Analytical formulation of proton dose rates behind spherical multilayer shields
Analytical formulation of proton dose rates behind spherical multilayer shielding for calculation of body, skin, depth, and local proton dosage
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Analytical formulation of proton dose rates behind spherical multilayer shielding for calculation of body, skin, depth, and local proton dosage
This report discusses a preliminary assessment of the capabilities of current state-of-the-art stochastic codes Shift and MCNP6 to calculate the ex-core radiation dose rates for a simplified Molten Salt Reactor (MSR) model. The Monte Carlo code Shift has been under significant development in recent years at ORNL as part of the CASL program and is now supported by NEAMS. Originally, Shift was developed for LWR ex-core calculations but with dose rate and shielding calculations specifically requested by the NEAMS program’s MSR industry partners, the MSR Application Drivers team was tasked with assessing Shift for non-LWR applications. This was the first application of the Shift code for non-LWRs and the findings can be considered preliminary due to the activities occurring only over a 5-month period. Attractive features of Shift include massive parallelization and advanced automated variance reduction techniques such as CADIS and FW-CADIS.
Disruption of phase stability by energetic particle bombardment is a major challenge in designing advanced radiation-tolerant alloys and ion beam processing of nanocomposites. Particularly, ballistic dissolution susceptibility of different solute nanocluster species in alloys is poorly understood. Here, low dose rate neutron irradiations were conducted on a Fe-Cr-Ni based austenitic steel in the BOR-60 reactor (9.4 × 10 -7 dpa/s, 318 °C) followed by accelerated dose rate ion irradiations at multiple temperatures ( 10 -3 dpa/s, 380 – 420 °C). Using atom probe tomography, the stability of radiation-enhanced Cu-rich and radiation-induced Ni-Si-Mn-rich nanoclusters was evaluated. During neutron irradiation, Cu-rich clusters nucleated with their core concentrations progressively increasing with dose, while Ni-Si-Mn-rich clusters formed and evolved into G-phase precipitates. Ion irradiations dramatically altered the nanoclusters. Cu-rich clusters were ballistically dissolved, but Ni-Si-Mn-rich clusters remained stable and coarsened with dose at 400 and 420 °C, highlighting that different nanocluster species in a single microstructure can have innately distinct ballistic dissolution susceptibilities. Solute-specific recoil rates were incorporated into the Heinig precipitate stability model, which shows that in addition to radiation-enhanced diffusion, recovery from ballistic dissolution depends on solute concentration gradient near cluster interfaces. Finally, the combined experimental-modeling study quantified the critical temperatures and damage rates where ballistic dissolution dominates for each cluster species.
Low-dose-rate (LDR) brachytherapy and stereotactic body radiation therapy (SBRT) have both shown acceptable outcomes in the treatment of low- and intermediate-risk prostate cancer. Minimal data have been published directly comparing rates of biochemical control and toxicity with these 2 modalities. We hypothesize that LDR and SBRT will provide similar rates of biochemical control.
Body-centered cubic (BCC) Fe-based alloys are promising candidate materials for advanced nuclear reactors. A widespread perception is that the addition of Cr favors the formation of ½ <111> dislocation loops. However, the Cr effects on dislocation loop formation/evolution remain unclear due to the limited experimental studies. In this study, we irradiate ultra-high purity bulk BCC Fe-xCr (x = 3, 5, and 8 wt%) with 6.7-8 MeV Fe ions over a wide range of temperatures (Tirr = 250-500 °C) and dose rates (10⁻⁵ to 10⁻³ dpa/s) to two midrange doses (0.35 and 3.5 dpa). The major irradiation-induced microstructures are loop decoration along non-screw dislocation lines at low temperatures and high dose rates as well as self-assembled loops at elevated temperatures. Post-irradiation Burgers vector analysis via g•b method on loops and electron tomography reveals that <001> preponderance is observable in all irradiated Fe-Cr samples at elevated temperature, resulting from stronger elastic energy originating from <001> edge.
Rad-hard CMOS/bulk inverters with input gates high and low were irradiated by protons with a nominal energy of 8 MeV in an effort to determine the total-dose and dose-rate dependence of threshold voltage shifts, both during and immediately after irradiation and over extended periods of time thereafter. It is shown that the effects in rad-hard MOS devices which are produced by specific proton and electron energies in the space environment could be simulated by cobalt-60 induced effects through careful and proper selection of total does and dose rates. This selection must be based on an experimentally established relationship of Co-60 to electron or proton damage. It is demonstrated that the simulation can be accomplished both during and after irradiation, in the long-term postirradiation period, as well as in the damage state immediately after bombardment.
Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.
Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.
Primary and secondary proton dose rates in tissue spheres and slabs
Cr-rich alpha prime precipitates (CrRP) induce hardening and embrittlement of FeCr alloys, but the kinetics of CrRP formation due to particle irradiation are not well understood. In this study, Fe18wt.%Cr alloy in solid solution state and pre-aged to produce relatively coarse CrRP was irradiated with 8 MeV Fe ions. The irradiation conditions involved two midrange doses of 0.37 and 3.7 displacements per atom (dpa), a wide range of dose rates (10 -5 –10 -3 dpa/s) and temperatures (300–450 °C). The distributions of CrRP after irradiation were studied with atom probe tomography (APT). The critical irradiation conditions to suppress CrRP formation were identified as 300 °C and 10-3 dpa/s; CrRP formation occurred readily at lower dose rates or higher temperatures. From 0.37 to 3.7 dpa, CrRP were observed to slightly grow at 350 °C and strongly coarsen at 450 °C. Specimens with pre-existing CrRP evolved into a similar precipitate distribution as detected after ion irradiation on solution annealed specimens at 300–350 °C to 0.37 dpa, indicating that the precipitate microstructure approaches a quasi-equilibrium for doses <1 dpa. Limited shrinking of pre-existing CrRP was observed after irradiation at 450 °C to 0.37 dpa, indicating a higher recovery rate at this temperature. Additionally, the evolution of CrRP is quantitatively explained by employing corrections to the historic Nelson-Hudson-Mazey precipitate stability model, and a radiation modified precipitation mechanism is proposed to account for the competition between radiation enhanced diffusion and ballistic dissolution which results in the modifications on both size and solute concentration of CrRP.
Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.
Ground based solar proton monitoring, considering particle intensities and radiation dose rates from riometer absorption as function of time
We evaluate the low dose rate sensitivity in several families of discrete bipolar transistors across device parameter, quality assurance level, and irradiation bias configuration. We discuss the implications of the results for radiation hardness assurance
The target carriage supports the mercury target vessel in the Spallation Neutron Source (SNS) in a cantilevered fashion and supplies the liquid mercury flowing to and from the target vessel. The target carriage is designed to move the target vessel into its target monolith position to receive the proton beam and then remove it horizontally back into an adjacent service cell, where the target vessel can be exchanged about 2-3 times per calendar year. At the time of the performed studies, the SNS mercury target can accept a proton beam at 1 GeV energy and 1.4 MW power; however, it will be upgraded to receive 1.3 GeV energy at 2 MW by the end of 2024 year [1]. The cart is practically a shield block on wheels to minimize fluxes and dose rates in the service cell downstream of the carriage. There are vent lines located inside a passage on top of the target carriage, and they are covered by a stepping-up steel shield block (vent lines shield block). Vent lines are permanently attached to the shield block. New vent lines with a different design are going to be installed. These lines are shielded by the new steel block to which the vent lines are attached. The estimate of the residual dose rates from the block after it is extracted from the target carriage is performed to estimate the radiation fields and to decide on the type of storage container to be used.
Nickel-based alloys offer exceptional mechanical properties and corrosion resistance for various applications in extreme environments such as high neutron flux, temperature, and stress. Precipitates, resulting from thermal treatments, increase the strength and creep resistance of these alloys. Here, heavy ion irradiation is shown to destabilize the γ' and γ" precipitates in Inconel 718 nickel-based alloy by disordering and dissolution processes. Transmission electron microscopy and atom probe tomography reveal that the disordering and dissolution rates of the precipitates are proportional to both irradiation dose and dose rate. Irradiation induced disordering occurs at a higher rate than the dissolution. From analyzing the hardening contributions, microscale mechanical results suggest radiation-induced disordering is responsible for the majority of the softening response at low dose. In addition, low dose radiation-induced disordering results in strain localization and is believed to be the primary cause for the drastic degradation of uniform elongation and toughness in irradiated Inconel 718.
A prospective phase 2 study was conducted to evaluate the feasibility and safety of single-application multifractionated (SA-MF), high-dose-rate (HDR), image guided adaptive brachytherapy (IGABT) for cervical cancer.
To report the long-term outcome of patients with prostate cancer treated with external beam radiation therapy and high dose rate (HDR) brachytherapy from a prospective multi-institutional trial conducted by NRG Oncology/RTOG.
We report efficacy of a prospective phase 2 trial (NCT00450411) of salvage low-dose-rate (LDR) prostate brachytherapy (BT) for local failure (LF) after prior external beam radiation therapy (EBRT) with minimum 5-years’ follow-up.