Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis of a dual-reflector antenna system using physical optics and digital computers

The application of physical-optics diffraction theory to a deployable dual-reflector geometry is discussed. The methods employed are not restricted to the Conical-Gregorian antenna, but apply in a general way to dual and even multiple reflector systems. Complex vector wave methods are used in the Fresnel and Fraunhofer regions of the reflectors. Field amplitude, phase, polarization data, and time average Poynting vectors are obtained via an IBM 360/91 digital computer. Focal region characteristics are plotted with the aid of a CalComp plotter. Comparison between the GSFC Huygens wavelet approach, JPL measurements, and JPL computer results based on the near field spherical wave expansion method are made wherever possible.

Schmidt, R. F.↗

Experiment K305: Quantitative analysis of selected bone parameters. Supplement 3A: Trabecular spacing and orientation in the long bones

Values of mean trabecular spacing computed from optical diffraction patterns of 1:1 X-ray micrographs of tibial metaphysis and those obtained by standard image digitization techniques show excellent agreement. Upper limits on values of mean trabecular orientation deduced from diffraction patterns and the images are also in excellent agreement. Values of the ratio of mean trabecular spatial density in a region of 300 micrometers distal to the downwardly directed convexity in the cartilage growth plate to the value adjacent to the plate determined for flight animals sacrificed at recovery were significantly smaller than values for vivarium control animals. No significant differences were found in proximal regions. No significant differences in mean trabecular orientation were detected. Decreased values of trabecular spatial density and of both obsteoblastic activity and trabecular cross-sectional area noted in collateral researches suggest decreased modeling activity under weightlessness.

Judy, M. M.↗

Coaxial carbon plasma gun deposition of amorphous carbon films

A unique plasma gun employing coaxial carbon electrodes was used in an attempt to deposit thin films of amorphous diamond-like carbon. A number of different structural, compositional, and electrical characterization techniques were used to characterize these films. These included scanning electron microscopy, scanning transmission electron microscopy, X ray diffraction and absorption, spectrographic analysis, energy dispersive spectroscopy, and selected area electron diffraction. Optical absorption and electrical resistivity measurements were also performed. The films were determined to be primarily amorphous, with poor adhesion to fused silica substrates. Many inclusions of particulates were found to be present as well. Analysis of these particulates revealed the presence of trace impurities, such as Fe and Cu, which were also found in the graphite electrode material. The electrodes were the source of these impurities. No evidence of diamond-like crystallite structure was found in any of the film samples. Details of the apparatus, experimental procedure, and film characteristics are presented.

Sater, D. M.↗

Interpolation Methods for GTD Analysis of Shaped Reflectors

The finding of smooth analytic representations for antenna reflector surfaces which are prescribed only by discretized data obtained by various synthesis methods is examined. Frequently the data are distributed in a nonuniform grid and contain noise. The smoothness required is to C sub 1 for physical optics diffraction analysis and to C sub 2 for geometrical theory of diffraction (GTD) analysis. The GTD analysis approach requires a surface description which returns data very rapidly. Two methods of interpolation, the global and the local methods, are discussed. They each have advantages and disadvantages; characteristics are discussed and examples are presented.

Galindo-Israel, V.↗

Compact acoustic levitation device for studies in fluid dynamics and material science in the laboratory and microgravity

An ultrasonic levitation device operable in both ordinary ground-based as well as in potential space-borne laboratories is described together with its various applications in the fields of fluid dynamics, material science, and light scattering. Some of the phenomena which can be studied by this instrument include surface waves on freely suspended liquids, the variations of the surface tension with temperature and contamination, the deep undercooling of materials with the temperature variations of their density and viscosity, and finally some of the optical diffraction properties of transparent substances.

Trinh, E. H.↗

Solidification of Nb-Ge alloys in long drop tubes

The 30-m and 100 m-long drop tubes at the Marshall Space Flight Center have been used to obtain large undercooling in Nb-Ge alloys. Electron beam melting has been used to obtain drops approximately 2.5 mm in diam. In the 30-m tube, many specimens fell the length of the tube without solidifying, and were ultimately liquid-quenched in oil. The amount of undercooling prior to the quench was usually around 0.13 T(m). In the 100-m tube, freezing generally initiated during free fall, and the maximum undercooling was around 0.22 T(m). Microstructures were characterized by a combination of X-ray diffraction, optical microscopy, and scanning electron microscopy with energy dispersive analysis by X-rays. A variety of interesting microstructures was observed.

Bayuzick, R. J.↗

Design analysis of the astrometrical telescope facility

This paper presents a detailed analysis of a space-based telescope requiring an accuracy of 50 pico radians. A relationship between the geometric centroid of a diffraction image and wave aberrations is derived by a combination approach of diffraction optics and geometric optics. Based on sensitivity of the centroid, one-mirror and two-mirror aplanatic telescopes are investigated. The comparison among three telescopes, parabola, Schwartzschild and Ritchey-Chretien are quantitatively carried out in terms of their sensitivities to the systematic errors and random errors. The study shows that the Ritchey-Chretien design is the most preferable.

Huang, Chunsheng↗

On the theory of the synthesis of offset dual-shaped reflectors - Case examples

In an earlier paper by Galindo-Israel et al. (1987), the geometrical optics (GO) principles, constraints, and requirements of the dual- and single-offset-shaped reflector synthesis problem were collected and developed into a set of nonlinear first-order PDEs. An extension of the methods by which solutions to the PDEs can be obtained is presented, together with several case examples. These examples are independently analyzed by GO and physical optics diffraction methods. The starting point for the integration over each reflector can be taken on the outer rim, at the center, or at an intermediate point-the intermediate starting point being the more general case. The utility of the speed of this synthesis method is demonstrated. For example, the program utilized completes a synthesis in less than 45 s on a 386/20 personal computer and within a fraction of a second on a mainframe Cray. This makes practical the incorporation of the synthesis into a search algorithm that can optimize one or more parameters of the reflector system. As an example, the optimization of the mapping equations for low cross polarization is discussed.

Galindo-Israel, Victor↗

Surface migration and volume diffusion in the AgGaSe2-Ag2Se system

Surface migration and volume diffusion in the Ag2Se-AgGaSe2 system were investigated using reactive diffusion couples which were analyzed by X-ray diffraction, optical microscopy, and electron probe microanalysis. The surface diffusivities of all mobile species are found to be much larger than volume diffusivities. The results of the study suggest that Se moves together with Ag and Ga to maintain binary (Ag2Se and Ga2Se3) stoichiometry and electroneutrality. The dominance of surface migration kinetics can account for the uniform annihilation of second-phase precipitates during heat treatments.

Kim, N.-H.↗

Cardiac morphology after conditions of microgravity during Cosmos 2044

Light- and electron-microscopic studies were performed on cardiac muscle from rats flown on Cosmos 2044 and from four control groups. Average cross-sectional area of myofibers was measured by video analysis of the light-microscopic images of papillary and ventricular muscle samples from all animals. This cross-sectional area was significantly decreased in flight rats (P = 0.03) compared with synchronous controls. Additional findings at the electron microscopic level consistent with this atrophy were obtained by stereological analysis and optical diffraction analysis of papillary muscle samples. Slightly higher mitochondrial volume density values and mitochondria-to-myofibril ratios as well as normal A-band spacings (d1,0) and Z-band spacings of myofibrils were observed in the tail-suspension and flight groups. General morphological features similar to those in ventricular samples from the previous Cosmos 1887 flight were observed.

Goldstein, Margaret A.↗

Mapping crystal defects with a digital scanning ultramicroscope

A computer controlled scanning ultramicroscope has been built to assist in the characterization of transparent crystals. The device measures the scattering of a focused He-Ne laser beam by crystalline defects. As an XYZ translation table moves the crystal under the ultramicroscope, the scattered light is measured by a photodetector whose output is digitized and recorded. From this data, contour maps or three dimensional perspective plots of the scattering regions of the crystal can be generated to assist in finding patterns of defects which might be correlated with perturbations in the growth process. The verified resolution of the present instrument is about 1 micrometer, which is limited by the minimum step of the stepper-motor driven translation stages, optical diffraction effects and the sensitivity of the detector at the laser light frequency. The instrument was used to build a database of defects patterns in commercial laboratory grown triglycine sulphate (TGS) crystals, and to map defects in a TGS crystal grown from aqueous solution during the flight of Spacelab 3. This crystal shows indications of a reduction both in the generation of defects at the seed-new growth interface and in their propagation into the new crystal.

Springer, J. M.↗

Advanced technology for a satellite multichannel demultiplexer/demodulator

Satellite on-board processing is needed to efficiently service multiple users while at the same time minimizing earth station complexity. The processing satellite receives a wideband uplink at 30 GHz and down-converts it to a suitable intermediate frequency. A multichannel demultiplexer then separates the composite signal into discrete channels. Each channel is then demodulated by bulk demodulators, with the baseband signals routed to the downlink processor for retransmission to the receiving earth stations. This type of processing circumvents many of the difficulties associated with traditional bent-pipe repeater satellites. Uplink signal distortion and interference are not retransmitted on the downlink. Downlink power can be allocated in accordance with user needs, independent of uplink transmissions. This allows the uplink users to employ different data rates as well as different modulation and coding schemes. In addition, all downlink users have a common frequency standard and symbol clock on the satellite, which is useful for network synchronization in time division multiple access schemes. The purpose of this program is to demonstrate the concept of an optically implemented multichannel demultiplexer (MCD). A proof-of-concept (POC) model has been developed which has the ability to receive a 40 MHz wide composite signal consisting of up to 1000 40 kHz QPSK modulated channels and perform the demultiplexing process. In addition a set of special test equipment (STE) has been configured to evaluate the performance of the POC model. The optical MCD is realized as an acousto-optic spectrum analyzer utilizing the capability of Bragg cells to perform the required channelization. These Bragg cells receive an optical input from a laser source and an RF input (the signal). The Bragg interaction causes optical output diffractions at angles proportional to the RF input frequency. These discrete diffractions are optically detected and output to individual demodulators for baseband conversion. Optimization of the MCD design was conducted in order to achieve a compromise between two opposing sources of signal degradation: adjacent channel interference and intersymbol interference. The system was also optimized to allow simple, inexpensive ground stations communications with the MCD. These design goals led to the realization of a POC MCD which demonstrates the demultiplexing function with minimal signal degradation. Performance evaluation results using the STE equipment indicate that the dynamic range of the demultiplexer in the presence of adjacent and multiple channel loading is 40 - 50 dB. Measured bit error rate (BER) probabilities varied from the predicted theoretical results by one dB or less. The performance of the proof-of-concept model indicate that the development of a space qualified optically implemented MCD are feasible. The advantages to such an implementation include reduced size, weight and power and increased reliability when compared with electronic approaches. All of these factors are critical to on-board satellite processors. Further optimization can be conducted which trade ground station complexity and MCD performance to achieve desired system results.

Abramovitz, Irwin J.↗

Growth of Carbon Nanostructure Materials Using Laser Vaporization

Since the potential applications of carbon nanotubes (CNT) was discovered in many fields, such as non-structure electronics, lightweight composite structure, and drug delivery, CNT has been grown by many techniques in which high yield single wall CNT has been produced by physical processes including arc vaporization and laser vaporization. In this presentation, the growth mechanism of the carbon nanostructure materials by laser vaporization is to be discussed. Carbon nanoparticles and nanotubes have been synthesized using pulsed laser vaporization on Si substrates in various temperatures and pressures. Two kinds of targets were used to grow the nanostructure materials. One was a pure graphite target and the other one contained Ni and Co catalysts. The growth temperatures were 600-1000 C and the pressures varied from several torr to 500 torr. Carbon nanoparticles were observed when a graphite target was used, although catalysts were deposited on substrates before growing carbon films. When the target contains catalysts, carbon nanotubes (CNT) are obtained. The CNT were characterized by scanning electron microscopy, x-ray diffraction, optical absorption and transmission, and Raman spectroscopy. The temperature-and pressure-dependencies of carbon nanotubes' growth rate and size were investigated.

Zhu, Shen↗

A Compact X-Ray System for Support of High Throughput Crystallography

Standard x-ray systems for crystallography rely on massive generators coupled with optics that guide X-ray beams onto the crystal sample. Optics for single-crystal diffractometry include total reflection mirrors, polycapillary optics or graded multilayer monochromators. The benefit of using polycapillary optic is that it can collect x-rays over tile greatest solid angle, and thus most efficiently, utilize the greatest portion of X-rays emitted from the Source, The x-ray generator has to have a small anode spot, and thus its size and power requirements can be substantially reduced We present the design and results from the first high flux x-ray system for crystallography that combine's a microfocus X-ray generator (40microns FWHM Spot size at a power of 45 W) and a collimating, polycapillary optic. Diffraction data collected from small test crystals with cell dimensions up to 160A (lysozyme and thaumatin) are of high quality. For example, diffraction data collected from a lysozyme crystal at RT yielded R=5.0% for data extending to 1.70A. We compare these results with measurements taken from standard crystallographic systems. Our current microfocus X-ray diffraction system is attractive for supporting crystal growth research in the standard crystallography laboratory as well as in remote, automated crystal growth laboratory. Its small volume, light-weight, and low power requirements are sufficient to have it installed in unique environments, i.e.. on-board International Space Station.

Ciszak, Ewa↗

Membrane Vibration Analysis Above the Nyquist Limit with Fluorescence Videogrammetry

A new method for generating photogrammetric targets by projecting an array of laser beams onto a membrane doped with fluorescent laser dye has recently been developed. In this paper we review this new fluorescence based technique, then proceed to show how it can be used for dynamic measurements, and how a short pulsed (10 ns) laser allows the measurement of vibration modes at frequencies several times the sampling frequency. In addition, we present experimental results showing the determination of fundamental and harmonic vibration modes of a drum style dye-doped polymer membrane tautly mounted on a 12-inch circular hoop and excited with 30 Hz and 62 Hz sinusoidal acoustic waves. The projected laser dot pattern was generated by passing the beam from a pulsed Nd:YAG laser though a diffractive optical element, and the resulting fluorescence was imaged with three digital video cameras, all of which were synchronized with a pulse and delay generator. Although the video cameras are capable of 240 Hz frame rates, the laser s output was limited to 30 Hz and below. Consequently, aliasing techniques were used to allow the measurement of vibration modes up to 186 Hz with a Nyquist limit of less than 15 Hz.

Dorrington, Adrian A.↗

Finite Element Analysis of the LOLA Receiver Telescope Lens

This paper presents the finite element stress and distortion analysis completed on the Receiver Telescope lens of the Lunar Orbiter Laser Altimeter (LOLA). LOLA is one of six instruments on the Lunar Reconnaissance Orbiter (LRO), scheduled to launch in 2008. LOLA's main objective is to produce a high-resolution global lunar topographic model to aid in safe landings and enhance surface mobility in future exploration missions. The Receiver Telescope captures the laser pulses transmitted through a diffractive optical element (DOE) and reflected off the lunar surface. The largest lens of the Receiver Telescope, Lens 1, is a 150 mm diameter aspheric lens originally designed to be made of BK7 glass. The finite element model of the Receiver Telescope Lens 1 is comprised of solid elements and constrained in a manner consistent with the behavior of the mounting configuration of the Receiver Telescope tube. Twenty-one temperature load cases were mapped to the nodes based on thermal analysis completed by LOLA's lead thermal analyst, and loads were applied to simulate the preload applied from the ring flexure. The thermal environment of the baseline design (uncoated BK7 lens with no baffle) produces large radial and axial gradients in the lens. These large gradients create internal stresses that may lead to part failure, as well as significant bending that degrades optical performance. The high stresses and large distortions shown in the analysis precipitated a design change from BK7 glass to sapphire.

Matzinger, Elizabeth↗

Video sensor with range measurement capability

A video sensor device is provided which incorporates a rangefinder function. The device includes a single video camera and a fixed laser spaced a predetermined distance from the camera for, when activated, producing a laser beam. A diffractive optic element divides the beam so that multiple light spots are produced on a target object. A processor calculates the range to the object based on the known spacing and angles determined from the light spots on the video images produced by the camera.

Briscoe, Jeri M.↗

Wavefront Sensing of X-Ray Telescopes

Phase Retrieval analysis of off-axis or defocused focal-plane data from telescope optics has been proven effective in understanding misalignments and optical aberrations in normal incidence telescopes. The approach is used, e.g., in commissioning of the James Webb Space Telescope (JWST) segmented primary mirror. There is a similar need for evaluating low-order figure errors of grazing incidence mirrors and nested telescope assemblies. When implemented in these systems, phase retrieval does not depend on normal incidence access to each mirror (shell) surface and, therefore, provides an effective means for evaluating nested x-ray telescopes during integration and test. We have applied a well-known phase retrieval algorithm to grazing incidence telescopes. The algorithm uses the Levenberg-Marquardt optimization procedure to perform a non-linear least-squares fit of the telescope Point Spread Function (PSF). The algorithm can also retrieve low order figure errors at visible wavelengths where optical diffraction is the dominant defect in the PSF. In this paper we will present the analytical approach and its implementation for grazing incidence mirrors of the International X-Ray Observatory (IXO). We analyze the effects of low order axial surface errors individually, and in combination on the system PSF at 633 nanometers. We demonstrate via modeling that the wavefront sensing algorithm can recover axial errors (of the grazing incidence mirrors) to a small fraction of the known axial figure errors using simulated PSFs as input data to the algorithm.

Saha, Timo↗