Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of sub-micrometre-sized voids in fixed human brain tissue using scanning X-ray microdiffraction

Using a 5 µm-diameter X-ray beam, we collected scanning X-ray microdiffraction in both the small-angle (SAXS) and the wide-angle (WAXS) regimes from thin sections of fixed human brain tissue from Alzheimer's subjects. The intensity of scattering in the SAXS regime of these patterns exhibits essentially no correlation with the observed intensity in the WAXS regime, indicating that the structures responsible for these two portions of the diffraction patterns, which reflect different length scales, are distinct. SAXS scattering exhibits a power-law behavior in which the log of intensity decreases linearly with the log of the scattering angle. The slope of the log–log curve is roughly proportional to the intensity in the SAXS regime and, surprisingly, inversely proportional to the intensity in the WAXS regime. We interpret these observations as being due to the presence of sub-micrometre-sized voids formed during dehydration of the fixed tissue. The SAXS intensity is due largely to scattering from these voids, while the WAXS intensity derives from the secondary structures of macromolecular material surrounding the voids. The ability to detect and map the presence of voids within thin sections of fixed tissue has the potential to provide novel information on the degradation of human brain tissue in neurodegenerative diseases.

Chemistry↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A reference-area-free strain mapping method using precession electron diffraction data

Here, in this work, we developed a method using precession electron diffraction data to map the residual elastic strain at the nano-scale. The diffraction pattern of each pixel was first collected and denoised. Template matching was then applied using the center spot as the mask to identify the positions of the diffraction disks. Statistics of distances between the selected diffracted disks enable the user to make an informed decision on the reference and to generate strain maps. Strain mapping on an unstrained single crystal sapphire shows the standard deviation of strain measurement is 0.5%. With this method, we were able to successfully measure and map the residual elastic strain in VO 2 on sapphire and martensite in a Ni 50.3 Ti 29.7 Hf 20 shape memory alloy. This approach does not require the user to select a “strain-free area” as a reference and can work on datasets even with the crystals oriented away from zone axes. This method is expected to provide a robust and more accessible alternative means of studying the residual strain of various material systems that complements the existing algorithms for strain mapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higher Dimensionality in the Mg–Co–B System: Synthesis and Structure of Incommensurate Composite Mg 1+ε Co 4 B 4

Guided by high-temperature in situ X-ray diffraction, the discovery and synthesis of Mg 1+ε Co 4 B 4 (ε ≈ 0.272) using a MgH 2 hydride precursor is reported, along with a detailed crystal structure description and measurement of magnetic properties. The mismatch in lattice periodicities between Mg and Co–B substructures places Mg 1+ε Co 4 B 4 in the family of incommensurate composite crystals and prompted structural refinement in a (3 + 1)-dimensional model. The structure of Mg 1+ε Co 4 B 4 (P4 2 /ncm(00γ)s00s, a = 6.75847(7) Å, c = 3.94007(8) Å, q = (0, 0, 1.2721(3))) was refined from neutron powder diffraction and high-resolution powder X-ray diffraction data and confirmed by scanning transmission electron microscopy and electron diffraction. Mg 1+ε Co 4 B 4 is isostructural to Nd 1+ε Fe 4 B 4 and several related ternary borides with 0.07 ≤ ε ≤ 0.17, with Mg occupying the rare-earth site. Satellite reflections in the electron diffraction patterns hinted at positional modulation of the transition metal–boron substructure by Mg atoms, but this could not be refined from the neutron or X-ray diffraction data. Low-temperature magnetic measurements show no indications of long-range magnetic ordering or superconductivity down to 5 K. DFT calculations confirmed the absence of a magnetically ordered ground state and the stability of a 5:4 supercell (ε = 0.25) relative to the fully commensurate structure. Neutron diffraction and synthesis from elemental Mg demonstrated that Mg 1+ε Co 4 B 4 is not a hydrogen-stabilized phase. Mg 1+ε Co 4 B 4 represents the second compound reported in the Mg–Co–B system and the first superspace symmetry model of a Nd 1+ε Fe 4 B 4 -type incommensurate composite compound refined from powder diffraction data.

chemical structure↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

In situ Synchrotron X‐ray Metrology Boosted by Automated Data Analysis for Real‐time Monitoring of Cathode Calcination

Abstract Synchrotron X‐ray‐based in situ metrology is advantageous for monitoring the synthesis of battery materials, offering high throughput, high spatial and temporal resolution, and chemical sensitivity. However, the rapid generation of massive data poses a challenge to on‐site, on‐the‐fly analysis needed for real‐time process monitoring. Here, a weighted lagged cross‐correlation (WLCC) similarity approach is presented for automated data analysis, which merges with in situ synchrotron X‐ray diffraction metrology to monitor the calcination process of the archetypal nickel‐based cathode, LiNiO 2 . The WLCC approach, incorporating variables that account for peak shifts and width changes associated with structural transformations, enables rapid extraction of phase progression within 10 seconds from tens of diffraction patterns. Details are captured, from initial precursors to intermediates and the final layered LiNiO 2 , providing information for agile on‐site adjustments during experiments and complementing post hoc diffraction analysis by offering insights into early‐stage phase nucleation and growth. Expanding this data‐powered platform paves the way for real time calcination process monitoring and control, which is pivotal to quality control in battery cathode manufacturing.

36 MATERIALS SCIENCE↗

Large Angle Rocking Beam Electron Diffraction Utilizing Electron Direct Detector

Electron diffraction of a crystal is fundamentally a function of the potential of that crystal. The intensity of electron diffraction patterns is, as a result, sensitive to the charge density of atoms and bonding inside crystals. Experimentally, the traditional method to probe this information is quantitative Convergent Beam Electron Diffraction (CBED). Quantitative CBED or QCEBD is a method which uses dynamic diffraction theory to quantify CBED intensities and to extract information about crystal structure and bonding. The sensitivity of dynamical scattering is leveraged to measure crystal symmetry and crystal structure factors. At its limit, electron structure factors are measured at high accuracy allowing access to chemical bonding information, which corroborate theoretical calculations through multipole model refinements of the experimental charge density. The primary limit to QCBED is the requirement of a non-overlapping convergent beam. This subsequently limits QCBED to crystals with small unit cells which are stable under the focused probe.

Busch, Robert↗

Computational approaches to model X-ray photon correlation spectroscopy from molecular dynamics

X-ray photon correlation spectroscopy (XPCS) allows for the resolution of dynamic processes within a material across a wide range of length and time scales. X-ray speckle visibility spectroscopy (XSVS) is a related method that uses a single diffraction pattern to probe ultrafast dynamics. Interpretation of the XPCS and XSVS data in terms of underlying physical processes is necessary to establish the connection between the macroscopic responses and the microstructural dynamics. To aid the interpretation of the XPCS and XSVS data, we present a computational framework to model these experiments by computing the X-ray scattering intensity directly from the atomic positions obtained from molecular dynamics simulations. We compare the efficiency and accuracy of two alternative computational methods: the direct method computing the intensity at each diffraction vector separately, and a method based on fast Fourier transform that computes the intensities at all diffraction vectors at once. Furthermore, the computed X-ray speckle patterns capture the density fluctuations over a range of length and time scales and are shown to reproduce the known properties and relations of experimental XPCS and XSVS for liquids.

36 MATERIALS SCIENCE↗

Speckle contrast of interfering fluorescence X-rays

With the development of X-ray free-electron lasers (XFELs), producing pulses of femtosecond durations comparable with the coherence times of X-ray fluorescence, it has become possible to observe intensity–intensity correlations due to the interference of emission from independent atoms. This has been used to compare durations of X-ray pulses and to measure the size of a focused X-ray beam, for example. Here it is shown that it is also possible to observe the interference of fluorescence photons through the measurement of the speckle contrast of angle-resolved fluorescence patterns. Speckle contrast is often used as a measure of the degree of coherence of the incident beam or the fluctuations of the illuminated sample as determined from X-ray diffraction patterns formed by elastic scattering, rather than from fluorescence patterns as addressed here. Commonly used approaches to estimate speckle contrast were found to suffer when applied to XFEL-generated fluorescence patterns due to low photon counts and a significant variation of the excitation pulse energy from shot to shot. A new method to reliably estimate speckle contrast under such conditions, using a weighting scheme, is introduced. The method is demonstrated by comparing the speckle contrast of fluorescence observed with pulses of 3 fs to 15 fs duration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Non-thermal structural transformation of diamond driven by x-rays

Intense x-ray pulses can cause the non-thermal structural transformation of diamond. At the SACLA XFEL facility, pump x-ray pulses triggered this phase transition, and probe x-ray pulses produced diffraction patterns. Time delays were observed from 0 to 250 fs, and the x-ray dose varied from 0.9 to 8.0 eV/atom. The intensity of the (111), (220), and (311) diffraction peaks decreased with time, indicating a disordering of the crystal lattice. From a Debye–Waller analysis, the rms atomic displacements perpendicular to the (111) planes were observed to be significantly larger than those perpendicular to the (220) or (311) planes. At a long time delay of 33 ms, graphite (002) diffraction indicates that graphitization did occur above a threshold dose of 1.2 eV/atom. These experimental results are in qualitative agreement with XTANT+ simulations using a hybrid model based on density-functional tight-binding molecular dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extending the Takagi-Taupin equations for x-ray nanobeam Bragg coherent diffraction

We present an approach for simulating x-ray nanobeam Bragg coherent diffraction patterns based on the Takagi-Taupin equations. Compared to conventional methods, the current approach can be universally applied to any weakly strained system including semi-infinite crystals that diffract dynamically. It addresses issues such as the curved wave front and redivergence of the focused incident beam. In conclusion, we show excellent agreement with experimental data for a strained La 0.7 ⁢Sr 0.3⁢ MnO 3 thin film on a SrTiO 3 substrate and a path to extracting physical information using automatic differentiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-modal characterization of the B2 phase in the Ta-Re binary system

The energy and transportation industries demand materials that retain their mechanical property at high temperatures. Refractory complex concentrated alloys (RCCAs) with a BCC + B2 microstructure offer a potential solution, where maintaining the high temperature mechanical properties can be achieved by precipitation strengthening. This depends on the B2 phase in RCCAs being thermodynamically stable with a high solvus temperature. Recently, we predicted the high temperature stability of the B2 structure in the Ta-Re binary system, using density functional theory. Here, in this study, we provide experimental evidence for the existence of this phase for the first time, using a Ta 65 Re 35 alloy. Despite Ta-Re binary phase diagrams predicting a single-phase BCC microstructure for Ta 65 Re 35 , we show that a high Z nanoscale secondary phase appears after heat treatment at 1550 °C and 1100 °C. Scanning transmission electron microscopy (STEM) revealed that this phase has a cubic structure and is equiatomic TaRe though B2 superlattice reflections were absent in fast Fourier transforms (FFT) and diffraction patterns (DPs). DP simulations indicate that the B2 TaRe superlattice reflections are up to two orders of magnitude weaker than their fundamental reflections, making their detection challenging via electron microscopy. Neutron diffraction confirmed the second phase had a B2 structure. This study identified a previously unobserved high temperature stable B2 phase in the Ta-Re system, enabling the development of new high temperature BCC + B2 RCCAs.

36 MATERIALS SCIENCE↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Fidelity-preserving enhancement of ptychography with foundational text-to-image models

Ptychographic phase retrieval enables high-resolution imaging of complex samples but often suffers from artifacts such as grid pathology and multislice crosstalk, which degrade reconstructed images. We propose a plug-and-play (PnP) framework that integrates physics model-based phase retrieval with text-guided image editing using foundational diffusion models. By employing the alternating direction method of multipliers, our approach ensures consensus between data fidelity and artifact removal subproblems, maintaining physical consistency while enhancing image quality. Artifact removal is achieved using a text-guided diffusion image editing method (LEDITS++) with a pre-trained foundational diffusion model, allowing users to specify artifacts for removal in natural language. Demonstrations on simulated and experimental datasets show significant improvements in artifact suppression and structural fidelity, validated by metrics such as peak signal-to-noise ratio and diffraction pattern consistency. This work highlights the combination of text-guided generative models and model-based phase retrieval algorithms as a transferable and fidelity-preserving method for high-quality diffraction imaging.

image editing↗

Exact and fast calculation of the X-ray pair distribution function

A fast and exact algorithm to calculate the powder pair distribution function (PDF) for the case of periodic structures is presented. The new algorithm calculates the PDF by a detour via reciprocal space. The calculated normalized total powder diffraction pattern is transferred into the PDF via the sine Fourier transform. The calculation of the PDF via the powder pattern avoids the conventional simplification of X-ray and electron atomic form factors. It is thus exact for these types of radiation, as is the conventional calculation for the case of neutron diffraction. The new algorithm further improves the calculation speed. Additional advantages are the improved detection of errors in the primary data, the handling of preferred orientation, the ease of treatment of magnetic scattering and a large improvement to accommodate more complex instrumental resolution functions.

36 MATERIALS SCIENCE↗

Search for octupolar order in NpO 2 by neutron powder diffraction

The magnetic structure of neptunium dioxide (NpO 2 ) remains a mystery despite decades of research. We revisited the search for magnetic ordering in NpO 2 by performing a powder neutron diffraction experiment at low temperatures and relatively large values of Q. Diffraction data were collected for 300 MK, 15 K, and 35 K to understand the phase transition near 25 K. However, no significant changes in the neutron diffraction pattern were identified. Using the octupolar magnetic form factor j 6 , the maximum theoretical expected value of the magnetic moment (3.27 μ B ), the calculated magnetic Bragg peak intensities would not be observable in neutron powder diffraction data. This value is much larger than the previously estimated magnetic moment of ~0.1 μ B . In conclusion, supported by experimental results, these calculations suggest that unpolarized neutron powder diffraction is unsuitable for measuring octupolar ordering in NpO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for mapping submicron-scale crystallographic order/disorder applied to human tooth enamel

Tooth enamel, the outermost layer of human teeth, is a complex, hierarchically structured biocomposite. The details of this structure are important in multiple human health contexts, from understanding the progression of dental caries (tooth decay) to understanding the process of amelogenesis and related developmental defects. Enamel is composed primarily of long, nanoscale crystallites of hydroxyapatite that are bundled by the thousands to form micron-scale rods. Studies with transmission electron microscopy show the relationships between small groups of crystallites and X-ray diffraction characterize averages over many rods, but the direct measurement of variations in local crystallographic structure across and between enamel rods has been missing. Here, we describe a synchrotron X-ray-based experimental approach and a novel analysis method developed to address this gap in knowledge. A ~500-nm-wide beam of monochromatic X-rays in conjunction with a sample section only 1 μm in thickness enables 2D diffraction patterns to be collected from small well-separated volumes within the enamel microstructure but still probes enough crystallites (~300 per pattern) to extract population-level statistics on crystallographic features like lattice parameter, crystallite size, and orientation distributions. Furthermore, the development of a quantitative metric to characterize relative order and disorder based on the azimuthal autocorrelation of diffracted intensity enables these crystallographic measurements to be correlated with their location within the enamel microstructure (e.g., between rod and interrod regions). These methods represent a step forward in the characterization of human enamel and will elucidate the variation of the crystallographic structure across and between enamel rods for the first time.

crystallographic order/disorder↗