Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EISA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Biofuels Information Center

The purpose of the Biofuels Information Center (BIC) task is to provide relevant data, information, reports, and web-based tools to all bioenergy stakeholders. The BIC task began in FY08 to meet the requirement under Title II, Sec. 229 of the Energy Independence and Security Act of 2007 (EISA) requires DOE to develop a "Biofuels and Biorefinery Information Center". The BIC task supports biofuels pages content on the EERE's most visited website - the Alternative Fuels Data Center (AFDC http://www.afdc.energy.gov) and the Bioenergy Atlas tools (currently archived) (previous address https://maps.nrel.gov). This task results in more than 1.7 million web pageviews (an instance of an internet user visiting a webpage) per year. In FY22, the task completed the final year of the 5 year USDA Biofuels Infrastructure Partnership (BIP). The USDA BIP expanded infrastructure for E15 and/or E85 to approximately 850 stations and NREL received and reviewed data for quality analyzed all infrastructure and sales data collected by USDA. Stations are privately held and previously it was difficult to ascertain infrastructure and sales data. This unique dataset allows insight into infrastructure data (number of pumps and tanks, costs to install new equipment) and sales data (price and volume for E10, E15, E85, and diesel by month). The 2021 USDA BIP National Summary Report is with DOE for review prior to publication. Future work will include the biannual Bioenergy Industry Status Report (4 previous versions have been published) . The task also supports the principal investigator's time to engage stakeholders on infrastructure and deployment of biofuels. This includes leading, membership, and participation in the following roles: member Board of Advisors at the Fuels Institute, voting member for multiple UL standards committees, Co-Chair of the Infrastructure team at Agriculture/Auto/Ethanol, Member of Coordination Research Council's ULSD Corrosion Committee. The Principal investigator routinely responds to industry inquires to assist in deployment of biofuels regularly.

biofuels↗

Ordered Mesoporous Silicon Through Magnesium Reduction of Polymer Templated Silica Thin Films

This paper describes the process of making ordered mesoporous silicon (Si) thin films. The process begins with mesoporous silica (SiO{sub 2}) thin films that are produced via evaporation induced self-assembly (EISA) using sol-gel silica precursors with a diblock copolymer template. This results in a film with a cubic lattice of 15 nm diameter pores and 10 nm thick walls. The silicon is produced through reduction of the silica thin films in a magnesium (Mg) vapor at 675 {sup o}C. Magnesium reduction preserves the ordered pore-solid architecture but replaces the dense silica walls with 10--17 nm silicon crystallites. The resulting porous silicon films are characterized by a combination of low and high angle X-ray diffraction, combined with direct SEM imaging. The result is a straightforward route to the production of ordered nanoporous silicon.

36 MATERIALS SCIENCE↗

Ethanol Blend Effects On Direct Injection Spark-Ignition Gasoline Vehicle Particulate Matter Emissions

Direct injection spark-ignition (DISI) gasoline engines can offer better fuel economy and higher performance over their port fuel-injected counterparts, and are now appearing increasingly in more U.S. vehicles. Small displacement, turbocharged DISI engines are likely to be used in lieu of large displacement engines, particularly in light-duty trucks and sport utility vehicles, to meet fuel economy standards for 2016. In addition to changes in gasoline engine technology, fuel composition may increase in ethanol content beyond the 10% allowed by current law due to the Renewable Fuels Standard passed as part of the 2007 Energy Independence and Security Act (EISA). In this study, we present the results of an emissions analysis of a U.S.-legal stoichiometric, turbocharged DISI vehicle, operating on ethanol blends, with an emphasis on detailed particulate matter (PM) characterization. Gaseous species, particle mass, and particle number concentration emissions were measured for the Federal Test Procedure urban driving cycle (FTP 75) and the more aggressive US06 cycle. Particle number-size distributions and organic to elemental carbon ratios (OC/EC) were measured for 30 MPH and 80 MPH steady-state operation. In addition, particle number concentration was measured during wide open throttle accelerations (WOTs) and gradual accelerations representative of the FTP 75. For the gaseous species and particle mass measurements, dilution was carried out using a full flow constant volume sampling system (CVS). For the particle number concentration and size distribution measurements, a micro-tunnel dilution system was employed. The vehicles were fueled by a standard test gasoline and 10% (E10) and 20% (E20) ethanol blends from the same supplier. The particle mass emissions were approximately 3 and 7 mg/mile for the FTP75 and US06, respectively, with lower emissions for the ethanol blends. During steady-state operation, the geometric mean diameter of the particle-number size distribution remained approximately the same (50 nm) but the particle number concentration decreased with increasing ethanol content in the fuel. In addition, increasing ethanol content significantly reduced the number concentration of 50 and 100 nm particles during gradual and WOT accelerations.

02 PETROLEUM↗

Single Metal Atom Catalysts Prepared by Diluted Atomic Layer Deposition

The scalable and facile preparation of single-atom catalysts remains a critical challenge. Here, in this study, we introduce diluted atomic layer deposition (DALD), a unique approach for synthesizing supported metal catalysts with precisely tunable loadings. Unlike conventional metal deposition by ALD which uses pure metal precursors, DALD employs a diluted precursor mixture, combining organometallic precursors with the corresponding free ligand in controlled ratios. The method enables precise control over metal loadings, allowing the synthesis of structures ranging from nanoparticles to isolated single atoms, as exemplified by Ir, Rh, and Pt on high-surface-area γ-Al 2 O 3 . With its inherent simplicity and exceptional efficiency in metal precursor utilization, DALD represents a highly scalable strategy, unlocking opportunities for integrating single-atom catalysts into industrial processes.

36 MATERIALS SCIENCE↗

Treatment of emerging contaminants in simulated wastewater via tandem photo-Fenton-like reaction and nutrient recovery

We report a tandem strategy that recovers NH 4 + and PO 4 3- nutrients from simulated wastewater in a solid form after the Fenton oxidation of emerging organic contaminants was developed. Mesoporous Cu–MgO nanoparticles were used as a photo-Fenton-like catalyst to oxidize paraoxon and tetracycline present in nutrient-rich simulated wastewater to prevent their incorporation into the struvite product. Mesoporous MgO nanoparticles were subsequently used as the Mg-source for the struvite crystallization due to the fast intraparticle diffusion and adsorption kinetics facilitated by their porosity and the high surface area. Without Fenton oxidation, 13% of paraoxon and 37% of tetracycline were incorporated into the struvite, demonstrating the clear need for the removal of hazardous contaminants before struvite synthesis. Both organic contaminants were eliminated using the Fenton oxidation reaction, with some minor non-toxic intermediate products formed. The product formed after the tandem process was shown by XRD and Raman spectroscopy to be struvite free of the emerging organic contaminants.

54 ENVIRONMENTAL SCIENCES↗

The quantum equations of state of plasma under the influence of a weak magnetic field

The aim of this paper is to calculate the magnetic quantum equations of state of plasma, the calculation is based on the magnetic binary Slater sum in the case of low density. We consider only the thermal equilibrium plasma in the case of n{lambda}{sub ab}{sup 3} Much-Less-Than 1, where {lambda}{sub ab}{sup 2}=( Planck-Constant-Over-Two-Pi {sup 2}/m{sub ab}KT) is the thermal De Broglie wave length between two particles. The formulas contain the contributions of the magnetic field effects. Using these results we compute the magnetization and the magnetic susceptibility. Our equation of state is compared with others.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT

Purpose: At present, no established methods exist for dosimetry in micro computed tomography (micro-CT). The purpose of this study was therefore to investigate practical concepts for both dosimetric scanner quality assurance and tissue dose assessment for micro-CT. Methods: The computed tomography dose index (CTDI) was adapted to micro-CT and measurements of the CTDI both free in air and in the center of cylindrical polymethyl methacrylate (PMMA) phantoms of 20 and 32 mm diameter were performed in a 6 month interval with a 100 mm pencil ionization chamber calibrated for low tube voltages. For tissue dose assessment, z-profile measurements using thermoluminescence dosimeters (TLDs) were performed and both profile and CTDI measurements were compared to Monte Carlo (MC) dose calculations to validate an existing MC tool for use in micro-CT. The consistency of MC calculations and TLD measurements was further investigated in two mice cadavers. Results: CTDI was found to be a reproducible quantity for constancy tests on the micro-CT system under study, showing a linear dependence on tube voltage and being by definition proportional to mAs setting and z-collimation. The CTDI measured free in air showed larger systematic deviations after the 6 month interval compared to the CTDI measured in PMMA phantoms. MC calculations were found to match CTDI measurements within 3% when using x-ray spectra measured at our micro-CT installation and better than 10% when using x-ray spectra calculated from semi-empirical models. Visual inspection revealed good agreement for all z-profiles. The consistency of MC calculations and TLD measurements in mice was found to be better than 10% with a mean deviation of 4.5%. Conclusions: Our results show the CTDI implemented for micro-CT to be a promising candidate for dosimetric quality assurance measurements as it linearly reflects changes in tube voltage, mAs setting, and collimation used during the scan, encouraging further studies on a variety of systems. For tissue dose assessment, MC calculations offer an accurate and fast alternative to TLD measurements allowing for dose calculations specific to any geometry and scan protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

Facilitating Sound, Cost-Effective Energy Management (Fact Sheet)

FEMP focuses on the needs of its Federal customers, delivering an array of products grouped into project transaction services, applied technology services, and decision support services. This document outlines FEMP services and programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Uncertainty of Fischer-Tropsch Jet Fuel Life Cycle Inventories with Monte Carlo Simulation [Slides]

This presentation discusses the use of Monte Carlo simulation to model the uncertainty in a life cycle inventory of the Gasification Systems of coal and biomass. While the inventory is dominated by carbon dioxide emissions from the Adv. Combustion Systems of the fuel, small changes to the feedstocks that are used to make the fuel can make the difference in complying with the Energy Independence and Security Act of 2007.

01 COAL, LIGNITE, AND PEAT↗

Leading by Example with Smart Energy Management (Fact Sheet)

The Federal Energy Management Program facilitates the Federal Government?s implementation of sound, cost-effective energy management and investment practices to enhance the nation?s energy security and environmental stewardship. FEMP does this by focusing on the needs of its Federal customers, delivering an array of products grouped into project transaction services, applied technology services, and decision support services. This document outlines FEMP services and programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗