Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High altitude current-voltage measurement of GaAs/Ge solar cells

Measurements of high-voltage (Voc of 1.2 V) gallium arsenide on germanium tandem junction solar cells at air mass 0.22 showed that the insolation in the red portion of the solar spectrum is insufficient to obtain high fill factor. On the basis of measurements in the LeRC X-25L solar simulator, these cells were believed to be as efficient as 21.68 percent AM0. Solar simulator spectrum errors in the red end allowed the fill factor to be as high as 78.7 percent. When a similar cell's current-voltage characteristic was measured at high altitude in the NASA Lear Jet Facility, a loss of 15 percentage points in fill factor was observed. This decrease was caused by insufficient current in the germanium bottom cell of the tandem stack.

Hart, Russell E., Jr.↗

Bio-optical Measurement in the California Current

We measured the optical and bio-geochemical properties during the autumn 2004 CalCOFI cruise. Calibration of in situ radiometry instruments We maintain NIST-traceable calibration of our PRR-800/8 10 radiometers. SIRREX-linked calibrations for our PRR-800/8 10 have been accomplished by Biospherical Instruments, Inc. (BSI) and SDSU Center for Hydro Optics and Remote Sensing (CHORS) since May 1993.

Mitchell, B. Greg↗

A Critical Look at Coulomb Counting Approach for State of Charge Estimation in Batteries

In this paper, we consider the problem of state-of-charge estimation for rechargeable batteries. Coulomb counting is a well-known method for estimating the state of charge, and it is regarded as accurate as long as the battery capacity and the beginning state of charge are known. The Coulomb counting approach, on the other hand, is prone to inaccuracies from a variety of sources, and the magnitude of these errors has not been explored in the literature. We formally construct and quantify the state-of-charge estimate error during Coulomb counting due to four types of error sources: (1) current measurement error; (2) current integration approximation error; (3) battery capacity uncertainty; and (4) timing oscillator error/drift. It is demonstrated that the state-of-charge error produced can be either time-cumulative or state-of-charge-proportional. Time-cumulative errors accumulate over time and have the potential to render the state-of-charge estimation utterly invalid in the long term. The proportional errors of the state of charge rise with the accumulated state of charge and reach their worst value within one charge/discharge cycle. The study presents methods for reducing time-cumulative and state-of-charge-proportional mistakes through simulation analysis.

Battery management system↗

Capabilities and limitations of existing MST radars: Colorado wind profilers

The Wave Propagation Laboratory is developing a ground-based remote sensing system called PROFILER to measure troposphere parameters currently measured in operational meteorology by radiosondes. The prototype PROFILER uses two radars for wind sounding: a 6-m radar located at Platteville, Colorado, and a 33-cm radar located at Denver's Stapleton International Airport. In addition, a network of three 6-m wind-profiling radars is being installed in Colorado, and a fourth site is planned. The location of the five radars, their characteristics, and their limitations are described.

Strauch, R. G.↗

Fighter agility metrics

Fighter flying qualities and combat capabilities are currently measured and compared in terms relating to vehicle energy, angular rates and sustained acceleration. Criteria based on these measurable quantities have evolved over the past several decades and are routinely used to design aircraft structures, aerodynamics, propulsion and control systems. While these criteria, or metrics, have the advantage of being well understood, easily verified and repeatable during test, they tend to measure the steady state capability of the aircraft and not its ability to transition quickly from one state to another. Proposed new metrics to assess fighter aircraft agility are collected and analyzed. A framework for classification of these new agility metrics is developed and applied. A complete set of transient agility metrics is evaluated with a high fidelity, nonlinear F-18 simulation. Test techniques and data reduction methods are proposed. A method of providing cuing information to the pilot during flight test is discussed. The sensitivity of longitudinal and lateral agility metrics to deviations from the pilot cues is studied in detail. The metrics are shown to be largely insensitive to reasonable deviations from the nominal test pilot commands. Instrumentation required to quantify agility via flight test is also considered. With one exception, each of the proposed new metrics may be measured with instrumentation currently available.

Liefer, Randall K.↗

Diagnostic system design for the Ion Auxiliary Propulsion System /IAPS/ - Flight test of two 8 cm mercury ion thrusters

The experimental design of a Diagnostic Subsystem (DSS) as part of an Ion Auxiliary Propulsion System (IAPS) to be flown on P80-1 spacecraft in May 1983, is discussed. The DSS is composed of several detectors measuring thruster efflux, material deposition and spacecraft potential relative to the local space plasma in the vicinity of two 8 cm mercury ion thrusters. The detectors consist of two QCM units measuring frequency in the range of two to 65 KHz. Nine solar cell arrays have the capability of measuring current and voltage from 0-600 mA and 0-0.9 V. Seven ion collectors can measure ion currents with bias voltages of 0, 25, 55 and 96 V. The potential probe can measure current at 16 different commandible levels varying from one to 5 K microamperes within a voltage range of -25 to 175 V. The analysis of the ground-based data indicates that the hardware is qualified for flight, with the detectors and electronic units having passed all functional and environmental tests. Block diagrams are given and the functional parameters of the different design configurations are described.

Hurst, E. B.↗

High-temperature strain measurement techniques: Current developments and challenges

Since 1987, a very substantial amount of R&D has been conducted in an attempt to develop reliable strain sensors for the measurements of structural strains during ground testing and hypersonic flight, at temperatures up to at least 2000 deg F. Much of the effort has been focused on requirements of the NASP Program. This presentation is limited to the current sensor development work and characterization studies carried out within that program. It is basically an assessment as to where we are now and what remains to be done in the way of technical accomplishments to meet the technical challenges posed by the requirements and constraints established for the NASP Program. The approach for meeting those requirements and constraints has been multi-disciplinary in nature. It was recognized early on that no one sensor could meet all these requirements and constraints, largely because of the large temperature range (cryogenic to at least 2000 deg F) and many other factors, including the most challenging requirement that the sensor system be capable of obtaining valid 'first cycle data'. Present candidate alloys for resistance-type strain gages include Fe-Cr-Al and Pd-Cr. Although they have superior properties regarding withstanding very high temperatures, they exhibit large apparent strains that must either be accounted for or cancelled out by various techniques, including the use of a dual-element, half-bridge dummy gage, or electrical compensation networks. A significant effort is being devoted to developing, refining, and evaluating the effectiveness of those techniques over a broad range in temperature and time. In the quest to obtain first-cycle data, ways must be found to eliminate the need to prestabilize or precondition the strain gage, before it is attached to the test article. It should be noted that present NASP constraints do not permit prestabilization of the sensor, in situ. Gages are currently being 'heat treated' during manufacture in both the wire- and foil-type resistance strain gages, and evaluation is in progress. In addition, the 'gage-on-shim' concept is being revisited. That concept will permit heat treatment of the gage during manufacture, before attachment on the test article. Also, it may permit the individual calibration of each gage regarding gage factor and apparent strain. Candidate alloys for the NASP include titanium metal-matrix and carbon-carbon composites. Although those materials have very attractive properties at elevated temperatures in terms of strength and weight, they pose significant attachment problems. Methods for making reliable strain gage and thermocouple attachments to them are currently under development. Experience to date indicates that Rokide attachment of the sensor directly to the protective coating is easier than to the base material itself. However, interpreting strain data from gages attached in this way may prove difficult because of possible cracks in the coating that form 'islands' and the mobility of those 'islands'. It is concluded, therefore, that major technical challenges lie ahead as we proceed to meet the stringent strain sensor requirements and constraints of the NASP Program.

Lemcoe, M. M.↗

Cluster electric current density measurements within a magnetic flux rope in the plasma sheet

On August 22, 2001 all 4 Cluster spacecraft nearly simultaneously penetrated a magnetic flux rope in the tail. The flux rope encounter took place in the central plasma sheet, Beta(sub i) approx. 1-2, near the leading edge of a bursty bulk flow. The "time-of-flight" of the flux rope across the 4 spacecraft yielded V(sub x) approx. 700 km/s and a diameter of approx.1 R(sub e). The speed at which the flux rope moved over the spacecraft is in close agreement with the Cluster plasma measurements. The magnetic field profiles measured at each spacecraft were first modeled separately using the Lepping-Burlaga force-free flux rope model. The results indicated that the center of the flux rope passed northward (above) s/c 3, but southward (below) of s/c 1, 2 and 4. The peak electric currents along the central axis of the flux rope predicted by these single-s/c models were approx.15-19 nA/sq m. The 4-spacecraft Cluster magnetic field measurements provide a second means to determine the electric current density without any assumption regarding flux rope structure. The current profile determined using the curlometer technique was qualitatively similar to those determined by modeling the individual spacecraft magnetic field observations and yielded a peak current density of 17 nA/m2 near the central axis of the rope. However, the curlometer results also showed that the flux rope was not force-free with the component of the current density perpendicular to the magnetic field exceeding the parallel component over the forward half of the rope, perhaps due to the pressure gradients generated by the collision of the BBF with the inner magnetosphere. Hence, while the single-spacecraft models are very successful in fitting flux rope magnetic field and current variations, they do not provide a stringent test of the force-free condition.

Slavin, J. A.↗

Microwave measurements of ocean currents for the SAXON experiment

Measurements of ocean surface currents carried out during the SAXON experiment using the University of Massachusetts stepped-frequency Delta-K radar (SFDKR) are presented. The measurement site was the Chesapeake light tower situated in the north Atlantic Ocean, 15 km off the coast of Virginia Beach, Virginia. The radar was placed on a platform 26 m above mean sea level. Measurements were made at grazing angles between 3 and 10 deg. A nearly uninterrupted record of ocean current velocity was obtained for a 26-day period. The measurement dependence on various system and hydrodynamic parameters and a comparison with an independent in-situ current measurement (EM current meter) are presented. Experimental results show that the Delta K spectrum with a distinguishable resonant line can be measured under all weather conditions, from calm seas with large swells to the fully developed seas occurring under winds as high as 20 ms-1. The only parameter that needs to be adjusted in real time is the frequency separation, Delta f, which has to be modified according to the varying shape of the ocean wave spectrum. Currents could not be accurately measured for very low wind conditions, even though resonant lines were present in the Delta K spectrum. The SFDKR can accurately measure wind-driven surface currents for wide range of wind conditions.

Popstefanija, Ivan↗

First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.

Javadi, H.↗

Apparatus for measuring high frequency currents

An apparatus for measuring high frequency currents includes a non-ferrous core current probe that is coupled to a wide-band transimpedance amplifier. The current probe has a secondary winding with a winding resistance that is substantially smaller than the reactance of the winding. The sensitivity of the current probe is substantially flat over a wide band of frequencies. The apparatus is particularly useful for measuring exposure of humans to radio frequency currents.

Hagmann, Mark J.↗

Capaciflector-guided mechanisms

A plurality of capaciflector proximity sensors, one or more of which may be overlaid on each other, and at least one shield are mounted on a device guided by a robot so as to see a designated surface, hole or raised portion of an object, for example, in three dimensions. Individual current-measuring voltage follower circuits interface the sensors and shield to a common AC signal source. As the device approaches the object, the sensors respond by a change in the currents therethrough. The currents are detected by the respective current-measuring voltage follower circuits with the outputs thereof being fed to a robot controller. The device is caused to move under robot control in a predetermined pattern over the object while directly referencing each other without any offsets, whereupon by a process of minimization of the sensed currents, the device is dithered or wiggled into position for a soft touchdown or contact without any prior contact with the object.

Vranish, John M.↗

Silicon solar cells as a high-solar-intensity radiometer

The characteristics of a conventional, 1- by 2-cm, N/P, gridded silicon solar cell when used as a radiometer have been determined for solar intensity levels to 2800 mW/sq cm (20 solar constants). The short-circuit current was proportional to the radiant intensity for levels only to 700 mW/sq cm (5 solar constants). For intensity levels greater than 700 mW/sq cm, it was necessary to operate the cell in a photoconductive mode in order to obtain a linear relation between the measured current and the radiant intensity. When the solar cell was biased with a reverse voltage of -1 V, the measured current and radiant intensity were linearly related over the complete intensity range from 100 to 2800 mW/sq cm.

Spisz, E. W.↗

Ocean current surface measurement using dynamic elevations obtained by the GEOS-3 radar altimeter

Remote Sensing of the ocean surface from the GEOS-3 satellite using radar altimeter data has confirmed that the altimeter can detect the dynamic ocean topographic elevations relative to an equipotential surface, thus resulting in a reliable direct measurement of the ocean surface. Maps of the ocean dynamic topography calculated over a one month period and with 20 cm contour interval are prepared for the last half of 1975. The Gulf Stream is observed by the rapid slope change shown by the crowding of contours. Cold eddies associated with the current are seen as roughly circular depressions.

Leitao, C. D.↗

Carbon Nanofibers Synthesized on Selective Substrates for Nonvolatile Memory and 3D Electronics

A plasma-enhanced chemical vapor deposition (PECVD) growth technique has been developed where the choice of starting substrate was found to influence the electrical characteristics of the resulting carbon nanofiber (CNF) tubes. It has been determined that, if the tubes are grown on refractory metallic nitride substrates, then the resulting tubes formed with dc PECVD are also electrically conducting. Individual CNFs were formed by first patterning Ni catalyst islands using ebeam evaporation and liftoff. The CNFs were then synthesized using dc PECVD with C2H2:NH3 = [1:4] at 5 Torr and 700 C, and approximately equal to 200-W plasma power. Tubes were grown directly on degenerately doped silicon <100> substrates with resistivity rho approximately equal to 1-5 meterohm-centimeter, as well as NbTiN. The approximately equal to 200-nanometer thick refractory NbTiN deposited using magnetron sputtering had rho approximately equal to 113 microohm-centimeter and was also chemically compatible with CNF synthesis. The sample was then mounted on a 45 beveled Al holder, and placed inside a SEM (scanning electron microscope). A nanomanipulator probe stage was placed inside the SEM equipped with an electrical feed-through, where tungsten probes were used to make two-terminal electrical measurements with an HP 4156C parameter analyzer. The positive terminal nanoprobe was mechanically manipulated to physically contact an individual CNF grown directly on NbTiN as shown by the SEM image in the inset of figure (a), while the negative terminal was grounded to the substrate. This revealed the tube was electrically conductive, although measureable currents could not be detected until approximately equal to 6 V, after which point current increased sharply until compliance (approximately equal to 50 nA) was reached at approximately equal to 9.5 V. A native oxide on the tungsten probe tips may contribute to a tunnel barrier, which could be the reason for the suppressed transport at low biases. Currents up to approximately 100 nA could be cycled, which are likely to propagate via the tube surface, or sidewalls, rather than the body, which is shown by the I-V in figure (a). Electrical conduction via the sidewalls is a necessity for dc NEMS (nanoelectromechanical system) applications, more so than for the field emission applications of such tubes. During the tests, high conductivity was expected, because both probes were shorted to the substrate, as shown by curve 1 in the I-V characteristic in figure (b). When a tube grown on NbTiN was probed, the response was similar to the approximately equal to 100 nA and is represented by curve 2 in figure (b), which could be cycled and propagated via the tube surface or the sidewalls. However, no measureable currents for the tube grown directly on Si were observed as shown by curve 3 in figure (b), even after testing over a range of samples. This could arise from a dielectric coating on the sidewalls for tubes on Si. As a result of the directional nature of ion bombardment during dc PECVD, Si from the substrate is likely re-sputtered and possibly coats the sidewalls.

Kaul, Anupama B.↗