Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diamond detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Artifact identification in X-ray diffraction data using machine learning methods

In situ synchrotron high-energy X-ray powder diffraction (XRD) is highly utilized by researchers to analyze the crystallographic structures of materials in functional devices ( e.g. battery materials) or in complex sample environments ( e.g. diamond anvil cells or syntheses reactors). An atomic structure of a material can be identified by its diffraction pattern along with a detailed analysis of the Rietveld refinement which yields rich information on the structure and the material, such as crystallite size, microstrain and defects. For in situ experiments, a series of XRD images is usually collected on the same sample under different conditions ( e.g. adiabatic conditions) yielding different states of matter, or is simply collected continuously as a function of time to track the change of a sample during a chemical or physical process. In situ experiments are usually performed with area detectors and collect images composed of diffraction patterns. For an ideal powder, the diffraction pattern should be a series of concentric Debye–Scherrer rings with evenly distributed intensities in each ring. For a realistic sample, one may observe different characteristics other than the typical ring pattern, such as textures or preferred orientations and single-crystal diffraction spots. Textures or preferred orientations usually have several parts of a ring that are more intense than the rest, whereas single-crystal diffraction spots are localized intense spots owing to diffraction of large crystals, typically >10 µm. In this work, an investigation of machine learning methods is presented for fast and reliable identification and separation of the single-crystal diffraction spots in XRD images. The exclusion of artifacts during an XRD image integration process allows a precise analysis of the powder diffraction rings of interest. When it is trained with small subsets of highly diverse datasets, the gradient boosting method can consistently produce high-accuracy results. The method dramatically decreases the amount of time spent identifying and separating single-crystal diffraction spots in comparison with the conventional method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS

We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.

Aitken, Branden [Victoria U.]↗

First Measurement of the Nuclear-Recoil Ionization Yield in Silicon at 100 eV

We measured the nuclear-recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4 keV down to 100 eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100 eV. In conclusion, these results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoelectric absorption cross section of silicon near the bandgap from room temperature to sub-Kelvin temperature

The use of cryogenic silicon as a detector medium for dark matter searches is gaining popularity. Many of these searches are highly dependent on the value of the photoelectric absorption cross section of silicon at low temperatures, particularly near the silicon bandgap energy, where the searches are most sensitive to low mass dark matter candidates. While such cross section data have been lacking from the literature, previous dark matter search experiments have attempted to estimate this parameter by extrapolating it from higher temperature data. However, discrepancies in the high temperature data have led to order-of-magnitude differences in the extrapolations. In this paper, we resolve these discrepancies by using a novel technique to make a direct, low temperature measurement of the photoelectric absorption cross section of silicon at energies near the bandgap (1.2 eV–2.8 eV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MATHUSLA: An External Long-Lived Particle Detector to Maximize the Discovery Potential of the HL-LHC

We present the current status of the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle (LLP) detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA40 is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate reach of the LHC main detectors. This provides unique sensitivity to many LLP signals that are highly theoretically motivated, due to their connection to the hierarchy problem, the nature of dark matter, and baryogenesis. Data taking is projected to commence with the start of HL-LHC operations. We summarize the new 40m design for the detector that was recently presented in the MATHUSLA Conceptual Design Report, alongside new realistic background and signal simulations that demonstrate high efficiency for the main target LLP signals in a background-free HL-LHC search. We argue that MATHUSLA's uniquely robust expansion of the HL-LHC physics reach is a crucial ingredient in CERN's mission to search for new physics and characterize the Higgs boson with precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Information theory optimization of signals from small-angle scattering measurements

Small-angle X-ray scattering (SAXS) of particles in solution informs on the conformational states and assemblies of biological macromolecules (bioSAXS) outside of cryo- and solid-state conditions. In bioSAXS, the SAXS measurement under dilute conditions is resolution limited, and through an inverse Fourier transform, the measured SAXS intensities directly relate to the physical space occupied by the particles via the P (r)-distribution. Yet, this inverse transform of SAXS data has been historically cast as an ill-posed, ill-conditioned problem requiring an indirect approach. Here, we show that through the applications of matrix and information theories, the inverse transform of SAXS intensity data is a well-conditioned problem. The so-called ill-conditioning of the inverse problem is directly related to the Shannon number. By exploiting the oversampling enabled by modern detectors, a direct inverse Fourier transform of the SAXS data is possible, provided the recovered information does not exceed the Shannon number. The Shannon limit corresponds to the maximum number of significant singular values that can be recovered in a SAXS experiment, suggesting this relationship is a fundamental property of band-limited inverse integral transform problems. This correspondence reduces the complexity of the inverse problem to the Shannon limit and maximum dimension. We propose a hybrid scoring function using an information theory framework that assesses both the quality of the model-data fit as well as the quality of the recovered P (r)-distribution. The hybrid score utilizes the Akaike information criteria and Durbin-Watson statistic that considers parameter-model complexity, i.e., degrees of freedom, and the randomness of the model-data residuals. The described tests and findings extend the boundaries for bioSAXS by completing the information theory formalism initiated by Peter B. Moore to enable a quantitative measure of resolution in SAXS, robustly determine maximum dimension, and more precisely define the best parameter model appropriately representing the observed scattering data.

Rambo, Robert P. [Science and Technology Facilitie↗

Searching for long-lived particles beyond the Standard Model at the Large Hadron Collider

Particles beyond the Standard Model (SM) can generically have lifetimes that are long compared to SM particles at the weak scale. When produced at experiments such as the Large Hadron Collider (LHC) at CERN, these long-lived particles (LLPs) can decay far from the interaction vertex of the primary proton–proton collision. Such LLP signatures are distinct from those of promptly decaying particles that are targeted by the majority of searches for new physics at the LHC, often requiring customized techniques to identify, for example, significantly displaced decay vertices, tracks with atypical properties, and short track segments. Given their non-standard nature, a comprehensive overview of LLP signatures at the LHC is beneficial to ensure that possible avenues of the discovery of new physics are not overlooked. Here we report on the joint work of a community of theorists and experimentalists with the ATLAS, CMS, and LHCb experiments—as well as those working on dedicated experiments such as MoEDAL, milliQan, MATHUSLA, CODEX-b, and FASER—to survey the current state of LLP searches at the LHC, and to chart a path for the development of LLP searches into the future, both in the upcoming Run 3 and at the high-luminosity LHC. The work is organized around the current and future potential capabilities of LHC experiments to generally discover new LLPs, and takes a signature-based approach to surveying classes of models that give rise to LLPs rather than emphasizing any particular theory motivation. We develop a set of simplified models; assess the coverage of current searches; document known, often unexpected backgrounds; explore the capabilities of proposed detector upgrades; provide recommendations for the presentation of search results; and look towards the newest frontiers, namely high-multiplicity 'dark showers', highlighting opportunities for expanding the LHC reach for these signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗