Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Synchrotron-based diffraction-enhanced imaging and diffraction-enhanced imaging combined with CT X-ray imaging systems to image seeds at 30 keV

Utilized the upgraded Synchrotron-based non-destructive Diffraction-enhanced imaging and Diffraction-enhanced imaging coupled with CT X-ray imaging systems to image the chickpea seeds, to enhance the contrast in plant root architecture, visibility of fine structures of root architecture growth and some aspects of physiology at acceptable level. DEI-CT images were acquired with 30 keV synchrotron X-rays. A series of DEI-CT slices were assembled together, to form a 3D data set. DEI-CT images explored more structural information and morphology. Noticed detailed anatomical, physiological observations, and contrast mechanisms. Furthermore, with these systems, some of the complex plant traits, root morphology, growth of laterals and subsequent laterals can be visualized directly.

36 MATERIALS SCIENCE↗

Chiral properties of the zero-field spiral state and field-induced magnetic phases of the itinerant kagome metal YMn 6 Sn 6

Applying a magnetic field in the hexagonal plane of YMn 6 Sn 6 leads to a complex magnetic phase diagram of commensurate and incommensurate phases, one of which coexists with the topological Hall effect (THE) generated by a unique fluctuation-driven mechanism. Using unpolarized neutron diffraction, we report on the solved magnetic structure for two previously identified, but unknown, commensurate phases. These include a low-temperature, high-field fanlike phase and a room-temperature, low-field canted antiferromagnetic phase. Here, an intermediate incommensurate phase between the fanlike and forced ferromagnetic phases is also identified as the last known phase of the in-plane field-temperature diagram. Additional characterization using synchrotron powder diffraction reveals extremely high-quality, single-phase crystals, which suggests that the presence of two incommensurate magnetic structures throughout much of the phase diagram is an intrinsic property of the system. Interestingly, polarized neutron diffraction shows that the centrosymmetric system hosts preferential chirality in the zero-field double-flat-spiral phase, which, along with the THE, is a topologically nontrivial characteristic.

36 MATERIALS SCIENCE↗

A Compact X-Ray System for Support of High Throughput Crystallography

Standard x-ray systems for crystallography rely on massive generators coupled with optics that guide X-ray beams onto the crystal sample. Optics for single-crystal diffractometry include total reflection mirrors, polycapillary optics or graded multilayer monochromators. The benefit of using polycapillary optic is that it can collect x-rays over tile greatest solid angle, and thus most efficiently, utilize the greatest portion of X-rays emitted from the Source, The x-ray generator has to have a small anode spot, and thus its size and power requirements can be substantially reduced We present the design and results from the first high flux x-ray system for crystallography that combine's a microfocus X-ray generator (40microns FWHM Spot size at a power of 45 W) and a collimating, polycapillary optic. Diffraction data collected from small test crystals with cell dimensions up to 160A (lysozyme and thaumatin) are of high quality. For example, diffraction data collected from a lysozyme crystal at RT yielded R=5.0% for data extending to 1.70A. We compare these results with measurements taken from standard crystallographic systems. Our current microfocus X-ray diffraction system is attractive for supporting crystal growth research in the standard crystallography laboratory as well as in remote, automated crystal growth laboratory. Its small volume, light-weight, and low power requirements are sufficient to have it installed in unique environments, i.e.. on-board International Space Station.

Ciszak, Ewa↗

Thermal Stability of a 4 Meter Primary Reflector for the Scanning Microwave Limb Sounder

We describe the fabrication and thermal-stability analysis and test of a composite demonstration model of the Scanning Microwave Limb Sounder (SMLS) primary reflector, having full 4m height and 1/3 the width planned for flight. SMLS is a space-borne heterodyne radiometer which will measure pressure, temperature and atmospheric constituents from thermal emission between 180 and 660 GHz. Current MLS instruments in low Earth orbit scan pencil-beam antennas (sized to resolve about one scale height) vertically over the atmospheric limb. SMLS, planned for the Global Atmospheric Composition Mission of the NRC Decadal Survey, adds azimuthal scanning for better horizontal and temporal resolution and coverage than typical orbit spacing provides. SMLS combines the wide scan range of the parabolic torus with unblocked offset Cassegrain optics. The resulting system is diffraction-limited in the vertical plane but highly astigmatic in the horizontal, having a beam aspect ratio [tilde operator]1:20. Symmetry about the nadir axis ensures that beam shape is nearly invariant over +/-65(white bullet) azimuth. The a feeds a low-noise SIS receiver whose FOV is swept over the reflector system by a small scanning mirror. Using finiteelement models of antenna reflectors and structure, we evaluate thermal deformations and the resulting optical performance for 4 orbital environments and isothermal soak. We compare deformations with photogrammetric measurements made during wide-range (ambient+[-97,+75](white bullet) C) thermal soak tests of the primary in a chamber. This range exceeds predicted orbital soak ranges by large factors, implying in-orbit thermal stability of 0.21(mu)m rms/(white bullet)C, which meets SMLS requirements.

Thermal stability tests↗

Dynamics of McMillan mappings II. axially symmetric map

Here, in this article, we investigate the transverse dynamics of a single particle in a model integrable accelerator lattice, based on a McMillan axially-symmetric electron lens. Although the McMillan e-lens has been considered as a device potentially capable of mitigating collective space charge forces, some of its fundamental properties have not been described yet. The main goal of our work is to close this gap and understand the limitations and potentials of this device. It is worth mentioning that the McMillan axially symmetric map provides the first-order approximations of dynamics for a general linear lattice plus an arbitrary thin lens with motion separable in polar coordinates. Therefore, advancements in its understanding should give us a better picture of more generic and not necessarily integrable round beams. In the first part of the article, we classify all possible regimes with stable trajectories and find the canonical action-angle variables. This provides an evaluation of the dynamical aperture, Poincaré rotation numbers as functions of amplitudes, and thus determines the spread in nonlinear tunes. Also, we provide a parameterization of invariant curves, allowing for the immediate determination of the map image forward and backward in time. The second part investigates the particle dynamics as a function of system parameters. We show that there are three fundamentally different configurations of the accelerator optics causing different regimes of nonlinear oscillations. Each regime is considered in great detail, including the limiting cases of large and small amplitudes. In addition, we analyze the dynamics in Cartesian coordinates and provide a description of observable variables and corresponding spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using the ISS as a Testbed to Prepare for the Next Generation of Space-Based Telescopes

The ISS provides a unique opportunity to develop the technologies and operational capabilities necessary to assemble future large space telescopes that may be used to investigate planetary systems around neighboring stars. Assembling telescopes in space is a paradigm-shifting approach to space astronomy. Using the ISS as a testbed will reduce the technical risks of implementing this major scientific facility, such as laser metrology and wavefront sensing and control (WFSC). The Optical Testbed and Integration on ISS eXperiment (OpTIIX) will demonstrate the robotic assembly of major components, including the primary and secondary mirrors, to mechanical tolerances using existing ISS infrastructure, and the alignment of the optical elements to a diffraction-limited optical system in space. Assembling the optical system and removing and replacing components via existing ISS capabilities, such as the Special Purpose Dexterous Manipulator (SPDM) or the ISS flight crew, allows for future experimentation and repair, if necessary. First flight on ISS for OpTIIX, a small 1.5 meter optical telescope, is planned for 2015. In addition to demonstration of key risk-retiring technologies, the OpTIIX program includes a public outreach program to show the broad value of ISS utilization.

Ess, Kim↗

Space Technology for Directly Imaging and Characterizing Exo-Earths

The detection of Earth-like exoplanets in the habitable zone of their stars, and their spectroscopic characteri- zation in a search for biosignatures, requires starlight suppression that exceeds the current best ground-based performance by orders of magnitude. The required planet/star brightness ratio of order 10-10 at visible wave-lengths can be obtained by blocking stellar photons with an occulter, either externally (a starshade) or internally (a coronagraph) to the telescope system, and managing diffracted starlight, so as to directly image the exoplanet in reflected starlight. Coronagraph instruments require advancement in telescope aperture (either monolithic or segmented), aperture obscurations (obscured by secondary mirror and its support struts), and wavefront error sensitivity (e.g. line-of-sight jitter, telescope vibration, polarization). The starshade, which has never been used in a science application, benefits a mission by being decoupled from the telescope, allowing a loosening of telescope stability requirements. In doing so, it transfers the difficult technology from the telescope system to a large deployable structure (tens of meters to greater than 100 m in diameter) that must be positioned precisely at a distance of tens of thousands of kilometers from the telescope. We describe in this paper a roadmap to achieving the technological capability to search for biosignatures on an Earth-like exoplanet from a future space telescope. Two of these studies, HabEx and LUVOIR, include the direct imaging of Earth-sized habitable exoplanets as a central science theme.

Crill, Brendan P.↗

Enhanced Video-Oculography System

A previously developed video-oculography system has been enhanced for use in measuring vestibulo-ocular reflexes of a human subject in a centrifuge, motor vehicle, or other setting. The system as previously developed included a lightweight digital video camera mounted on goggles. The left eye was illuminated by an infrared light-emitting diode via a dichroic mirror, and the camera captured images of the left eye in infrared light. To extract eye-movement data, the digitized video images were processed by software running in a laptop computer. Eye movements were calibrated by having the subject view a target pattern, fixed with respect to the subject s head, generated by a goggle-mounted laser with a diffraction grating. The system as enhanced includes a second camera for imaging the scene from the subject s perspective, and two inertial measurement units (IMUs) for measuring linear accelerations and rates of rotation for computing head movements. One IMU is mounted on the goggles, the other on the centrifuge or vehicle frame. All eye-movement and head-motion data are time-stamped. In addition, the subject s point of regard is superimposed on each scene image to enable analysis of patterns of gaze in real time.

Moore, Steven T.↗

Systems and methods for interferometric multifocus microscopy

A system to generate image representations includes a first objective that receives a first light beam emitted from a sample and a second objective that receives a second light beam emitted from the sample, where the first light beam and the second light beam have conjugate phase. The system also includes a first diffractive element to receive the first light beam and separate it into a first plurality of diffractive light beams that are spatially distinct, and a second diffractive element to receive the second light beam and separate it into a second plurality of diffractive light beams that are spatially distinct. The system further includes a detector that receives the first and second plurality of diffractive light beams. The first plurality of diffractive light beams and the second plurality of diffractive light beams are simultaneously directed and focused onto different portions of an image plane of the detector.

He, Kuan↗

Study report on laser storage and retrieval of image data

The theoretical foundation is presented for a system of real-time nonphotographic and nonmagnetic digital laser storage and retrieval of image data. The system utilizes diffraction-limited laser focusing upon thin metal films, melting elementary holes in the metal films in laser focus. The metal films are encapsulated in rotating flexible mylar discs which act as the permanent storage carries. Equal sized holes encompass two dimensional digital ensembles of information bits which are time-sequentially (bit by bit) stored and retrieved. The bits possess the smallest possible size, defined by the Rayleigh criterion of coherent physical optics. Space and time invariant reflective read-out of laser discs with a small laser, provides access to the stored digital information. By eliminating photographic and magnetic data processing, which characterize the previous state of the art, photographic grain, diffusion, and gamma-distortion do not exist. Similarly, magnetic domain structures, magnetic gaps, and magnetic read-out are absent with a digital laser disc system.

Becker, C. H.↗

Separation of Kondo lattice coherence from crystal electric field in CeIn 3 with Nd substitutions

The Ce m M n In 3m+2n (m=1,2;n=0,1) family has been one of the most studied families of heavy fermion compounds. This family has revealed many interesting low-temperature physics phenomena, like quantum critical points, heavy fermion superconductivity, and non-Fermi liquid behavior, when these materials are exposed to pressure, magnetic fields, and/or chemical substitution. In this work, we provide a thorough investigation of the Ce 1-x Nd x In 3 phase diagram through single crystal synthesis, x-ray diffraction, energy-dispersive spectroscopy, magnetic susceptibility, and electrical resistivity measurements. Previous electrical resistivity measurements on CeIn 3 reveal a broad maximum, T max ~50 K, which has been associated with the Kondo lattice coherence crossover and/or the crystal electric field depopulation effect as the 4f electrons condense from the high-energy quartet down to the ground state doublet. Our findings show that in the most disordered substitution region, x=0.4–0.5, these features disjoin to reveal two distinct broad humps in electrical resistivity measurements. Magnetic susceptibility and electrical resistivity data on Ce 1-x Nd x In 3 also reveal the antiferromagnetic ordering competition between CeIn 3 and NdIn 3 , where the T N of CeIn 3 is linearly suppressed to a critical concentration of x Nd ~0.6. This concentration is slightly lower than what was previously reported in nonmagnetically substituted Ce 1-x La x In 3 . Our magnetic susceptibility measurements and subsequent simulations show that in the CeIn 3 antiferromagnetic regime, x Nd ≤0.4, the Nd ions act as free paramagnets. The large magnitude of the associated paramagnetic response then masks the overlapping antiferromagnetic ordering signature of the Ce ions. Overall our study further sheds light on the underlying crystal electric field and Kondo lattice coherence interactions within the Ce m M n In 3m+2n family and could stimulate further studies of these systems via neutron diffraction or under applied pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136Xe

Abstract The imaging of individual Ba 2+ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba 2+ ion imaging inside a high-pressure xenon gas environment. Ba 2+ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm 2 located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in 136 Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale strain wave generation by a piezoelectric grating from polar vortices

Nanostructures formed by spontaneously broken symmetry have provided new ways to manipulate quantum states. Specifically, topological structures with periodic spatial ordering, such as polar vortices and skyrmions, can be ideal hosts for creating engineered responses in both spatial and frequency domains. So far, however, only a few examples of such hierarchical engineering have been reported in the literature. Here we demonstrate that the spatially modulated piezoelectric response of a polar vortex structure can create strain waves with a characteristic nanoscale wavefront. Using time-resolved pump–probe resonant X-ray scattering and diffraction measurements, coupled with dynamical phase-field simulations, we show that the piezoelectric modulation of the spontaneously formed polar vortex crystal functions as an acoustic diffraction grating. This system converts incoming laterally uniform strain waves into outgoing waves with a characteristic sub-terahertz frequency, driven by an intrinsic excitation of the polar vortex crystal. Moreover, our phase-field simulations suggest that the dynamic mechanical displacements exhibiting vortex textures are generated from both space- and time-varying piezoelectric responses. Our findings illustrate a new method for generating nanoscale strain waves with unique spatial textures by tuning the hierarchical order of polar topologies to engineer new collective modes, allowing for a wide range of control through the topological lattice.

ferroelectrics↗

A survey of laser display

Laser display systems, discussing mechanical, diffractive and refractive beam deflection techniques, electro-optical polarization devices, holographic displays, etc

Devaney, A. J.↗

A study to analyze six band multispectral images and fabricate a Fourier transform detector

An automatic Fourier transform diffraction pattern sampling system, used to investigate techniques for forestry classification of six band multispectral aerial photography is presented. Photographs and diagrams of the design, development and fabrication of a hybrid optical-digital Fourier transform detector are shown. The detector was designed around a concentric ring fiber optic array. This array was formed from many optical fibers which were sorted into concentric rings about a single fiber. All the fibers in each ring were collected into a bundle and terminated into a single photodetector. An optical/digital interface unit consisting of a high level multiplexer, and an analog-to-digital amplifier was also constructed and is described.

Shackelford, R. G.↗

Design of infrared astronomical satellite /IRAS/ primary mirror mounts

The design of an operational mount to rigidly secure the primary mirror to its baseplate without the introduction of figure error always proves to be a major task on diffraction limited optical systems. A summary of the design of the Infrared Astronomical Satellite (IRAS) primary mirror mount is given. The mirror was designed to be alligned and tested at room temperature and operated in a zero 'g' field at temperatures of 2K. To minimize overstressing, a stiffness requirement of greater than 150 Hz was required for cold launch and room temperature vibration acceptance testing. Additional isolation was required to minimize strains, introduced via the mounting base, due to thermal and mechanical distortions.

Schreibman, M.↗