Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIFFERENTIAL AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Recent advances in capacitance type of blade tip clearance measurements

Two recent electronic advances at NASA-Lewis that meet the blade tip clearance needs of a wide class of fans, compressors, and turbines are described. The first is a frequency modulated (FM) oscillator that requires only a single low cost ultrahigh frequency operational amplifier. Its carrier frequency is 42.8 MHz when used with a 61 cm long hermetically sealed coaxial cable. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a typical rotor blade. High temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum which produces a clearance error of + or - 10 microns at a clearance of 500 microns. In the second advance, a guarded probe configuration allows a longer cable capacitance. The capacitance of the probe is part of a small time constant feedback in a high speed operational amplifier. The solution of the governing differential equation is applied to a ramp type of input. The results show an amplifier output that contains a term which is proportional to the derivative of the feedback capacitance. The capacitance is obtained by subtracting a balancing reference channel followed by an integration stage.

Barranger, John P.↗

A cryogenic multichannel electronically scanned pressure module

Consideration is given to a cryogenic multichannel electronically scanned pressure (ESP) module developed and tested over an extended temperature span from -184 to +50 C and a pressure range of 0 to 5 psig. The ESP module consists of 32 pressure sensor dice, four analog 8 differential-input multiplexers, and an amplifier circuit, all of which are packaged in a physical volume of 2 x 1 x 5/8 in with 32 pressure and two reference ports. Maximum nonrepeatability is measured at 0.21 percent of full-scale output. The ESP modules have performed consistently well over 15 times over the above temperature range and continue to work without any sign of degradation. These sensors are also immune to repeated thermal shock tests over a temperature change of 220 C/sec.

Shams, Qamar A.↗

Use of the quartz crystal microbalance to determine the monomeric friction coefficient of polyimides

When a thin film of polymer is coated on to a quartz crystal microbalance (QCM), the QCM can be used to detect the rate of increase in weight of the polymer film as the volatile penetrant diffuses into the polymer. From this rate information the diffusion coefficient of the penetrant into the polymer can be computed. Calculations requiring this diffusion coefficient lead to values which approximate the monomeric friction coefficient of the polymer. This project has been concerned with the trial of crystal oscillating circuits suitable for driving polymer coated crystals in an atmosphere of penetrant. For these studies done at room temperature, natural rubber was used as an easily applied polymer that is readily penetrated by toluene vapors, qualities anticipated with polyimides when they are tested at T(g) in the presence of toluene. Three quartz crystal oscillator circuits were tested. The simplest circuit used +/- 5 volt dc and had a transistor to transistor logic (TTL) inverter chip that provides a 180 deg phase shift via a feed back loop. This oscillator circuit was stable but would not drive the crystal when the crystal was coated with polymer and subjected to toluene vapors. Removal of a variable resistor from this circuit increased stability but did not otherwise increase performance. Another driver circuit tested contained a two stage differential input, differential output, wide band video amplifier and also contain a feed back loop. The circuit voltage could not be varied and operated at +/- 5 volts dc; this circuit was also stable but failed to oscillate the polymer coated crystal in an atmosphere saturated with toluene vapors. The third oscillator circuit was of similar construction and relied on the same video amplifier but allowed operation with variable voltage. This circuit would drive the crystal when the crystal was submerged in liquid toluene and when the crystal was coated with polymer and immersed in toluene vapors. The frequency readings obtained when using this oscillating circuit are highly variable. This circuit requires further modification to stabilize frequency readings before its use in studies to determine the diffusion coefficient of penetrant molecules into a polymer film coated on a QCM.

Bechtold, Mary M.↗

An alexandrite regenerative amplifier for water vapor and temperature measurements

The Differential Absorption Lidar (DIAL) technique is a powerful method for determining meteorological parameters, but it requires high quality of the laser source: high energy, very narrow bandwidth, high wavelength stability, and spectral purity. Although many efforts have been made to improve the lasers in view of these aspects, a satisfactory solution has not been demonstrated up to now. We describe a regenerative amplifier, using a Ti:sapphire laser as master oscillator and an alexandrite laser as slave amplifier, which is expected to meet the requirements for water vapor concentration and temperature measurements.

Thro, P.-Y.↗

Field effect transistors improve buffer amplifier

Unity gain buffer amplifier with a Field Effect Transistor /FET/ differential input stage responds much faster than bipolar transistors when operated at low current levels. The circuit uses a dual FET in a unity gain buffer amplifier having extremely high input impedance, low bias current requirements, and wide bandwidth.

Source record↗

Window comparator

A window comparator is described, comprising two operational amplifiers, one with two feedback circuits, each feedback circuit having a diode connected to the amplifier output and poled for forward current conduction of opposite polarity, to provide an algebraic difference between an input signal and a selected set-point voltage. Differential input terminals of the second operational amplifier were connected to the separate feedback circuits of the first operational amplifier, one input terminal to the output of one diode, and the other to the output of the other diode. A selected window-width voltage was connected through a coupling resistor to one of the input terminals of the second operational amplifier to determine when the algebraic difference of the input signal and the setpoint voltage has exceeded a predetermined tolerance after that difference has changed signs.

Black, J. M.↗

Wind tunnel tests of a symmetrical airfoil with scoop fed slots

The design and wind tunnel test of a model vertical tail fin is described in this report. The model is designed to provide the aerodynamic forces necessary for lateral stabilization without moving parts or a separate source of power. It employs scoop-fed slots on both surfaces of the symmetrical airfoil. They are to be controlled differentially by means of a fluidic amplifier to implement an automatic fulltime lateral stabilization system. The results of tests show that the control of forces is stable and quite linear in various modes of operation. Significant forces were produced that can be increased as necessary by increasing slot size and scoop size. Slots can be located ahead of the conventional rudder and the scoop can be at the base of the vertical tail fin to avoid the need for major changes in conventional aircraft design. The first phase of the work demonstrated the feasibility of no-moving-parts aircraft control. The second phase established that a practical fluidic amplifier can be built to control slot flows from fluidic signals. Recommendations are made to optimize the design of the fluidic amplifier and to characterize its dynamic response in support of further analytical studies.

Belsterling, C. A.↗

Solar energy control system

A solar energy control system for a hot air type solar energy heating system wherein thermocouples are arranged to sense the temperature of a solar collector, a space to be heated, and a top and bottom of a heat storage unit is disclosed. Pertinent thermocouples are differentially connected together, and these are employed to effect the operation of dampers, a fan, and an auxiliary heat source. In accomplishing this, the differential outputs from the thermocouples are amplified by a single amplifier by multiplexing techniques. Additionally, the amplifier is corrected as to offset by including as one multiplex channel a common reference signal.

Currie, J. R.↗

Fidelity and enhanced sensitivity of differential transcription profiles following linear amplification of nanogram amounts of endothelial mRNA

Although mRNA amplification is necessary for microarray analyses from limited amounts of cells and tissues, the accuracy of transcription profiles following amplification has not been well characterized. We tested the fidelity of differential gene expression following linear amplification by T7-mediated transcription in a well-established in vitro model of cytokine [tumor necrosis factor alpha (TNFalpha)]-stimulated human endothelial cells using filter arrays of 13,824 human cDNAs. Transcriptional profiles generated from amplified antisense RNA (aRNA) (from 100 ng total RNA, approximately 1 ng mRNA) were compared with profiles generated from unamplified RNA originating from the same homogeneous pool. Amplification accurately identified TNFalpha-induced differential expression in 94% of the genes detected using unamplified samples. Furthermore, an additional 1,150 genes were identified as putatively differentially expressed using amplified RNA which remained undetected using unamplified RNA. Of genes sampled from this set, 67% were validated by quantitative real-time PCR as truly differentially expressed. Thus, in addition to demonstrating fidelity in gene expression relative to unamplified samples, linear amplification results in improved sensitivity of detection and enhances the discovery potential of high-throughput screening by microarrays.

Evaluation Studies↗

Tiny biomedical amplifier combines high performance, low power drain

Transistorized, portable, high performance amplifier with low power drain facilitates biomedical studies on mobile subjects. This device, which utilizes a differential input to obtain a common-mode rejection, is used for amplifying electrocardiogram and electromyogram signals.

Deboo, G. J.↗

Long-term variations in abundance and distribution of sulfuric acid vapor in the Venus atmosphere inferred from Pioneer Venus and Magellan radio occultation studies

Radio occultation experiments have been used to study various properties of planetary atmospheres, including pressure and temperature profiles, and the abundance profiles of absorbing constituents in those planetary atmospheres. However, the reduction of amplitude data from such experiments to determine abundance profiles requires the application of the inverse Abel transform (IAT) and numerical differentiation of experimental data. These two operations preferentially amplify measurement errors above the true signal underlying the data. A new technique for processing radio occultation data has been developed that greatly reduces the errors in the derived absorptivity and abundance profiles. This technique has been applied to datasets acquired from Pioneer Venus Orbiter radio occultation studies and more recently to experiments conducted with the Magellan spacecraft. While primarily designed for radar studies of the Venus surface, the high radiated power (EIRP) from the Magellan spacecraft makes it an ideal transmitter for measuring the refractivity and absorptivity of the Venus atmosphere by such experiments. The longevity of the Pioneer Venus Orbiter has made it possible to study long-term changes in the abundance and distribution of sulfuric acid vapor, H2SO4(g), in the Venus atmosphere between 1979 and 1992. The abundance of H2SO4(g) can be inferred from vertical profiles of 13-cm absorptivity profiles retrieved from radio occultation experiments. Data from 1979 and 1986-87 suggest that the abundance of H2SO4(g) at latitudes northward of 70 deg decreased over this time period. This change may be due to a period of active volcanism in the late 1970s followed by a relative quiescent period, or some other dynamic process in the Venus atmosphere. While the cause is not certain, such changes must be incorporated into dynamic models of the Venus atmosphere. Potentially, the Magellan spacecraft will extend the results of Pioneer Venus Orbiter and allow the continued monitoring of the abundance of distribution of H2SO4(g) in the Venus atmosphere, as well as other interesting atmospheric properties. Without such measurements it will be difficult to address other issues such as the short-term spatial variability of the abundance of H2SO4(g) at similar latitudes in Venus atmosphere, and the identities of particles responsible for large-scale variations observed in NIR images.

Jenkins, J. M.↗

Airborne Lidar Measurements of Atmospheric Pressure Made Using the Oxygen A-Band

Accurate measurements of greenhouse gas mixing ratios on a global scale are currently needed to gain a better understanding of climate change and its possible impact on our planet. In order to remotely measure greenhouse gas concentrations in the atmosphere with regard to dry air, the air number density in the atmosphere is also needed in deriving the greenhouse gas concentrations. Since oxygen is stable and uniformly mixed in the atmosphere at 20.95%, the measurement of an oxygen absorption in the atmosphere can be used to infer the dry air density and used to calculate the dry air mixing ratio of a greenhouse gas, such as carbon dioxide or methane. OUT technique of measuring Oxygen uses integrated path differential absorption (IPDA) with an Erbium Doped Fiber Amplifier (EDF A) laser system and single photon counting module (SPCM). It measures the absorbance of several on- and off-line wavelengths tuned to an O2 absorption line in the A-band at 764.7 nm. The choice of wavelengths allows us to maximize the pressure sensitivity using the trough between two absorptions in the Oxygen A-band. Our retrieval algorithm uses ancillary meteorological and aircraft altitude information to fit the experimentally obtained lidar O2 line shapes to a model atmosphere and derives the pressure from the profiles of the two lines. We have demonstrated O2 measurements from the ground and from an airborne platform. In this paper we will report on our airborne measurements during our 2011 campaign for the ASCENDS program.

Riris, Haris↗

1.6-μm Er:YGG Waveguide Amplifiers

We report on the fabrication and characterization of Er:YGG films suitable for waveguide amplifiers that could in principle be used in integrated path differential absorption lidar systems. Presented is our fabrication technique, comprising pulsed-laser-deposition growth of ~10 μm-thick crystalline films, their channeling via ultraprecision ductile dicing with a diamond-blade, producing optical quality facets and sidewalls, and amplifier performance. Net gain at 1572 nm and 1651 nm is obtained for the first time in Er-doped YGG waveguide amplifiers. Additionally, in a channel waveguide a maximum internal gain of 3.5 dB/cm at the 1533nm peak was realized. Recent crystal film quality improvements promise further performance enhancements needed for the intended application for high-peak power sources in the 1.6-μm spectral region targeting Earth observation systems for monitoring greenhouse gases.

greenhouse gases; planar waveguide amplifiers↗

Molecular-Beam Chopper and Four-Channel Amplifier

Molecular-beam chopper phase controller and timing interface is subsystem of four-stage, differentially pumped, modulated molecular-beam/mass spectrometer. Subsystem maintains accurate phase control and timing for repetitive signal averaging over several hours of operation. Chopper phase controller/ timing interface and four-channel programable time-multiplexed amplifier provide substantial improvements in attainable signal-to-noise ratio, detection limit, and accuracy of molecular-beam/mass-spectrometer system.

Adams, B. R.↗

Superconducting gravity gradiometer and a test of inverse square law

The equivalence principle prohibits the distinction of gravity from acceleration by a local measurement. However, by making a differential measurement of acceleration over a baseline, platform accelerations can be cancelled and gravity gradients detected. In an in-line superconducting gravity gradiometer, this differencing is accomplished with two spring-mass accelerometers in which the proof masses are confined to motion in a single degree of freedom and are coupled together by superconducting circuits. Platform motions appear as common mode accelerations and are cancelled by adjusting the ratio of two persistent currents in the sensing circuit. The sensing circuit is connected to a commercial SQUID amplifier to sense changes in the persistent currents generated by differential accelerations, i.e., gravity gradients. A three-axis gravity gradiometer is formed by mounting six accelerometers on the faces of a precision cube, with the accelerometers on opposite faces of the cube forming one of three in-line gradiometers. A dedicated satellite mission for mapping the earth's gravity field is an important one. Additional scientific goals are a test of the inverse square law to a part in 10(exp 10) at 100 km, and a test of the Lense-Thirring effect by detecting the relativistic gravity magnetic terms in the gravity gradient tensor for the earth.

Moody, M. V.↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials, part 1

The use of pressure differentials in a flight control system was evaluated. The pressure profile around the test surface was determined using two techniques: (1) windtunnel data (actual); and (2) NASA/Langley Single Element Airfoil Computer Program (theoretical). The system designed to evaluate the concept of using pressure differentials is composed of a sensor drive and power amplifiers, actuator, position potentiometer, and a control surface. The characteristics (both desired and actual) of the system and each individual component were analyzed. The desired characteristics of the system as a whole are given. The flight control system developed, the testing procedures and data reduction methods used, and theoretical frequency response analysis are described.

Hrabak, R. R.↗

$\mathrm{SageNet}$: Fast Neural Network Emulation of the Stiff-amplified Gravitational Waves from Inflation

Accurate modeling of the inflationary gravitational waves (GWs) requires time-consuming, iterative numerical integrations of differential equations to take into account their backreaction on the expansion history. To improve computational efficiency while preserving accuracy, we present the Stiff-amplified Gravitational-wave Emulator Network (SageNet), a deep learning framework designed to replace conventional numerical solvers (code available at https://github.com/YifangLuo/SageNet). SageNet employs a long short-term memory architecture to emulate the present-day energy density spectrum of the inflationary GWs with possible stiff amplification, Ω GW (f). Trained on a data set of 25,689 numerically generated solutions, SageNet allows accurate reconstructions of Ω GW (f) and generalizes well to a wide range of cosmological parameters; 90.9% of the test emulations with randomly distributed parameters exhibit errors of under 4%. In addition, SageNet demonstrates its ability to learn and reproduce the artificial, adaptive sampling patterns in numerical calculations, which implement denser sampling of frequencies around changes in spectral indices in Ω GW (f). The dual capability of learning both physical and artificial features of the numerical GW spectra establishes SageNet as a robust alternative to exact numerical methods. Finally, our benchmark tests show that SageNet reduces the computation time from tens of seconds to milliseconds, achieving a speedup of ∼10 4 times over standard CPU-based numerical solvers with the potential for further acceleration on GPU hardware. These capabilities make SageNet a powerful tool for accelerating Bayesian inference procedures for extended cosmological models. In a broad sense, the SageNet framework offers a fast, accurate, and generalizable solution to modeling cosmological observables whose theoretical predictions demand costly differential equation solvers.

Astronomy data modeling↗