Selection of Distribution Feeders for Implementing Distributed Generation and Renewable Energy Applications
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract not provided.
Abstract Not Provided
Abstract not provided.
Abstract not provided.
Abstract not provided.
Comprehensive paper laying out the foundation of the residential solar pv permitting process, outlining bottlenecks, and describing a framework for a long-term solution.
A method for detecting and preventing islanding includes issuing a command to an inverter connected to a power source, where the inverter is coupled to a power grid and supplies power to the power grid, the command causes a frequency of a waveform output by the inverter to vary, and the frequency of the waveform output by the inverter is a command frequency, determining that a amount of change of the command frequency is a constant value for a predetermined amount of time, removing the power supplied by the inverter from the power grid, and determining whether the power grid is valid.
Given the need for clean and reliable energy, fuel cell technologies offer the ability to produce extremely low-emission electricity from reliable fossil energy. A standalone solid oxide fuel cell (SOFC) module can reach electrical efficiencies of about 60%. However, coupling a SOFC to a Brayton style gas turbine (GT) increases the efficiency of the system to 70-75% or more. Using results from NETL’s HYPER Lab and published research, this project evaluates the strengths, limitations, and potential applications of SOFC-GT hybrids.
Presented by NETL at 2017 Fuel Cell Seminar and Exposition, 11/17
Abstract not provided.
This presentation highlights the key developments of the ARAP-e NODES project, including the innovative real-time optimal power flow (RT-OPF) algorithm for distributed energy resource (DER) management, trip planning for T+D coordination, and extensive validation of the RT-OPF algorithm in NREL ESIF laboratory with 100+ physical hardware devices, controller-hardware-in-the-loop test at Southern California Edison (SCE), and two field demonstrations.
A circuit for a smart photovoltaic (PV) inverter system and the smart PV inverter system are described. The circuit includes one or more strings coupled to an electrical load. Each of the one or more strings further includes one or more string members coupled in series, where each of the one or more string members comprises a voltage source and an inverter. The circuit also includes a controller to receive an output from an operator controller and control the strings, where the controller is configured to control the strings by providing a function command to a first string member of each of the one or more strings based on the output from the operator controller. The voltage source may also receive an output from an energy output device. Further, the inverter may be configured to convert the output of energy output device into an energy source of electrical load.
This presentation provides an overview of REopt Lite, and how it can be used to evaluate the economic and resilience benefits of hybrid systems.
Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating potential PV impacts.