excitation and One-Neutron Transfer Studies of Stable and Radioactive Nuclei at HRIBF-ORNL

Several stable and radioactive nuclei ranging from $A=58$ to 208 were recently studied in inverse kinematics by Coulomb excitation and heavy-ion induced one-neutron transfer at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory. These studies used a CsI-HPGe detector array to detect scattered charged particles and emitted $\gamma$ rays from the in-beam reactions. A Bragg-curve detector was used to measure the energy loss of the various beams through the targets and to measure the radioactive beam compositions. Stable nickel, strontium, zirconium, molybdenum, tin, tellurium, and lead isotopes and neutron-rich radioactive tin and tellurium isotopes were among the nuclei recently studied. Coulomb excitation was used to measure the electromagnetic moments of the first excited states and heavy-ion induced one-neutron transfer was used to measure the absolute cross sections and lifetimes of the excited single-particle states. A sample of these results are presented here with an emphasis on the tin isotopes. In particular, a survey of the Bragg-curve measurements, Doppler corrections, and inconclusive $i_{13/2}$ candidate in $^{133}$\textrm{Sn} are presented.

Allmond, James M↗

Sensing performance of sub-100-nm vanadium oxide films for room temperature thermal detection applications

Vanadium oxide films are widely employed as thermal detectors in uncooled infrared detection systems due to their high temperature coefficient of resistance near room temperature. One strategy toward maximizing detectivity and reducing the thermal time constant in these systems is to minimize the system platform dimensions. This approach necessitates thinner film thicknesses ([Formula: see text]100 nm), for which there is little information regarding thermal sensing performance. Herein, we report on the sensitivity of reactively sputtered vanadium oxide thin film resistive thermometers nominally ranging from 100 to 25 nm and assess the influence of thermal annealing. Here we demonstrate that films in this minimum limit of thickness maintain a high temperature coefficient while additionally providing an enhancement in characteristics of the noise equivalent power.

36 MATERIALS SCIENCE↗

A measurement technique to determine the calibration accuracy of an electromagnetic tracking system to radiation isocenter

Purpose: To present and characterize a measurement technique to quantify the calibration accuracy of an electromagnetic tracking system to radiation isocenter.Methods: This technique was developed as a quality assurance method for electromagnetic tracking systems used in a multi-institutional clinical hypofractionated prostate study. In this technique, the electromagnetic tracking system is calibrated to isocenter with the manufacturers recommended technique, using laser-based alignment. A test patient is created with a transponder at isocenter whose position is measured electromagnetically. Four portal images of the transponder are taken with collimator rotations of 45° 135°, 225°, and 315°, at each of four gantry angles (0°, 90°, 180°, 270°) using a 3 × 6 cm{sup 2} radiation field. In each image, the center of the copper-wrapped iron core of the transponder is determined. All measurements are made relative to this transponder position to remove gantry and imager sag effects. For each of the 16 images, the 50% collimation edges are identified and used to find a ray representing the rotational axis of each collimation edge. The 16 collimator rotation rays from four gantry angles pass through and bound the radiation isocenter volume. The center of the bounded region, relative to the transponder, is calculated and then transformed to tracking system coordinates using the transponder position, allowing the tracking system's calibration offset from radiation isocenter to be found. All image analysis and calculations are automated with inhouse software for user-independent accuracy. Three different tracking systems at two different sites were evaluated for this study.Results: The magnitude of the calibration offset was always less than the manufacturer's stated accuracy of 0.2 cm using their standard clinical calibration procedure, and ranged from 0.014 to 0.175 cm. On three systems in clinical use, the magnitude of the offset was found to be 0.053 ± 0.036, 0.121 ± 0.023, and 0.093 ± 0.013 cm.Conclusions: The method presented here provides an independent technique to verify the calibration of an electromagnetic tracking system to radiation isocenter. The calibration accuracy of the system was better than the 0.2 cm accuracy stated by the manufacturer. However, it should not be assumed to be zero, especially for stereotactic radiation therapy treatments where planning target volume margins are very small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time Lapse Charged Wellbore Casing Controlled Source Electromagnetic Surveys for Monitoring Injected Carbon Dioxide

Carbon dioxide (CO2) injection for enhanced oil recovery (EOR) and long-term carbon storage extends the life of an oil field while keeping CO2 out of the atmosphere. Monitoring CO2 migration during EOR operations is critical to maximizing production and detecting unexpected CO2 migration quickly. In this project, we monitor CO2 migration using time-lapse charged well casing controlled source electromagnetics (CSEM) at an active EOR site undergoing CO2 injection. Since the electrical conductivity of the reservoir changes as CO2 displaces other fluids, this novel survey technique aims to monitor CO2 injection effectively and unobtrusively from the surface via electromagnetic field measurements. Of four time-lapse field campaigns spaced over two years, we have completed two. Each campaign consists of a CSEM survey supplemented by magnetotelluric and time-domain electromagnetic surveys. In the CSEM survey, a transmitter delivers alternating current to the subsurface at frequencies from 0.125 Hz to 16 Hz using steel well casings as electrodes. Charged well casing surveys detect deeper conductivity contrasts than surveys that use only surface electrodes, allowing CO2 movement at the depth of the reservoir to be imaged more clearly. We transmit on two well pairs. One pair is oriented in the east-west direction, and the other is oriented in the northeast-southwest direction. Receiver stations measure orthogonal components of the electric and magnetic fields. The measurements are repeated at the same locations in each field campaign. Data differences between campaigns provide information about changes in the electrical conductivity of the subsurface. We present the latest results from this ongoing project, including modeling, survey design, data processing techniques, and preliminary results from the field campaigns.

Magnetic and electrical methods, Geomagnetic induc↗

Overview of recent results from the STAR experiment

We highlight the STAR experiment’s recent measurements on electromagnetic and hard probes of nuclear collisions, which inform the field’s understanding of these physical phenomena and by extension QCD. Results on vector meson production from the high electromagnetic fields in glancing heavy-ion collisions are presented. Observables related to jets, high-momentum hadrons, heavy quarks and quarkonia in vacuum and their modification in head-on heavy-ion collisions are also presented. Studies using electromagnetic probes of the medium created in these collisions are presented as well. Finally, we conclude and give an outlook for STAR data-taking and measurements in the coming years.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiative decay branching ratio of the Hoyle state

The triple-alpha process is a vital reaction in nuclear astrophysics, characterized by two consecutive reactions [2α ⇌ 8 Be (α, γ) 12 C] that drive carbon formation. The second reaction occurs through the Hoyle state, a 7.65 MeV excited state in 12 C with J π = 0 + . The rate of the process depends on the radiative width, which can be determined by measuring the branching ratio for electromagnetic decay. Recent measurements by Kibédi et al. conflicted with the adopted value and resulted in a significant increase of nearly 50% in this branching ratio, directly affecting the triple-alpha reaction. Here, this work aims to utilize charged-particle spectroscopy with magnetic selection as a means to accurately measure the total radiative branching ratio (Γ rad /Γ) of the Hoyle state in 12 C.

6 ≤ A ≤ 19↗

The Study of Electromagnetic Field Response Using Very Low Frequency Methods in Geothermal Area, Sabang

Electromagnetic field measurements have been performed using the method of Very Low Frequency tilt angle pattern in Jaboi, Sabang. A site survey was conducted and carried out to identify the anomalies of location, depth and geometry of hydrothermal based on tilt angle measurement and ellipse. Objective of this study is to see the response of the magnetic and electric field in relation to location, depth and hydrothermal geometry. The devices of T-VLF-R IRIS was used in this study, while the (NWC) station was selected as main station and (JJF4) station was selected as comparison station. The electromagnetic field survey was recorded for a line spanned as long as 900 meters at the interval of 10 meter depth. The results of this study show the greatest anomaly occurred at line interval between 400-600 meters with a depth of 10-140 meters. Anomaly pattern of each depth shows that the propagation pattern of hydrothermal is in the form of vertical pipe flow.

58 GEOSCIENCES↗

MARTA: a high-energy cosmic-ray detector concept for high-accuracy muon measurement

A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. Here, the combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CCUS Plume Monitoring: Verifying Surface CSEM Measurements to Log Scale Available

Conference presentation at Society of Petrophysicists and Well Log Analysts (SPWLA) 64th Annual Symposium, Lake Conroe, Texas, June 10–14, 2023. In carbon capture, utilization, and storage (CCUS) monitoring, dynamic plume monitoring and reservoir seal are key issues. Plume monitoring is best addressed with electromagnetics (sensitive to the resistivity contrast) and reservoir leakage with microseismics. A case history from North Dakota illustrates how we can tie surface-controlled source electromagnetic (CSEM) measurements to the three-dimensional (3D) anisotropic models derived from the available logs. This allows us to certify baseline measurements within the context of the borehole information.

20 FOSSIL-FUELED POWER PLANTS↗

The derivation of scaling relationship between acoustic and electromagnetic scattering by spheres

The rigorous theory of the conversion between the scattering of uniform plane electromagnetic wave by a perfectly conducting sphere and the scattering of uniform plane acoustic wave by a rigid sphere is studied in this paper. The conversion formula between these two different scattering based on two calibration curves is derived, which describes the quantitative relationship between acoustic and electromagnetic wave scattering at arbitrary frequencies by spheres of arbitrary sizes. In addition, the scaling relationship of the sizes of those two spheres and the corresponding frequencies are discussed in detail, and an indirect method of measurement of electromagnetic scattering by the spheres is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wireless Sensor Network for Electric Transmission Line Monitoring

Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform, it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver real-time information to federal agencies and others tasked with grid reliability (Tasks 6,8).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of charge state distributions using a scintillation screen

Absolute cross sections measured using electromagnetic devices to separate and detect heavy recoiling ions need to be corrected for charge state fractions. Accurate prediction of charge state distributions using theoretical models is not always a possibility, especially in energy and mass regions where data is sparse. As such, it is often necessary to measure charge state fractions directly. In this paper we present a novel method of using a scintillation screen along with a CMOS camera to image the charge dispersed beam after a set of magnetic dipoles. A measurement of the charge state distribution for 88 Sr passing through a natural carbon foil is performed. Using a Bayesian model to extract statistically meaningful uncertainties from these images, we find agreement between the new method and a more traditional method using Faraday cups. Additional future work is need to better understand systematic uncertainties. Our technique offers a viable method to measure charge state distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Drift Chamber Alignment using Cosmic Rays

The Collider Detector at Fermilab (CDF) is a general-purpose experimental apparatus with an inner tracking detector for measuring charged particles, surrounded by a calorimeter for measurements of electromagnetic and hadronic showers, and a muon detector system. We present a technique for, and results of, a precise relative alignment of the drift chamber wires of the CDF tracker. This alignment has been an important component of the track momentum calibration, which is the basis for the charged-lepton calibration for the measurement of the W boson mass at CDF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements and Alignment Results of LQXFA/B Cold Mass Assemblies at Fermilab

MQXFA production series quadrupole magnets are being built for the Hi-Lumi (HL) LHC upgrade by the U.S. Accelerator Upgrade Project (US-HL-LHC AUP). These magnets are being placed in pairs, as a cold mass, within cryostats at Fermilab, and are being tested to assess alignment and magnetic performance at Fermilab's horizontal test stand facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis position, and for magnet variations in positioning and local field profile. Here this paper describes the results of the magnetic and alignment measurements which characterize the first LQXFA/B assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the phase between strong and electromagnetic amplitudes in the decay J/ψ → ϕη

The first direct measurement of the relative phase between the strong and electromagnetic amplitudes for a J/ψ decaying into a vector-pseudoscalar final state is performed using 26 energy points of e + e − annihilation data between 3.00 GeV and 3.12 GeV. The data sets were collected by the BESIII detector with a total integrated luminosity of 452 pb −1 . By investigating the interference pattern in the cross section lineshape of e + e − → ϕη, the relative phase between the strong and electromagnetic amplitudes of J/ψ decay is determined to be within [133°, 228°] at 68% confidence level.

QCD↗

Electromagnetic Properties of (Gd, Y)Ba2Cu3Ox Superconducting Tapes With High Levels of Zr Addition

The dependence of the critical current density (J(c)) on the orientation of applied magnetic fields was studied in Zr-doped (Gd, Y)Ba2Cu3Ox tapes fabricated by metal organic chemical vapor deposition. The in-field performance of J(c) of (Gd, Y)Ba2Cu3Ox tapes with Zr-doping levels of 7.5-30 at.% was investigated up to 5 T over a temperature range of 40-77 K. The highest critical currents (I-c) at H parallel to c and the highest values of minimum Ic in angular dependence measurements were achieved in the tapes with 20% Zr doping over a broad range of temperature and magnetic field conditions measured. The electromagnetic properties have been related to the changes in BaZrO3 content and microstructure.

Liu, Y↗