Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAGNOSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A unified large language model–based framework for heterogeneous PV image diagnosis

With advances in imaging technologies, modern photovoltaic (PV) systems generate large volumes of heterogeneous image data, including visible, electroluminescence (EL), and infrared (IR) images. Existing PV image analysis models, particularly deep learning approaches, are typically task-specific and lack cross-modality generalization. To address this limitation, this paper proposes an open-source large language model (LLM)–based unified framework for heterogeneous PV image diagnostics. Through task-aware diagnostic prompting, the framework enables analysis of visible, EL, and IR images within a single pipeline, supporting both zero-shot and few-shot inference and binary and multiclass classification. It is compatible with state-of-the-art multimodal LLMs, including ChatGPT, Gemini, Claude, Qwen, and CLIP. The framework is evaluated on PV module condition classification (clean, soiling, snow, hail, and bird droppings) using visible images, cell crack detection using EL images, and hotspot detection using IR images. GPT-5.1 in few-shot mode achieves the best performance, with classification accuracy exceeding 97.3%. Open-source models such as Qwen and CLIP also deliver competitive results on visible images (around 90% accuracy), though their performance is more limited on EL and IR modalities. On the full ELPV dataset, the framework achieves 83.5% zero-shot accuracy, within 2.8% of the supervised CNN baseline, confirming scalability to larger benchmarks. Practical aspects such as reproducibility, response latency, and confidence estimation are systematically analyzed. The framework operates across PV image modalities without modality- or task-specific training, making it well suited as a rapid pre-screening tool to support downstream detailed diagnostics. A benchmark dataset of diverse labeled PV images is also released.

Li, Baojie↗

Diagnosis of Alzheimer’s disease using plasma biomarkers adjusted to clinical probability

Abstract Recently approved anti-amyloid immunotherapies for Alzheimer’s disease (AD) require evidence of amyloid-β pathology from positron emission tomography (PET) or cerebrospinal fluid (CSF) before initiating treatment. Blood-based biomarkers promise to reduce the need for PET or CSF testing; however, their interpretation at the individual level and the circumstances requiring confirmatory testing are poorly understood. Individual-level interpretation of diagnostic test results requires knowledge of disease prevalence in relation to clinical presentation (clinical pretest probability). Here, in a study of 6,896 individuals evaluated from 11 cohort studies from six countries, we determined the positive and negative predictive value of five plasma biomarkers for amyloid-β pathology in cognitively impaired individuals in relation to clinical pretest probability. We observed that p-tau217 could rule in amyloid-β pathology in individuals with probable AD dementia (positive predictive value above 95%). In mild cognitive impairment, p-tau217 interpretation depended on patient age. Negative p-tau217 results could rule out amyloid-β pathology in individuals with non-AD dementia syndromes (negative predictive value between 90% and 99%). Our findings provide a framework for the individual-level interpretation of plasma biomarkers, suggesting that p-tau217 combined with clinical phenotyping can identify patients where amyloid-β pathology can be ruled in or out without the need for PET or CSF confirmatory testing.

Cell Biology↗

Open-circuit submodule fault diagnosis in MMCs using support vector machines

Series connection of semiconductor submodules (SM) in a modular multilevel converter (MMC) makes the MMC prone to open-circuit (OC) IGBT failures inside SMs. If left undetected, these faults degrade the operation of the MMC and lead to its instability. This article proposes a method to detect, localise, and classify single OC SM faults in an MMC using support vector machines (SVM) trained with data obtained from the capacitor voltage balancing block of the MMC control system. The proposed method relies on data extracted from the sorted capacitor voltage arrays of the upper and lower phase arms. Therefore, it does not require extra measurements and hardware. Additionally, it offers a fixed time for detecting and localising OC SM faults. This method is easy to implement as SVM has a simple decision function. Time-domain simulation case studies are performed on a three-phase nine-level MMC to evaluate the performance of the proposed method.

42 ENGINEERING↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosis of the imploding shell asymmetry in polar-direct-drive deuterium–tritium cryogenic target implosions on OMEGA

We discuss the analyses of gated, x-ray imaging data from polar-direct-drive experiments with cryogenically layered deuterium–tritium targets on the OMEGA laser. The in-flight shell asymmetries were diagnosed at various times during the implosion, which was caused by the beam pointing geometry and preimposed variations in the energy partition between the different groups of laser beams. The shape of the ablation surface during the acceleration phase of the implosion was measured along two different lines of sight, and a Legendre mode (ℓ-mode) decomposition was applied for modes of up to ten to investigate shell asymmetries. A clear causal relationship between the imposed beam imbalance and the shape of the in-flight shell asymmetries was observed. The imploded shell with a balanced energy ratio shows smaller values of the amplitudes of ℓ-mode 2 compared to that from implosions with an imbalanced ring energy ratio. The amplitudes of ℓ-modes 4 and 6 are the same within the measurement uncertainty with respect to the change in beam energy ratio.

47 OTHER INSTRUMENTATION↗

Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements

The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 10 21 cm −3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 10 22 cm −3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 10 22 cm −3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. In conclusion, the resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.

Absorption spectroscopy↗