Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EEG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Multichannel Brain-Signal-Amplifying and Digitizing System

An apparatus has been developed for use in acquiring multichannel electroencephalographic (EEG) data from a human subject. EEG apparatuses with many channels in use heretofore have been too heavy and bulky to be worn, and have been limited in dynamic range to no more than 18 bits. The present apparatus is small and light enough to be worn by the subject. It is capable of amplifying EEG signals and digitizing them to 22 bits in as many as 150 channels. The apparatus is controlled by software and is plugged into the USB port of a personal computer. This apparatus makes it possible, for the first time, to obtain high-resolution functional EEG images of a thinking brain in a real-life, ambulatory setting outside a research laboratory or hospital.

Gevins, Alan↗

Physiological Characterization of Language Comprehension

In this project, our goal was to develop methods that would allow us to make accurate predictions about individual differences in human cognition. Understanding such differences is important for maximizing human and human-system performance. There is a large body of research on individual differences in the academic literature. Unfortunately, it is often difficult to connect this literature to applied problems, where we must predict how specific people will perform or process information. In an effort to bridge this gap, we set out to answer the question: can we train a model to make predictions about which people understand which languages? We chose language processing as our domain of interest because of the well- characterized differences in neural processing that occur when people are presented with linguistic stimuli that they do or do not understand. Although our original plan to conduct several electroencephalography (EEG) studies was disrupted by the COVID-19 pandemic, we were able to collect data from one EEG study and a series of behavioral experiments in which data were collected online. The results of this project indicate that machine learning tools can make reasonably accurate predictions about an individual?s proficiency in different languages, using EEG data or behavioral data alone.

42 ENGINEERING↗

MIDAS: Modeling Individual Differences using Advanced Statistics

This research explores novel methods for extracting relevant information from EEG data to characterize individual differences in cognitive processing. Our approach combines expertise in machine learning, statistics, and cognitive science, advancing the state-of-the art in all three domains. Specifically, by using cognitive science expertise to interpret results and inform algorithm development, we have developed a generalizable and interpretable machine learning method that can accurately predict individual differences in cognition. The output of the machine learning method revealed surprising features of the EEG data that, when interpreted by the cognitive science experts, provided novel insights to the underlying cognitive task. Additionally, the outputs of the statistical methods show promise as a principled approach to quickly find regions within the EEG data where individual differences lie, thereby supporting cognitive science analysis and informing machine learning models. This work lays methodological ground work for applying the large body of cognitive science literature on individual differences to high consequence mission applications.

97 MATHEMATICS AND COMPUTING↗

Some sequential, distribution-free pattern classification procedures with applications

Some sequential, distribution-free pattern classification techniques are presented. The decision problem to which the proposed classification methods are applied is that of discriminating between two kinds of electroencephalogram responses recorded from a human subject: spontaneous EEG and EEG driven by a stroboscopic light stimulus at the alpha frequency. The classification procedures proposed make use of the theory of order statistics. Estimates of the probabilities of misclassification are given. The procedures were tested on Gaussian samples and the EEG responses.

Poage, J. L.↗

Electroencephalographic monitoring of complex mental tasks

Outlined here is the development of neurophysiological procedures to monitor operators during the performance of cognitive tasks. Our approach included the use of electroencepalographic (EEG) and rheoencephalographic (REG) techniques to determine changes in cortical function associated with cognition in the operator's state. A two channel tetrapolar REG, a single channel forearm impedance plethysmograph, a Lead I electrocardiogram (ECG) and a 21 channel EEG were used to measure subject responses to various visual-motor cognitive tasks. Testing, analytical, and display procedures for EEG and REG monitoring were developed that extend the state of the art and provide a valuable tool for the study of cerebral circulatory and neural activity during cognition.

Guisado, Raul↗

Functional relationships among monitoring performance: Subjective report of thought process and compromising states of awareness

A biocybernetic system for use in adaptive automation was evaluated using EEG indices based on the beta, alpha, and theta bandwidths. Subjects performed a compensatory tracking task while their EEG was recorded and one of three engagement indices was derived: beta/(alpha + theta), beta/alpha, or 1/alpha. The task was switched between manual and automatic modes as a function of the subjects' level of engagement and whether they were under a positive or negative feedback condition. It was hypothesized that negative feedback would produce more switches between manual and automatic modes, and that the beta/(alpha + theta) index would produce the strongest effect. The results confirmed these hypotheses. There were no systematic changes in these effects over three 16-minute trials. Tracking performance was found to be better under negative feedback. An analysis of the different EEG bands under positive and negative feedback in manual and automatic modes found more beta power in the positive feedback/manual condition and less in the positive feedback/automatic condition. The opposite effect was observed for alpha and theta power. The implications of biocybernetic systems for adaptive automation are discussed.

Freeman, Frederick↗

NASA Graduate Student Researchers Program (GSRP)

The primary area of research that Dr. Prinzel conducted was concerned with the effects of automation on the ability to perform various tasks which simulated those performed in an airplane cockpit. While automation is generally considered to be a positive addition to the cockpit, it also has some negative effects. The primary negative effect is related to the decrease in the number of tasks the pilot needs to perform. Having less to do can actually result in a decreased ability to be aware of and react to ongoing events, some of which may be critical to flight operations. The research was concerned with the ability of adaptive automation using psychophysiological measures, specifically brain waves (i.e. EEG), to control the degree to which tasks are automated as a function of the subject's level of alertness. Dr. Prinzel conducted and participated in the running of a number of experiments that examined adaptive automation in conjunction with the MultiAttribute Task Battery. Since there has been very little research conducted in this area, experiments needed to be conducted which established basic parameters for future research. The experiments that Dr. Prinzel was involved with examined the optimum number and location of electrode sites for recording EEG, the types of tasks which could readily be automated, the number of tasks which could be controlled by the adaptive automation system, and various EEG recording parameters which affect system functioning. A secondary area in which Dr. Prinzel conducted research concerned performance on vigiliance tasks. This research, while not initially directly related to adaptive automation, does have implication for such systems. Vigilance requires long term monitoring which often leads to the kind of negative effects seen when automation is introduced into a work environment. A third area of research in which Dr. Prinzel conducted research was concerned with gender differences in cognitive functioning and how that related to strategies for performing various tasks.

Freeman, Frederick G.↗

External Validity Considerations of a Biocybernetic System for Adaptive Automation

The report discusses the results of a research project aimed at generating a software application library termed the DAQ EEG Processor (or DEP) that collects and processes raw electroencephalographic data. The purpose of this system is to reduce raw EEG data in real time into information that is useful to researchers, such as power bands and indices of engagement. DEP improves upon existing EEG processing systems in that it can be seamlessly integrated into many software development environments to provide realtime data. DEP takes advantage of Microsoft Corporation's Component Object Model Technology (COM), which, in short, allows language independent, inter-application communication and transfer of data. According to the COM specification, COM objects can be written in different languages, run in different process spaces and on different platforms. As long as the objects adhere to the specification, they can communicate.

Scerbo, Mark W.↗

Psychophysiological Control of Acognitive Task Using Adaptive Automation

The major focus of the present proposal was to examine psychophysiological variables related to hazardous states of awareness induced by monitoring automated systems. With the increased use of automation in today's work environment, people's roles in the work place are being redefined from that of active participant to one of passive monitor. Although the introduction of automated systems has a number of benefits, there are also a number of disadvantages regarding worker performance. Byrne and Parasuraman have argued for the use of psychophysiological measures in the development and the implementation of adaptive automation. While both performance based and model based adaptive automation have been studied, the use of psychophysiological measures, especially EEG, offers the advantage of real time evaluation of the state of the subject. The current study used the closed-loop system, developed at NASA-Langley Research Center, to control the state of awareness of subjects while they performed a cognitive vigilance task. Previous research in our laboratory, supported by NASA, has demonstrated that, in an adaptive automation, closed-loop environment, subjects perform a tracking task better under a negative than a positive, feedback condition. In addition, this condition produces less subjective workload and larger P300 event related potentials to auditory stimuli presented in a concurrent oddball task. We have also recently shown that the closed-loop system used to control the level of automation in a tracking task can also be used to control the event rate of stimuli in a vigilance monitoring task. By changing the event rate based on the subject's index of arousal, we have been able to produce improved monitoring, relative to various control groups. We have demonstrated in our initial closed-loop experiments with the the vigilance paradigm that using a negative feedback contingency (i.e. increasing event rates when the EEG index is low and decreasing event rates when the EEG index is high) results in a marked decrease of the vigilance decrement over a 40 minute session. This effect is in direct contrast to performance of a positive feedback group, as well as a number of other control groups which demonstrated the typical vigilance decrement. Interestingly, however, the negative feedback group performed at virtually the same level as a yoked control group. The yoked control group received the same order of changes in event rate that were generated by the negative feedback subjects using the closed-loop system. Thus it would appear to be possible to optimize vigilance performance by controlling the stimuli which subjects are asked to process.

Freeman, Frederick↗

Assessment of Cognitive Processing by Multiple Sclerosis Patients Using Electroencephalographic Energy Density Analysis

Recent neuropsychological studies demonstrate that cognitive dysfunction is a common symptom in patients with multiple sclerosis. In many cases the presence of cognitive impairment affects the patient's daily activities to a greater extent than would be found due to their physical disability alone. Cognitive dysfunction can have a significant impact on the quality of life of both the patient and that of their primary caregiver. Two cognitively impaired male MS patients were given a visual discrimination task before and after a one hour cooling period. The subjects were presented a series of either red or blue circles or triangles. One of these combinations, or one fourth of the stimuli, was designated as the "target" presentation. EEG was recorded from 20 scalp electrodes using a Tracor Northern 7500 EEG/ERP system. Oral and ear temperatures were obtained and recorded manually every five minutes during the one hour cooling period. The EEG ERP signatures from each series of stimuli were analyzed in the energy density domain to determine the locus of neural activity at each EEG sampling time. The first subject's ear temperature did not decrease during the cooling period. It was actually elevated approximately 0.05C by the end of the cooling period compared to his mean of control period value. In turn, Subject One's discrimination performance and cortical energy remained essentially the same after body cooling. In contrast, Subject Two's ear temperature decreased approx. 0.8C during his cooling period. Subject Two's ERROR score decreased from 12 during the precooling control period to 2 after cooling. His ENERGY value increased approximately 300%, from a precooling value of approximately 200 to a postcooling value of nearly 600.

Montgomery, Leslie D.↗

Enhancement of Cognitive Processing by Multiple Sclerosis Patients Using Liquid Cooling Technology: A Case Study

Recent neuropsychological studies demonstrate that cognitive dysfunction is a common symptom in patients with multiple sclerosis. In many cases the presence of cognitive impairment affects the patient's daily activities to a greater extent than would be found due to their physical disability alone. Cognitive dysfunction can have a significant impact on the quality of life of both the patient and that of their primary caregiver. Two cognitively impaired male MS patients were given a visual discrimination task before and after a one hour cooling period. The subjects were presented a series of either red or blue circles or triangles. One of these combinations, or one fourth of the stimuli, was designated as the "target" presentation. EEG was recorded from 20 scalp electrodes using a Tracor Northern 7500 EEG/ERP system. Oral and ear temperatures were obtained and recorded manually every five minutes during the one hour cooling period. The EEG ERP signatures from each series of stimuli were analyzed in the energy density domain to determine the locus of neural activity at each EEG sampling time. The first subject's ear temperature did not decrease during the cooling period. It was actually elevated approximately 0.05 C by the end of the cooling period compared to his mean of control period value. In turn, Subject One's discrimination performance and cortical energy remained essentially the same after body cooling. In contrast, Subject Two's ear temperature decreased approx. 0.8 C during his cooling period. Subject Two's ERROR score decreased from 12 during the precooling control period to 2 after cooling. His ENERGY value increased approximately 300%, from a precooling value of approximately 200 to a postcooling value of nearly 600. These findings might be interpreted by the following three-part hypothesis: (1) the general cognitive impairment of MS patients may be a result of low or unfocused metabolic energy conversion in the cortex; (2) such differences show up most strongly in reduced energy in the occipital region during the initial processing of the precooling period visual stimulus which may indicate impaired early visual processing; and (3) increased postcooling activation in the le ft angular gyrus may result in enhanced higher-level reasoning related to processing visual task information. By this hypothesis the superior performance of Subject Two following body cooling may be a result of increased neural activation in his early visual recognition and processing centers.

Montgomery, Leslie D.↗

Rheoencephalographic and electroencephalographic measures of cognitive workload: analytical procedures

This investigation demonstrates the feasibility of mental workload assessment by rheoencephalographic (REG) and multichannel electroencephalographic (EEG) monitoring. During the performance of this research, unique testing, analytical and display procedures were developed for REG and EEG monitoring that extend the current state of the art and provide valuable tools for the study of cerebral circulatory and neural activity during cognition. REG records are analyzed to provide indices of the right and left hemisphere hemodynamic changes that take place during each test sequence. The EEG data are modeled using regression techniques and mathematically transformed to provide energy-density distributions of the scalp electrostatic field. These procedures permit concurrent REG/EEG cognitive testing not possible with current techniques. The introduction of a system for recording and analysis of cognitive REG/EEG test sequences facilitates the study of learning and memory disorders, dementia and other encephalopathies.

Arousal/physiology↗

Allopregnanolone as an Adjunct Therapy to Midazolam is More Effective Than Midazolam Alone in Suppressing Soman‐Induced Status Epilepticus in Male Rats

ABSTRACT Aims Humans and animals acutely intoxicated with the organophosphate soman can develop sustained status epilepticus (SE) that rapidly becomes refractory to benzodiazepines. We compared the antiseizure efficacy of midazolam, a current standard of care treatment for OP‐induced SE, versus combined therapy with midazolam and allopregnanolone (ALLO) in a rat model of soman‐induced SE. Methods Soman‐intoxicated male rats with robust seizure behavior and high‐amplitude electroencephalographic (EEG) activity were administered midazolam (0.65 mg, i.m.) 20 min after seizure initiation and 10 min later either a second dose of midazolam or ALLO (12 or 24 mg/kg, i.m.). Seizure behavior and EEG were monitored for 4 h after treatment. Brains were collected at the end of the monitoring period for histological analyses. Results Animals receiving 2 doses of midazolam exhibited persistent SE. Sequential dosing with midazolam followed by ALLO suppressed electrographic seizure activity. The combination therapy also significantly reduced soman‐induced neurodegeneration and neuroinflammation compared to 2 doses of midazolam. High but not low dose ALLO was associated with transitory and reversible respiratory compromise during the 1 h period after dosing. Conclusions Treatment with midazolam followed by ALLO was more effective than 2 doses of midazolam in suppressing benzodiazepine‐refractory, soman‐induced SE, and in mitigating its acute neuropathological consequences.

Andrew, Peter M. [Department of Molecular Bioscien↗

Eight-channel telephone telemetry system

Portable telemetry system uses conventional telephone link which eliminates mailing or messenger service between physician and analyst. Transmitter is used by physician; receiver is used by analyst. Each unit is inductively coupled to its respective telephone set, transmitter converting EEG into audio frequency and receiver converting this frequency back to EEG.

Smith, R.↗

Application of frequency discrimination technique to the analysis of electroencephalographic signals

A frequency discrimination technique is realized by an inexpensive frequency discriminator for direct on-line measurement of the entrainment phenomenon in EEG as entrained by the frequency of a sensory stimulus. The use of this device for detecting the presence or absence of the stimulus effect and the measurement of the time delays in the entrainment is demonstrated. The EEG signal is first filtered by a narrow-band filter with center frequency about the alpha-rhythm of the individual. It is then reasonable to consider the alpha signal as narrow-band random process with the alpha frequency f sub alpha as the mean frequency of the spectral band.

Lai, D. C.↗

Eight channel telephone telemetry system

A portable, indirectly coupled telephone system is reported which transmits/to a central receiving site eight channels of EEG data of sufficient fidelity for screening and/or limited diagnostic use. The system requires no electrical connection to the telephone at the transmitter or at the receiver and is compatible with common EEG recording practice for real-time recording. It accepts 8 input channels simultaneously with one telephone transmitter and one telephone receiver operates from standard power sources.

Smith, R. E.↗

Bioelectric signal analysis and measurement

Nonstationary time series techniques are used to analyze EEG signals for the estimation of alertness. A time varying order is extracted in sequential time series measurement of these data and strategies are devised for obtaining optimal representation of the EEG signal.

Lai, D. C.↗

Biocybernetic factors in human perception and memory

The objective of this research is to develop biocybernetic techniques for use in the analysis and development of skills required for the enhancement of concrete images of the 'eidetic' type. The scan patterns of the eye during inspection of scenes are treated as indicators of the brain's strategy for the intake of visual information. The authors determine the features that differentiate visual scan patterns associated with superior imagery from scan patterns associated with inferior imagery, and simultaneously differentiate the EEG features correlated with superior imagery from those correlated with inferior imagery. A closely-coupled man-machine system has been designed to generate image enhancement and to train the individual to exert greater voluntary control over his own imagery. The models for EEG signals and saccadic eye movement in the man-machine system have been completed. The report describes the details of these models and discusses their usefulness.

Lai, D. C.↗