Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SOFIA Science Instruments: Commissioning, Upgrades and Future Opportunities

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is the world's largest airborne observatory, featuring a 2.5 meter telescope housed in the aft section of a Boeing 747sp aircraft. SOFIA's current instrument suite includes: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), a 5-40 μm dual band imager/grism spectrometer developed at Cornell University; HIPO (High-speed Imaging Photometer for Occultations), a 0.3-1.1 micron imager built by Lowell Observatory; FLITECAM (First Light Infrared Test Experiment CAMera), a 1-5 micron wide-field imager/grism spectrometer developed at UCLA; FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), a 42-210 micron IFU grating spectrograph completed by University Stuttgart; and EXES (Echelon-Cross- Echelle Spectrograph), a 5-28 micron high-resolution spectrometer being completed by UC Davis and NASA Ames. A second generation instrument, HAWC+ (Highresolution Airborne Wideband Camera), is a 50-240 micron imager being upgraded at JPL to add polarimetry and new detectors developed at GSFC. SOFIA will continually update its instrument suite with new instrumentation, technology demonstration experiments and upgrades to the existing instrument suite. This paper details instrument capabilities and status as well as plans for future instrumentation, including the call for proposals for 3rd generation SOFIA science instruments.

FLITECAM↗

MKID Structures for Sub-millimeter Astronomy

Of the high performance detector technologies currently being developed, Microwave Kinetic Inductance Detectors (MKIDs) have the greatest promise for scaling to very large arrays (approx.10(exp 5) detectors). Such arrays can provide high quantum efficiency, and can be designed to provide background limited performance over a wide range of incident powers, making them candidates for a wide range of instruments, ranging from suborbital imagers to spaceborne spectrometers. We are extending Microwave Kinetic Inductance Detectors (MKIDs) technology to the 40 - 400 microns spectral regions via a novel detector concept. In this approach thin film superconducting microstrip lines are used to simultaneously absorb and readout the incident signal with high inter-pixel isolation. Progress on these fabrication and test efforts will be presented.

Wollack, Edward↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Latest Progress on the Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

We present the latest progress on building the balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument, including testing and calibration of the detectors and development of the imaging and aspect systems. A continental-US test flight is slated for fall 2012. GRIPS will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approx.20. keV to > approx.10 MeV. The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution to within <0.1 cu mm. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-cm thick tungsten-alloy grid with pitches that range quasi-continuously from 1 to 13 mm. With the MPRM situated 8 meters from the spectrometer, this instrument will provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate the 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e. as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS will address questions relevant to particle acceleration and energy release that ha-.e been raised by recent solar flare observations, such as: What causes the spatial separation between energetic electron producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the accelerated electrons, and why do relativistic electron dominate in the corona? How does the composition of accelerated and ambient material vary with space and time, and why?

Shih, Albert Y.↗

FPGA-accelerated SpeckleNN with SNL for real-time X-ray single-particle imaging

We present the implementation of a specialized version of our previously published unified embedding model, SpeckleNN, for real-time speckle pattern classification in X-ray Single-Particle Imaging (SPI), using the SLAC Neural Network Library (SNL) on an FPGA platform. This hardware realization transitions SpeckleNN from a prototypic model into a practical edge solution, optimized for running inference near the detector in high-throughput X-ray free-electron laser (XFEL) facilities, such as those found at the Linac Coherent Light Source (LCLS). To address the resource constraints inherent in FPGAs, we developed a more specialized version of SpeckleNN. The original model, which was designed for broader classification across multiple biological samples, comprised ~5.6 million parameters. The new implementation, while reducing the parameter count to 64.6K (a 98.8% reduction), focuses on maintaining the model's essential functionality for real-time operation, achieving an accuracy of 90%. Furthermore, we compressed the latent space from 128 to 50 dimensions. This implementation was demonstrated on the KCU1500 FPGA board, utilizing 71% of available DSPs, 75% of LUTs, and 48% of FFs, with an average power consumption of 9.4W according to the Vivado post-implementation report. The FPGA performed inference on a single image with a latency of 45.015 microseconds at a 200 MHz clock rate. In comparison, running the same inference on an NVIDIA A100 GPU resulted in an average power consumption of ~73W and an image processing latency of around 400 microseconds. Our FPGA-accelerated version of SpeckleNN demonstrated significant improvements, achieving an 8.9 × speedup and a 7.8 × reduction in power consumption compared to the GPU implementation. Key advancements include model specialization and dynamic weight loading through SNL, which eliminates the need for time-consuming FPGA design re-synthesis, allowing fast and continuous deployment of models (re)trained online. These innovations enable real-time adaptive classification and efficient vetoing of speckle patterns, making SpeckleNN more suited for deployment in XFEL facilities. This implementation has the potential to significantly accelerate SPI experiments and enhance adaptability to evolving experimental conditions.

47 OTHER INSTRUMENTATION↗

Mars Odyssey Science: The First Year and Beyond

The 2001 Mars Odyssey orbital science mission officially began in late February, 2002. The spacecraft carries three science instrument packages: the Gamma Ray Spectrometer suite (GRS), the Thermal Emission Imaging System (THEMIS), and the Martian Radiation Environment Experiment (MARIE). The GRS suite of three instruments includes the Gamma Sensor Subsystem (GSS), the Neutron Spectrometer (NS) and the High Energy Neutron Detector (HEND). THEMIS consists of two cameras sharing a single set of telescopic optics: a 5-band visible imager and a 10-band thermal infrared imager. Spacecraft and instrument performance have been nominal to this point in the science mission.

Plaut, J. J.↗

Scanning Miniature Microscopes without Lenses

The figure schematically depicts some alternative designs of proposed compact, lightweight optoelectronic microscopes that would contain no lenses and would generate magnified video images of specimens. Microscopes of this type were described previously in Miniature Microscope Without Lenses (NPO - 20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43 and Reflective Variants of Miniature Microscope Without Lenses (NPO 20610), NASA Tech Briefs, Vol. 26, No. 9 (September 1999), page 6a. To recapitulate: In the design and construction of a microscope of this type, the focusing optics of a conventional microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. Elimination of focusing optics reduces the size and weight of the instrument and eliminates the need for the time-consuming focusing operation. The microscopes described in the cited prior articles contained two-dimensional CCDs registered with two-dimensional arrays of microchannels and, as such, were designed to produce full two-dimensional images, without need for scanning. The microscopes of the present proposal would contain one-dimensional (line image) CCDs registered with linear arrays of microchannels. In the operation of such a microscope, one would scan a specimen along a line perpendicular to the array axis (in other words, one would scan in pushbroom fashion). One could then synthesize a full two-dimensional image of the specimen from the line-image data acquired at one-pixel increments of position along the scan. In one of the proposed microscopes, a beam of unpolarized light for illuminating the specimen would enter from the side. This light would be reflected down onto the specimen by a nonpolarizing beam splitter attached to the microchannels at their lower ends. A portion of the light incident on the specimen would be reflected upward, through the beam splitter and along the microchannels, to form an image on the CCD. If the nonpolarizing beam splitter were replaced by a polarizing one, then the specimen would be illuminated by s-polarized light. Upon reflection from the specimen, some of the s-polarized light would become p-polarized. Only the p-polarized light would contribute to the image on the CCD; in other words, the image would contain information on the polarization rotating characteristic of the specimen.

Wang, Yu↗

Correcting for Nonlinearity in a Photodetector

Simple positive-feedback circuit varies bias voltage as necessary. Ideal detector biased with constant voltage, detector current proportional to photon flux plus constant offset. Detector connected between inverting input and ground, and feedback from operational amplifier through feedback resistor Rf make voltage at inverting input equal to noninverting input. Bias voltage held constant. Principle applied to linearizing mercury cadmium telluride infrared detectors in Fourier-transform spectrometers and other spectral and imaging instruments.

Schindler, R. A.↗

The Focusing Optics X-Ray Solar Imager: FOXSI

The Focusing Optics x-ray Solar Imager (FOXSI) is a sounding rocket payload funded under the NASA Low Cost Access to Space program to test hard x-ray (HXR) focusing optics and position-sensitive solid state detectors for solar observations. Today's leading solar HXR instrument, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) provides excellent spatial (2 arcseconds) and spectral (1 keV) resolution. Yet, due to its use of an indirect imaging system, the derived images have a low dynamic range (typically <10) and sensitivity. These limitations make it difficult to study faint x-ray sources in the solar corona which are crucial for understanding the particle acceleration processes which occur there. Grazing-incidence x-ray focusing optics combined with position-sensitive solid state detectors can overcome both of these limitations enabling the next breakthrough in understanding impulsive energy release on the Sun. The FOXSI project is led by the Space Sciences Laboratory at the University of California, Berkeley. The NASA Marshall Space Flight Center is responsible for the grazing-incidence optics, while the Astro-H team at JAXA/ISAS has provided double-sided silicon strip detectors. FOXSI is a pathfinder for the next generation of solar hard x-ray spectroscopic imagers. Such observatories will be able to image the non-thermal electrons within the solar flare acceleration region, trace their paths through the corona, and provide essential quantitative measurements such as energy spectra, density, and energy content in accelerated electrons.

Krucker, Saem↗

The Cosmic Microwave Background: Detection and Interpretation of the First Light

A host of astrophysical observations suggest the early Universe was incredibly hot, dense, and homogeneous. A powerful and useful probe of this epoch is provided by the relic radiation, which we refer to today as the Cosmic Microwave Background (CMB). Precision maps of this light contain the earliest glimpse of the Universe after the Big Bang and signatures of the evolution of its contents. By exploiting these clues, constraints on the age, mass density, detailed composition, and geometry of the Universe can be made. A brief survey of the evolution of the radiometric and polarimetric imaging systems used in advancing our understanding of the early Universe will be reviewed. A survey of detector technologies, instrumentation techniques, and experimental challenges encountered in these efforts will be presented.

polarimetric imaging systems↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Real-time streaming tomographic reconstruction with on-demand data capturing and 3D zooming to regions of interest

Complex dynamic tomographic experiments at brilliant X-ray light sources require real-time feedback on the sample changes with respect to environmental conditions, selecting representative regions of interest for high-resolution scanning, and on-demand data saving mechanisms for storing only relevant projections acquired by fast area detectors and reducing data volumes. Here the implementation details of a 3D real-time imaging monitoring instrument, with zooming to a volume of interest with easy-to-use visualization via ImageJ , a tool familiar to most beamline users, is presented. The instrument relies on optimized data flow between the detector and processing machines and is implemented on commodity computers. The instrument has been developed at beamline 2-BM of the Advanced Photon Source, where the automatic lens changing mechanism for zooming is implemented with an Optique Peter microscope. Performance tests demonstrate the ability to process more than 3 GB of projection data per second and generate real-time 3D zooming with different magnification. These new capabilities are essential for new APS Upgrade instruments such as the projection microscope under development at beamline 32-ID. The efficacy of the proposed instrument was demonstrated during an in situ tomographic experiment on ice and gas hydrate formation in porous samples.

3D zooming↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

Optical Fiber Array Assemblies for Space Flight on the Lunar Reconnaissance Orbiter

Custom fiber optic bundle array assemblies developed by the Photonics Group at NASA Goddard Space Flight Center were an enabling technology for both the Lunar Orbiter Laser Altimeter (LOLA) and the Laser Ranging (LR) Investigation on the Lunar Reconnaissance Orbiter (LRO) currently in operation. The unique assembly array designs provided considerable decrease in size and weight and met stringent system level requirements. This is the first time optical fiber array bundle assemblies were used in a high performance space flight application. This innovation was achieved using customized Diamond Switzerland AVIM optical connectors. For LOLA, a five fiber array was developed for the receiver telescope to maintain precise alignment for each of the 200/220 micron optical fibers collecting 1,064 nm wavelength light being reflected back from the moon. The array splits to five separate detectors replacing the need for multiple telescopes. An image illustration of the LOLA instrument can be found at the top of the figure. For the laser ranging, a seven-optical-fiber array of 400/440 micron fibers was developed to transmit light from behind the LR receiver telescope located on the end of the high gain antenna system (HGAS). The bundle was routed across two moving gimbals, down the HGAS boom arm, over a deployable mandrel and across the spacecraft to a detector on the LOLA instrument. The routing of the optical fiber bundle and its end locations is identified in the figure. The Laser Ranging array and bundle is currently accepting light at a wavelength of 532 nm sent to the moon from laser stations at Greenbelt MD and other stations around the world to gather precision ranging information from the Earth to the LRO spacecraft. The LR bundle assembly is capable of withstanding temperatures down to -55 C at the connectors, and 20,000 mechanical gimbal cycles at temperatures as cold as -20 C along the length of the seven-fiber bundle (that is packaged into the gimbals). The total bundle assembly is 10 meters long with two interconnections requiring precise clocking of the seven-fiber array pattern.

Ott, Jelanie↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Method and apparatus for radiometer star sensing

A method and apparatus for determining the orientation of the optical axis of radiometer instruments mounted on a satellite involves a star sensing technique. The technique makes use of a servo system to orient the scan mirror of the radiometer into the path of a sufficiently bright star such that motion of the satellite will cause the star's light to impinge on the scan mirror and then the visible light detectors of the radiometer. The light impinging on the detectors is converted to an electronic signal whereby, knowing the position of the star relative to appropriate earth coordinates and the time of transition of the star image through the detector array, the orientation of the optical axis of the instrument relative to earth coordinates can be accurately determined.

Wilcox, Jack E.↗