Medically related activities of application team program

Application team methodology identifies and specifies problems in technology transfer programs to biomedical areas through direct contact with users of aerospace technology. The availability of reengineering sources increases impact of the program on the medical community and results in broad scale application of some bioinstrumentation systems. Examples are given that include devices adapted to the rehabilitation of neuromuscular disorders, power sources for artificial organs, and automated monitoring and detection equipment in clinical medicine.

Source record↗

Biotelemetry and computer analysis of sleep processes on earth and in space.

Developments in biomedical engineering now permit study of states of sleep, wakefulness, and focused attention in man exposed to rigorous environments, including aerospace flight. These new sensing devices, data acquisition systems, and computational methods have also been extensively applied to clinical problems of disordered sleep. A 'library' of EEG data has been prepared for sleep in normal man, and characterized for its group features by computational analysis. Sleep in an astronaut in space flight has been examined for the first and second 'nights' of space flight. Normal 90-min cycles were detected during the second night. Sleep patterns in quadriplegic patients deprived of all sensory inputs below the neck have indicated major deviations.

Adey, W. R.↗

Optical, spin-resonance, and magnetoresistance studies of /tetrathiatetracene/2/iodide/3 - The nature of the ground state

A recent investigation in which Isett and Perez-Albuerne (1977) found that (tetrathiatetracene)2(iodine)3 is a stable organic metal down to 3.3 K is of considerable interest. In view of the diversity of suggestions made regarding this compound, measurements, were made of its electrical, magnetic, and optical properties. The results obtained indicate a metallic state at high temperatures, but also support a nonmetallic state at temperatures below 30 K. At 20-30 K, a metal-to-insulator phase transition occurs. This is indicated by the onset of a large and positive magnetoresistance, the leveling off in the temperature dependence of the ESR linewidth, and by recent derivative analysis of the electrical conductivity in this region. The investigated compound represents an interesting one-dimensional electronic system in which it may be possible to study the combined effects of disorder and interchain coupling on charge transport processes.

Somoano, R. B.↗

Space Radiation

Astronauts receive the highest occupational radiation exposure. Effective protections are needed to ensure the safety of astronauts on long duration space missions. Increased cancer morbidity or mortality risk in astronauts may be caused by occupational radiation exposure. Acute and late radiation damage to the central nervous system (CNS) may lead to changes in motor function and behavior, or neurological disorders. Radiation exposure may result in degenerative tissue diseases (non-cancer or non-CNS) such as cardiac, circulatory, or digestive diseases, as well as cataracts. Acute radiation syndromes may occur due to occupational radiation exposure.

Wu, Honglu↗

The Galactic Cosmic Ray Simulator at the NASA Space Radiation Research Laboratory

With NASA’s new Artemis plan for a sustainable return to the moon, astronauts will once again leave Earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR). The ever penetrating GCR will continue to pose significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, and degenerative tissue effects including circulatory and heart disease. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the “GCR simulator” to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle.

NASA Space Radiation Laboratory↗

Recent insights into instability and transition to turbulence in open-flow systems

Roads to turbulence in open-flow shear layers are interpreted as sequences of often competing instabilities. These correspond to primary and higher order restructurings of vorticity distributions which culminate in convected spatial disorder (with some spatial coherence on the scale of the shear layer) traditionally called turbulence. Attempts are made to interpret these phenomena in terms of concepts of convective and global instabilities on one hand, and of chaos and strange attractors on the other. The first is fruitful, and together with a review of mechanisms of receptivity provides a unifying approach to understanding and estimating transition to turbulence. In contrast, current evidence indicates that concepts of chaos are unlikely to help in predicting transition in open-flow systems. Furthermore, a distinction should apparently be made between temporal chaos and the convected spatial disorder of turbulence past Reynolds numbers where boundary layers and separated shear layers are formed.

Morkovin, Mark V.↗

Disorder to Order in Interface Patterns: Thermal Noise to Limit Cycle Transition in Dendrite Sidebranch Formation

Thin sample directional solidification experiments have been carried out in the model succinonitrile-camphor system to examine the origin of secondary branches in dendrite morphologies. Thermal noise at the dendrite tip creates interface instabilities which amplify to form sidebranches. This is accepted as the primary mode of sidebranching in dendritic growth from an undercooled melt and occurs in directional solidification of dendrites. The proposed limit cycle couples the growth of the tip with the initiation of the sidebranch. Directional solidification of curved interfaces is a driven dissipative system with the potential to form a limit cycle. Two sets of experiments were performed, the first holding velocity constant and evolving the gradient and the second imposing oscillating velocities around the natural period of sidebranching. Both experimental methods were found to characterize a transition from disordered sidebranching induced by thermal noise to ordered sidebranching produced by the limit cycle mechanisms. This is the first quantitative measurement of previously hypothesized limit cycle growth. These experiment sets have been quantitatively analyzed for dynamic behavior seen in limit cycles. High-quality data sets of the tip and instability enable the measurement of the FFT and analysis through a power spectrum. At low gradients, the sidebranches are found to be excited by thermal noise far away from the tip. As the gradient increases and velocity is held constant, the distance between the instability and tip decreases until limit cycle growth is found between the tip of the primary dendrite and the first forming sidebranch. An alternative to the deterministic limit cycles seen in experiments of gradient evolution is a limit cycle actively driven through the square wave oscillation of velocity. Crucial observations of the solidified microstructure conclude that this produced periodic interconnected bridges between the primary dendrites. This is a finding with potentially significant implications for commercial applications.

Trevor Lyons↗

Photons, clocks, and consciousness

Light profoundly impacts human consciousness through the stimulation of the visual system and powerfully regulates the human circadian system, which, in turn, has a broad regulatory impact on virtually all tissues in the body. For more than 25 years, the techniques of action spectroscopy have yielded insights into the wavelength sensitivity of circadian input in humans and other mammalian species. The seminal discovery of melanopsin, the photopigment in intrinsically photosensitive retinal ganglion cells, has provided a significant turning point for understanding human circadian phototransduction. Action spectra in humans show that the peak wavelength sensitivity for this newly discovered sensory system is within the blue portion of the spectrum. This is fundamentally different from the three-cone photopic visual system, as well as the individual rod and cone photoreceptor peaks. Studies on rodents, nonhuman primates, and humans indicate that despite having a different wavelength fingerprint, these classic visual photoreceptors still provide an element of input to the circadian system. These findings open the door to innovations in light therapy for circadian and affective disorders, as well as possible architectural light applications.

Review↗

Formation, Structure and Properties of Amorphous Carbon Char from Polymer Materials in Extreme Atmospheric Reentry Environments

Amorphous carbonaceous char produced from the pyrolysis of polymer solids has many desirable properties for ablative heat shields for space vehicles. Molecular dynamics simulations are presented to study the transformation of the local atomic structure from virgin polymer to a dense, disordered char [1]. Release of polymer hydrogen is found to be critical to allow the system to collapse into a highly coordinated char structure. Mechanisms of the char formation process and the morphology of the resulting structures are elucidated. Thermal conductivity and mechanical response of the resulting char are evaluated [2]. During reenty, the optical response and oxidative reactivity of char are also important properties. Results of ab initio computations of char optical functions [3] and char reactivity [4] are also presented.

Lawson, John W.↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances could include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We will investigate temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We will also determine whether the vestibular organs and/or the central vestibular system undergo structural changes during long-duration exposure to microgravity, which could cause vestibular disorders when transitioning to a different gravitational environment. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, will be used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. Pre-flight data will be collected 90 days before the flight. In-flight tests will be performed early in the mission and once every one or two months thereafter. Post-flight examinations will be performed on the following days after return (R) from the mission: R+0, R+4, R+9, and R+30. Ground-based control tests will be performed on healthy volunteers in the laboratory to estimate mean normative responses. CONTROL RESULTS Thirty-two healthy (non-astronaut) control subjects performed the same ground test procedures as planned for crewmembers. In addition to establishing a normative database, these data were used to calculate vestibular asymmetries from perceptual reports during unilateral centrifugation, oculomotor responses during visual-alignment tasks, vestibulo-ocular reflex gain during head-impulse tests, and body rotation during stepping tests. A significant correlation was observed between asymmetries of subjective visual vertical and verbal report during unilateral centrifugation. Another significant correlation was observed between the asymmetries of ocular alignment, vestibulo-ocular reflex gain, and body rotation. These findings in a healthy cohort may help us better understand changes in vestibular asymmetries in crewmembers during and following spaceflight. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises. ACKNOWLEDGEMENT This work is supported by the NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances can include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We will investigate temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We will also determine whether the vestibular organs and/or the central vestibular system undergo structural changes during long-duration exposure to microgravity, which could cause vestibular disorders when transitioning to a different gravitational environment. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, will be used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. Pre-flight data will be collected 90 days before launch. In-flight examinations will be performed early in the mission (Flight Days 1 and 30) and once every two or three months thereafter. Post-flight examinations will be performed on the following days after return (R) from the mission: R+0, R+4, R+9, and R+30. Ground-based control tests have been performed on healthy volunteers in the laboratory to estimate mean normative responses. RESULTS Data collection for this study is ongoing. Data processing techniques are being refined. Our eye tracking method for measuring three-dimensional eye movement takes advantage of modern computer vision software (OpenCV) and advances in the field of iris recognition to improve measurement of ocular-counterolling. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises.

T R Macaulay↗

Photoreceptor System for Melatonin Regulation and Phototherapy

The present invention involves a light system for stimulating or regulating neuroendocrine, circadian, and photoneural systems in mammals based upon the discovery of peak sensitivity ranging from 425-505 nm; a light meter system for quantifying light which stimulates or regulates mammalian circadian, photoneural, and neuroendocrine systems. The present invention also relates to translucent and transparent materials, and lamps or other light sources with or without filters capable of stimulating or regulating neuroendocrine, circadian, and photoneural systems in mammals. Additionally, the present invention involves treatment of mammals with a wide variety of disorders or deficits, including light responsive disorders, eating disorders, menstrual cycle disorders, non-specific alerting and performance deficits, hormone-sensitive cancers, and cardiovascular disorders.

Brainard, George↗

Carbon Nanofiber Nanoelectrodes for Biosensing Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

bioinstrumentation↗

Carbon Nanofiber Nanoelectrodes for Neural Stimulation and Chemical Detection: The Era of Smart Deep Brain Stimulation

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable "smart" therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

bioinstrumentation↗

Carbon Nanofiber Nanoelectrodes for Neural Stimulation and Chemical Detection: The Era of "Smart" Deep Brain Stimulation

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

human body↗

Carbon Nanofiber Electrode Array for Neurochemical Monitoring

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report using vertically aligned CNF as neurotransmitter recording electrodes for application in a smart deep brain stimulation (DBS) device. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Koehne, Jessica E.↗

Nanobiotechnology in Space Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable "smart" therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Koehne, Jessica E.↗

Carbon Nanomaterials for Biosensing Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable “smart” therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Carbon Nanomaterials for Biosensing Applications↗