An Edge-Intelligent, Clip-on Rogowski Current Sensor With Wide Dynamic Range
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Magnetostriction is a property of magnetic materials that causes them to change their shape or dimensions when their magnetization changes. Low-cost, mechanically robust magnetostrictive sensors would be valuable for a wide range of applications addressing DOE's energy, environmental, and national security missions. Several examples include monitoring internal conditions of pipelines, enhancing implantable systems for the human body, and improving the electrical grid by providing real time sensors for detecting high impedance faults that may act as ignition sources for forest fires. Historically, magnetostrictive materials tended to be expensive and mechanically brittle, but recent developments in iron-based alloys, especially those that include dilute solutions of rare earth elements, have demonstrated useful magnetostriction values, mechanical robustness, and low costs. This project investigated addition of dilute cerium doping on the magnetostrictive properties of Fe-Ga and Fe-Al alloys. Advanced manufacturing techniques were applied to these materials to take advantage of rapid cooling of the alloy to stabilize desired phases and to make near net shape coupons. These coupons develop significant texturing, offering a route to target microstructures with exceptional performance.
This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.
The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.
Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.
This paper explores the potential of distributed ledger technology (DLT) to improve fault-tolerant grid operations by leveraging its core features as an immutable, decentralized ledger, a distributed, consensus-based agreement process, and a distributed state-replication engine. Distribution power systems deliver electricity to millions of customers; however, they are susceptible to various threats that can result in customer interruptions. These include faults caused by adverse weather conditions, natural disasters, vegetation growth, equipment failure, and malicious attacks. To minimize the effects of these faults, fault-handling approaches rely on network knowledge to isolate affected areas and reconnect unaffected areas, reducing the number of affected customers while maintaining safety. Here, we present a trusted data-sharing architecture that enables independent, distributed actors to reconstruct the pre-fault system state by enabling distributed resources to make appropriate decisions with limited network/system information. Although the process requires some data sharing between switch-delimited areas, the approach limits the amount of private information shared, preserving customers' privacy and business-sensitive information. We include three use cases that form a foundation for third parties to develop functional solutions that can eventually be deployed in the field. The gross error detection method used within switch-delimited areas can identify sensor errors and accurately detect circuit breaker states. The evaluation of possible reconnection while preserving data ownership resulted in a voltage magnitude difference smaller than 0.001% from the OpenDSS power flow solution that has full system knowledge, which is below the expected power flow tolerance. The approach offers a promising opportunity for improving fault-tolerant distribution grid operations.
This project has aimed to achieve detailed electrical resistivity resolution at geothermal reservoir scales by combining airborne natural electromagnetic (EM) field surveying (ZTEM) with ground magnetotelluric (MT) measurements to approximate an airborne MT geophysical method. MT alone is relatively expensive and may have permitting challenges in sensitive areas. Airborne ZTEM field data contains only the magnetic field, requires a background assumption, and has been limited to relatively high frequencies, thus suffering uniqueness problems. Based on proto-type 2D simulations, ZTEM ambiguities may be reduced through formal incorporation with possibly sparse ground MT soundings, which we pursued in full 3D for this project. The methodology was tested at the high-temperature Roosevelt Hot Springs geothermal system, Utah, which was considered advantageous given the near total exposure of crystalline reservoir rocks across the project area. ZTEM and ground MT survey data were acquired in 2017, subcontracted to outside parties with which we have worked in the past. These included 80 remote-referenced tensor MT soundings over the Mineral Mountains and adjacent Roosevelt Hot Spring producing geothermal system. These MT stations abut later coverage of a similar number of MT stations taken for the Utah FORGE project providing excellent total data aperture to re-solve structure beneath both project areas better than either set alone. The airborne ZTEM survey covered 704 line kilometers in E-W flight lines with a 250 m line spacing. Although this survey was timed during a maintenance-related shutdown of power production at the Roosevelt Hot Springs, other noise sources difficult to identify but including two high-voltage state-scale transmission lines compromised the ZTEM survey badly leading to unusable responses. Thus, with DOE management concurrence, the project proceeded to emphasize inversion and interpretation of the joint SubTER-FORGE MT data sets with regard to the Roosevelt Hot Springs reservoir recharge and to deep heat sources for both it and the Utah FORGE EGS project area. We also investigated the joint ZTEM-MT sampling concept with data sets from the Eleven Mile Canyon prospect area donated by the U.S. Navy (A. Sabin, PoC). Inversion of the SubTER-FORGE MT data using the HexMT 3D finite element algorithm reveals a large, low-resistivity anomaly extending sub-vertically through the depth range of the crust beneath the western Mineral Mountains. The steep conductive zone connects in the lower crust to a more tabular conductor characteristic of much of the Great Basin that generally is ascribed to current mafic magmatic underplating, hybridization and fluid release. The location of the resolved anomaly relative to the recent (0.5-0.8 Ma) eruptive centers of the Mineral Mountains implicates it as remnants of the magma body which fed these centers. This structure appears to be currently feeding heat and fluids upward into the Roosevelt Hot Springs hydrothermal system, as well as heat laterally to the FORGE project area. Separate and joint inversion models were carried out for the donated Eleven Mile Canyon MT-ZTEM data set to demonstrate concept. ZTEM only inversion showed two main alteration zones in the western portion of the project area known from geological mapping. Joint inversion including an E-W profile of MT soundings sharpened these features considerably. It also resolved in much greater detail the graben related normal faulting structure of the central project area which lies at depths exceeding the sensitivity of ZTEM alone. The sparse number of MT da-ta relative to the ZTEM required upweighting the former by a factor of several, but an exact procedure awaits future research. Our final impression is that sparse MT data can improve resolution of the subsurface over that of ZTEM alone. However, well sampled MT data are to be preferred and offer the simplicity of interpreting just one data type, and possess the superior resolution capability coming with the electric field everywhere, and from their high bandwidth.
Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.
Phasor measurement units (PMU) are integral to the modernization and automation plan of the electric power industry. A PMU data signature contains system-level events (e.g., faults, generation/load change, etc.) and any measurement/device-related errors. Therefore, the reliable and resilient operation of power systems is equivalent to the quality of the PMU data and the situation awareness provided by its data signature. Despite recent progress, current state-of-the-art methods are not fool-proof and have certain limitations tracing an error/abnormality to sensor sub-components and grid systems. This is because of technical challenges imposed by the scarcity of the labeled information, loss of data quality, and non-stationarity of data. In this paper, we consider the online PMU data stream as an output of a stochastic process and pose the anomaly/event detection as a changepoint detection problem dealing with detecting parameter changes in the underlying stochastic processes. The proposed model-agnostic framework relies on: (a) feature extraction utilizing the minimum volume enclosing ellipsoids (MVEE) method from raw PMU observations and (b) a Bayesian framework of changepoint detection. The validity of the proposed methodology is discussed through numerical experiments on real-world utility-scale PMU data.
The future of the grid will be powered by AI—or undermined by it. Artificial intelligence is rapidly reshaping grid operations, improving fault detection, forecasting accuracy, and real-time optimization. As AI systems move closer to operational decision loops, however, they introduce new consequence pathways: expanded attack surfaces, model integrity risks, regulatory exposure, and human-automation challenges. This talk presents a consequence-driven framework for deploying AI responsibly in the electric grid. Attendees will gain practical strategies to strengthen resilience, boost reliability, and deploy AI securely — ensuring the grid of the future is not only smarter but safer.
A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.
Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.
Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.
A wireless-controlled smart plug device and methods of use and operation, using a solid state switch to provide electrical power from an outlet to a load, and provide protection against overload, short circuit, ground, arc, or voltage surge faults. The switch includes a bidirectional semiconductor switch with two back-to-back connected transistors, such as silicon power MOSFETs, silicon insulated-gate bipolar transistors (IGBTs), silicon carbide (SiC) transistors, or gallium nitride (GaN) transistors, each configured to control the current flow from the electrical receptacle to the external electrical load.
GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.
Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.
This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.
While traditional ferroelectrics are based on polar crystals in bulk or thin film form, two-dimensional and layered materials can support mechanisms for symmetry breaking between centrosymmetric building blocks, e.g., by creating low-symmetry interfaces in van der Waals stacks. Here, we introduce an approach toward symmetry breaking in van der Waals crystals that relies on the spontaneous incorporation of stacking faults in a nonpolar bulk layer sequence. The concept is realized in nanowires consisting of Se-rich group IV monochalcogenide (GeSe 1–x S x ) alloys, obtained by vapor–liquid–solid growth. The single crystalline wires adopt a layered structure in which the nonpolar A-B bulk stacking along the nanowire axis is interrupted by single-layer stacking faults with local A-A' stacking. Density functional theory explains this behavior by a reduced stacking fault formation energy in GeSe (or Se-rich GeSe 1–x S x alloys). Computations demonstrate that, similar to monochalcogenide monolayers, the inserted A-layers should show a spontaneous electric polarization with a switching barrier consistent with a Curie temperature above room temperature. Second-harmonic generation signals are consistent with a variable density of stacking faults along the wires. Here, our results point to possible routes for designing ferroelectrics via the layer stacking in van der Waals crystals.