Wide Dynamic Range Porous Plug for SIRTF

The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which the telescope is launched warm and subsequently cooled to operating temperature on orbit. At launch, the cryostat is at 2 K and the telescope is at room temperature. Cooldown of the telescope will be accomplished initially through radiation to space. Final cooldown to the 5.5 K operating temperature is done with helium vapor. Initially, the helium flow on orbit will be 20 to 30 times larger than required for steady-state operation. The vent line and the liquid/vapor phase separator (porous plug) therefore must accommodate a large dynamic operational range.For ground testing of IR instruments, the required temperature is 1.5 K. The helium tank temperature for both ground testing and space operations thus needs to be at 1.4 K. We present a discussion of the requirements, a conceptual design, and initial laboratory test results with candidate porous plugs and associated instrumentation. A discussion of possible connections to the design of the Gravity Probe-B cryostat will be presented also.

SIRTF, Liquid/Vapor Phase, Separator, Porous Plug↗

The EBIT Calorimeter Spectrometer: A New, Permanent User Facility at the LLNL EBIT

The EBIT Calorimeter Spectrometer (ECS) has recently been completed and is currently being installed at the EBIT facility at the Lawrence Livermore National Laboratory. The ECS will replace the smaller XRS/EBIT spectrometer that has been in almost continuous operation since 2000. The XRS/EBIT was based on a spare laboratory cryostat and an engineering model detector system from the Suzaku/XRS observatory. The new ECS spectrometer was built from the ground up to be a low maintenance, high performance microcalorimeter spectrometer with 4 eV resolution at 6 keV, 32 detector channels, 10 us event timing, and capable of uninterrupted acquisition sessions of over 70 hours at 50 mK. The XRSIEBIT program has been extremely successful, producing over two-dozen refereed publications on topics such as laboratory astrophysics, atomic physics, nuclear physics, and calibration of the spectrometers for the National Ignition Facility, with many more publications in preparation. The ECS spectrometer will continue this work into the future with improved spectral resolution, integration times, and ease-of-use. We designed the ECS instrument with TES detectors in mind by using the same highly successful magnetic shielding as our laboratory TES cryostats. This design will lead to a future TES instrument at the LLNL EBIT. This proposed future instrument would include a hybrid detector system with 0.8 eV resolution in the band from 0.1-1.0 keV, 2 eV from 0.1-10 keV, and 30 eV from 0.5-100 keV, with high quantum efficiency in each band. Here we discuss the legacy of the XRS/EBIT program, the performance of the new ECS spectrometer, and plans for a future TES spectrometer.

Porter, S.↗

The Road to Launch and Operations of the Spitzer Space Telescope

Spitzer Space Telescope, the fourth and final of NASA's Great Observatories, and the cornerstone to NASA's Origins Program, launched on 25 August 2003 into an Earth-trailing solar orbit to acquire infrared observations from space. Spitzer has an 85cm diameter beryllium telescope, which operates near absolute zero utilizing a liquid helium cryostat for cooling the telescope. The helium cryostat, though designed for a 2.5 year lifetime, through creative planning now has an expected lifetime of 5.5 years. Spitzer has completed its in-orbit checkout/science verification phases and the first two years of nominal operations, becoming the first mission to execute astronomical observations from a solar orbit. Spitzer was designed to probe and explore the universe in the infrared utilizing three state of the art detector arrays providing imaging, photometry, and spectroscopy over the 3-160 micron wavelength range...

infrared↗

Thermal Performance Testing of Cryogenic Insulation Systems

Efficient methods for characterizing thermal performance of materials under cryogenic and vacuum conditions have been developed. These methods provide thermal conductivity data on materials under actual-use conditions and are complementary to established methods. The actual-use environment of full temperature difference in combination with vacuum-pressure is essential for understanding insulation system performance. Test articles include solids, foams, powders, layered blankets, composite panels, and other materials. Test methodology and apparatus design for several insulation test cryostats are discussed. The measurement principle is liquid nitrogen boil-off calorimetry. Heat flux capability ranges from approximately 0.5 to 500 watts per square meter; corresponding apparent thermal conductivity values range from below 0.01 up to about 60 mW/m- K. Example data for different insulation materials are also presented. Upon further standardization work, these patented insulation test cryostats can be available to industry for a wide range of practical applications.

Fesmire, James E.↗

Cryogenic Testing of Different Seam Concepts for Multilayer Insulation Systems

Recent testing in a cylindrical, comparative cryostat at the Cryogenics Test Laboratory has focused on various seam concepts for multilayer insulation systems. Three main types of seams were investigated: straight overlap, fold-over, and roll wrapped. Each blanket was comprised of 40 layer pairs of reflector and spacer materials. The total thickness was approximately 12.5-mm, giving an average layer density of 32 layers per centimeter. The blankets were tested at high vacuum, soft vacuum, and no vacuum using liquid nitrogen to maintain the cold boundary temperature at 77 K. Test results show that all three seam concepts are all close in thermal performance; however the fold-over method provides the lowest heat flux. For the first series of tests, seams were located 120 degrees around the circumference of the cryostat from the previous seam. This technique appears to have lessened the degradation of the blanket due to the seams. In a follow-on test, a 20 layer blanket was tested in a roll wrapped configuration and then cut down the side of the cylinder, taped together, and re-tested. This test result shows the thermal performance impact of having the seams all in one location versus having the seams clocked around the vessel. This experimental investigation indicates that the method of joining the seams in multilayer insulation systems is not as critical as the quality of the installation process.

Johnson, Wesley L.↗

Testing Devices Garner Data on Insulation Performance

To develop a test instrument that could garner measurements of the thermal performance of insulation under extreme conditions, researchers at Kennedy Space Center devised the Cryostat 1 and then Cryostat 2. McLean, Virginia-based QinetiQ North America licensed the technology and plans to market it to organizations developing materials for things like piping and storage tank insulation, refrigeration, appliances, and consumer goods.

Source record↗

Modeling of Non-Isothermal Cryogenic Fluid Sloshing

A computational fluid dynamic model was used to simulate the thermal destratification in an upright self-pressurized cryostat approximately half-filled with liquid nitrogen and subjected to forced sinusoidal lateral shaking. A full three-dimensional computational grid was used to model the tank dynamics, fluid flow and thermodynamics using the ANSYS Fluent code. A non-inertial grid was used which required the addition of momentum and energy source terms to account for the inertial forces, energy transfer and wall reaction forces produced by the shaken tank. The kinetics-based Schrage mass transfer model provided the interfacial mass transfer due to evaporation and condensation at the sloshing interface. The dynamic behavior of the sloshing interface, its amplitude and transition to different wave modes, provided insight into the fluid process at the interface. The tank pressure evolution and temperature profiles compared relatively well with the shaken cryostat experimental test data provided by the Centre National D'Etudes Spatiales.

Cryogenics↗

The Focal Plane Assembly for the Athena X-Ray Integral Field Unit Instrument

This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off-line coincidence detection to identify and reject events caused by the in-orbit high-energy particle background. The detectors, operating at 55 mK, or less, will be thermally isolated from the instrument cryostat's 2 K stage, while shielding and filtering within the FPA will allow the instrument's sensitive sensor array to be operated in the expected environment during both on-ground testing and in-flight operation, including stray light from the cryostat environment, low-energy photons entering through the X-ray aperture, low-frequency magnetic fields, and high-frequency electric fields.

SQUID amplifier↗

Vibration-Heating in ADR Kevlar Suspension Systems

The cryogenics group at NASA's Goddard Space Flight Center has a long-standing development and test program for laboratory and space-flight adiabatic demagnetization refrigerators (ADRs). These devices are used to cool components to temperatures as low as 0.05 K. At such low temperatures the ADR systems can provide a few micro-Watts of cooling power, so it is important to minimize the conduction of heat to these cold stages from the surroundings. The cold ADR elements are held in place by thin tensioned strings made of Kevlar, chosen for its high strength and stiffness and low thermal conductivity. During laboratory testing, we have observed that occasional significant additional heat loads on the coldest ADR stages correlate with unusually high vibration levels in the cryostat due to a noisy mechanical cryocooler. We theorized that this heat results from plastic deformation of the Kevlar fibers and frictional interactions among them, driven by the cryostat vibrations. We describe tests and calculations performed in attempt to confirm this source of the heating, and we discuss possible strategies to reduce this effect in future ADR suspension systems.

Vibration-heating↗

Cryogenic Technologies for the Stratospheric Observatory for Infrared Astronomy (SOFIA) Science Instruments

This work was performed at the request of the Program Chief Engineer for Stratospheric Observatory for Infrared Astronomy (SOFIA). The intended audience for this position paper is the prospective SOFIA Science Instrument (SI) developer, who may not have extensive experience with cryogenics or cryostat design. The objective is to provide an introductory handbook that (1) concisely summarizes SOFIA requirements, (2) describes components and techniques that enable cryostats to reach temperatures ranging from 4 K to 50 mK, and (3) warns of common pitfalls that an SI developer might encounter.

Stratospheric Observatory for Infrared Astronomy↗

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

Development of an End-to-end Demonstration Readout Chain for Athena/X-IFU

The X-ray Integral Field Unit(X-IFU) of the Athena observatory, scheduled for launch in the mid2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved with a 2kilo-pixel array of transition-edge sensor (TES) microcalorimeters. The complete detection chain is under development by a large international collaboration. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench uses a two-stage ADR cryostat from Entropy GmbH, a 1024-pixelarray, and will initially be operated using a warm electronics chain from NIST and NASA Goddard Space Flight Center. We describe the complete system being installed in the cryostat and the current results obtained with these electronics. We also review the status of the integration of the digital readout electronics (DRE)prototype into the demonstration chain and the plan for integrating and testing the complete X-IFU readout chain.

S Beaumont↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

190-GHz radiation from a quasioptical Josephson junction array

At 190 GHz, 0.36 micro W has been detected from an 11 x 58 array of niobium Josephson junctions. The power is radiated directly into free space above the surface of the two-dimensional array of junctions. Detection is made by a commercial bolometer outside the array cryostat. The junctions in the array are closely spaced in the y-dimension, but spaced by more than one-half wavelength in the x-direction. This asymmetry results in mutual phase-locking between adjacent junctions suitable for the production of y-polarized radiation. The resonance and asymmetry also result in a reasonable impedance match between the Josephson junctions and the free-space radiation mode.

ARRAY CRYOSTAT↗

Dynamic Simulation of a Periodic 10 K Sorption Cryocooler

A transient thermal simulation model has been developed to simulate the dynamic performance of a multiple-stage 10 K sorption cryocooler for spacecraft sensor cooling applications that require periodic quick-cooldown (under 2 minutes) , negligible vibration, low power consumption, and long life (5 to 10 years). The model was specifically designed to represent the Brilliant Eyes Ten-Kelvin Sorption Cryocooler Experiment (BETSCE), but it can be adapted to represent other sorption cryocooler systems as well. The model simulates the heat transfer, mass transfer, and thermodynamic processes in the cryostat and the sorbent beds for the entire refrigeration cycle, and includes the transient effects of variable hydrogen supply pressures due to expansion and overflow of hydrogen during the cooldown operation. The paper describes model limitations and simplifying assumptions, with estimates of errors induced by them, and presents comparisons of performance predictions with ground experiments. An important benefit of the model is its ability to predict performance sensitivities to variations of key design and operational parameters. The insights thus obtained are expected to lead to higher efficiencies and lower weights for future designs.

cryocooler design performance sorption simulation ↗