Techniques for improving the opening of the main diaphragm in a large combustion driver
Techniques for improving main diaphragm opening in large combustion driver
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Techniques for improving main diaphragm opening in large combustion driver
Metallic expulsion diaphragm for single-cycle positive expulsion of high temperature liquid in gravity condition
Divergent nozzle location effects on viscous and diaphragm problems in expansion tube supersonic flow
Eighteen-inch expulsion diaphragm recycleability and fabrication from stainless steel and titanium
Manufacturing and test procedures for fuel and oxidizer burst diaphragms for Aerobee 350 propellant start valves
Latch diaphragm release mechanism for payload separation in space
The development of displacement based approaches for earthquake engineering design appears to be very useful and capable to provide improved reliability by directly comparing computed response and expected structural performance. In particular, the design procedure known as the Direct Displacement Based Design (DDBD) method, which has been developed in structural engineering over the past ten years in the attempt to mitigate some of the deficiencies in current force-based design methods, has been shown to be very effective and promising ([1], [2]). The first attempts of application of the procedure to geotechnical engineering and, in particular, earth retaining structures are discussed in [3], [4] and [5]. However in this field, the outcomes of the research need to be further investigated in many aspects. The paper focuses on the application of the DDBD method to anchored diaphragm walls. The results of the DDBD method are discussed in detail in the paper, and compared to those obtained from conventional pseudo-static analyses.
Here, we report advanced materials and devices that enable high-efficiency mechanical-to-electrical energy conversion from the natural contractile and relaxation motions of the heart, lung, and diaphragm, demonstrated in several different animal models, each of which has organs with sizes that approach human scales. Here, a cointegrated collection of such energy-harvesting elements with rectifiers and microbatteries provides an entire flexible system, capable of viable integration with the beating heart via medical sutures and operation with efficiencies of ~2%. Additional experiments, computational models, and results in multilayer configurations capture the key behaviors, illuminate essential design aspects, and offer sufficient power outputs for operation of pacemakers, with or without battery assist.
Many piezoelectric microelectromechanical systems (MEMS) measure or generate acoustic signals via the motion of radially non-uniform, thin film composite plates. The composite layers provide piezoelectric actuation, structural support, electrode metallization, passivation, etc. Often, the layers are non-uniform over the plate and contain residual stresses introduced during the fabrication process. Accurate models of non-uniform composite plate mechanics are crucial for predicting and optimizing device performance. In this paper, an analytical solution for a radially non-uniform, piezoelectric, circular composite plate incorporating residual stress is derived. The analytical solution is compared to experimental measurements of a MEMS piezoelectric diaphragm. The results show the improved accuracy of the analytical model when including film stress, the speed of the analytical solution as compared to finite element analysis, the sensitivity of device performance to residual stress and the importance of accurate film stresses as model inputs. Finally, the analytical model presented is useful as a design optimization tool given the efficiency of the computational time, shown to be 275 times less than a comparable finite element analysis.
Dynamic comparative calibration system measures response of miniature pressure transducers. The system is composed of an electromechanically driven metal diaphragm, a calibrated and an uncalibrated transducer and an oscillator.
Supported dual-mode burst diaphragm protects vacuum vessels from transient internal pressures. It forms the interface between the vacuum in the vessel and an external pressure.
Cathode support structure designed around a titanium diaphragm prevents radial misalignment between the cathode and anode in amplitrons. The titanium exhibits low thermal conductivity, tolerates lateral thermal expansion of the cathode, and is a poor primary and secondary emission medium.
Die and punch set forms convolutions in thin dished metal diaphragm without stretching the metal too thin at sharp curvatures. The die corresponds to the metal shape to be formed, and the punch consists of elements that progressively slide against one another under the restraint of a compressed-air cushion to mate with the die.
Radial, diaphragm separated injection method for variable thrust liquid rocket engines with or without mixture ratio variation
Diaphragm spring clutch mechanism is used in testing the relative merits of eddy-current and hysteresis dampers. The dampers are alternately coupled to a single damping boom shaft. The floating clutch mechanism enables the inoperative damper to remain completely isolated from the damping boom shaft during test of the other damper.
Vibrating diaphragm transducer for pressure measurements in wind tunnels - construction, sensitivity, stability, energy losses, and cost estimate
Lithium hydride cell uses vanadium diaphragm electrode as a hydrogen diffuser. Vanadium is high in hydrogen gas solubility and permeability, is least sensitive to adverse surface effects, maintains good mechanical strength in hydrogen atmospheres, and appears to be compatible with all alkali-halide electrolytes and lithium metals.
Influence of transverse diaphragm rigidity on temperature stresses in thin walled bars and shells of closed and open profile