Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Individual doses for super cohort members exposed to atmospheric radioiodine from the Mayak releases with an emphasis on prenatal doses

Time-dependent thyroid doses were reconstructed for 45,837 members of the Southern Urals Population Exposed to Radiation Cohort (SUPER-C) living in the region around the Mayak Production Association facilities in Russia from 131I released to the atmosphere from all relevant exposure pathways. The dose calculations are implemented in a Monte Carlo framework that produces best estimates and stochastic realizations of dose time-histories. The mean thyroid dose from 131I for SUPER-C members was 195 mGy; the median was 65 mGy. Overall, 131I-thyroid doses for about 3.6% of SUPER-C members were larger than 1 Gy. For children born in 1940-1950, the dose was about 10% higher than in previous studies because doses during the prenatal period for 9,117 individuals are included in the current work. Half of the individuals born in the region in 1950–1960 who remained in the study domain through 1972 received 9.4% or more of their total dose during the prenatal period. SUPER-C members residing in areas contaminated by discharges of liquid radioactive releases into the Techa River and the Kyshtym Accident in 1957 received 80% of their thyroid dose from airborne 131I emissions. The uncertainty in the 131I dose estimates is low enough for this approach to be used in regional epidemiological studies.

Dose assessment, 131I, airborne radioactivity, thy↗

Update of the Nuclear Criticality Slide Rule Calculations: Plutonium systems – Delayed Fission Gamma

IRSN (France), LLNL (USA) and ORNL (USA) began a long-term collaboration effort in 2015 to update the nuclear criticality Slide Rule for the emergency response to a nuclear criticality accident. The Slide Rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, as a function of distance from the fission source, and time after criticality accidents for different critical systems. This paper presents results from the fourth phase of the current update of the Slide Rule project, in which delayed fission-product gamma (DFG) dose rates of unreflected plutonium critical systems were compared by several modern 3D radiation transport codes (MCNP, COG, SCALE), using updated flux-to-dose conversion factors. Dose rates are calculated for fissile material at five moderation ratios (H/Pu), at 1 m above the ground as a function of distance (between 30 cm and 1,200 m) from the external surface of the source to the center of the detector, and for periods between 1 s and 1,000 min after the critical instantaneous event. Further efforts have been devoted to the determination of the delayed gamma source, by comparing the time-dependent energy spectra obtained from several methods. Overall, DFG dose rates calculated by each participant led to consistent results. Extra effort is under way to identify the cause of the remaining differences, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Epidemiological Studies of Low-Dose Ionizing Radiation and Cancer: Rationale and Framework for the Monograph and Overview of Eligible Studies

Abstract Whether low-dose ionizing radiation can cause cancer is a critical and long-debated question in radiation protection. Since the Biological Effects of Ionizing Radiation report by the National Academies in 2006, new publications from large, well-powered epidemiological studies of low doses have reported positive dose-response relationships. It has been suggested, however, that biases could explain these findings. We conducted a systematic review of epidemiological studies with mean doses less than 100 mGy published 2006–2017. We required individualized doses and dose-response estimates with confidence intervals. We identified 26 eligible studies (eight environmental, four medical, and 14 occupational), including 91 000 solid cancers and 13 000 leukemias. Mean doses ranged from 0.1 to 82 mGy. The excess relative risk at 100 mGy was positive for 16 of 22 solid cancer studies and 17 of 20 leukemia studies. The aim of this monograph was to systematically review the potential biases in these studies (including dose uncertainty, confounding, and outcome misclassification) and to assess whether the subset of minimally biased studies provides evidence for cancer risks from low-dose radiation. Here, we describe the framework for the systematic bias review and provide an overview of the eligible studies.

Berrington de Gonzalez, Amy↗

Methods to Track Effective Doses from Airborne Radioactive Emissions for Compliance with 40 CFR 61, SUBPART H

US Department of Energy national laboratories can play an integral role in not only the advancement of science but also in the treatment of various medical conditions through research and development activities conducted at radioisotope production facilities. Here, a project has been underway at Oak Ridge National Laboratory since 2016 whose mission is to produce and supply the radioisotope 227 Ac, which is used in a radiopharmaceutical developed to treat certain types of prostate cancer and bone metastases. Production activities result in the environmental release of airborne radioactive emissions, which are governed by Clean Air Act regulations described in 40 CFR Part 61, Subpart H. Stack 3039, the source that emits radioactive effluents from 227 Ac production, is subject to additional requirements outlined in American National Standards Institute (ANSI) N13.1-1969 due to its grandfathered status. Radioactive emissions are limited to levels below those that would cause annual compliance dose standards for members of the public to be exceeded and stack 3039 to lose its grandfathered status. To allow for maximum production of 227 Ac without exceeding relevant dose limits, monthly tracking of project emissions and resulting CAP88-PC modeled effective doses to a maximally exposed individual have been implemented. Four years of tracking data were compiled and analyzed to identify additional methods that could be used to estimate project doses more frequently, potentially further optimizing 227 Ac production while maintaining compliance with applicable regulations.

atmospheric emissions↗

Update of the Nuclear Criticality Slide Rule: Review of the Estimation of the Number of Fissions

IRSN (France), LLNL (USA) and ORNL (USA) began a long-term collaboration effort in 2015 to update the nuclear criticality Slide Rule (https://ncsp.llnl.gov/analytical-methods/criticality-sliderule) for the emergency response to a nuclear criticality accident. The Slide Rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, as a function of distance from the fission source, and time after criticality accidents for different critical systems. This paper presents the review of the section “estimation of the number of fissions”, named “fission yield” in the Slide Rule document. This estimation is important because the other information provided by the Slide Rule is directly proportional to the number of fissions. The previous models, based on Hansen and Barbry formulae, will be presented with their associated assumptions and limitations. Then, new proposals will be presented with a comparison to past criticality accidents and experimental data. The new formulae, based on the heat energy equation, cover many types of criticality accidents (solution, dry or low-moderated powder, rods/assemblies in water and dry metal) and require limited information in an emergency situation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dose Exceedance Distance Sensitivity Based on Parametric Uncertainty

Sandia National Laboratories (SNL) collaborated with the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Security and Incident Response (NSIR) and Office of Nuclear Regulatory Research (RES) to investigate the reasonable variability in the estimation of dose exceedance distances. SNL performed calculations using the MACCS code to elucidate the sensitivity of dose exceedance distances to variations in user input parameters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose reconstruction for plutonium-239 intakes at the Rocky Flats Plant

Purpose: The Rocky Flats (RF) Plant was a weapons manufacturing facility that operated from the early 1950s to 1989. Its primary missions were the production of plutonium (Pu) pits for thermonuclear weapons and the processing of retired weapons for Pu recovery. The purpose of this study was to estimate radiation doses to a cohort of 4499 RF workers from an intake of 239 Pu, the primary plutonium isotope handled at the site. Materials and methods: The latest biokinetic models of the International Commission on Radiological Protection, or site-specific variations of those models, were used to estimate 239 Pu intakes for each worker based on model fits to bioassay data often coupled with lung measurements. Results: Urinary excretion and lung retention data for most 239 Pu intakes could be fit reasonably well by a mixture of Pu dioxide and moderately soluble material. For some workers, better fits were obtained by application of other absorption types including Type S, 239 Pu nitrate, or pure 239 Pu dioxide, or by assuming intake via a wound. The lungs typically received the highest tissue doses, with fifty-year committed equivalent doses in the range of 0.5–1 Sv for 275 workers, 1–5 Sv for 115 workers, and greater than 5 Sv for 12 workers. Conclusions: RF was a unique site regarding a large number of lung measurements available for determining the appropriate absorption types for inhaled material. Further, this provided higher confidence in reconstructed 239 Pu doses than is generally gained from urinary data alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the Determination of the Radiation Doses at Hiroshima [Slides]

Essentially all knowledge regarding the chronic effects of radiation exposure is derived from statistical analyses of the survivors of Hiroshima and Nagasaki. However, we were then, and are now, uncertain about the exposures. That is: We know the effects through observations and statistical analyses, but we can only estimate the doses. Other complications include the fact that Little Boy was truly unique. It was never tested, measurements of yield were ambiguous, calculations of yield were not consistent, and calibration measurements were not made, could not be made.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preclinical studies of a PARP targeted, Meitner-Auger emitting, theranostic radiopharmaceutical for metastatic ovarian cancer

Advanced ovarian cancer currently has few therapeutic options. Poly(ADP-ribose) polymerase (PARP) inhibitors bind to nuclear PARP and trap the protein-inhibitor complex to DNA. This work investigates a theranostic PARP inhibitor for targeted radiopharmaceutical therapy of ovarian cancer in vitro and PET imaging of healthy mice in vivo. Methods: [ 77 Br]RD1 was synthesized and assessed for pharmacokinetics and cytotoxicity in human and murine ovarian cancer cell lines. [ 76 Br]RD1 biodistribution and organ uptake in healthy mice were quantified through longitudinal PET/CT imaging and ex vivo radioactivity measurements. Organ-level dosimetry following [ 76/77 Br]RD1 administration was calculated using RAPID, an in-house platform for absorbed dose in mice, and OLINDA for equivalent and effective dose in human. Results: The maximum specific binding (B max ), equilibrium dissociation constant (K d ), and nonspecific binding slope (NS) were calculated for each cell line. These values were used to calculate the cell specific activity uptake for cell viability studies. The half maximal effective concentration (EC 50 ) was measured as 0.17 (95 % CI: 0.13–0.24) nM and 0.46 (0.13–0.24) nM for PARP(+) and PARP(–) expressing cell lines, respectively. The EC 50 was 0.27 (0.21–0.36) nM and 0.30 (0.22–0.41) nM for BRCA1(–) and BRCA1(+) expressing cell lines, respectively. When measuring the EC 50 as a function of cellular activity uptake and nuclear dose, the EC 50 ranges from 0.020 to 0.039 Bq/cell and 3.3–9.2 Gy, respectively. Excretion through the hepatobiliary and renal pathways were observed in mice, with liver uptake of 2.3 ± 0.4 %ID/g after 48 h, contributing to estimated absorbed dose values in mice of 19.3 ± 0.3 mGy/MBq and 290 ± 10 mGy/MBq for [ 77 Br]RD1 and [ 76 Br]RD1, respectively. Conclusion: [ 77 Br]RD1 cytotoxicity was dependent on PARP expression and independent of BRCA1 status. Finally, the in vitro results suggest that [ 77 Br]RD1 cytotoxicity is driven by the targeted Meitner-Auger electron (MAe) radiotherapeutic effect of the agent. Further studies investigating the theranostic potential, organ dose, and tumor uptake of [ 76/77 Br]RD1 are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Deformation and Fracture Mechanisms in the Harvested High-Dose Baffle-Former Bolt with Stress-Corrosion Cracks Formed While in Service

This report presents the results of advanced mechanical testing conducted on miniature tensile specimens excised from an irradiated baffle-former bolt, a commercial pressurized water reactor component. The specimens were extracted from the midsection of the bolt shank, where the estimated damage dose reached 23 displacements per atom. The mechanical testing included the following tests: (1) conventional tensile testing at room temperature, augmented by digital image correlation (DIC) to enable noncontact strain measurements, and (2) in situ tensile testing within a scanning electron microscopy (SEM) instrument equipped with energy-dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD) detectors to evaluate active deformation and fracture mechanisms. Additionally, SEM fractographic analysis revealed alterations in the fracture mechanism from a predominantly ductile fracture in nonirradiated steel to a mixed fracture mode (still dominating ductile and minor cleavage spots) in irradiated specimens derived from the baffle bolts. The findings indicate a complex strain localization behavior for in-service irradiated steel specimens. Beyond conventional necking at the macro scale and defect-free channel formation at the micro scale, DIC results identified the presence of deformation bands approximately 100 μm in width. These bands consist of chains of grains exhibiting elevated local strain levels and may be considered an intermediate or mesoscale level of strain localization. These bands become discernible near the yield stress as localized hot spots, areas of elevated strain, persisting throughout most of the experiment. The formation of mesoscale deformation bands as a strain localization mechanism may exacerbate the defect-free channel formation in irradiated materials, further promoting irradiation-assisted stress corrosion crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Generation of Beamline Sources – Preliminary Design (Second Target Station (STS) Project)

This report provides a short summary of how four neutron beamline sources at the US Department of Energy’s Oak Ridge National Laboratory were generated for use in shielding and activation analysis along Second Target Station (STS) neutron beamlines, inside and outside the bunker, and inside instrument caves. Analysis of these sources shows that an angular acceptance of ±2° from the axis of the neutron beamline is all that is needed to accurately model dose rates for these applications. Further analysis shows that the surface area of the tallies used to calculate these sources, and therefore the number of particles in the sources (normalization), should be scaled up to ~19 × 19 cm to provide conservative estimates of dose rate outside the bunker. The spectrum of neutrons entering beamline 11 (ST11), which has the hardest spectrum at high energies and the most neutrons below 100 eV, produces the largest prompt dose rates inside and outside the bunker and the largest number of activation products inside the bunker, therefore, producing the largest residual dose rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Attila Transport Code with MCNP in the Analysis of Small Modular Reactor Shielding

Of great importance in the design of a nuclear power plant is the evaluation of shielding from the ionizing radiation produced in the core of the nuclear reactor. This requires simulation software to predict the dose rates in the areas of interest. These problems are referred to as deep penetration problems, as they involve the reduction of a radiation field by two or three orders of magnitude or more. This makes accurate analyses difficult for Monte Carlo based solutions that rely on enough particles being sampled in an area of interest. Comparing the simulation of the same modeled system with more than one computer application, especially one that uses a different algorithmic approach, is a way to gain confidence in the results. In this research, two models were created, one in Monte Carlo N Particle (MCNP) which uses a stochastic algorithmic approach, and the other in Attila, which uses a deterministic algorithmic approach to test the validity of the model and to estimate the dose rates in the area of interest. Successful comparison of the two models is a way we can validate the model used for that estimation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pre- and post-treatment image-based dosimetry in 90 Y-microsphere radioembolization using the TOPAS Monte Carlo toolkit

Objective.To evaluate the pre-treatment and post-treatment imaging-based dosimetry of patients treated with 90Y-microspheres, including accurate estimations of dose to tumor, healthy liver and lung. To do so, the Monte Carlo (MC) TOPAS platform is in this work extended towards its utilization in radionuclide therapy. Approach. In this study, five patients treated at the Massachusetts General Hospital were selected for this study. All patients had data for both pre-treatment SPECT-CT imaging using 99mTc-MAA as a surrogate of the 90Y-microspheres treatment and SPECT-CT imaging immediately after the 90Y activity administration. Pre- and post-treatment doses were computed with TOPAS using the SPECT images to localize the source positions and the CT images to account for tissue inhomoegeneities. We compared our results with analytical calculations following the voxel-based MIRD scheme. Main results. TOPAS results largely agreed with the MIRD-based calculations in soft tissue regions: the average difference in mean dose to the liver was 0.14 Gy GBq -1 (2.6%). However, dose distributions in the lung differed considerably: absolute differences in mean doses to the lung ranged from 1.2 to 6.3 Gy GBq -1 and relative differences from 153% to 231%. We also found large differences in the intra-hepatic dose distributions between pre- and post-treatment imaging, but only limited differences in the pulmonary dose. Significance. Doses to lung were found to be higher using TOPAS with respect to analytical calculations which may significantly underestimate dose to the lung, suggesting the use of MC methods for 90Y dosimetry. According to our results, pre-treatment imaging may still be representative of dose to lung in these treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conversion of Site-Specific Meteorological Data for use in CAP-88 PC

CAP-88 PC is a commonly used radiological atmospheric dispersion model. This US EPA-approved model is used to demonstrate compliance with atmospheric emission regulations for radionuclides. While the model includes a large library of meteorological data for use across the United States, there are applications when users may wish to use onsite meteorological data as an input to the CAP-88 PC model. Here, in this work, we present a work-around process for preparing and converting onsite data for use in CAP-88 PC. However, the use of local data should provide a more realistic estimate of doses to members of the public in the immediate vicinity of a facility, although the regulatory agency having jurisdiction may not accept the use of local data for compliance. Additionally, the historical meteorological records from 20+ years ago (at a site many kilometers away) might not be representative of current local weather patterns, highlighting another benefit of using local meteorological data.

54 ENVIRONMENTAL SCIENCES↗

The effects of chronic diseases on plutonium urinary excretion in former workers of the Mayak Production Association

The radiochemical analysis of plutonium activity in urine is the main method for indirect estimation of doses of internal exposure from plutonium incorporation in professional workers. It was previously shown that late-in-life acute diseases, particularly those that affect the liver, can promote accelerated rates of release of plutonium from the liver with enhanced excretion rates. This initial study examines the relationships of some chronic diseases on plutonium excretion as well as the terminal relative distribution of plutonium between the liver and skeleton. Fourteen cases from former workers at the Mayak Production Association (Mayak PA) who provided from 4–9 urine plutonium bioassays for plutonium, had an autopsy conducted after death, and had sufficient clinical records to document their health status were used in this study. Enhanced plutonium excretion was associated with more serious chronic diseases, including cardiovascular diseases and other diseases that involved the liver. These chronic diseases were also associated with relatively less plutonium found in the liver relative to the skeleton determined by analyses conducted after autopsy. These data further document health conditions that affect plutonium biokinetics and organ deposition and retention patterns and suggest that health status should be considered when conducting plutonium bioassays as these may alter subsequent dosimetry and risk models.

60 APPLIED LIFE SCIENCES↗

Processing Meteorological Data for the CAP-88 PC Model at Los Alamos National Laboratory

The Environmental Protection and Compliance-Compliance Programs (EPC-CP) group at Los Alamos National Laboratory (LANL) uses the Clean Air Act Assessment Package 1988 (CAP-88, Littleton 2020) PC model (Version 4.1) to estimate radiological doses for a set of areal sectors surrounding a release location, in order to satisfy the Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAP) dose calculation requirement in 40 CFR 61 Subpart H. Among several types of data that must be prepared for CAP-88 input is a text file of meteorological data (“WIND” file), consisting of the joint frequency of wind direction, wind speed, and atmospheric stability categories. EPC-CP produces customized WIND files by running a CAP-88 utility program on a user generated text file of wind data in a different format, known as a STability ARray (STAR) file (Turner, 1964). At LANL, EPC-CP meteorologists prepare customized STAR files with data over desired time periods at selected meteorological towers. A custom program written in Precision Visuals -Workstation Analysis and Visualization Environment (PV-WAVE), a commercial Fortran-like language, is used to read LANL meteorological data and write a STAR file; the executable filename is “Star.out”. However, the outdated PV-WAVE utility program is being phased out by EPC-CP, due to the inefficient process to run it and an inability to modify the code. To preserve the ability to create customized meteorological data for CAP-88 in a way that will be easy to use and maintain, a new replacement utility program, written in the Python programming language, has been developed. The new, improved program reads a data file from any LANL meteorological tower, and at each desired observation time, determines the wind direction, wind speed, and stability categories defined in the CAP-88 documentation. The frequencies of all combinations of the three sets of categories are calculated and written to a file in the STAR format, which can later be converted to a WIND file for input into CAP-88.

54 ENVIRONMENTAL SCIENCES↗