Copy of Modeling Tribal Leadership: An opinion dynamics model of the traditional Pashtun tribal balance of power.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
This report documents the efforts to perform dynamic model validation on the Eastern Interconnection (EI) by modeling governor deadband. An on-peak EI dynamic model is modified to represent governor deadband characteristics. Simulation results are compared with synchrophasor measurements collected by the Frequency Monitoring Network (FNET/GridEye). The comparison shows that by modeling governor deadband the simulated frequency response can closely align with the actual system response.
The natural sway of crane payloads is detrimental to safe and efficient operation. Under certain conditions, the problem is complicated when the payloads create a double pendulum effect. This paper presents dynamic modelling of a double-pendulum gantry crane system based on closed-form equations of motion. The Lagrangian method is used to derive the dynamic model of the system. A dynamic model of the system incorporating payload is developed and the effects of payload on the response of the system are discussed. Extensive results that validate the theoretical derivation are presented in the time and frequency domains.
Learning a latent-dynamics model for complex real-world physical processes is indispensable. Most previous latent-dynamics modeling approaches suffer from the violation of important physical properties such as conservation.
Photovoltaic (PV) modules have dramatically decreased in price in the past few years, spurring the expansion of photovoltaic deployment. Residential and commercial rooftop installations are connected to the distribution network; large-scale installation PV power plants (PVPs) have benefited from tax incentives and the low cost of PV modules. As the level penetration of PV generation increases, the impact on power system reliability will also be greater. Utility power system planners must consider the role of PV generation in power systems more realistically by representing PV generation in dynamic stability analyses. Dynamic models of PV inverters have been developed in the positive sequence representation. NREL has developed a PV inverter dynamic model in PSCAD/EMTDC. This paper validates the dynamic model with an actual hardware bench test conducted by Southern California Edison's Distributed Energy Resources laboratory. All the fault combinations -- symmetrical and unsymmetrical -- were performed in the laboratory. We compare the simulation results with the bench test results.
This paper presents a spatiotemporal dynamic model based on the interaction between multiple shear bands in the plastic flow of metallic glasses during compressive deformation. Various sizes of sliding events burst in the plastic deformation as the generation of different scales of shear branches occurred; microscopic creep events and delocalized sliding events were analyzed based on the established model. This paper discusses the spatially uniform solutions and traveling wave solution. The phase space of the spatially uniform system applied in this study reflected the chaotic state of the system at a lower strain rate. Moreover, numerical simulation showed that the microscopic creep events were manifested at a lower strain rate, whereas the delocalized sliding events were manifested at a higher strain rate.
A new dynamical model is developed to describe the whole process of surrogate reactions: Transfer of several nucleons at an initial stage, thermal equilibration of residues leading to washing out of shell effects, and decay of populated compound nuclei are treated in a unified framework. Multidimensional Langevin equations are employed to describe time evolution of collective coordinates with a time-dependent potential energy surface corresponding to different stages of surrogate reactions. The new model is capable of calculating spin distributions of the compound nuclei, one of the most important quantities in the surrogate technique. Furthermore, various observables of surrogate reactions can be calculated, for example, energy and angular distribution of ejectile and mass distributions of fission fragments. These features are important to assess validity of the proposed model itself, to understand mechanisms of the surrogate reactions, and to determine unknown parameters of the model. It is found that spin distributions of compound nuclei produced in {sup 18}O+{sup 238}U{yields}{sup 16}O+{sup 240}*U and {sup 18}O+{sup 236}U{yields}{sup 16}O+{sup 238}*U reactions are equivalent and much less than 10({h_bar}/2{pi}) and therefore satisfy conditions proposed by Chiba and Iwamoto [Phys. Rev. C 81, 044604 (2010)] if they are used as a pair in the surrogate ratio method.
A dynamic model of the starting current of an active damper based on a magnetorheological elastomer is described, Experimental data for the damper are derived.
Here, we present a hierarchical multiscale modeling study of implanted helium (He) segregation near grain boundaries (GBs) of tungsten. We extend our spatially dependent cluster dynamics model to two spatial dimensions in order to take into account the biased drift of mobile He clusters toward the GBs observed in atomic-scale simulations. We are also able to reproduce the results from large-scale molecular dynamics simulations near and away from the GBs at low fluence with the extended cluster dynamics model. We suggest and verify that the sink (surface and GB) strengths are attenuated by the increasing concentration of He clusters at high fluence. This cluster dynamics model continues to set the stage for development of fully atomistically informed, coarse-grained models for computationally efficient predictions of He retention and surface morphological evolution, advancing progress toward the goal of efficient and optimal design of plasma-facing components.
A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.
The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.
We present a dynamical model of the high mass X-ray binary LMC X-1 based on high-resolution optical spectroscopy and extensive optical and near-infrared photometry. From our new optical data we find an orbital period of P = 3.90917 {+-} 0.00005 days. We present a refined analysis of the All Sky Monitor data from RXTE and find an X-ray period of P = 3.9094 {+-} 0.0008 days, which is consistent with the optical period. A simple model of Thomson scattering in the stellar wind can account for the modulation seen in the X-ray light curves. The V - K color of the star (1.17 {+-} 0.05) implies A{sub V} = 2.28 {+-} 0.06, which is much larger than previously assumed. For the secondary star, we measure a radius of R {sub 2} = 17.0 {+-} 0.8 R {sub sun} and a projected rotational velocity of V {sub rot}sin i = 129.9 {+-} 2.2 km s{sup -1}. Using these measured properties to constrain the dynamical model, we find an inclination of i = 36.{sup 0}38 {+-} 1.{sup 0}92, a secondary star mass of M {sub 2} = 31.79 {+-} 3.48 M {sub sun}, and a black hole mass of 10.91 {+-} 1.41 M {sub sun}. The present location of the secondary star in a temperature-luminosity diagram is consistent with that of a star with an initial mass of 35 M {sub sun} that is 5 Myr past the zero-age main sequence. The star nearly fills its Roche lobe ({approx}90% or more), and owing to the rapid change in radius with time in its present evolutionary state, it will encounter its Roche lobe and begin rapid and possibly unstable mass transfer on a timescale of a few hundred thousand years.
We present dynamical modeling of the broad-line region (BLR) in the Seyfert 1 galaxy Mrk 50 using reverberation mapping data taken as part of the Lick AGN Monitoring Project (LAMP) 2011. We model the reverberation mapping data directly, constraining the geometry and kinematics of the BLR, as well as deriving a black hole mass estimate that does not depend on a normalizing factor or virial coefficient. We find that the geometry of the BLR in Mrk 50 is a nearly face-on thick disk, with a mean radius of 9.6{sup +1.2}{sub -0.9} light days, a width of the BLR of 6.9{sup +1.2}{sub -1.1} light days, and a disk opening angle of 25 {+-} 10 deg above the plane. We also constrain the inclination angle to be 9{sup +7}{sub -5} deg, close to face-on. Finally, the black hole mass of Mrk 50 is inferred to be log{sub 10}(M{sub BH}/M{sub Sun }) = 7.57{sup +0.44}{sub -0.27}. By comparison to the virial black hole mass estimate from traditional reverberation mapping analysis, we find the normalizing constant (virial coefficient) to be log{sub 10} f = 0.78{sup +0.44}{sub -0.27}, consistent with the commonly adopted mean value of 0.74 based on aligning the M{sub BH}-{sigma}* relation for active galactic nuclei and quiescent galaxies. While our dynamical model includes the possibility of a net inflow or outflow in the BLR, we cannot distinguish between these two scenarios.
Here, this article introduces ways to identify dynamic system models using measurement data. In power system analysis, a static model represents the time-invariant input-output relationship of a system, while a dynamic model describes the behavior of the system over time. For example, how will a system transit from one steady-state operation point to another?
Dynamic models for power plants that capture realistic general process trends and effects of manipulated variables are needed to improve load-following, while minimizing carbon footprint. In this work, a dynamic modeling approach and simulation results for subcritical coal-fired power plant components are presented. These encompass simulation of the dynamics in the fireside, including the effects of fuel, air combustion, and the dynamics of the entire waterside and power generation sections. This model development enables the simulation and analysis of the important short and long-time scale dynamics of components such as heaters, evaporative loop, and power generation units. Furthermore, additional variables in the power generation section are introduced to improve model accuracy, extending the prediction capability of subcritical power plant models and opening new opportunities for research in operator training, optimization, and advanced model-based controller design that are based on these models. The change in process gain for different ramp rates associated with disturbance signals that affect process variables is also explored and a correlation developed. This provides opportunities to study disturbance rejection control implementation and adaptation for scenarios with such variations in ramp rates. The prediction capabilities of selected components are compared to data available in literature, with the obtained root mean squared error ranges that reflect the model performance and quality of predictions.
This paper provides lessons learned from developing several large system dynamics (SD) models. System dynamics modeling practice emphasize the need to keep models small so that they are manageable and understandable. This practice is generally reasonable and prudent; however, there are times that large SD models are necessary. This paper outlines two large SD projects that were done at two Department of Energy National Laboratories, the Idaho National Laboratory and Sandia National Laboratories. This paper summarizes the models and then discusses some of the valuable lessons learned during these two modeling efforts.
Serving as a prerequisite to power system dynamic state estimation, the observability analysis of a power system dynamic model has recently attracted the attention of many power engineers. However, because this model is typically nonlinear and large-scale, the analysis of its observability is a challenge to the traditional derivative-based methods. Indeed, the linear-approximation-based approach may provide unreliable results while the nonlinear-technique-based approach inevitably faces extremely complicated derivations. Furthermore, because power systems are intrinsically stochastic, the traditional deterministic approaches may lead to inaccurate observability analyses. In this work, facing these challenges, we propose a novel polynomial-chaos-based derivative-free observability analysis approach that not only is free of any linear approximations, but also accounts for the stochasticity of the dynamic model while bringing a low implementation complexity. Furthermore, this approach enables us to quantify the degree of observability of a stochastic model, what conventional deterministic methods cannot do. The excellent performance of the proposed method has been demonstrated by performing extensive simulations using a synchronous generator model with IEEE-DC1A exciter and the TGOV1 turbine governor.